HomeMy WebLinkAboutREVISION 7-20-18\a'` eat a,-T," SCANN
OFFICE USE ONLY: p By�,,6 r__
DATE FILED: —1 1 ,q `NA L PERMIT # I %O4 (.0 Z
REVISION FEE: q 15 q,6 RECEIPT #
1.
2.
13.
4.
5.
G & DEVELOPMENT SERVICES
1G & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 462-1578
ON FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
5349 Oakland Lake Cir (lot 71)
19
DETAILED DESCRIPTION OF PROJECT C ` �x�. ( L
REVISIONS: +�: a¢? ''�«' j
1. Window in owner's bath removed ST. Lucie County, Permitting
2. Owner's bedroom wall moved 4" & roomisize changed
3.Owner's bath shower changed from recess to pan
4. Roof over the
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CRC
057817
BUSINESS NAME: NVR, IN
NAME,
QUALIFIERS NA? i10vDLUN11
ADDRESS: 56 CENTREPI
CITY: WEST PAZM BEACH
PHONE (DAYTIME): "
OWNER/BUILDER INFORMATION:
NVR, INC. dba RYAN H
ADDRESS:
CITY:
PHONE:
561-818-7950
ARCHITECT/ENGINEER INFORMATION: I
NAME: AB DESIGN GROUP INC.
ADDRESS:
CITY: LONGWOOD
PHONE (DAYTIME): 407-774-6078
Revised 07/22/2014
File Copy
Ak W6ff&UNTY CERT. #:
ATE: 1JL1ZIP:
FAX: 5 1-720-13 1
STATE:
FAX:
ZIP:
STATE: FL ZIP: 32750
FAX: 407-774-407R
Building Permit #
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name jQ'IY1C, Applicant:
H
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+32.37/-42.62
+50/-60 DP
Ply Gem
Series 4712 Flange
FL 14039.1
Non -Impact
If 10 Wood Screw with sufficient length to echleve1-1/4'embedment Requlredanchors: Head(3)• Jamb(3)
Mullions
N/A
+/-75 DP
Ply Gem
Series 4700 Flange
FL 15264.2
N/A
Use ''/.'Tapcon with sufficient length to achievea1Y.' minimum embedment with 2 Y' minimum edge distance.
Fixed Glass
+29.65/38.87
+/-55 DP
Ply Gem
Series 4701 Flange
FL 14434.1
Non -Impact
# 10 Wood Screw with sufficient length to achieve 1-1/4'embedment. Required anchors: Head(3), Jamb(3)
Block Glass
N/A
N/A
N/A
N/A
N/A
N/A
mass g,
,_
Skylights
N/A
N/A
N/A
N/A
N/A
N/A
sy
Sliding Glass Doors
+28.74/-42.62
+/-50 DP
Ply Gem
Series 4780
FL 14634.2
Non -Impact
3H6' Tapoon with sufficient length to achieve l-i �¢m e epki Be� Q4p1�ijq t .Jamb (5)Each window.
Swing Type Doorsit
+30.64/-30.64
+67.0/-67.0
ThermaTru
3'Ok6'0'SmoohStar Fheglass
FL5891.5
N/A
TwTapcon • Min Embedmaal,.1,4•M^�laam^ h� � 4 bRELCOTapmnlW.Min
French Doors
N/A
N/A
N/A
N/A
N/A
N/A
Garage Doors
+25.91/-31.39
+3.6/-42--Clepay--6x7-Model73W6-
6546.4
N/A
Jamb to block on veNral jamb l/4-X11/4-min t�,�i(ea�R steal washer required.
Hurricane Protection
N/A
+40/-40
Eastern Metal Supply
24ga Steel Panels
FL 11964.2
N/A
1/4a Tapcon Anchors, SG Tapcons _ - � { Y 7 lid -set Anchors.
Roof Ventilation
N/A`.::
r.g__'
Roofing Material
N/A
N/A
Tamko
N/A
FL18355.1
N/A
mils ...do- (i@nTss—rnB8mimumheedof3(6'.
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their use in this st cture. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
Name: JAMES JOSEPH CANTWELL Signature: _ seal
Design Prof: ARCHITECT Cert. No. AR0012079 Date: 06/26/18
FORM R405-2017
FLORIDA ENERGY EFFICIENC I CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 071 F1833 B LHG Den - W
Builder Name: Ryan Homes
Street: 5349 OAKLAND LAKE CIR
Permit Office: St. Lucie
• City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1707.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior R=4.1 1365.00 ft2
b. Frame - Wood, Adjacent
R=11.0 342.33 ftz
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1833.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1833.00 ft2
6. Conditioned floor area above grade (ft2) 1833
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
11. Ducts
R= ft2
R ft2
7. Windows(168.4 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 366.6
a. U-Factor: Dbl, U=0.54 115.11 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.63 53.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.32
a. Central Unit
28.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
27.8 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.313
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1833.0 sqft.) Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation R=0.0 1833.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.092 Total Proposed Modified Loads: 57.75
PASS
Total Baseline
Loads: 58.29
I hereby certify that the plans and specifications covered by
Review of the plans and
OIreHE STA?tc
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliancell
;� _ - ; • Off,
/
with the Florida Energy Code.
°
PREPARED BY:
c8-1a-zo19
DATE:
Before construction is completed
this buildin will be ins ected for
9 p
compliance with Section 553.908
9 r
t� ; t�l
* °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT:NL 1.4
BUILDING OpRIC(.
DATE: ��\O -`gj
W;
DATE: ! r i. is lv,:
.. ina
- Compliance requires certification by the air handler unit man facturer that t Z'z"!i r i13 '` I o'il'. fie ,
certified factory -sealed in accordance with R403.3.2.1. I-1 i ti L' '� (d
- Compliance requires an Air Barrier and Insulation Inspection Checklist in ac `�.
or a e wi . AL ' th', o t requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH 0 ( . : T4�1. `
- Compliance with a proposed duct leakage On requires a Duct Leakage Tes"Repo _*-An rmi iY It a to ou oors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 On for whole house.
File COP
8/10/2018 10:41 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
Ft7RM R405-2n17
I PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
• Comment:
Lot 071 F1833 B LHG Den - Bedrooms 3
User Condition d Area: 1833
Total Stori s: 1
1 Worst Call : No
Ryan Homes Rotate Anle: 180
St. Lucie Cross Vent lation: No
661000 Whole Hou a Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 71
Block/Subdivision: Oakland Lake
PlatBook:
Street: 5349 OAKLAND LAKE
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL,
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299 62 Low
�LOCKS
Number
Name
Area Volume
1
Blocki
1833 15947.1
SPACES
I
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1833 15947.1 Y Is 4
3
1 Yes Yes Yes
F�OORS
#
Floor Type
Space Perimete R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 157.5 ft 0
1833 ft2
- - - - 0.29 0 0.71
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1985 ft2 3I82 ft2 Dark
0.5
N 0:5 No 0 22.6
ANTIC
I
'/
V #
Type
Ventilation Ventratio(1 in)
Area
RBS IRCC
1
Full attic
Vented I300 1833 ft2
N N
CEILING
i
#
Ceiling Type
. Space R-Value. Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30l Blown
1833 ft2 0.1 Wood
8/10/2018 1.0:41 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FrIRAA Ran--F-9nl7
WALLS
Adjacent Space
Ornt Tn Wall Type
I Cavity Width Height Sheathing Framing Solar
Below
1
2
3
' 4
5
N=>S Exterior Concrete Block - Int Insul Main
E=>W Exterior Concrete Block - Int Insul Main
S=>N Exterior Concrete Block - Int Insul Main
W=>E Exterior Concrete Block - Int Insul Main
-=>SE Garage Frame - Wood Main
4.1 48 0 8
4.1 30 6 8
4.1 28 6 8
4.1 50 6 8
11 39 6 8
8 416.0 ft2 0
8 264.3 ftz 0
8 247.0 ftz 0
8 437.7 ftz 0
8 342.3 ftz 0
0 0.5
0 0.5
0 0.5
0 0.5
0.25 0.5
0
0
0
0
0
'
I DOORS
# Ornt Door Type Space
Storms
WidthArea
U-Value Ft In
In
Ft
1 E=>W Insulated Main
2 -=>SE Wood Main
None
None
.4 3
.46 2 8
6 8
6 8
20 ftz
17.8 ftz
WINDOWS
Orientation shown is the entered orientdtion => changed to As Built rotated 180 degrees).
Wall
# Ornt ID Frame Panes NFRC
I
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
1 e=>W 2 Metal Low-E Double Yes
2 s=>N 3 Metal 'Low-E Double Yes
3 w=>E 4 Metal Low-E Double Yes
4 W=>E 4 Metal Low-E Double Yes
0.�4 0.31 N
0. 4 0.31 N
0.5� 0.31 N
0.63 0.32 N
49.3 ftz 1 ft 0 in 2 It 0 in
16.4 ftz 1 ft 0 in 2 It 0 in
49.3 ftz 1 ft 0 in 2 It 0 in
53.3 ftz 1 ft 0 in 2 ft 0 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
None
�ARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 411 ftz 411 ftz
I 64 It
8.7 It
1
INFILTRATION
i
#
Scope Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000387
1860.5 I 102.14 192.09 .2825
7
HEATING SYSTEM
I.
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
I HSPF:8.2
27.8 kBtu/hr
1
sys#1
COOLING SYSTEM
I
# System Type Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/ Split
I SEER: 14
28 kBtu/hr 840 cfm
0.75 1
sys#1
8/10/2018 10:41 AM EnergyGauge® USA - FlaRes2017 S Iction R405.4.1 Compliant Software Page 3 of 4
I
I
FORM R405-2017
HO WATER SYSTEM
# System Type
SubType
LocationLLF Cap Use
SetPnt
Conservation
1 Electric
None
Garage50 gal 60 gal
120 deg
None
SOLAR F OT WATER SYSTEM
FSEC .
Collector
Storage
. .
Cert #
Company Name
Syst m Model # Collector Model
# Area
Volume
FEF
None
None
ftz
DUCTS
---- Supply ----
-- Return ----�
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location' , Are i Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 366.6 ft
Main 91.65Ift Proposed Qn
Main
--- cfm
73.3 cfm 0.04
0.50
1 1
TEI PERATURES
Programable Thermostat: Y
Ceiling Fans:
Coo lin r lJan
Heatin[�l Jan
[ ]Feb
[X] Feb
Mar
Mar
A r j j May Jun Jul
Apr [ ] May f Jun Jul
X� AugSe
] Aul
Sep
j j
[ ]
Oct
Oct
Nov
Nov
Dec
Dec
Venting[ ]Jan
I ]Feb
Mar
Apr [ ] May [ Jun ( Jul
l
[ ] Aug
l
[ Se
[X]
Oct
Nov
lX}
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78 78 78 78
78
78
80
80
80
80
PM
80
80
78 78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78 78 78 78
78
78
78
78
78
78
PM
78
78
78 78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66 66 66 68
68
68
68
68
68
68
PM
68
68
68 68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66-
66 66 66 68
68
68
68
68
68
68
PM
68
68
68 68 68 68
68
68
68
68
66
66
8/10/2018 10:41 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
I ADDRESS: 5349 OAKLAND LAKE CIR I Permit Number: I
FT. PIERCE, FL,
MANDATORY REQUIREMENTS See individual Bode sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display cad to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains i formation indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that thb EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for', the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal entlope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies anti multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelope. The building thermal emlelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes 1per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal • envelope.
Exception: Testing is not required for additions, alterations,
buildings in which the new construction is less than 85 percent of
During testing:
1. Exterior windows and doors, fireplace and stove doo
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, bac
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall
4. Exterior doors for continuous ventilation systems an(
5. Heating and cooling systems, if installed at the time
6. Supply and return registers, if installed at the time of
)vations, or repairs, of the building thermal envelope of existing
building thermal envelope.
shall be closed, but not sealed, beyond the intended
and flue dampers shall be closed, but not sealed beyond
be open.
heat recovery ventilators shall be closed and sealed.
if the test, shall be turned off.
the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled inI accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm pgr square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
8/10/2018 10:42 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5
MANDATORY REQUIREMENTS - (Co►itinued)
R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and corr�bustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet of less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R 8.
Exceptions:
1. Direct vent appliances with both intake and ex�aust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section �402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the! building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTMIE283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 controls. SECTIO N� R403 SYSTEMS
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each. separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). H lat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plen6 chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance withl ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have' a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measures with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed. at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be m
entire system, including the manufacturer's air
test.
Exceptions:
1. A duct air leakage test shall not be require
thermal envelope.
2. Duct testing is not mandatory for buildings
A written report of the results of the test shall be
R403.3.5 Building cavities (Mandatory). Building framing cavities
R403.4 Mechanical system piping insulation (Mandatory).
or below 55°F (13°C) shall be insulated to a minimum of R-3.
with a pressure differential of 0.1 inch w.g. (25 Pa) across the
enclosure. Registers shall be taped or otherwise sealed during the
the ducts and air handlers are located entirely within the building
by Section 405 of this code.
by the party conducting the test and provided to the code official.
not be used as ducts or plenums.
system piping capable of carrying fluids above 105°F (41 °C)
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water. i
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
8/10/2018 10:42 AM EnergyGauge® USA - RaRes20117 - FBC 6th Edition (2017) Complian Page 2 of 5
MANDATORY REQUIREMENTS - (Cc
R403.5.5 Heat traps (Mandatory). Storage water heaters r
heat traps installed on both the inlets and outlets. External he,
downward and upward bend of at least 3 1/2 inches (89 mm) in
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
tinued)
equipped with integral heat traps and having vertical pipe risers shall have
traps shall consist of either a commercially available heat trap or a
ie hot water distribution line and cold water line located as close as possible
R403.5.6.1.1 Automatic controls. Service water-h 'ating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 600C).
R403.5.6.1.2 Shut down. A separate switch or a Ilea' ly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of la combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a �ystem shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot *ter System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following riteria:
1. Be installed with a tilt angle between 10 de
2. Be installed at an orientation within 45 dep
R403.6 Mechanical ventilation (Mandatory). The building ?
Florida Building Code, Residential, or Florida Building Code, M
including: Natural, Infiltration or Mechanical means. Outdoor ai
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fai
ventilation system, fans shall meet the efficacy requirements
Exception: Where whole -house mechanical ventila
powered by an electronically commutated motor.
R403.6.2 Ventilation air.
ventilation system, fans shall meet the efficacy requirem
1. The design air change per hour minimums for resit
Indoor Air Quality, shall be the maximum rates allc
s and 40 degrees of the horizontal; and
of true south.
all be provided with ventilation that meets the requirements of the
chanical, as applicable, or with other approved means of ventilation
intakes and exhausts shall have automatic or gravity dampers that
efficacy. When installed to function as a whole -house mechanical
)f Table R403.6.1.
on fans are integral to tested and listed HVAC equipment, they shall be
When installed to function as a whole -house mechanical
of Table R403.6.1.
al buildings in ASHRAE 62.2, Ventilation for Acceptable
for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoorlspaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equ
equipment loads calculated in accordance with ACCA M
based on building loads for the directional orientation of
indoor units (if split system) shall be submitted along witl
described in Section R302.1. This Code does not allow c
affect equipment sizing. System sizing calculations shall
as standard kitchen and bathroom exhaust systems. Ne)
rating equal to or greater than the minimum required by I
TABLE R40
WHOLE -HOUSE MECHANICAL
)ment shall be sized in accordance with ACCA Manual S based on the
nual J or other approved heating and cooling calculation methodologies,
ie building. The manufacturer and model number of the outdoor and
the sensible and total cooling capacities at the design conditions
signer safety factors, provisions for future expansion or other factors that
iot include loads created by local intermittent mechanical ventilation such
or replacement heating and cooling equipment shall have an efficiency
deral law for the geographic location where the equipment is installed.
SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any �l
2.8 cfm/watt
Any
In -line fan
Any i
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 Umin. a. When test) d in accordance with HVI Standard 916
8110/2018 10:42 AM EnergyGauge® USA - FlaRes2 ,17 - FBC 6th Edition (2017) Complia
Page 3 of 5
MANDATORY REQUIREMENTS - (Cod tinued)
R403.7.1.1 Cooling equipment capacity. Co
than the calculated total load but not more than 1.15 times grey
Section 403.7, or the closest available size provided by the ma
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating-tes
expanded performance data shall be used to select cooling -only ec
temperature for the load calculation (or entering water temperature
performance data, the design value for entering wet -bulb temperate
Design values for entering wet -bulb and dry-bulb temperatures sh
calculation and shall be adjusted for return side gains if the return
ng only equipment shall be selected so that its total capacity is not less
�r than the total load calculated according to the procedure selected in
facturer's product lines. The corresponding latent capacity of the
value and shall not be used for equipment sizing. Manufacturer's
ipment. This selection shall be based on the outdoor design dry-bulb
or water -source equipment), the blower CFM provided by the expanded
e and the design value for entering dry-bulb temperature.
for the indoor dry bulb and relative humidity used for the load
s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residentia equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with gol�Od design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shail not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric
requirements calculated according to the procedure self
R403.7.1.2.3 Fossil fuel heating equipment. The
shall not be less than the design load calculated in acc
Lance furnaces shall be sized within 4 kW of the design
in Section R403.7.1.
of fossil fuel heating equipment with natural draft atmospheric burners
with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. I Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). I Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory) Snow- end ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50cF (1 VC), and no
precipitation is falling and an automatic or manual control that wil' allow shutoff when the outdoor temperature is above 40 OF (4.80C).
R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.101,5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methlods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the ene�gy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April116, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
8/10/2018 10:42 AM EnergyGauge® USA - FlaRes201h - FBC 6th Edition (2017) Complia Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump popl heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Lour Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatory)he energy consumption of
requirements of APSP-14.
S
ELECTRICAL POWER AND LIGHTING SYSTI
R404.1 Lighting equipment (Mandatory). Not less than 75 pe
high -efficacy lamps or not less than 75 percent of the permanently it
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas
8/10/2018 10:42 AM
portable spas shall be controlled by the
ON R404
MS
;ent of the lamps in permanently installed lighting fixtures shall be
:ailed lighting fixtures shall contain only high -efficacy lamps.
ng systems shall not have continuously burning pilot lights.
I
EnergyGauge® USA - FlaRes2 117
- FBC 6th Edition (2017) Complia Page 5 of 5
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISP��LAY CARD
ESTIMATED ENERGPERFORMANCE INDEX* = 99
• The lower the EnergyPerfor, , ance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (W)
7. Windows" Description
a. U-Factor: Dbl, U=0.54
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.63
SHGC: SHGC=0.32
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
5349 OAKLAND
New (From Plans)
Single-family
1
3
No
1833
Area
115.11 ft2
53.33 ft2
ft2
ft2
1.000 ft.
0.313
Insulation Area
R=0.0 1833.00 ft2
R= ft2
R= ft2
I certify that this home has complied with the Florida Energy
Construction through the above energy saving features whicl
in this home before final inspection. Otherwise, a new EPL E
based on installed Code compliant features.
Builder Signature: [� \ r
Address of New Home:
E CIR, FT. PIERCE, FL,
9. Wall Types
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Main, AH: Main
12. Cooling systems
a. Central Unit
13. Heating systems.
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
fficiency Code for Building
will be installed (or exceeded)
splay Card will be completed
Date: S-10 4
,f. City/FL Zip: �7(_
Insulation
R=4.1
R=11.0
R=
R=
Insulation
R=30.0
R=
R=
Area
1365.00 ft2
342.33 ft2
ft2
ft2
Area
1833.00 ft2
ft2
ft2
R ft2
6 366.6
kBtu/hr Efficiency
28.0 SEER:14.00
kBtu/hr Efficiency
27.8 HSPF:8.20
Cap: 50 gallons
EF: 0.9
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy' Gauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Buildi g Code, Energy Conservation, if not DEFAULT.
8/10/2018 10:41 AM EnergyGauge® USA - FlaRes201F - Section R405.4.1 Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TI�BLE 402.4.1.1
AIR BARRIER AND INSULATII'ON INSPECTION COMPONENT CRITERIA
Project Name: Lot 071 F1833 B LHG Den - W Builder Name: Ryan Homes
Street: 5349 OAKLAND LAKE CIR Permit Office: St. Lucie
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction: 661000
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
Ceiling/attic
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrie� shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs andlframing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier. I
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities.shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
i
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
I
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjace 9t to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and Itubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building theimal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire spri klers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates sna Zolis or ceil nas.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/10/2018 10:42 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-�- wrightsofto Project Summary
Entire House
One Stop Cooling and Heating
7225 Sandsoove Coot, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 6291- 9307 Web: vmw0neS1opCoo11ng.com License: CAC032444
For: Ryyan Homes
5349 OAKLAND LAKE
Notes:
Weather:
Winter Design Conditions
Outside db 42 OF
Inside db 68 cF
Design TD 26 cF
Heating Summary
Structure
17290
Btuh
Ducts
1765
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
19055
Btuh
Infiltration
Method
Simplified
Construction quality
Average
Fireplaces
0
Heating Cooling
Area (ft2) 1838 1838
Volume (ft3) 15991 15991
Air changes/hour 0.38 0.20
Equiv. AVF (cfm) 101 53
Heating Equipment Summary
Make Goodman Mfg.
Trade GOODMAN; JANITROL; AMANA DISTI...
Model GSZ140301 K -
AHRI ref 7995113
Efficiency
Heating Input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 33 °F
8.2 HSPF
FT. PIERCE, FL
Pierce, FL, US
27800 Btuh @ 47
0 cfm
0 cfm/Btuh
0.50 in H2O
Calculations approved byACCAto
Job: Lot 071 F1833 B LHG Den
Date: 04/17/2018
By. XF/RI/MC
Summer Design Conditions
Outside db
90
cF
Inside db
72
cF
Design TD
18
OF
Daily range
M
Relative humidity
50
%
Moisture difference
68
gr/Ib
Sensible Cooling Equipment Load Sizing
Structure
17361
Btuh
Ducts
3492
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data n
Rate/swingg multiplier 0.95
Equipmentsensibleload 19810 Btuh
Latent Cooling Equipment Load Sizing
Structure
3259
Btuh
Ducts
899
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
4158
Btuh
Equipment Total Load (Sen+Lat)
23968
Btuh
Req. total capacity at 0.75 SHR
2.2
ton
Cooling Equipment Summary
Make Goodman Mfqq.
Trade GOODMAN;JANITROL;AMANADIST]...
Cond GSZ140301 K
Coil ARUF31 1314A
AHRI ref 7995113
Efficiency 12.0 EER,14 SEER
Sensible cooling 21000 Btuh
Latentcooling 7000 Btuh
Total cooling 28000 Btuh
Actual airflow 933 cfm
Airflowfactor 0.045 cfm/Btuh
Static pressure 0.50 in H2O
Load sensible heat ratio 0.83
all requirements of Manual J 8th Ed.
- wrigFrrtsoft® I 2018-Aug-1010:36:51
^�^•� ww -�� P Right-SnriteOUniversal 201818.0.19 RSU23249 II Page 1
ACCA ...or\Desktop\TEMP\Lot071 F1 833 8 LHG Den- W.rLp Calc=MJ8 Front Door faces; W
-P�1- wrightsoft Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629- 6920 Fax: (407) 629- 9307 Web: wwwOreStopCooling.com License: CAC032444
Job: Lot 071 F1833 B LHG Den - W
Date: 04/17/2018
By: XF/RI/MC
1
Room name
Entire House
MBED
2
Exposed wall
157.5 ft
31.0 It
3
Room height
8.7 ft d
8.7 ft heaUmol
4
Room dimensions
14.0 x 17.0 ft
5
Room area
1838.0 it'
238.0 ft2
Ty
Construction
U-value
Or
HTM
Area (fCrj
Load
Area
Load
number
(Btuh>tnfl
(BtuW)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
I Gross
N/P/S
Heat
Cool
Gross
N/PiS
Heat
Cool
6
W _
13A-flocs. _ „ _ _
__ 0.143
n .-
_ _ 3.72
.._ _2.62
418
- . - 418
.. 553
--
_. . __1093
148
- 148
_ _550
387
VI!
13A-4ocs
0.143
a
3.72
2.62
265
196
730
514
0
0
0
0
)�-(p
4A5-2om
0.540
e
14.04
34.14
49
0
688
1674
0
0
0
0
11 DO..
0.390
e
11.50
20
20
204
231.
0
0
-0.
_ _ 0
11
_ _ • _ _
13A-flocs
0.143
_ -
s
_ -10.14
3.72
2:62
248
232
861
- . _ ,
606
_
0
0
_
0
,
0
.4A52om,..... __.. .-.
_._.-._0.540
_s-
1A.04.
14.36
..-- __i6
16
229
_ _ 235
... _... _.:0
, . _. - -.0
_ ._. 0
_ - 0
13A-4ocs
0.143
w
3.72
2.62
439
337
1252
881
122
89
331
233
4A5-2cm
0540
w
14.04
34.14
49
0
688
1674
33
0
459
1116
4A5-2omd
0.630
w
16.38
42.09,
54
0
878
2256
0
_ 0
0
0
P -
12C-Osia
0.091
.
_
2.37
_
1.33
.
344
_
326
_
771
433
0
0
6
0
-D
11D0...._.-_ ._ __ -
..-._ 0.390
-n-.
10.14
_.11.50
_--.18
_._. A8-...
.._181
-. 206.
----.._0
-_ -_.0:
- _0
_ _ 0
C
1613-30ad_
0.032
0.83
1.70
1838
1838
.,,_ 1529
_ 3117
--. 238
_ 238,
, _ 198
404_
_,-
_
30.68
_ -
. ;0.00
1838
_. .156
4M2
_ 0
. _ _ 238
31
_ .951,
_ 0
c) AED excursion
I
768
306
Envelope loss/gain
I
14396
13686
2489
2445
16
12
a) Infiltration
I
2894
1054
570
208
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
I 4
920
2
460
Applianceslother
1700
0
Subtotal (lines 6 to 13)
I
17290
17361
3059
3113
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17290
17361
3059
3113
15
Duct loads
10/
20%
1765
3492
10%
20%
312
626
Total room load
I
19055
20853
1
3371
3739
Air required (dm)
01
933
0
167
ACCAto meet all requirements of Manual J 8th Ed.
-�"�- wrYghtsoft�
Right-SLiteO Uriversal 201818.0.19 RSU23249
...or0esktop\TEMP\Lot071 F1 833 B LHG Den- W.np Calc=W8 Front Door faces: W
2018-Aug-1010:36:51
Page 1
-- wrightsoft° Right-J® Worksheet Job:
Entire House Date:
One Stop Cooling and Heating By:
7225 Sandscove Court, Winter Park, FL 32792 Ptnre: (407) 629 - 6920 Fax: (407) 62 - 9307 Web: wwwOneStopCooling.com License: CAC032444
Lot 071 F1833 B LHG Den - W
04/17/2018
XF/RI/MC
1
Room name I
NBTH
NNdIC
2
Exposed wall
14.5 It
0 It
3
Room height
8.7 It heaV000l
8.7 It heaVcool
4
Room dimensions
1.0 x 109.5 It
6.5 x 10.5 It
5
Room area
109.5 ft2
68.3 ft2
Ty
Construction
U-value
Or
HTM
Area (ftl
Load
Area
Load
number
(BtuhACiIn
(BtuhRt2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
I Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W-_
13A=flocs
0.143
_n.
. . 372
_ 2.62
_. _ 126
. _126
_ _ ... 469
,- - ,330
.. _. _ 0
0
_ .. 0
_ __0
- _
1N
._ .. _
13A-4ocs
0.143
a
3.72
2.62
0
0
0
0
0
0
0
0
4A5-2om
0.540
e
14.04
34.14
0
0
0
0
0.
0
0
0
::G
L-p
11DO,.
a
10.14.
11.50
0
0
0
0
0
0
0
0
11
...
13A-flocs
.0.390
0.143
s
372
2.62
0
0
0
0
0
0
6
0
4A5-2om_ _
_. 0.540
._S
14.04
•_ _14.36
'..0
.. _. .0
_ .._ .._0
--0
.._ 0
._.. 0
_ -_0
0
.G
13A-flocs
0.143
w
3.72
2.62
0
0
0
0
0
0
0
0
4A5-20m
0.540
w
14.04
34.14
0
0
0
0
0
0
0
0
4A5-2omd
0.630
w-
16.38
42.09
0
0
0
0
0
0
A.
0
I
P�-D
_
_0
0
-
1DO,--.._ __. _.
_0.90_
n_
__. 10.14
__.11 0
_0
- - -.__0
._ _ .0-_--
-0
_ _ _ -0
_0
C
161330ad_
0.032
--
0.83
110
-. - 110.
- , 91.
186
. _ .. 68
_ 68
, 57
116
- _
F
22A-cpm - - -
_
1,160
-
30,68
_1_.70
0.00
. . ,
110
. _
- _.. .-15
- - - 445
_ _ 0
.. 68
0
0
.. _ A
6
c) AED excursion
I
-50
-9
Envelopeloss/gain
I
1005
466
57
106
12
a) Infiltration
266
97
0
0
b) Room ventilation
1 I
0
0
0
0
13
Internal gains: Occupants @ 230
I 0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
I
1271
563
57
106
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1271
563
57
106
15
Duct loads
10 %
20%
130
113
10%
20 %
6
21
Total room load
I
1401
676
63
128
Air required (dm)
0
30
0
6
Calculations
J 8th Ed.
-Odd- wvlghtn wme I I 2018-Aug-1010.36:51
A Right -Suite® Universal 2018 18.0.19 RSU23249 Page 2
....ADesktop\TEMP\Lot071 F18338LHGDen -W.rg7 Calc=MJ8 Front Door faces: W
-f'�- wrightsofr Right-JO Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Coin, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: v wuOnestopCoolirg.com License: CAC032444
Job: Lot 071 F1833 B LHG Den - W
Date: 04/17/2018
By: XF/RI/MC
1
Room name
DEN
FOY
2
3
E)posed well
Room height
30.0 ft
8.7 Itheattcool
5.5 It
8.7 It heaUmol
4
Room dimensions
13.5 x 13.0 It
5.5 x 9.0 ft
5
Room area
175.5 ft2
49.5 ft2
Ty
Construction
U-value
Or
HTM
Area (its
Load
Area
Load
number
(Btuh4l2-`F7
(Btuh*)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P)S
Heat
Cool
6
W_.. ...
VIl
13A-flocs_ _ .
13A-4ocs
4A5.2cm
_..0.143
0.143
0.540
n
a
a
3.72
3.72
14.04
2.62
2.62
34.14
.. ._113
117
16
113
101
0
.. 421.
376
229
-- 296
265
558
_.... _ -0,
48
0
_-0
28
0
_ - _._0
103
0
-.--___.0
73
0
L�(p;
11
11D0_ -
13A-4oaS
0.390
0.143
a
s
10.14
3.72
11AP
� 2.62
-0
30
_ 0
3o
0
113
0
80
20
0
20
0
200
4
_ _231
- 0
V -
_ __ _
4A52om . __ .. __.
_ . _ _OS90
-.._s _
._ . 14.04
__1.4.36
.. _ __0
_--_---_0.
_ _ . 0.
_ .0
0
l _-.0
_ . ..__U
_ .0.
WW
�-G
13A-40cs
4A5.2om
0.143
0.540
w
w
3.72
14.04
2.62
34.14
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
I�
P -
_-
C
4A5-2omd
12C-Osw
.11 DO. .. _ .. . _ -- -
168-30ad
0.630
0.091
- - . _ .0.390
0.032
_ w
n _
16.38
2.37
_ ._10.14
0.83
42.09
1.33
.._ _ 11.50
1.70
0
0
_ -- _-0
_ 176
0_
0
__O
176
0
0
.. -- - .0
146
0
0
_ _ _ .._ -0
_298
0
0
_ _ , 0
50
0
0
.. -0
50
0
0
41
0
- 0
- 84
F=4?m
-
1.180
30.68
0.00
-
_. . 176
- _ , .-30
_- 920
_ 0
50
_6
169
0
6
c) AED excursion
I
1
-35
Envelope loss/gain
I
2205
1497
517
353
12
a) Infiltration
I
551
201
101
37
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
I 0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
I
2757
1698
618
390
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
237
149
-618
-390
14
Subtotal
2993
1847
0
0
15
Duct loads
10%
20%1
372
10%
20%1
0
0
Total room load
I
3299
2219
0
0
Air required (cfm)
0
99
0
0
Calculations aDDroved bvACCAto feet all requirements of Manual J 8th Ed.
- wrigF�tsoT�^ I 2018-Aug-1010:36:51
""- Right-Sute®Universal 2018 18.0.19 RSU23249 Page 3
...or\Desktop\TEMP1Lot071F1833BLHGDen-W.np Calc=W8 Front Door faces:W
-�+ wrightsoft Right-J® Worksheet Job:
Entire House Date:
By.
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopGooling.com License: CAC032444
Lot 071 F1833 B LHG Den - W
04/17/2018
XF/RI/MC
1
Room name
DIN
KIT
2
3
ExposedvAl
Room height
15.0 ft
8.7 ft heaUcool
0 ft
8.7 ft heaU000l
4
5
Room dimensions
Room area
11.5 x. 12.5 it
143.8 ft'
1.0 x 297.8 ft
297.8 f12
Ty
Construction
number
U-value
(Btuh4tzco
Or
HTM I
(Btuh/V)
Area (fl
or perimeter (ft)
Load
(Btuh)
Area (ff2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/PS .
' Heat
Cool
Gross
N/PS
Heat
Cool
6
11
_w
W
13A flocs- _
13A-4ots
4A5-2om
11DO • .--
13A-46cs
4A5-2om .._ .-__.,
13A-4ocs
4A5-2om
4A5.2omd
12C Osw
11DO __.- _._ _..
168,30ad _ _ - - _
22A gym., - _ - _ .-.:.
_ 0.143
0.143
0.540
0.390
0.143
°_.0.540
0.143
0.540
0.630
0.091
0.390
0.032
1.180
_ n.._
a
a
e
s
_s-._
w
w
w_
n.
-
_ 3.72
3.72
14.04
_ _ 10.14
3.72
14.04
3.72
14.04
16.38
2.37
10.14
0.83
30.68
_ _ 2.62
2.62
34.14
11.50
2.62
1436
2.62
34.14
42.09
1,33
11.50
1.70
0.00
_- -30
100
33
_0
0
.--- - :-0.----
0
0
0
109
:0'-
144
. 144
_ ... 30
67
0
.0
0
-_0
0
0
- 0
109
. -._0
144
15
_ _ 113
250
459
-. 0
0
:..._. 0
0
. 0
-0
257
. _. __.0.
_ 120
- 460
80
176
1116
- 0
0
-__ -----0
0
0
0
144
. -.A.
._ 244
_ 0
- 0
0
0
.- -_ ...0
0
._....----0
0
0
- 0
61
.._ __.0
- -- ,. 298
. __ 298
_.... _ _ - 0
0
0
0
0.
--. - 0
0
0
0
61
_ __0
_ . - 298
0
_ : 0
0
0
0
0
_, ._. .0
0
0
_ 0
144
_ 0
248
. 0,
0,
0
0
.. -0
0
__. ....0
0
0
- 0
81
. A
_ , 505
0
��--GG
-G
PI
LJ
C
F
6
c) AED excursion
I
128
-146
Envelope loss/gain
I
1660
1888
392
439
12
a) Infiltration
276
100
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
I 0
0
0
0
Applianceslother
0
1200
Subtotal (lines 6 to 13)
I
1935
1988
392
1639
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
237
149
145
91
14
Subtotal
2172
2138
536
1731
15
DUdloads
10%
20%
222
430
10%
20%
55
348
Total room load
I
2394
2568
591
2079
Air required (dm)
0
115
0
93
ACCAto meet all requirements of Manual J 8th
- wr`igtitsoft� 2018-Aug-1010:36L1
"' " ^ Right -Suite® Universal 201818.0.19 RSU23249 Page 4
...or\Desldop\TEMP\Lot071 F1833BLHGDen -W.rLp Calc=MA Front Door face W
wrightsoft, Right-JO Worksheet Job:
Entire House Date
By:
One Stop Cooling and Heating
7225 Sandscove Cart, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 62 - 9307 Web: wmmOneStopCooling.com License: CAC032444
Lot 071 F1 833 B LHG Den - W
04/17/2018
XF/RI/MC
I
Room name
GRT
BTH1
Exposed vdl
16.5 ft
6.0 It
Room height
8.7 It heaV000l
8.7 ft heaV000l
4
Room dimensions
. 16.5 x 15.5 It
1.0 x 79.5 It
5
Room area
255.8 ft2
79.5 ft2
Ty
Construction
number
U-value
(Btuh4t2-F)
Or
HTM
(Btuh/ft2)
Area (ft1)
or perimeter (ft)
Load
(8tuh)
Area
or perimeter (ft)
Load
(Btih)
Heat
Coal
Gross
N/PVS
Heat
Cool
Gross
N/P)S
Heat
Cool
6
11
W.
-f3A ----------- ------
-4cas,
13A-flocs
4A5-tom
11D0
13A-flocs
.2om
4A5,
13A-4ocs
4A5-tom
- - -
0.143
0.143
0.540
0.390
0.143
0.540
0.143
0.540
-'__n
e
e
e.
s
--.S��
w
w
3.72
3.72
14.04
1.0.14
3.72
14.04
3.72
14.04
- 2.621
2.62
34.14
11.50
2.62
1.4.36
2.62
34.14
6
0
0
-0
0.
-1- . ..... 0
144
0
0
0
0
0
0
.. ... --.-..o
90
0
0
0
0
0
334
0
_0
0
0
0
0.
235
0
_13
0
0
.0
0
.._0
52
0
0
0
0
0
0
. ...-0
52
0
_0
0
0
0
b
--- -01
194
0
Q
T 0
0
0
o
__0
137
0
v
P
-.L-LD.
C
4A5-2omd
f2C-Os�i
11D0---
1613-30ad
040
0 _ .091
0.390
0.032
1,180
w
-n
r
16.38
2.37.
10.14
0.83
k68•
42.09
1,33
11.50
1.70
-6.00
514
0
--A
256
256
-0.
0
-.-.0
256
17
.878
0
-- __0
213
5 - 06
2256.
0
__0
434
0
----------
.0
b
80
8 0
0
0
__0
80
6
0
0
--o
66
184
-0
0
___0
135
0
6
c) AED excursion
I
626
-26
Envelope loss/gain
I
1931
3551
444
246
12
a) Infiltration
I
303
110
110
40
b). Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
I
0
0
0
Appliancestother
01
0
Subtotal (lines 6 to 13)
2235
3661
555
286
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
5
9
8
15
14
Subtotal
22391
3670
563
301
15
Ductloads
10%
20%
M
738
10%
20%
57
61
Total room load
24158�
44081
620
362
Air required (dm)
0
197
0
16
Ed.
2018-Aug-10 10:36:51
:MA Right -Suite® Uriversal 2018 18.0.19 RSU23249 I Page 5
....r\Desldop\TEMP\Lot 071 F1 833 B L.HG Den- W.rLp Calc = W8 Front Door faces: W
wrightsoft, Right-J@ Worksh et
Entire House
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0naStopCooling.com License: CAG032444
Job: Lot 071 F1 833 B LHG Den - W
Date: . 04/17/2018
By. XFIRI/MC
I
Room name
BED2
AC
2
Exioosed well
26.0 ft
0 ft
3
Room height
8.7 it heat/cool
8.7 it heat/bool
4
Room dimensions
1.0 x 160.5 ft
5.5 x 3.5 ft
5
Room area
160.5 ft2
19.3 it'
Ty
Construction
U-value
or
HTM
Area
Load
Area
Load
number
(BtuWfl
(Btuh/V)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/BS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
j3A
6343
3--T2
0
_0
0
0
-0
. 0
0-
13A-4ocs
0.143
e
3.72
2.62
0
0
0
0
0
0
0
0
4A5-tom
0.540
e
14.04
34.14
0
0
0
0
0
0
0
0
11D0
0490
e
10.14
11.50
0
0
a
0
0
0
0
"0
0
1' 1
13A-4ocs
0.143
- s
3.722m
-'-104
'1&
388
273
0
0
G
..4A5-2om..-
-.0540
-s.
-14.04
--- 14.36
.-..-o
0
0
-0,
-__0
13A-flocs
0.143
w
3.72
2.62
122
105
392
276
0
0
0
0
4A5-2om
0-w
w
14.04
34.14
16
0
229
558
0
0
0
0
4A5-2cmd
0.630
16.38
42.09
0
0
0
0
0
0
- 0
R
i 2C-0sw
1. 0.091
-w
2.37
1.33
.0
-0
0
.L-D
C
IlDb.-
1613-30ad
.-0,396
0.032
-n
-10.14
0.83
--.1150
1.70
-.-b
161
---0
161
-26
134
-0
272
19
.0
J9
-.0
J.6',
.0
._33.
22A-cpm__
1.180
798
- 0
.. .. .... ..
-19
0
0
0
6
c) AED excursion
I
122
-3
Envelope losstgain
I
1941
1501
16.
30
12
a) Infiltration
478
174
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
I 1
230
0
0
Appliancestother
0
0
Subtotal (lines 6 to 13)
I
2419
1905
16
30
Less external load
0
0
0
0
Less transfer
0
0
0
0.
Redistribution
5
9
-16
-30
14
Subtotal
2423
1914
0
0
15
Duct loads
10%
20%
247
385
10%
20%
0
0
Total room load
I
2671
2299
0
0
Air required (cfm)
0
1031
0
0
Calculations approved byACCAto meet all
Right-SLiteGUriversal20l8l8.0.19RSU23249
....rTesktop\TEMP\Lot071 F1833 8 LHG Dan- W.rup Calc=MJ8 Front Door faces: W
2018-Aug-10 10:36;51
Page 6
wrightsoft' Right-JO Worksheet Job:
Entire Mouse Date:
By:
One Stop Cooling and Heating
7225 Sandscove Court, Willer Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOmStopCooling.com License: CAG032444
Lot 071 F1833 B LHG Den - W
04/17/2018
MUM
1
Room name I
BED3
LAUN
2
E>posed wall
13.0 It
0 It
3
Room height
8.7 ft heatt000l
8.7 it heaUmol
4
5
Room dimensions
Room area
1.0 x .1562 It
156.3 it'
1.0 x 51.3 It
51.3 ftz
Ty
Construction
number
U-value
(Btuw
Or
HTM
(Btuh/ft2)
Area ("
or perimeter (ft)
Load
(Btuh)
Area (ft)
or perimeter (it)
Load
(Btuh)
Heat
Cool
I Gross
N/P/S
Heat
Cool
Gross
NOS,
Heat
Cool
6
W ..
-
13A,4ocs
13A-4ocs
4A5-2om
. 6.143
0.143
0.540
' n
a
e
_3.72
3.72
14.04
--
.zu
2.62
34.14
0
0
0
.- _ - . _0
0
0
0
0
0
0
0
-
_ . 0
0
0
-- -
0
0
0
- -
0
0
0
0
0
0
11
11DO
13A-4ocs
0.390
0.143
a
s
10.14
3.72
1150
2.62
_ 0
113
0
.97
0
360
0
253
0
0
0_
0
0
0
0
0
-4A5-2om __
13A-4ocs
4A5-2om
0540
0.143
0.540
._ s .
w
w
_ _.. 14.04
3.72
14.04
__ _14.36
2.62
34.14
.16
0
0
_ .._ .16
0
0
229
0
0
. _ 235
0
0
_ . _ -0
0
0
---.0
0
0
. - 0
0
0
.0
0
0
U�
�--G
Imo_ a_
P
4A5.2omd
12C-0sw
0.630
0.091
w
-
16.38
2.37
42.09
1.33
. 0
117
0
117
0
278
0
156
0
57
0
' 39,
0
92
0
51
1--D
_11D0_ ._
1613-30ad
0.390
n_
, -.
_ 10.14
. 0.83
_1150
--1.70
.. _.._0
1.56
._ _0
1.56
_. 0
- 130
_... . -0
265
_18
- 51
18
51
181
43
._ 206
87
C ..
_ _
F
22A-cpm
_0.032
1.180
-
_
30.68
-0.00
156
13
899
0
51
- 0
0
0
6
c) AED excursion
-71
-69
Envelope loss/gain
I
1396
838
315
275
12
a) Infiltration
I
239
87
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Ooaipants@ 230
1
230
0
0
Appliancesrother
0
500'
Subtotal (lines 6 to 13)
I
1635
1155
315
775
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
13
24
13
24
14
Subtotal
1648
1179
328
799
15
Ductloads
100/0
201/.
168
237
10%
201/6
34
161
Total room load
I
1816
1416
362
960
Air required (dm)
0
63
0
43
-- -tr}+- wr7-91mtsCxTk- I 2018-Aug-1010:36:51
Af8A Right-Sute@Universa12018 18.0.19 RSU23249 Page 7
or\Desktop\TEMP\Lot071F1833BLHGDen- W.np Calc=W8 Front Door faces :W
wrightsoft° Right-M Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandscove Coot, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: WVAUOneStopCooling.com License: CAC032444
Job: Lot 071 F1833 B LHG Den - W
Date: 04/17/2018
By: XF/RUMC
1
Room name
H1
2
Exposedvdl
0 ft
3
Room height
8.7 it heal/cool
4
Room dimensions
9.5 x 3.5 It
5
Room area
I 33.3 ftz
Ty
Construction
number
U-value
(BtuhAC-9
Or
HTM
(Btuh/ft2)
I Area (M
or perimeter (it)
Load
(Btuh)
Area
or perimeter
Load
Heat
Cool
I Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
1N
13A:4ocs_ - - --
13A-4ocs
4A5-2om
.. 0.143
0.143
0.540
,n -
a
a
3.72
3.72
14.04
2.62
2.62
34.14
0
0
0
_ ... -- - 0
0
0
-. - 0
0
0
_
_ ...._0
0
0
_
11
11 DO
13A-4ocs
0.390
0.143
e
s
10.14
3.72
- 11,50
2.62
0
b
0
0
0
0
0
6
—G
4A5-2om-- -- —._
13A-40 s
4A5-2om
_._. _ _0.540
0.143
0.540
_s
w
w
_.. 14.04
3.72
14.04
.,. ,.14.36
2.62
34.14
_ .0'—
0
0
0
0
0
0
0
0
_ 0.--
0
0
PI
�—U
C
4A5-2omd
12C-Osw
11D0_ __.
1613-30ad
_ .- ..0.630
0.091
0.390
0.032
, w -
-
_n-
16.38
2.37,
-10.14
0.83
_ 42.09
1.33
.11M
1.70
_0
0
___0...
33
- 0
0
_.. _0
33
0
0
_ 0
28
0
0
.0
56
F .
22A-cpm -
_ 1.180
-
30.68
0.00
7.
33
0
_ . 0
.. _ 0
6
c) AED excursion
I
-5
Envelope loss/gain
I
28
52
12
a) Infiltration
0
0
b) Roam ventilation
0
0
13
Internal gains: Occupants@ 230
0
0
Appliances(other
0
Subtotal (lines 6 to 13)
I
28
52
Less external load
0
0
Lesstransfer
0
0
Redistribution
-28
-52
14
Subtotal
0
0
15
Dudloads
10%
200/6
0
0
Total room load
I
0
0
Air required (dm)
0
0
iACCAto meet all requirements of Manual
`rl'F wr Y-gtitso� I 2018-Aug-101036:51
. A Right -Suite® Universal 2018 18.0.19 RSU23249 Page 8
..or\DesMop\TEMP\Lot071 F1833 8 LHG Den- W.np Calc= W8 Front Door faces: W
Static Pressure and Friction Rate Job: Lot 071 F1833 B LHG Den
-�- wrightsoft® Date: 04/17/2018
Entire House I By. XF/RINC
One Stop Cooling and Heating
7225 Sandsoove Coot, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wm0neStopCooling.com License: GAC032444
For: Ryan Homes
5349 OAKLAND LAKE CIR, FT. PIERCE, FL
it
Heating
Cooling
(in H2O)
(in H2O)
External static pressure
0.50
0.50
Pressurelosses
Coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
Available static pressure
0.34
0.34
Total•
Supply
Return
(ft)
(ft)
f Measured length of run -out
9
0
Measured length of trunk
20
0
Equivalent length of fittings
120
0
- Total length
149
0
Total effective length
149
FrictionRate
Heating
Cooling
(in/100ft)
(in/100ft)
Supply Ducts
0.228 > 0.18
0.228 > 0.18
Return Ducts
0.228 > 0.18
0.228 > 0.18
Fitting Equivalent LengthDetails
Supply 4X=35,11 A=20,11 G=5,11 G=5,11 G=5,1 A=35,11 G �5,11 G=5,11 G=5: Total EL=120
Return TotalEL=0
I
-�- wrightsoft, I
I . ..wN., , Right-SLdte®Universal 201818.0.19RSU23249
ACCA ...or\Desktop\TEMP\Lot071 F1833 8 LHG Den-W.np CaIG=W8 FrontDcoriaces: W
I
I
2018-Aug-101006:52
Page 1
r
- wrightsoft® Duct System Sun
Entire House
One Stop Cooling and
7225 Sandscove Coot, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407)
9307 Web: wwwOmStopCooling.cromLicense: CAC032444
For: Ryan Homes
5349 OAKLAND LAKE CIR, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply/return available pressure
Lowest friction rate
Actual air flow
Total effective length (fEL)
Heating
0.50
in H2O
0.16
in H2O
0.34
in H2O
0.170 / 0.170
in H2O
&228
in/100ft
0
cfm
149 ft
Job: Lot 071 F1833 B LHG Den
Date: 04/17/2018
By. XF/RUMIC
Cooling
0.50 in H2O
0.16 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.228 in/100ft
933 cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BED2
c 2299
0
103
0.291
6.0
Ox0
VIFx
12.0
105.0
sti
BED3
c 1416
0
63
0.301
6.0
Ox0
VIFx
12.8
100.0
st1
BTH1
c 362
0
16
0.262
4.0
Ox 0
VIFx
15.0
115.0
sti
DEN
c 2219
0
99
0.233
6.0
Ox 0
VIFx
36.2
110.0
st2
DIN
c 2568
0
115
0.231
6.0
Ox 0
VI Fx
37.2
110.0
s2
GRT
c 4408
0
197
0.228
8.0
Ox 0
VIFx
29.2
120.0
st2
KIT
c 2079
0
93
0.253
6.0
Ox 0
VIFx
24.6
110.0
st2
LAUN
c 960
0
43
0.466
4.0
Ox0
VIFx
3.0
70.0
IMBED
c 3739
0
167
0.230
7.0
Ox 0
VIFx
32.8
115.0
st2
MBTH
c 676
0
30
0.239
4.0
Ox 0
VIFx
32.5
110.0
st2
MW lc
c 128
0
6
0.249
4.0
Ox 0
VIFx
26.8
110.0_
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
PeakAVF
0
708
0.228
6621
14.0
0 x 0
VinlFlx
sti
PeakAVF
0
182
0.262
683
7.0
0 x 0
VnIFIX
-- wrightsoft® I 2018-Aug-1010:36:52
Right-Sute® Universal2018 18.0.19 RSU23249 Page 1
ACCA ...or\Desktop\TEMP\Lot071 F1833BLHGDen -W.rup CaIc=W8 Front Door faces: W
Grille
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Mat
Trunk
rbi
Ox 0
0
933
0
it 0
0
0
Ox 0
VIFx
A R C H I T E C T S
SCANNED
BY
J .i
ign
p Inc.
7/23/18
City of Port St. Lucie
Building Department
Plan Review Div.
RE: Oakland Lake (Lot 71) 1833 Model,
1. Window in Owner's Suite Bath was removed
2. Owners Suite bedroom wall moved in 4" aInd room size changes from 12'-10"x 16'-6" to 12'-6"x 16'-
6"
3. Shower in Owner's Suite change from a Recess shower to a shower pan.
4. The roof over the garage changes from a Hip roof to a Gable roof
Should you have any questions regarding this letter, ado not hesitate to call me.
Sincerely,
J 2 3 2018
James twell
Flor' a rchitect 412079
1441 N. Ronald Reagan Blvd. • Longwood, FL 32750 • Phone: (407) 774-6078 - Fax: (407) 774-4078
AA00,03325