Table Deck Application Type Description Page
1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5
113-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9
1B-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11
1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 11
11)
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
1F-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
-` 1F-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
19-21
( - 1Gi
i..
iWood )
New or Reroof Tear-O '
f, (� .�,
iF;.
(Non=lnsula'ted Bonded -Roof Cover'j
(21
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
48
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
49
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
49'
----Reroof-(-Tear-Off)__
_ _A-i
Bonded Insulation, Bonded Roof Cover
50-52
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded -Roof -Cover - -- — --- -
- — - - - - 52- _ -
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
6D
Gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A Various
713 Various
Recover A-1 Bonded Insulation, Bonded Roof Cover
Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
54-58
58
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation /base sheet fasteners shall be of sufficient length for the following deck engagement: FILE
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, U.C. d/b/a Trinity ERD Evaluation Report P9290.02.08-1120 for 171.3654-1122
Certificate of Authorization t19503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
�. ➢ Millennium PG-1 Pump Grade Adhesive (M-PGI): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanu rate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed fora particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL)
➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
➢ ICP Adhesives & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
8. Bonded polyisocy-tnurate iosulationboardsshall-be-maximum-4-x-4-ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report P9290.02.08-R20 for FL3654-R22
Certificate of Authorization #9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 2 of 58
Q"'TRINITYIERD
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications
TABLE 1: POLYGLASS_ROOF. COVERS'
Reference
Layer
Material
Application
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
(Base and Ply sheets, Asphalt-
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Hot Asphalt at 20-40
Ibs/square
Applied)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes.
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type 11, Polyglass HT Base 650
SBS-CAi
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
PG350 at 1.5-2.0
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type 11
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
Polyplus 35 at 1.5-2.0
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
S6 Type II, Polyglass HT Base 650
SBS-AA
Hot Asphalt at 20 40
(SBS, Asphalt Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
Ibs/square
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes.
Base Ply or Ply
One
0 or more plies Elastobase (sand/poly), Elastobase (poly/poly),.Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base
SBS-TA
_(SBS, Torch -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
Torch -Applied
Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
APP-CA1
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
--gal/square--
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Poylex,_Polybond
_(APP, Torch -Applied)
Cap Ply—
—PbWdx, Pol (flex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Torch -Applied
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP-SA
(APP, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates forAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance.
associated with coating usage.
➢ PG200 Non Fibered Roof Coating;
PG300 Fibered Roof Coating;
➢ PG600 Nan-Fibered Aluminum Roof Coating;
PG650 Fibered Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
➢ PG700QS (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only);
➢ PG800 Asphalt Emulsion Roof Coating;
➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
➢ Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or SBS only);
➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, L-C. d/b/a Trinity) ERD
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Refer to current Roofing Materials Directory for fire ratings
Evaluation Report P9290.02.08-R20 for FL3654-R22
Revision 20: 09/12/2017
Appendix 1, Page 3 of 58
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MOP listings below vs. those in Table 3A
applies:
VAPOR BARRIER OPTIONS; STRUCTURALCONCREfEDECK; ADHERED INSULATION PER TABLE 3A _ ......... .....�_ . , _ . _... .... ... , .d., ,.3..__.. _ .. ...
Option #
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
Type
Attach
VB-1.
PG100
Elastoflex SA V Plus
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
VB-2.
PG100
Polyglass APP Base
Torch -applied
Inta-Stik or CR-20,12-inch o.c.
-75.0
VB-3.
PG100
Elastoflex SA P
Self -Adhering
Insta-Stik,12-inch o.c.
-75.0
VB-4.
PG100
Elastoflex SA P
Self -Adhering
Millennium One Step Foamable Adhesive,12-inch o.c.
-157.5
VB-5.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-6.
PG100
Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20,12-inch o.c.
-290.0
19. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL3654-R22
Certificate of Authorization H9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 4 of 58
C)o
`J TRINITYIERD
-TABLE IF 2i• WOOD DECKS`=NEW CONSTRUCTION, REROOF°(Teaii-OFF) o12RECOVi
SYSTEM TYPES` NON -INSULATED, MECHANICALLY ATfACHEO,BASE SHEET (scREws'& PLATES), BONDED ROOF'COVER
.._
System
Deck
Base Sheet
Roof Cover (Note 15)
MDP
No.
(Note 1)
Type
Fasten
Attach
Base Ply
Cap
(psi
e SELF-ADHERwd BASE PLY:`'',
_ ___
.... "` �•
":.' v _ e
_ _
.,
W-136
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
52 5*
inch plywood
(poly -film top)
orTrufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
TA, APP TA
W-137
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
Polyflex SA Base
APP TA
-52.5*
inch plywood
(poly -film top)
orTrufast 3" Metal Insulation Plate withTrufast HD
(2), equally spaced, staggered center rows
W-138
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
-60.0*
inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
TA, APP-TA
W-139
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
Polyflex SA Base
APP-TA
60.0*
inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
JABLE 1G: WOOD DECKS=NEW CONSTRUCTION ogRERO,OF (TEAR -,OFF
SYSTEM TYPE F�NON-INSULATED, BONDED ROOFyCOVER
System
Roof Cover (Note 15)
No.
Deck (Note 1)
Primer
MDP (psf)
Joint Treatment
Base Ply
Ply
Cap Ply
iV11=140,
tWlin 15/32D;
None
i.N.9_ne
SBS-SAA
fOptional)'S85=SA;-SBS,
T"9�O.Os
SBS SA APP=SA; SBS=
TR; APP TA!
yin, cf� plywood,
{TA APP TA
W-141
Min. 15/32-
(Optional) PG100
None
Polyflex SA Base
(Optional) APP-TA
APP TA
-90.0
inch plywood
W-142
Min. 15/32-
PG100
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
97.5
inch plywood
TA, APP-TA
TA, APP-TA
W-143
Min. 15/32-
PG100_
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into _
Elastoflex SA V Base or
-(Optional).SBS-SA,SBS----
SBS-SA,-APP-SA,-SBS--SA
97.5
-- -
-inch plywood—
-(Optio_nal)
Place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA, APP-TA
W-144
Min. 15/32-
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
-105.0
inch plywood
TA, APP-TA
W-145
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
135.0
inch plywood
place to create continuous bond.
Elastoflex SA V Plus FIRTA,
APP-TA
TA, APP-TA
W-146
Min. 15/32-
O tional PG100
( p )
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Polyflex SA BaseI
Yf
(Optional) APP-TA
APP-TA
-135.0
i
inch plywood
place to create continuous bond.
Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 eH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58