HomeMy WebLinkAboutGENERATOR CONCRETE PAD�I`\\ GENERATOR
=
C7
�r
PAD
THICKNESS ' /\
�H
ISOMETRIC VIEW
PAD DIMENSIONS:
CONCRETE GENERATOR
= I GENERATOR UNIT BY
o SEPARATE SUBMITTAL
3 (SEE SCHEDULE FOR
N MINIMUM WEIGHT
REQUIRED)
54"LENGTH
PLAN VIEW
CONCRETE PAD
ROAD MESH
MASTERFIBER 3"' MIN t" MIN
MAC100 T
GROUNDS �.:,..:/......./G..i
50..
54"
AME�RICAST GENERATOR CONCRETE PAD
GENERATOR TABLE:
SGANNEU
By
s? 6 Pip P.nl lfit�
(ON -GRADE APPLICATIONS ONLY)
ON
AT
•MADID IN AW VWuAI
FID TAX A'^""' LIC@138 kS99.200S0t63
"M pwa-toAve. pan NOegR ion
T.I. 7rzan-190 F= "2-/6 ww
Emdk rEa�tk.<es "reM1..�caEctal2..�ea_.
HVHZ OR NON-HVHZ
RISK
EXPOSURE (EXP)
RISK
EXPOSURE (EXP)
RISK
EXPOSURE (EXP)
I
C
D
II
C
D.
III, IV
C
D.
E
150 MPH
30.44 Psf
36.94 Psf
170 MPH
39.09 Psf
47.44 Psf
.180 MPH
43.83,Psf
53.19 Psf
156 MPH
32.92 Psf
39.95 Psf
170 MPH
39.09 Psf
47.44 Psf
180 MPH
43.83 Psf
53.19 Psf
165 MPH
36.83 Psf
144.69 Psf
175 MPH
41.43 Psf
50.28 Psf
186 MPH
46.80 Psf
56.80 Psf
BRAND &MODEL
CAPACITY
WIDTH
`LENGTH
HEIGHT,
.WEIGHT
ALLOWABLE
PRESSURE
COMMENTS
Generac 005871 & 005883
10 KW
25.00
48 00
29.00
387 Ibs
41.43 Psf
EXP C 175 MPH & D 156 MPH
Generac 005872 & 005884
14 KW
25.00 " .
; 48.00",
'29.00",
439 Ibs.
47.44 Psf
EXP C 186 MPH & D 156 MPH
Generac 6459, 6461, 6462
16 KW
25.00 "
48.00"'.
. 29.00 "
513 lbs
47.44 Psf
Generac 006721
16 KW
25.00 "
48.00 "
29.00 "
.448 lbs
47.44 Psf
Generac 005873 & 005885
17 KW
25.00 "
48.00 ".
29.00 "
455, lbs
47.44 Psf
Generac 005874 & 005886
17 KW
25.00 "
48.00 ":
29.00 "
421 lbs
47.44 Psf
Generac 005875 & 005887
20 KW
25.00 "
48.00'
29.00 "
451 lbs-
47.44 Psf
Generac 006729 & 006730
20 KW
25.00"
-48.06 "
29.00 "
516 Ibs=
47.44 Psf
Generac 006551 & 006552
22 KW
25.00 "
48.00 "
29.00 "
526 lbs
47.44 Psf
Kohler 14RES & 20RES
14-20 KW
26.00 "
48.00 "
29.00 "
500 lbs
47.44 Psf
GE 40323GE & 40324GE
13 KW
35.00 "
39.40 "
39.00 "
540 lbs
39.09 Psf
EXP C 170 MPH & D 156 MPH
GE 04038215KW
15 KW
33.00 "
48.00 "
30.50 "
484 lbs
43.83 Psf
EXP C 180 MPH & D 156 MPH
-- --
GE 04037817KW
17 KW
33.00 "
48.00 "
30.50 "
484 lbs
43.83 Psf
GE 40330GE.& 40331GE
20 KW-
33.00 "--
-48.00=
-30.50=
-600-lbs-
-43.83 Psf-
Briggs & Stratton 040243-0
10 KW
31.00 "
32.00 "
34.00 "
430 lbs
43.83 Psf
Briggs & Stratton 040302-2
12 KW
33.75 "
50.00 "
31.60 "
507 lbs
41.43 Psf
EXP C 175 MPH & D 156 MPH
Briggs & Stratton 040303-1
15 KW
33.75 "
49.00 "
31.60 "
562 lbs
43.83 Psf
EXP C 180 MPH & D 156 MPH
Briggs & Stratton 040304-1
18 KW
33.75 "
49.00 "
31.60 "
568 lbs
44.00 Psf
Briggs & Stratton 040305-1
20 KW
33.75 "
49.00 "
31.60 "
570 lbs
44.00 Psf
Generac 7035, 7036, 7037
1 16 KW
25.00 "
48.00 "
29.00 "
406 lbs
47.44 Psf
EXP C 186 MPH & D 156 MPH
Generac 007038 & 007039
20 KW
25.00 "
48.00 "
29.00 "
448 lbs
47.44 Psf
Generac 007042 & 7043
22 KW
25.00 "
48.00 "
1 29.00 "
1 466 lbs
1 47.44 Psf
GENERATOR MOUNTING CONFIGURATION:
GENERATOR
GENERATOR ATTACHMENT BASE
OR SIMPSON A24 ANGLE BRACE
W/ (4) *10 SS 316 SELF-DRILLING
n SCREWS,
F-T I TO GENERATOR
F- I I = GENERATOR
(SEE CONCRETE PAD
SCHEDULE FOR
Ul DIMENSIONS & WEIGHT
_ = REQUIRED)
4"
�32" WIDTH --} �-54" LENGTH
0I
o SIDE VIEW FRONT VIEW
0
0
(SEE GENERATOR SPE
%" THICK GALVANIZED
WASHER& RUBBER
VIBRATION PAD
WIND DESIGN REOUIREMENTS-
(BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017))
AT -GRADE SIGN METHOD
ULTIMATE DESIGN WIND SPEED Vult = 186 mph
NOMINAL DESIGN WIND SPEED Vasd = 144 mph
RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A
EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85
ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND
GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2
FORCE COEFFICIENT Cf = 1.44
WIND PRESSURE:
P = qh G Cf = 56.80 Ib/ft2 (ASD)
GENERAL NOTES
40
2.
3.
ANCHOR TO PAD SCHEDULE: 4,
SUBSTRATE
DESCRIPTION
CONCRETE:
(2)-3/8"0 TITEN HD
(6000 PSI
ORE QUIVALENT,
MIN.)
2-3/4" FULL EMBED
0 CONCRETE, 3" MIN
EDGE DISTANCE, 6"
MIN. SPACING TO ANY
ADJACENT ANCHOR.
NOTES:
1. ANCHOR QUANTITY PER LONG SIDE
2. EMBEDMENT AND EDGE DISTANCE
EXCLUDES FINISHES, IF
APPLICABLE;,
3. ENSURE -MINIMUM -EDGE DISTANCE
AS NOTED IN ANCHOR SCHEDULE.
4. ENSURE'MINIMUMSPACING TO
ANY,ADJACENT, ANCHORS.
5: FOLLOW`MANUFACTURER'S
INSTALLATION'INSTRUCTIONS TO
INSTALL ANCHORS:
GENERATOR -
ATTACHMENT BASE,.
VARIES WITH MODEL
SEE GENERATOR SPECS
%- SIMPSON TITEN HD,
SEE ANCHOR SCHEDULE
2"x3"x3/a" GALV. STEEL -
WASHER
RUBBER VIBRATION PAD -
CONCRETE PAD -
6,000 PSI
LIGHTWEIGHT /
CONCRETE PAD .. CONCRETE MIX \
6,000 PSI `
LIGHTWEIGHT MASTERFIBER MAC 100
CONCRETE MIX & ROAD MESH
NOTES: FOAM CORE
1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2".
2. X DISTANCE 3" FROM UNIT EDGE TO CLIP.
3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN
ANCHOR REQUIREMENTS
5.
6.
7.
8.
9.
10.
11.
12.
13.
THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED
IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA
BUILDING CODE SIXTH EDITION (2017).
REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR
USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER
SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN
ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC
LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH
THE APPLICABLE BUILDING CODE --SHALL BE LESS THAN OR
EQUAL TO THE DESIGN PRESSURE "ASD"-•CAPACITY VALUES
LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN;
DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO
SPECIFICATIONS STATED. HEREIN':
UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES
HAVING EQUAL CLEARANCE. A'MINIMUM DISTANCE FROM UNIT
TO PAD EDGE IS SPECIFIED.
CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE _125 PCF
THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE
ALL VEGETATION, STUMPS, ROOTS; AND, FOREIGN MATERIALS
REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS
VERIFIED BY OTHERS.
RESISTANCE TO SLIDING OFTHE PAD ON.THE GROUND IS'NOT
PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD
PLACEMENT VARIES. 1 1. -
ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED &
INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS
(CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER
MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS
RESPONSIBILITY OF THE CONTRACTOR.
ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL
DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY
CONTRACTOR, -et. -al. -INDEMNIFIES & SAVES HARMLESS THIS
ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES
& APPELLATE FEES RESULTING FROM MATERIAL FABRICATION,
SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT
WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES &
FROM DEVIATIONS OF THIS PLAN.
WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL
RESPONSIBILITY OF THE INSTALLING CONTRACTOR.
CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED
WATERPROOFING MEMBRANE IS RESTORED AFTER
FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED
HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY
WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS
WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF
THE INSTALLING CONTRACTOR.
THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF
SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD.
CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL
BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING
SURFACES TO THIS DESIGN WHICH, SHALL BE. COORDINATED
BY THE PERMITTING CONTRACTOR::
THIS DOCUMENT IS _GENERIC AND'`DOES NOT:PERTAINTO ANY
SPECIFIC PROJECT'SITE. INFORMATION CONTAINED, HEREIN IS
BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS.
ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR
LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA
OR MEASUREMENTS DIMENSIONS ARE SHOWN TO ILLUSTRATE
DESIGN FORCES AND: OTHER DESIGN.CRIIERIA. THEY MAY
VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS
SPECIFIED HEREIN. WORK SHALLBE FIELD VERIFIED BY
OTHERS PRIORTO CONSTRUCTION. ENGINEERING EXPRESS
SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO
REEVALUATE OUR WORK UPON DISCOVERY OF ANY
INACCURATE INFORMATION PRIOR TO MODIFICATION OF
EXISTING FIELD CONDITIONS AND FABRICATION AND
INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS
TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE
OUR CERTIFICATION.
EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL
CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.
L. BENNARDO, P.E.
0
QB:IXED, CMTHMNG P.E. APPUA BELOW
NK L. BENNARDO, P.E.
"HERE IS A DIGITAL
.NATURE ON SHEET 1, THIS
:ET IS PART OF A DIGITALLY
INED FILE, SHALL REMAIN IN
IITAL FORMAT, & PRINTED
PIES OF THIS DOCUMENT
E NOT CONSIDERED SIGNET
D SEALED. IF THERE IS NO
IITAL SIGNATURE ON SHEET 1
THIS SHEET DOES NOT
VTAIN AN ENGINEER'S
'GINAL SIGNATURE & SEAL.
U 0 N
Z Od
� f
�® WMr OU,i
ul v
Wjn LU M o .0 y Ln
V, w(n , xw#
Z� o azo.
g¢ w W.LL'J -,
'1t a= F-
WW ONO wwv
w
U i W ?
N LL M 2 U,
N W 2 W
O W Lu
� 0
w
y Cn �z
V LL
2
c�
000
o ��aHzo
a�z�a
wM
�¢kokw�
~ GLo=
0 0 �mz�o
Y w o H.16
c
yam oC_
LonEd m- V, O 0
�s
COPYRIGHT ENGINEERING EXPRESS
17-3961.1
SCALE: NTS UNLESS NOTED
OFq
u