HomeMy WebLinkAboutROOF PERMIT PLAN REVIEWArchitectonic Inc
April 4, 2018
St�iiq, p
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pieice, FL 34982
Re: Roofing specification prepared fo'r the St. Lucie County Building Dept. for the structure
located at 610 Beach Avenue, Port St. Lucie, Florida
Manufacturer: Polyglass USA
Profiles: Modified Bitumen Roof System, FL #1654-1122
Code: FBC 2017; Section 1507
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: %" /12 Minimum
Required Design Pressure: Zone1: -26.0 Zone 2: -41.0 Zone3: -57.0
Maximum Uplift Pressure: -90 psf
Base: SBS-SA (self- adhering)
Ply Sheet: (Optional) One or more Elastoflex SA V Base (self -adhering)
Cap: SBS-SA, SBS-TA, APP-SA, APP-TA (self -adhering)
Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thr l out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2,
and 4" O.C. tl4ru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
OF FAQ
nt=p fu+ll'9-�LrlvcUf THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
73AR96 MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
' .Tal
ST. CIE COUNTY BUILDING DI ISION' - �
REVIEWED FOR COMPLIANC. �0�
REVIE E Y
DATE CONCEALED FASTENERS OR ATTACHMENTS
PLANS AND PERMIT MUST BE KB ON JOB ARE THE RESPONSIBIL►TYOFTHE
SITE OR NO INSPECTIONS) WILL BE MADI! (3dNTRACTOR OR RECORD
I
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com