Loading...
HomeMy WebLinkAboutEQUIVALENCY EVALUATION REPORTSCANNED } EquivaC'Nb"y-1rvW11Pdtion Report Rule 61G20-3 F.A.C. I Report No. 2000-EER, Rev. 2 ) Project No. 418-0102 1 3/2/18 1 Page 1 of 1 Product Manufacturer Maxim Industries, Inc. 1630 Terre Colony Court Dallas, TX 7,5212 , Product Name, Model and/or Description Series "DCM" Dade Curb Mount Skylight Series "DSF" Dade Self -Flashing Skylight Code: Current Edition of the Florida Building Code including the 611 Edition (2017) Florida Building Code Compliance Method: Product Approval Rule 61G20-3.015(4)(d) — Equivalency of Standards Product Testing: REC VIE ED APR 16 2018 ST. Lucie County, Permitting • Architectural Testing Inc. Test Report No. 01-43381.01, dated 01/29/03, signed and sealed by Steve Urich, P.E., testing to TAS 201-94, TAS 202-94 and TAS 203-94 Performance Test Standard Equivalency Evaluation: It has been concluded that no revisions or changes to the referenced standards have occurred between the following (where applicable) that affect the results of design, testing or engineering of the approved product(s). • Chapter 35 of the 5t' Edition (2014) Florida Building Code compared to Chapter 35 of the 61h Edition (2017) Florida Building Code • Chapter 46 of the 5th Edition (2014) Florida Residential Code compared to Chapter 46 of the 6th Edition (2017) Florida Residential Code I • Test Protocols for HVHZ/5th Edition (2014) Florida Building Code compared to Test Protocols for HVHZ/6th Edition (2017) Florida Building Code, specifically the following where' applicable. o TAS 201-94, TAS 202-94 and TAS 203-94 Conformance Review of skylight glazing material Manufacturer and Component Approval per Miami -Dade NOA: i • The currently issued Miami -Dade NOA for component approval to the Florida Building Code for Covestro, LLC Makrolon Polycarbonate Sheets was reviewed and found to be in compliance with the Florida Building Code including the 6th Edition (2017) Florida Building Code. Covestro, LLC Miami -Dade NOAs and can be found here. I Therefore, all test standards used in testing and all design standards used in design and engineering of the currently approved product(s) remain valid for compliance to the Current Edition of the Florida Building Code. i _.,.,�,�...._ D• •t II d Certificate of Independence per Product Approval Rule 61G20-3.009 PTC Product Design Group, LLC and Robert J. Amoruso, P.E. does not have, nor will acquire, any financial interest in the company manufacturing or distributing product(s) covered by this Product Evaluation Report. PTC Product Design Group, LLC and Robert J. Amoruso, P.E. do not have, nor will acquire any financial interest in any ; other entity involved in the approval processor testing of the product(s) covered by this Product Evaluation Report. PTC Product Design Group, LLC i/ L 321-690-1788 1 I I ig) a y signe by Robert J ;Amoruso Date• �Y'•ri yY?es5�x'.Y7'�,p� 201 &0105 10:09:28-05'00' Evaluated by: Robert J. Amoruso, P.E. FL P.E. License No. 49752 PO Box 520775 1 Longwood, FL 32752-0775 FBPE Certification of Authorization No. 25935 MIAMI•DADE DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) RECEIVED MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 4nL) 315-2590 F (786) 315-2599 Covestro, LLC APR 16 2018 119 Salisbury Road Sheffield, MA 01257 S-r. wcie county, Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If, this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Makrolon Polycarbonate Sheets APPROVAL DOCUMENT: Drawing No. G08-01, titled "Polycarbonate Sheets", sheet 1 of 1, dated 09/12/2008, with revision G dated 02/26/2018, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None LABELING: Each sheet shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #17-0410.01 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. CEzMLDADECOUNTYNOA No. 17-1219.02 •. Expiration Date: August 27, 2022 Approval Date: March 22, 2018 031i9 ���5 Page 1 Covestro. LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted under previous NOA's A. DRAWINGS "Submitted under NOA # 1 fi-1024.01 " 1. Drawing No. G08-01, titled "Polycarbonate Sheets", sheet 1 of 1, dated 09/12/2008, with revision E dated 12/28/2016, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted under NOA # 16-1024.01 " Report No. Test Date Seal & Signature 1. RJ3724-1 ASTM D1929-13a 12/31/14 Christopher Bowness, P.E. 2. TJ2554-2 ASTM D635-10 12/24/14 Christopher Bowness, P.E. 3. TJ2554-6 ASTM D2843-10 12/24/14 Christopher Bowness, P.E. "Submitted under NOA # 12-0605.05" 4. B2577.01-106.31 ASTM D1929/2843 04/27/12 G. T. Hartman, P.E. ASTM D635/638/2565 "Submitted under NOA # 08-0926.15" 5. 72305.01-106-18 ASTM D1929/2843 08/06/08 Joseph A. Reed, P.E. ASTM D635/638 ASTM G155 6. 72305.02-106-18 ASTM D1929/2843/635 08/19/08 Joseph A. Reed, P.E. 7. 72305.03-106-18 ASTM D1929/2843/635 08/21/08 Joseph A. Reed, P.E. 8. 72305.04-106-18 ASTM D1929/2843/635 08/21/08 Joseph A. Reed, P.E. 9. 72305.05-106-18 ASTM D1929/2843/635 08/22/08 Joseph A. Reed, P.E. 10. 72305.06-106-18 ASTM D1929/2843/635 08/26/08 Joseph A. Reed, P.E. 11. 72305.07-106-18 ASTM D1929/2843/635 08/26/08 Joseph A. Reed, P.E. 12. 72305.08-106-18 ASTM D1929/2843/635 08/26/08 Joseph A. Reed, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. *e,133otS Ca los M. Utrera, P.E. Product Control Examiner NOA No.17-1219.02 Expiration Date: August 27, 2022 Approval Date: March 22, 2018 E-1 Covestro. LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of code conformance to the 51 edition (2014) FBC and of no financial interest issued by Al-Farooq Corporation, dated 03/28/2017, signed and sealed by Javad Ahmad, P.E. "Submitted under NOA # 15-1014.01 " 2. Certificate of Amendment of Certificate of Organization dated 09/22/2015. "Submitted under NOA # 12-0605.05" 3. Statement letter of code conformance to 2010 FBC and no financial interest issued by Al- Farooq Corporation, dated 05/18/2012, signed and sealed by Javad Ahmad, P.E. "Submitted under NOA # 08-0926.15" 4. Certificate of merger of Sheffield Plastics Inc, and Bayer MaterialScience LLC, dated 03/31/2009. 2. New evidence submitted A. DRAWINGS 1. Drawing No. G08-01, titled "Polycarbonate Sheets", sheet 1 of 1, dated 09/12/2008, with revision G dated 02/26/2018, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 6th edition (2017) FBC and of no financial interest issued by Al-Farooq Corporation, dated 12/01/2017, signed and sealed by Javad Ahmad, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No.17-1219.02 Expiration Date: August 27, 2022 Approval Date: March 22, 2018 E-2 PRODUCT PROPERTIES TEST DESCRIPTION TEST METHOD TEST RESULTS MAKROLONO POLYCARBONATE SHEET GP 1/32' THICKNESS GP /16" TO .118 THICKNESS GP SK .118" TO 1/2" THICKNESS 4f SL UV 1/8' TO 1/2' THICKNESS AR 1/8' To 1/2' THICKNESS MAK15 EX 1/8" TO 1/2' THICKNESS SKI '118' To 1/2' THICKNESS SELF IGNITION TEMP. ASTM D1929 102ZF 1040'F 1040'F 102ZF 10407 10587 1030'F FLASH IGNITION TEMP. ASTM 01929 824'F 824'F 824T 824'F 806'F 84ZF 824'F SMOKE DENSITY RATING (MAX.) ASTM 2843 43.7% 69.4% 69.4% 57.7% 50.9% 51.5% 61.3% AVERAGE RATE OF BURNING ASTM D635 -- -- -- -- -- -- -- BURNING RATE CLASS ASTM 0635 CC2 CCI CCI CC7 i CC7 CCl I CCI * * MATERIAL THICKNESS AT PEAK OF SMOOTH OR PRISMATIC SURFACE TENSILE PROPERTIES TEST RESULTS MAKROLONO POLYCARBONATE SHEET GP TEST 1/16' TO 1/2' TEST DESCRIPTION METHOD THICKNESS TENSILE STRENGTH MFAN ASTM D638 6986 PSI 9071 PSI * 1 6LVUKL I Atli * WEATHERING AS PER THE FLORIDA BLDG. CODE. PRODUCT PROPERTIES TEST DESCRIPTION TEST METHOD TEST RESULTS MAKROLON HYGARDO SHEET CG3"I5 .90' OVERALL THICKNESS CG 500 EX 500 .530" OVERALL THICKNESS CG 750 780" OVERALL THICKNESS BR 1000 EX 1000 1.05' OVERALL THICKNESS BR 1250 EX 1250 1.30' OVERALL THICKNESS BE, 750 .775" OVERALL THICKNESS MS 1250 EX 1300 1.30' OVERALL THICKNESS SELF IGNITION TEMP. ASTM D1929 91TF 8967 896'F 8787 89157 FLASH IGNITION TEMP. ASTM D1929 734T 806'F 82WF 6807 69WF SMOKE DENSRY RATING (MAX.) ASTM 2843 69.6% 50.6% 45% 50.6% 45.3% AVERAGE RATE OF BURNING ASTM D635 1 .405 IN./MIN. .370 IN./MIN. BURNING RATE CLASS ASTM D635 CC1 CCI CC1 CC2 CC2 MAKROLON HYGARDO CG 375 3/16" MAKROLON AR-1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 3/16" MAKROLON AR-1 POLYCARBONATE SHEET MAKROLON HYGARDO CG 590 MAKROLON HYGARD ® EX 500 1/8" MAKROLON AR-1 POLYCARBONATE SHEET .025' POLYURETHANE INTERLAYER 1/4" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/8' MAKROLON AR-1 POLYCARBONATE SHEET ) AKROLON HYGARD ® CG 750 1/8' MAKROLON AR-1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/2- MAKROLON POLYCARBONATE SHEET .025' POLYURETHANE INTERLAYER 1/8' MAKROLON AR-1 POLYCARBONATE SHEET J 1/8' MAKROLON AR-1 POLYCARBONATE SHEET .025' POLYURETHANE INTERLAYER 3/8" MAKROLON POLYCARSONATE SHEET .025" POLYURETHANE INTERLAYER 3/8" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR-1 POLYCARBONATE SHEET MAKROLON HYGARDO HR 1250 MAIMOLON HYGARDO EX 1250 1/8' MAKROLON AR- i POLYCAR13ONATE SHEET .025' POLYURETHANE INTERLAYER 1/2' MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/2- MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR-1 POLYCARBONATE SHEET ROLON HYGARDO BR 1750 1/8" MAKROLON AR-1 POLYCARBONATE SHEET 025" POLYURETHANE INTERLAYER I/2" ACRYUC SHEET 025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR-1 POLYCARBONATE SHEET MAKROLON HYGARDO MS 1250 MAKROLON HYGARDO EX'1300 1/8" MAKROLON AR-1 POLYCAEiBONATE SHEET ,025" POLYURETHANE INTERLAYER 1/2" MAKROLON OP SHEET .025" POLYURETHANE INTERLAYER 1/2' ACRYUC SHEET ,025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR-1 POLYCARBONATE SHEET GP— GENERAL PURPOSE SL— SIGN GRADE ENHANCED UV PROTECTION UV —HIGH OPTICAL QUALITY ENHANCED W PROTECTION AR —ABRASION AND UV RESISTANT MAK15— ABRASION AND LONG TERM UV RESISTANT EX— BLAST RESISTANT SK1— SKYLIGHT SMOOTH OR PRISMATIC FINISH SK— SKYLIGHT SMOOTH OR PRISMATIC FINISH POLYCARBONATE SHEETS CAN BE CLEAR OR COLORED WITH POLISHED, MATTE OR TEXTURED SURFACES. PRODUCT DESCRIPTION: POLYCARBONATE SHEETS ARE EXTRUDED FROM POLYCARBONATE RESINS WITH PRIMARY USE AS GLAZING FOR WINDOWS, SKYLIGHTS AND LIGHT TRANSMITTING SYSTEMS. STANDARD SIZES ARE UPTO 120" LONG AND 96' WIDE. CUSTOM SIZES ARE ALSO AVAILABLE. MAKROLON POLYCARSONATE MATERIAL COMPLIES WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (WHZ). MAKROLON GP REPRESENTS THE UNCOATED POLYCARBONATE SHEET AND IS APPROVED FOR USE IN EXTERIOR APPLICATIONS WITHOUT THE W PROTECTIVE COATING. MAKROLON GP ALSO INCLUDES: OP, GP MATTE, GP PEBBLE, GP PRISMATIC AND GP SATIN. ACCELERATED WEATHERING*TESTING CONDUCTED PER ASTM D638 ON MAKROLON GP WITHOUT W PROTECTIVE COATING. SHALL QUALIFY THE FOLLOWING: MAKROLON SL MAKROLON W MAKROLON AR MAKROLON MAK15 MAKROLON EX MAKROLON SKI MAKROLON SK NOTE: THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN EVALUATION OF STRUCTURAL PERFORMANCE OF THIS COMPONENT. SYSTEMS INCORPORATING THESE COMPONENTS SHALL APPLY FOR A NOA TO THE MLAMI-DARE COUNTY PRODUCT CONTROL DIVISION AND SHALL SUBMIT TEST REPORTS AND OTHER REQUIRED DOCUMENTS SHOWING THAT THE SYSTEM USING THESE COMPONENTS WILL RESIST THE LOADS ACCORDING TO CHAPTER 16 OF THE FLORIDA BLDG. CODE. PRODUCT REVISED FEB 2 9 2018 es eompteng with the Florida Bulldin8 Code .-No. 17-1219.02 Exphatlon D to 08/27/2022 By Miam d P uet Control Z O Gr'n� O 'a G IL JJo LL w y LL N zo y Om QuZlm2� n w m N W = c to n Q t N Z 0 wo o m Om� J �Ufpn D. W Qwn^ U N i OF 4ll�� drawing no. G08-01