Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLES12r-i2017 �} I Florida Building Code Online BCIS Home I Log In I User Registration I Hot I Submit Surcharge I Stats B Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I db,Pr a C� 1�' :p1 Product Approval SCAN W USER: Publi[ User �o GK�nur.V� qqqq Product Approval Menu > Product or c tirc >; IICat/Lis > Application Detail FL # FL10124-R20 Application Type Revision Code Version 2017 Application Status Approved Comments Archived G. RECEIVED — APR 05 2018 ST. Lucie County, Permitting Product Manufacturer GAF c�yf Address/Phone/Email 1 Campus Drive Parssppany, NJ 07054 (800) 766-3411 mstieh@gaf.com ST, LUCIE COUNTY BUILDING DIVISIO REVIEWED FOR COMPLIAN Authorized Signature Robert Nieminen REVIEW BY O 4a"*- lindareith@trinityerd.com DATE — f PLANS AND PERMIT MUST BEiKEPT ON JOB Technical Representative William Broussard SITE OR NO INSPECTIONS) WILL BE MADE Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category I Roofing Subcategory Asphalt Shingles I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer CG Evaluation Report - Hardcopy Received THESE PLANS AND ALL PROPOSED WOI Florida Engineer or Architect Name who developed the Robert Nieminen ARE SUBJECT TO ANY CORRECTIONS Evaluation Report REQUIRED BY FIELD INSPECTORS THAT Florida License PE-59166 CESSARY IN ORDER TO MAY WIITH Quality Assurance Entity UL LLC ALL APPLICABLE CODES Quality Assurance Contract Expiration Date 10/20/2018 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received I Certificate of Independence FL10124 R20 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year of Standard) ) I Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 TAS 107 1995 CONCEALED FASTENERS OR ATTACHMENTS FILE COPY Equivalence of Product Standar�RE THE RESPONSIBILITY OF THE Certified By . CONTRACTOR OR RECORD https://www.floridabuilding MQNZD6Zesy3BoOyLwXhMdCmfpylEOlvyCA%3d%3d 1/2 12/14/2017 Florida Building Code Online .4. Sections from the Cod. Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 09/20/?0 ' 17 09/27/2017 09/28/2017 12/12/2017 iurvirriary of Prkbid 7 '7­77 M odql,,,Num er.or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use j Installation Instructions Approved for use in HVHZ: No FL10124 R20 11 2017 09 FINAL ER GAF Asohalt Approved for use outside HVHZ: Yes Shinales FL10124-R20,Dd Impact Resistant: N/A I Verified By: Robert Nierninen PE-59166 Design Pressure: N/A I Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt Shingles FL10124-R20.r)d Created by Independent Third Party: Yes Or Contact Us 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State Or Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement Refund Statement Under Florida law, email addresses Ire re public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1,12012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe V AJA' https:lh,vww.floddabuilding.org/prlpr_appjti.aspx?param--wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpylEOlvyCA`/`3d`/`3d 2/2 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 TRINITY 353 CHRISTIAN STREET, IT ERD OXFORD, CT 06478 478 (203) 262-9245 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1122 1 Campus Drive FL10124-1120 Parsippany, NJ 07054 Date of Issuance: 01/03/2008 (800) 766-3411 Revision 22: 09/20/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida �uilding Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with j herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report referenced Quality Assurance documentation chat Acceptance of this Evaluation Report by the name( product changes or the referenced Quality Assu review of this Evaluation Report relative to update) ADVERTISEMENT: The Evaluation Report number pr advertising literature. If any portion of the Evaluat requirements the Accredited Quality Assurance Agency noted is valid until such time as the named product(s) changes, the ges, or provisions of the Code that relate to the product change. client constitutes agreement to notify Robert Nieminen, P.E. if the ance documentation changes.. Trinity) ERD requires a complete (Code requirements with each Code Cycle. (ceded by the words "Trinity I ERD Evaluated" may be displayed in �n Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: 'I : IT !-T' j 4J X. Robert J.M. Nieminen, P.E. s,l„pis! The facsimile seal appearing was authorized by Robert Nleminen, Florida Registration No. 59166, Florida DCA ANE1983 I ��` P.E. on 09/20/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquirelor will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor; Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. i. �.l TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Slingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 6 h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use setlforth herein. 2. STANDARDS: Section 1507.2.4 / 1507.1.1, R905.2.3 / R905.1.1 1507.2.5, R905.2.4 1507.2.7.1, R905.2.6.1 1507.2.7.1, R905.2.6.1 1507.2.7.1, R905.2.6.1 3. REFERENCES: Enti GAF (PDM 1915) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) PRI (TST 5878) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) U L (TST 1740) U L (TST 1740) U L (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) Exterior Research and Design, I.I.C. Certificate of Authorisation #9503 Property I Standard Year Physical Properties. ASTM D1970 2015 Physical Plperties ASTM D3462 2010 Wind Resistance ASTM D3161 2016 Wind Resistance ASTM D7158 2011 Wind Resistance TAS 107 1995 Letter of; Equivalency PhysicallProperties ASTM D3462 ASTM D3462 Physical Properties Wind Driven Rain ASTM D3462 ASTM D3462 TAS 107 ASTM D3462 ASTM D3161, TAS 107 ASTM ID3161 ASTM D3462 ASTM D3161, TAS 107 ASTM D3161, TAS 107 ASTM D3161 ASTM D3462 ASTM D3462 ASTM D3161 ASTM D3161 ASTM D3462 ASTM D3161 ASTM D3462 ASTM D3161 ASTM D3161, D3462 ASTM D3161, D3462 ASTM D3161, D3462 ASTM D3462 ASTM D3161, D3462 ASTM D3161 ASTM D3161 ASTM D3161 ASTM D3161, D3462 AI TM D3161, D7158, D3462 I Reference Seal -A -Ridge Impact Resistant IR GAF-025-02-01 GAF-059-02-01 GAF-080-02-01 GAF-324-02-01 GAF-407-02-01 93NK6295 99NK43835 94NK9632 01NK06632 01NK9226 01NK37122 01NK37122 02NK12980 02NK30871 03CA5367 03NK26444 04NK13850 04NK13850 04NK30546 04NK22009 04NK22009 05NK27924 05NK27924 06CA18077 06CA18074 06CA35251 06CA31603 06CA41095 07NK05228 06CA31611 06CA61148 07CA31742 08CA06100 6T" EDITION (2017) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Date 01/13/2012 03/27/2002 09/02/2004 05/25/2005 12/01/2011 01/21/2013 11/29/1993 01/12/2000 03/29/2000 02/02/2001 05/21/2001 12/18/2001 12/19/2001 04/10/2002 09/09/2002 03/11/2003 10/17/2003 06/07/2004 06/23/2004 03/10/2005 05/06/2005 05/09/2005 02/10/2006 02/11/2006 06/05/2006 06/16/2006 10/18/2006 12/01/2006 12/27/2006 03/13/2007 04/04/2007 04/09/2007 11/08/2007 03/13/2008 Evaluation Report 01506.01.08-1122 F1.10124-1120 Revision 22: 09/20/2017 Page 2 of 6 i Entity UL (TST 1740) UL (TST 1740) U L (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) 4. PRODUCT DESCRIPTION: ASTM D3161, E ASTM D3161, C ASTM D3161, E ASTM D3161, G ASTM D3161, C ASTM D3161, C ASTM D3161, C ASTM D3462 ASTM D3462 ASTM D3161, C ASTM D3161, C ASTM D3161, C ASTM D3161, E ASTM D3161, E ASTM D3161, E ASTM D3161, E ASTM D3161, C ASTM D3462 ASTM D3161, C ASTM D3161 ASTM D3161 ASTM D3161 ASTM D3161, C ASTM D3161, C Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control Quality Control 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal shingles. Reference 07CA55908 09CA10592 09CA06856 D3462 09NK06647 D3462 09CA27281 D3462 IOCA35554 D3462 IOCA13686 10CA07264 10CA11953 D3462 1ONK11951 D3462 1ONK12070 D3462 08CA06100 D3462 10CA53934 D3462 11CA48924 D3462 11CA47919 D3462 11CA48408 D3462 11CA48725 12CA34891 D3462 12CA58151 12CA38083 13CA32332 13CA37934 D3462 4786875675 D3462 4787434542 Inspection Report, R21, Mobile, AL Inspection Report, R21, Myerstown, PA Inspection Report, R21, Tuscaloosa, AL Inspection Report, R21, Michigan Cty, IN Inspection Report, R21, Shafter, CA Inspection Report, R21, Savannah, GA Inspection Report, R21, Minneapolis, MN Inspection Report, R21, Mt. Vernon, IN Inspection Report, R21, Baltimore, MD Inspection Report, R21, Tampa, FL Inspection Report, R21, Dallas, TX Inspection Report, R21, Ennis, TX Inspection Report, R21, Fontana, CA Date 04/01/2008 03/26/2009 05/15/2009 08/01/2009 08/27/2009 03/05/2010 05/15/2010 05/27/2010 10/29/2010 10/30/2010 11/04/2010 01/30/2010 03/31/2011 10/22/2011 12/03/2011 12/08/2011 12/09/2011 10/12/2012 02/15/2013 02/26/2013 06/18/2013 08/02/2013 07/17/2015 05/17/2016 10/25/2016 10/20/2016 11/11/2016 11/01/2016 11/17/2016 11/11/2016 10/25/2016 10/25/2016 10/21/2016 11/17/2016 11/04/2016 11/03/2016 11/01/2016 and Sentinel® are a fiberglass reinforced 3-tab asphalt roof 4.1.2 Camelot®, Camelot® II, Fortitude'"°, Glenwood'"', Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield'", Monaco®, Sienna®, Timberline® American Harvest®, Timberline® 'ArmorShield'" II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge Shingles: 4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShield'm Ridge Cap Shingles and T)mbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. I Exterior Research and Design, I.I.C. I Evaluation Report 01506.01.08-1122 Certificate oJAuthorizotion #9503 6'" EDITION (2017) FBC NON•HVHZ EVALUATION FL10124 R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 3 of 6 4.3 Accessory Starter Strips: 4.3.1 Pro -Start® Eave/Rake Starter: are starter strips for asphalt n 4.3.2 QuickStart® Peel & Stick Sta modified bitumen starter stril inch or less. -I TRINITY I ERD . -ip Shingles and WeatherBlocker'" Premium Eave/Rake Starter Strip Shingles f shingles. ar Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- 4.3.3 StarterMatchl Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatchT"° are installed as the second starter for Grand Canyon® and Grand Sequoia® series installations. S. LIMITATIONS: I 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not pa it of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5_4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to VLd = 150 mph (V,,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to VaSd =150 mph (Vint=194Imph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles or Starter IStrio: 6.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Exterior Research and Design, U.C. Evaluation Report 01506.01.08-R22 Certificate ofAuthorizatlon #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 4 of 6 TRINITY I ERD 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal -A -Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". 11.5" Sealant 1" (292 mm) 111" Sellante (26 mm) (25 mm) Enduit d'etanch6ite � d �i 1 L 12" Nail (305 mm) Claw 6 5/8" . 7 518" Clouer (168 -194 mm) 12" (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, mi inimum 3/8-inch head diameter, per shingle and beads of S.onneborn NP1 Gun Grade Polyurethane Sealanti or Henkel PL Roofing and Flashing Sealant. 11 Sealant 1: (�29'2rnra 1� SQ!!8nty (25 tsm) (25 rnrinduitd'EGsreehta Nail ., �5 (aern) a'�aLcr 9� Inm� Ll v35 rn a) 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, I.I.C. Certificate ofAuthorlration #9503 i C" EDITION {2017) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Evaluation Report 01506.01.08-R22 FL10124-R20 Revision 22: 09/20/2017 Page 5 of 6 7. 8. 9. 10. r, QOTRINI-P(IERD LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. QUALITY ASSURANCE ENTITY: U L LLC — QUA9625; (847) 664-3281 Exterior Research and Design, U.C. Certificate of Authorization #9503 END OF EVALUATION REPORT - CH EDITION (2017) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Evaluation Report 01506.01.08-R22 FL10124-R20 Revision 22: 09/20/2017 Page 6 of 6