Loading...
HomeMy WebLinkAboutEVALUATION REPORTI EVALUATION REPORT OF SCANNED METAL SALES MANUFACTURING CORPORATION BY '26 GA. 5V-CRIMP PANEL' St Luripcoun$v l FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.4-R3 ROOFING METAL ROOFING RECEIVED "I'll", LST. Lucie County 1=61=M1Efi111 Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4290 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 THESE PLANS AND ALL PROPOSED WORK 918 493-3568 ARE SUBJECT TO ANY CORRECTIONS FAX: ( ) REQUIRED BY FIELD INSPECTORS THAT COMPLY W TH ALLAPPLICABLE CODES. This report consists of Evaluation Report (3 Pages including cover) eo�9►e�it��e�e Installation Details (1 Page) ��� SOCI(ALI di Load Span Table (1 Page) °° s,P.•o E iV s .N6 " ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE DATE `T R�VIE/ DJY Report No. C2182-4 PLANS AND PERMIT MUST BE KE ON JOB Date: 9.9.17 SITE OR NO INSPEOTION(5) WILL ®E MADE No 62240 :�•• STATE OF '•fie ��0,�• •A P, �e 0o P+L �%, iv CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBIUTY OF THE CONTRACTOR OR RECORD FILE COSY r 1 FL 14645.4-R3 C2182-4 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp r Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood or min. 3/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges. Designed as per FBC 2017. Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c. (Factor of Safety = 2) 172.5 psf @ fastener spacing of 6" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8" and installed as per Metal Sales current installation procedure. At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 1897-04 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be J FL 14645.4-R3 C2182-4 9.9.17 Page 3 of 3 computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section: 1505 and current approved roofing materials directory or ASTM ;t108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & 1897 Test Reports PRI Construction Materials Technologies MSMC-017-02-01, Reporting Date 9/20/13 PANEL 5V-CRIMP SEE DETAIL 2 -1, SEE DETAIL 1 FASTENER AT PANEL FLAT REQUIRED FOR PANEL ENDS ONLY. MINIMUM ATTACHMENT: UNDERLAYMENT SHALL BE INSTALLED Bd x 2.5" LONG RING SHANK NAIL AS PER MANUFACTURER'S INSTALLATION OR #8 x 2" LONG WOOD SCREWS GUIDELINES SPACED ® 6" O.C. IN THE FIELD & AT EDGES MIN. 2X- WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. TYPICAL PANEL INSTALLATION X-SECTION #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. UNDERLAYMENT J DETAIL 1 #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. UNDERLAYMENT DETAIL 2 5V-CRIMP MIN 26 GA. PANEL FASTENER PER UPLIFT LOAD TABLE a 0 0 � O o U N 0 WN z o 4 mNO U EnoO -yt. M U) � owe MJ� j N O Ss� N 00 Li o i / GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE a FLORIDA BUILDING CODE (FBC). m m OSB 7/16" THICK (MIN.) OR 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.019'. EFFECTIVE COVERING m PLYWOOD 15/32" THICK (MIN.) WIDTH OF PANEL = 24". Z2 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. z �xp Z. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS zoo ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING. - U) 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM z z REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL 8m 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS 5V-CRIMP MIN 26 GA REQUIRED FOR EACH APPUCATION AND ARE THE RESPONSIBILITY OF OTHERS. OSB 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) SHEET NO. ' ' OF , METAL SALES MANUFACTURING CORPORATION 5V-Crimp Uplift Loads (Min. 26 ,ga.) Description Fastener Spacing along panel length (in) Allowable Uplift Load (psfl Coverage width: 24" Panel Fasteners #9-16 or #10-14 hex head wood screws with sealed washer 6 172.5 9 120.0 _ 12 90.0 15 72.0 18 60.0 _ 21 51.4 24 { 45.0 40.0 27 30 36.0 33 32.7 30.0 36 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 14645.4 and Metal Sales current installation procedure. 3. Three or more spans condition. 1216 N Lansing Ave., Suite C Tulsa, Ok 74106 918 492 5992 1%jiIII 1l1l,., e !BOCK 44� oiasaa oA P• • �C•EIVS°N� °a 0 No 62240 ; O :0 STATE OF •:�4ue 0 �Q. •�®�� awl 1 4 . g . 2G 1-�7 Bala Sockalingam, Ph.D., P.E. FL 62240