HomeMy WebLinkAboutNOACOUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
Petersen Aluminum Corporation
102 Northpoint Parkway, B1dg.106
Acworth, GA. 30102
SCOPE:
This NOA is being issued under the applicable rules
documentation submitted has been reviewed and acc
used in Miami Dade County and other areas where a
This NOA shall not be valid after the expiration dat
(In Miami Dade County) and/or the AHJ (in areas c
or material tested for quality assurance purposes. If
manufacturer will incur the expense of such testing
of such product or material within their jurisdiction
determined by Miami -Dade County Product Contra
of the applicable building code.
This product is approved as described herein, and h
including the High Velocity Hurricane Zone of the
I
SCANNED
By
;SOURCES (RER)
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade&ov/economv
regulations governing the use of construction materials. The
d by Miami -Dade County RER - Product Control Section to be
ed by the Authority Having Jurisdiction (AHJ).
stated below. The Miami -Dade County Product Control Section
ter than Miami Dade County) reserve the right to have this product
us product or material fails to perform in the accepted manner, the
nd the AHJ may immediately revoke, modify, or suspend the use
RER reserves the right to revoke this acceptance, if it is
Section that this product or material fails to meet the requirements
been designed to comply with the Florida Building Code
>rida Building Code.
DESCRIPTION: Edge-Loc 1.0: x 16" wide x 24 ga. Steel Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product o process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety. I -
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA 14-0129.11 and consists of pages 1 through S.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category
Roofing
Sub -Category:
Metal, Pa
Materials:
Steel
Deck Tyne:
Wood
Maximum Design Pressure
—101 psf.
TRADE NAMES OF PRODUCTS MANUFAC
Product Dimensions .
Edge-Loc 1.0 Length: various
Width: 16"
Height: 1"
Thickness 0.024" (24 ga.)
Min. Yield Strength: 50 ksi
Trim Pieces Length: varies
Width: varies
Thickness 0.024" (24 ga.)
EVIDENCE SUBMITTED:
Test Agency
Valspar
Valspar
Force Engineering & Testing
Inc.
Farabaugh Engineering and
Testing Inc.
433X51
4331317
72-0314T-0
T15
on -Structural)
[ZED OR LABELED BY APPLICANT:
Test Product
Specifications Description
TAS 110 Corrosion resistant, prefmished, coated
galvanized, galvalume, standing seam, metal
panels.
N/A Corrosion resistant, prefmished, coated
galvanized, galvalume, standing seam, metal
panels.
Test Name/Report
Date
ASTM B 117
11/21/11
ASTM D 4587, ASTM G 23
11/21/11
TAS 125
03/24/07
TAS 100 04/14/07
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 2 of 5
APPROVED ASSEMBLIES:
System: Edge-Loc 1.0 Panel x 16" Wide x 24 ga. Steel
Deck Type:
Deck Description:
Slope Range:
Maximum Uplift
Pressure:
Wood, Non -Insulated
New Construction 19/3
greater plywood.
2": 12" or greater
See Table A below
or greater plywood or wood plank, or for re -roofing 15/32" or
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
15/32") The above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment, shall be an ASTM D 226 Type II installed with a minimum 4"
side -lap' and 6" end -laps Underlayment shall, be fastened with corrosion resistant tin -caps
and 12 gauge 1 ''/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered
rows 12" o.c. in the field of the roll. Or, any approved underlayment having,a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
i
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC Contractors Association's current published installation instructions.
Metal Panels and Install the "Edge-Loc 1.0 Panel" and accessories in compliance with the current published
Accessories: installation instructions and details in PAC Contractors Association's Installation Manual.
Flashings, penetrations, valley construction and other details shall be constructed in
compliance with Roofing Application Standard RAS 133.
i
Panels shall be secured!at a spacing listed below in Table A with corrosion resistant #10-13
x 1" pancake head screws of sufficient length to penetrate through the sheathing a minimum
3/16 of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
is snapped over the male rib of panel.
i
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Cornerl
Maximum Design Pressures
—59.75 psf.
—101 psf.
Maximum Screw Spacing
16" o.c.
6.75" o.c.
1. Extrapolation shall not be allowed
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 3 of 5
SYSTEM LIMITATIONS
1.
2.
3.
4.
5.
6.
Fire classification is not part of this
ratings of this product. -
The maximum designed pressure listed herein
and corners). Neither rational analysis, nor ext
pressure zones (i.e. perimeters, extended corn(
Panels may be rolls formed in continuous leng
Roofing Application Standard RAS 133.
All panels shall be permanently labeled with
statement: "Miami -Dade County Product Co
Seal as seen below. All clips shall be perm
model. I
refer to a current Approved Roofing Materials Directory for fire
all be applicable to all roof pressure zones (i.e. field, perimeters,
)olation shall be permitted for enhanced fastening at enhanced
and corners).
from eave to ridge. Maximum lengths shall be as described in
manufacturer's name and/or logo, city, state, and the following
I Approved" or with' the Miami -Dade County Product Control
atly labeled with the manufacturer's name and/or logo, and/or
MIAMI•DADE COUNTY
,...eMI
All products listed herein shall have a quality, assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
i
Panels may be shop or jobsite roll formed with machine models # 10110884, E00578860, or 01110072 from
PAC Contractors Association or manufactured at Petersen Aluminum Corporation's plant in Acworth, from
i
NOA No.: 17-1002.16
Expiration Date: 03/16/24
Approval Date: 11/02/17
Page 4 of 5
D
1
.J
j._
I
PROFILE DRAWINGS
16"
Z*"\--
1"
Fastener Relief, Stiffening Ribs and Striations are Optional
Field Condition
EDGE-Loc 1.0 PANEL SYSTEM
END OF THIS ACCEPTANCE