HomeMy WebLinkAboutEQUIVALENCY EVALUATION REPORTSCANNED }
EquivaC'Nb"y-1rvW11Pdtion Report
Rule 61G20-3 F.A.C. I Report No. 2000-EER, Rev. 2 ) Project No. 418-0102 1 3/2/18 1 Page 1 of 1
Product Manufacturer
Maxim Industries, Inc.
1630 Terre Colony Court
Dallas, TX 7,5212 ,
Product Name, Model and/or Description
Series "DCM" Dade Curb Mount Skylight
Series "DSF" Dade Self -Flashing Skylight
Code: Current Edition of the Florida Building Code including the 611 Edition (2017) Florida Building Code
Compliance Method: Product Approval Rule 61G20-3.015(4)(d) — Equivalency of Standards
Product Testing:
REC VIE ED
APR 16 2018
ST. Lucie County, Permitting
• Architectural Testing Inc. Test Report No. 01-43381.01, dated 01/29/03, signed and sealed by Steve Urich, P.E., testing
to TAS 201-94, TAS 202-94 and TAS 203-94
Performance Test Standard Equivalency Evaluation:
It has been concluded that no revisions or changes to the referenced standards have occurred between the following (where
applicable) that affect the results of design, testing or engineering of the approved product(s).
• Chapter 35 of the 5t' Edition (2014) Florida Building Code compared to Chapter 35 of the 61h Edition (2017) Florida
Building Code
• Chapter 46 of the 5th Edition (2014) Florida Residential Code compared to Chapter 46 of the 6th Edition (2017) Florida
Residential Code
I
• Test Protocols for HVHZ/5th Edition (2014) Florida Building Code compared to Test Protocols for HVHZ/6th Edition
(2017) Florida Building Code, specifically the following where' applicable.
o TAS 201-94, TAS 202-94 and TAS 203-94
Conformance Review of skylight glazing material Manufacturer and Component Approval per Miami -Dade NOA:
i
• The currently issued Miami -Dade NOA for component approval to the Florida Building Code for Covestro, LLC
Makrolon Polycarbonate Sheets was reviewed and found to be in compliance with the Florida Building Code including
the 6th Edition (2017) Florida Building Code. Covestro, LLC Miami -Dade NOAs and can be found here.
I
Therefore, all test standards used in testing and all design standards used in design and engineering of the currently approved
product(s) remain valid for compliance to the Current Edition of the Florida Building Code.
i
_.,.,�,�...._ D• •t II d
Certificate of Independence per Product Approval
Rule 61G20-3.009
PTC Product Design Group, LLC and Robert J. Amoruso, P.E.
does not have, nor will acquire, any financial interest in the
company manufacturing or distributing product(s) covered
by this Product Evaluation Report.
PTC Product Design Group, LLC and Robert J. Amoruso, P.E.
do not have, nor will acquire any financial interest in any ;
other entity involved in the approval processor testing of
the product(s) covered by this Product Evaluation Report.
PTC Product Design Group, LLC
i/ L 321-690-1788 1
I
I
ig) a y signe
by Robert J
;Amoruso
Date•
�Y'•ri yY?es5�x'.Y7'�,p�
201 &0105
10:09:28-05'00'
Evaluated by:
Robert J. Amoruso, P.E.
FL P.E. License No. 49752
PO Box 520775 1 Longwood, FL 32752-0775
FBPE Certification of Authorization No. 25935
MIAMI•DADE
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA) RECEIVED
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
4nL) 315-2590 F (786) 315-2599
Covestro, LLC APR 16 2018
119 Salisbury Road
Sheffield, MA 01257 S-r. wcie county, Permitting
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If, this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Makrolon Polycarbonate Sheets
APPROVAL DOCUMENT: Drawing No. G08-01, titled "Polycarbonate Sheets", sheet 1 of 1, dated
09/12/2008, with revision G dated 02/26/2018, prepared by Al-Farooq Corporation, signed and sealed by
Javad Ahmad, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of
Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: None
LABELING: Each sheet shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #17-0410.01 and consists of this page 1 and evidence pages E-1 and E-2, as well as
approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
CEzMLDADECOUNTYNOA No. 17-1219.02
•. Expiration Date: August 27, 2022
Approval Date: March 22, 2018
031i9 ���5 Page 1
Covestro. LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. Evidence submitted under previous NOA's
A. DRAWINGS "Submitted under NOA # 1 fi-1024.01 "
1. Drawing No. G08-01, titled "Polycarbonate Sheets", sheet 1 of 1, dated 09/12/2008, with
revision E dated 12/28/2016, prepared by Al-Farooq Corporation, signed and sealed by Javad
Ahmad, P.E.
B.
TESTS "Submitted under NOA # 16-1024.01 "
Report No.
Test
Date
Seal & Signature
1.
RJ3724-1
ASTM D1929-13a
12/31/14
Christopher Bowness, P.E.
2.
TJ2554-2
ASTM D635-10
12/24/14
Christopher Bowness, P.E.
3.
TJ2554-6
ASTM D2843-10
12/24/14
Christopher Bowness, P.E.
"Submitted under NOA # 12-0605.05"
4.
B2577.01-106.31
ASTM D1929/2843
04/27/12
G. T. Hartman, P.E.
ASTM D635/638/2565
"Submitted under NOA # 08-0926.15"
5.
72305.01-106-18
ASTM D1929/2843
08/06/08
Joseph A. Reed, P.E.
ASTM D635/638
ASTM G155
6.
72305.02-106-18
ASTM D1929/2843/635
08/19/08
Joseph A. Reed, P.E.
7.
72305.03-106-18
ASTM D1929/2843/635
08/21/08
Joseph A. Reed, P.E.
8.
72305.04-106-18
ASTM D1929/2843/635
08/21/08
Joseph A. Reed, P.E.
9.
72305.05-106-18
ASTM D1929/2843/635
08/22/08
Joseph A. Reed, P.E.
10.
72305.06-106-18
ASTM D1929/2843/635
08/26/08
Joseph A. Reed, P.E.
11.
72305.07-106-18
ASTM D1929/2843/635
08/26/08
Joseph A. Reed, P.E.
12.
72305.08-106-18
ASTM D1929/2843/635
08/26/08
Joseph A. Reed, P.E.
C.
CALCULATIONS
1.
None.
D.
QUALITY ASSURANCE
1.
Miami -Dade Department of Regulatory and Economic Resources (RER)
E.
MATERIAL CERTIFICATIONS
1.
None.
*e,133otS
Ca los M. Utrera, P.E.
Product Control Examiner
NOA No.17-1219.02
Expiration Date: August 27, 2022
Approval Date: March 22, 2018
E-1
Covestro. LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1. Statement letter of code conformance to the 51 edition (2014) FBC and of no financial interest
issued by Al-Farooq Corporation, dated 03/28/2017, signed and sealed by Javad Ahmad, P.E.
"Submitted under NOA # 15-1014.01 "
2. Certificate of Amendment of Certificate of Organization dated 09/22/2015.
"Submitted under NOA # 12-0605.05"
3. Statement letter of code conformance to 2010 FBC and no financial interest issued by Al-
Farooq Corporation, dated 05/18/2012, signed and sealed by Javad Ahmad, P.E.
"Submitted under NOA # 08-0926.15"
4. Certificate of merger of Sheffield Plastics Inc, and Bayer MaterialScience LLC, dated
03/31/2009.
2. New evidence submitted
A. DRAWINGS
1. Drawing No. G08-01, titled "Polycarbonate Sheets", sheet 1 of 1, dated 09/12/2008, with
revision G dated 02/26/2018, prepared by Al-Farooq Corporation, signed and sealed by Javad
Ahmad, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 6th edition (2017) FBC and of no financial interest
issued by Al-Farooq Corporation, dated 12/01/2017, signed and sealed by Javad Ahmad, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No.17-1219.02
Expiration Date: August 27, 2022
Approval Date: March 22, 2018
E-2
PRODUCT PROPERTIES
TEST DESCRIPTION
TEST
METHOD
TEST RESULTS
MAKROLONO POLYCARBONATE SHEET
GP
1/32'
THICKNESS
GP
/16" TO .118
THICKNESS
GP
SK
.118" TO 1/2"
THICKNESS 4f
SL
UV
1/8' TO 1/2'
THICKNESS
AR
1/8' To 1/2'
THICKNESS
MAK15
EX
1/8" TO 1/2'
THICKNESS
SKI
'118' To 1/2'
THICKNESS
SELF IGNITION TEMP.
ASTM D1929
102ZF
1040'F
1040'F
102ZF
10407
10587
1030'F
FLASH IGNITION TEMP.
ASTM 01929
824'F
824'F
824T
824'F
806'F
84ZF
824'F
SMOKE DENSITY RATING (MAX.)
ASTM 2843
43.7%
69.4%
69.4%
57.7%
50.9%
51.5%
61.3%
AVERAGE RATE OF BURNING
ASTM D635
--
--
--
--
--
--
--
BURNING RATE CLASS
ASTM 0635
CC2
CCI
CCI
CC7
i CC7
CCl I
CCI
* * MATERIAL THICKNESS AT PEAK OF SMOOTH OR PRISMATIC SURFACE
TENSILE PROPERTIES
TEST RESULTS
MAKROLONO POLYCARBONATE SHEET
GP
TEST
1/16' TO 1/2'
TEST DESCRIPTION
METHOD
THICKNESS
TENSILE STRENGTH MFAN
ASTM D638
6986 PSI
9071 PSI
* 1 6LVUKL I Atli
* WEATHERING AS PER THE FLORIDA BLDG. CODE.
PRODUCT PROPERTIES
TEST DESCRIPTION
TEST
METHOD
TEST RESULTS
MAKROLON HYGARDO SHEET
CG3"I5
.90' OVERALL
THICKNESS
CG 500
EX 500
.530" OVERALL
THICKNESS
CG 750
780" OVERALL
THICKNESS
BR 1000
EX 1000
1.05' OVERALL
THICKNESS
BR 1250
EX 1250
1.30' OVERALL
THICKNESS
BE, 750
.775" OVERALL
THICKNESS
MS 1250
EX 1300
1.30' OVERALL
THICKNESS
SELF IGNITION TEMP.
ASTM D1929
91TF
8967
896'F
8787
89157
FLASH IGNITION TEMP.
ASTM D1929
734T
806'F
82WF
6807
69WF
SMOKE DENSRY RATING (MAX.)
ASTM 2843
69.6%
50.6%
45%
50.6%
45.3%
AVERAGE RATE OF BURNING
ASTM D635 1
.405 IN./MIN.
.370 IN./MIN.
BURNING RATE CLASS
ASTM D635
CC1
CCI
CC1
CC2
CC2
MAKROLON HYGARDO CG 375
3/16" MAKROLON AR-1 POLYCARBONATE SHEET
.025" POLYURETHANE INTERLAYER
3/16" MAKROLON AR-1 POLYCARBONATE SHEET
MAKROLON HYGARDO CG 590
MAKROLON HYGARD ® EX 500
1/8" MAKROLON AR-1 POLYCARBONATE SHEET
.025' POLYURETHANE INTERLAYER
1/4" MAKROLON POLYCARBONATE SHEET
.025" POLYURETHANE INTERLAYER
1/8' MAKROLON AR-1 POLYCARBONATE SHEET
) AKROLON HYGARD ® CG 750
1/8' MAKROLON AR-1 POLYCARBONATE SHEET
.025" POLYURETHANE INTERLAYER
1/2- MAKROLON POLYCARBONATE SHEET
.025' POLYURETHANE INTERLAYER
1/8' MAKROLON AR-1 POLYCARBONATE SHEET
J
1/8' MAKROLON AR-1 POLYCARBONATE SHEET
.025' POLYURETHANE INTERLAYER
3/8" MAKROLON POLYCARSONATE SHEET
.025" POLYURETHANE INTERLAYER
3/8" MAKROLON POLYCARBONATE SHEET
.025" POLYURETHANE INTERLAYER
1/8" MAKROLON AR-1 POLYCARBONATE SHEET
MAKROLON HYGARDO HR 1250
MAIMOLON HYGARDO EX 1250
1/8' MAKROLON AR-
i POLYCAR13ONATE SHEET
.025' POLYURETHANE INTERLAYER
1/2' MAKROLON POLYCARBONATE SHEET
.025" POLYURETHANE INTERLAYER
1/2- MAKROLON POLYCARBONATE SHEET
.025" POLYURETHANE INTERLAYER
1/8" MAKROLON AR-1 POLYCARBONATE SHEET
ROLON HYGARDO BR 1750
1/8" MAKROLON AR-1 POLYCARBONATE SHEET
025" POLYURETHANE INTERLAYER
I/2" ACRYUC SHEET
025" POLYURETHANE INTERLAYER
1/8" MAKROLON AR-1 POLYCARBONATE SHEET
MAKROLON HYGARDO MS 1250
MAKROLON HYGARDO EX'1300
1/8" MAKROLON AR-1 POLYCAEiBONATE SHEET
,025" POLYURETHANE INTERLAYER
1/2" MAKROLON OP SHEET
.025" POLYURETHANE INTERLAYER
1/2' ACRYUC SHEET
,025" POLYURETHANE INTERLAYER
1/8" MAKROLON AR-1 POLYCARBONATE SHEET
GP— GENERAL PURPOSE
SL— SIGN GRADE ENHANCED UV PROTECTION
UV —HIGH OPTICAL QUALITY ENHANCED W PROTECTION
AR —ABRASION AND UV RESISTANT
MAK15— ABRASION AND LONG TERM UV RESISTANT
EX— BLAST RESISTANT
SK1— SKYLIGHT SMOOTH OR PRISMATIC FINISH
SK— SKYLIGHT SMOOTH OR PRISMATIC FINISH
POLYCARBONATE SHEETS CAN BE CLEAR OR COLORED
WITH POLISHED, MATTE OR TEXTURED SURFACES.
PRODUCT DESCRIPTION:
POLYCARBONATE SHEETS ARE EXTRUDED FROM POLYCARBONATE
RESINS WITH PRIMARY USE AS GLAZING FOR WINDOWS, SKYLIGHTS
AND LIGHT TRANSMITTING SYSTEMS.
STANDARD SIZES ARE UPTO 120" LONG AND 96' WIDE.
CUSTOM SIZES ARE ALSO AVAILABLE.
MAKROLON POLYCARSONATE MATERIAL COMPLIES WITH THE REQUIREMENTS
OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH
VELOCITY HURRICANE ZONE (WHZ).
MAKROLON GP REPRESENTS THE UNCOATED POLYCARBONATE SHEET
AND IS APPROVED FOR USE IN EXTERIOR APPLICATIONS WITHOUT
THE W PROTECTIVE COATING.
MAKROLON GP ALSO INCLUDES:
OP, GP MATTE, GP PEBBLE, GP PRISMATIC AND GP SATIN.
ACCELERATED WEATHERING*TESTING CONDUCTED PER ASTM D638 ON
MAKROLON GP WITHOUT W PROTECTIVE COATING.
SHALL QUALIFY THE FOLLOWING:
MAKROLON SL
MAKROLON W
MAKROLON AR
MAKROLON MAK15
MAKROLON EX
MAKROLON SKI
MAKROLON SK
NOTE:
THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN
EVALUATION OF STRUCTURAL PERFORMANCE OF THIS COMPONENT.
SYSTEMS INCORPORATING THESE COMPONENTS SHALL APPLY FOR
A NOA TO THE MLAMI-DARE COUNTY PRODUCT CONTROL DIVISION
AND SHALL SUBMIT TEST REPORTS AND OTHER REQUIRED DOCUMENTS
SHOWING THAT THE SYSTEM USING THESE COMPONENTS WILL RESIST
THE LOADS ACCORDING TO CHAPTER 16 OF THE FLORIDA BLDG. CODE.
PRODUCT REVISED FEB 2 9 2018
es eompteng with the Florida
Bulldin8 Code
.-No. 17-1219.02
Exphatlon D to 08/27/2022
By
Miam d P uet Control
Z
O Gr'n�
O 'a
G IL
JJo
LL w y LL N
zo
y Om
QuZlm2�
n
w
m
N
W
= c
to
n
Q t N
Z 0 wo
o
m
Om�
J �Ufpn
D. W Qwn^
U N
i
OF 4ll�� drawing no.
G08-01