Loading...
HomeMy WebLinkAboutPRODUCT DESCRIPTIONHigh -Temperature Underlayment for Metal and Con6rete Tile Roofing RECEIVED POLYSTICK8 TU PLUIAPR 0 4 2018 SCANNEDPRODUCT DESCRIPTION 1�3 • Lucie Countyr Pem Polystick TU PLUS is a homogeneous rubberized a pna�t"wa erproofing underlayrnent fiberglass reinforced, with a high strength polyester fabric on the upper surface, designed specifically for use as a the underlayment. Polystick TU PLUS is ideally suited for use where roofing tiles are installed via adhesive set applications; Polystick TU PLUS can also be installed in mechanically attached systems as the rubberized asphalt seals around correctly installed nails on the weathering surface. Polystick TU PLUS is designed for use in new construction and re -roof application where tiles may be stacked on rooftops for extended periods of time. Polystick TU PLUS may be exposed for up to 180 days. Polystick TU PLUS underlayments ore manufactured using patented ADESO® Dualcompound Self -Adhesive technology, whereby a "true" polymer modified asphalt compound is applied on the top layer and an aggressive self-adhesive compound is (applied on the bottom layer. Polystick TU Plus features patented SEALLap®, a factory applied adhesive treatment at the membrane overlap. Each of these patented features provide for greater ease of application as well as improved product performance. USES • Multi -purpose steep slope underlayment, specially design,'ed for file applications • Designed as effective reinforcement for perimeter and flashing details • For use in both adhesive set and mechanically fastened roof tile application's FEATURES AND BENEFITS I • Proprietary asphalt compound and fiberglass mat for exceptional dimensional stability • Non wicking polyester reinforced surface engineered for superior slip resistance • Approved exposure rating to 180 days (or as limited by local building codes) TECHNICAL DESCRIPTION METHODTEST ASTM D5147 PROPERTY Thickness, min, mm (mils) TYPICAL VALUE 2.0(80) ASTM D5147 Maximum load, Longitudinal and Transverse, min, kN/m (Ibf/in.) 4.4(25) ASTM D5147 Elongation at break, min of modified bitumen portion (%) 10 ASTM D5147 Tear Resistance, Longitudinal and Transverse, min, N (lbf) 89 (20) ASTM E96 Moisture Vapor Permeability, max, perms 0.1 ASTM D1970 Adhesion to Plywood @400F,„min, Ibf/ftwidth 2.0 ASTM D1970 Adhesion to Plywood @ 757, min, Ibf/h width 12.0 ASTM D1970 Sealobility around nail pass ASTM D1970 Waterproof integrity after low temp flexibility pass ASTM D1970 Waterproof integrity of lap seam Ipass ASTM D1970 Slip Resistance pass Copyright ©2011 by Polygloss U.S.A., Inc and all rights are reserved Edition Date: 08/11 • Doc# TU PLUS SELF-AONES/VE TECMWOlOOY PRODUCT DATA Coverage (Nominal) ..................... 200 sq ft Weight (Approx)..............................70 Ibs Roll Size ............65'8" x 39 3/8" (20m x 1 m) Rolls/Pallet...........................................20 APPLICABLE STANDARDS • ASTM D 1970, D 5147 • Miami Dade Code Compliance • [CC ESR-1697 �t7 WATERPROOFING MATERIALS AND INSULATING SYSTEMS MAPE! 1-800-222-9782 www.polyglass.com POLYSTICKO TU PLUS APPLICATION INSTRUCTIONS • Apply Polystick TU PLUS directly to the roof deck. • Do not apply to shingles or other roof coverings. • Apply only when the weather is dry and material interface temperatures (air, roof deck, membrane) are 40' F and rising. • Always start at the lowest point of the roof deck where possible. • Cut the Polystick TU PLUS to a suitable, workable length (typically between 9 and 15 feet). • Lay the material flat in place, starting at the lowest point. Overlap seams 3" minimum and endlaps 6" minimum. • Peel half of the backing off the roll and apply firm, even pressure from the center to the outer edges. • Remove the backing from the remaining half of the roll and apply pressure. • Always ensure that Polystick TU PLUS is applied over the area to cover the highest point of "ice damming". • Be sure to follow all local building code recommendations and requirements with regards to the width of ice dam materials. • If full roof coverage application is desired, proper venting of the structure is required. • Consult a design professional for proper venting requirements. • In steep slope applications(i.e. 3:12 slope or higher) where backnailing will be required, be sure that all nails are covered by the overlapping next sheet. • Polystick TU PLUS must be covered within 180 days of installation unless otherwise limited by local authorities. • Use POLYPLUS 50 or PG 500 to seal all end laps, hip and ridge details, and any "fabric to fabric"splices, patches or details. • Apply a bed of cement on any metals, vents, stacks, chimneys, and other roof accessories. • Use on any repairs to the underlayment prior to application of the final roof covering. POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1 1 1 1 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.com General Line: (888) 410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions? technical@polyglass.com Product Disclaimer: Unless otherwise incorporated into or part of a supplemental manufacturer's warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a period of 1 year. Refer to material safety data sheet (MSDS) for specific data and handling of our products. All WATERPROOFING MATERIALS AND INSULATING SYSTEMS data furnished refers to standard production and is given in good faith within the applicable •Nvccj IF 1 manufacturing and testing tolerances. & MAPE! Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time with- . R . " P out prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products �j�fiJ/S aGI�• under conditions beyond its own control. /(`�� 1-800-222-9782 For most current product data and warranty information, visit www.polygloss.com www.polyglass.com