EVALUATION REPORT OF SCANNED
METAL SALES MANUFACTURING CORPORATION BY
'26 GA. 5V-CRIMP PANEL' St Luripcoun$v
l
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.4-R3
ROOFING
METAL ROOFING
RECEIVED
"I'll",
LST. Lucie County 1=61=M1Efi111 Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992 THESE PLANS AND ALL PROPOSED WORK
918 493-3568 ARE SUBJECT TO ANY CORRECTIONS
FAX:
( ) REQUIRED BY FIELD INSPECTORS THAT
COMPLY W TH ALLAPPLICABLE CODES.
This report consists of
Evaluation Report (3 Pages including cover) eo�9►e�it��e�e
Installation Details (1 Page) ��� SOCI(ALI di
Load Span Table (1 Page) °° s,P.•o E iV s .N6 "
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCE
DATE `T R�VIE/ DJY Report No. C2182-4
PLANS AND PERMIT MUST BE KE ON JOB Date: 9.9.17
SITE OR NO INSPEOTION(5) WILL ®E MADE
No 62240
:�•• STATE OF '•fie
��0,�• •A P, �e
0o P+L �%,
iv
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBIUTY OF THE
CONTRACTOR OR RECORD
FILE COSY
r
1 FL 14645.4-R3
C2182-4
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
r
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood or min. 3/4" thick
wood plank (min SG of 0.42) for new and existing constructions.
Designed by others and installed as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges. Designed as per FBC 2017.
Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
J
FL 14645.4-R3
C2182-4
9.9.17
Page 3 of 3
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This evaluation
report is not applicable in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section: 1505 and current approved roofing materials
directory or ASTM ;t108/UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents: UL580 & 1897 Test Reports
PRI Construction Materials Technologies
MSMC-017-02-01, Reporting Date 9/20/13
PANEL
5V-CRIMP
SEE DETAIL 2
-1, SEE DETAIL 1
FASTENER AT PANEL FLAT
REQUIRED FOR PANEL
ENDS ONLY.
MINIMUM ATTACHMENT:
UNDERLAYMENT SHALL BE INSTALLED Bd x 2.5" LONG RING SHANK NAIL
AS PER MANUFACTURER'S INSTALLATION OR #8 x 2" LONG WOOD SCREWS
GUIDELINES SPACED ® 6" O.C. IN THE FIELD
& AT EDGES
MIN. 2X- WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O.C.
TYPICAL PANEL INSTALLATION X-SECTION
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
UNDERLAYMENT J DETAIL 1
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
UNDERLAYMENT
DETAIL 2
5V-CRIMP
MIN 26 GA.
PANEL FASTENER PER UPLIFT
LOAD TABLE
a
0 0 �
O o
U N
0 WN
z o
4 mNO
U EnoO
-yt. M
U)
� owe
MJ�
j N
O
Ss�
N 00
Li
o
i
/
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
a
FLORIDA BUILDING CODE (FBC).
m
m
OSB 7/16" THICK (MIN.) OR
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.019'. EFFECTIVE COVERING
m
PLYWOOD 15/32" THICK (MIN.)
WIDTH OF PANEL = 24".
Z2
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
z
�xp
Z.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
zoo
ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING.
-
U)
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
z
z
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
8m
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
5V-CRIMP
MIN 26 GA
REQUIRED FOR EACH APPUCATION AND ARE THE RESPONSIBILITY OF OTHERS.
OSB 7/16" THICK (MIN.) OR
PLYWOOD 15/32" THICK (MIN.)
SHEET NO. '
' OF ,
METAL SALES MANUFACTURING CORPORATION
5V-Crimp Uplift Loads
(Min. 26 ,ga.)
Description
Fastener Spacing
along panel length
(in)
Allowable Uplift
Load
(psfl
Coverage width: 24"
Panel Fasteners
#9-16 or #10-14 hex head
wood screws with sealed
washer
6
172.5
9
120.0
_
12
90.0
15
72.0
18
60.0 _
21
51.4
24 {
45.0
40.0
27
30
36.0
33
32.7
30.0
36
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 14645.4 and Metal Sales current installation procedure.
3. Three or more spans condition.
1216 N Lansing Ave., Suite C
Tulsa, Ok 74106
918 492 5992
1%jiIII 1l1l,., e
!BOCK 44� oiasaa
oA P• • �C•EIVS°N� °a
0 No 62240 ;
O
:0 STATE OF •:�4ue
0 �Q. •�®��
awl 1
4 . g . 2G 1-�7
Bala Sockalingam, Ph.D., P.E.
FL 62240