Loading...
HomeMy WebLinkAboutEVALUATION REPORT16j EVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR 72202 (254) 913-7750 EXTERIOR RESEARCH & DESIGN, I.I.C. 11� Certificate of Authorization #9503 9 ��Py(:�6i� 353 CHRISTIAN STREET, UNIT #13 I OXFORD, CT 06478 (203) 262-9245 SCOPE: This Evaluation Report is issued under Rule 61Ge construction materials in the State of Florida. The P.E. for use of the product under the Florida Bi products described herein have been evaluated sections noted herein. DESCRIPTION: Tarco Roof Underlayments Evaluation Report 10880.07.08-119 FL10450-R9 Date of Issuance: 07/11/2008 Revision 9:10/03/2017 I and the applicable rules and regulations governing the use of :umentation submitted has been reviewed by Robert Nieminen, ing Code and Florida Building Code, Residential Volume. The compliance with the 6th Edition (2017) Florida Building Code LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE�7rtNECESSARY h7eIIN ORDER TO P E�O 03/20I7. ThIs do or S aes dh e� �� CODES. document. CERTIFICATION OF INDEPENDENCE: I 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. ' 2. Trinity J ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. y�i 1 �at""t+ � It �4 - 0 CONCEALED FASTENERS OR ATTACHMEN ARE THE RESPONSIBILITY OF THE EC ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE, REVIEW BY DATE I 'PLANS AND PERMIT MUST BE KEPT N JOB SITE OR NA INSPECT'ION(S)!WILL BE MADE CONTRACTOR OR R ORD FILE COPY T\\,,TR1N1TYJERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing I Sub -Category: Underlayment Compliance Statement: Tarco Roof Underlayments, as produced by Tarco Roofing, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to tile Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1504.3.1 1507.1.1, T1507.1.1 1507.1.1, T1507.1.1 1507.1.1, T1507.1.1, 1507.2.9.2 1507.2.9.2 1507.2.9.2, FRSA/TRI April 2012 1507.3.3 FRSA/TRI April 2012 REFERENCES: Enti ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) PRI (TST5878) PRI(TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) Miami -Dade (CER1592) Tarco Roofing UL, LLC. (QUA9625) Exterior Research and Design, I.I.C. Certificate of Authorization #9503 Property I Standard Year Wind Uplift FM 4474 2011 Physical P ioperties ASTM D226 2009 Physical Properties ASTM D4869 2016 Physical Properties ASTM D1970 2015 Physical Properties ASTM D3909 2012 Physical Properties ASTM D6380 2013 Physical Properties FRSA/TRI April 2012 (04-12) 2012 Physical Properties ASTM D6164 2011 I . Examination Reference Date FRSA/TRI April 2012 (04-12) T33190.08.10 08/06/2010 ASTM D1970 T32530.08.10 08/17/2010 ASTM D1970 T30160.08.09-R1 10/12/2010 FM 4474 T37610.07.11 06/29/2011 ASTM D3909 T40780.04.12 04/06/2012 ASTM D6380 T40790.04.12 04/06/2012 ASTIVIF164 T35410.04.12 04/18/2012 ASTM D1970 T45250.04.13-R2 04/23/2013 FRSA/TRI April 2012 (04-12) T43930.09.13-R2 09/11/2013 ASTM D226 & D4869 SC4950.02.14-R2 06/25/2014 ASTM D1970 TAR-SC9480.15 07/02/2015 FM 4474 TAR-SC8020.14 12/03/2015 FM 4474 TAR-SC5670.03.16 03/21/2016 FM 4474 T6460.06.07-R2 05/26/2017 ASTM D226 TAR-SC13965.02.17-R1 05/17/2017 FBJ 1507.1.1(Exception) TAR-SC16115.17 10/02/2017 FRSA/TRI April 2012 (04-12) TAR-SC16115.17 10/02/2017 ASTM D1970 BRY-018-02-01 08/11/2003 ASTM D1970 BRY-017-02-01 08/11/2003 ASTM D226 TOT-014-02-02 05/18/2004 ASTM D226 TOT-015-02-02 05/24/2004 ASTM D4869 TOT-009-02-01 09/14/2004 ASTM D4869 TOT-009-02-02 09/14/2004 ASTM D226 TOT-041-02-01 05/24/2006 FiBC HVHZ Certification 16-1116.09 01/12/2017 Adhesive compound Affidavit 12/15/2015 Quality Assurance Service Confirmation Exp. 06/28/2020 C" EDITION (2017) FBC NON-HVHZ EVALUATION Tarco Roof Underlayments; (254) 913-7750 i Evaluation Report 30880.07.08-R9 FL10450-R9 Revision 9:10/03/2017 Page 2 of 10 TRINITY I ERD II � 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlayments: LeakBarrier MS300 Ice and Water ArTor is a self -adhering, glass mat reinforced, mineral surfaced, SBS -modified roof underlayment; meets ASTM D1970. LeakBarrier P5200"' Ice and Water f rmor is a self -adhering, glass mat reinforced, fabric surfaced, SBS modified roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). LeakBarrier PS200mu Ice and Water Armor is a self -adhering, glass mat reinforced, smooth poly film surfaced, SBS modified roof underlayment; meets ASTM D1970. LeakBarrier NR500"T is a self -adhering, plastic film surfaced, modified underlayment; meets ASTM D1970. LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced modified underlayment; meets ASTM D1970. 4.2 Mechanically Fastened Underlayme Its: Tarco 15 is an asphalt -saturated organic felt; meets ASTM D226, Type I. Tarco 30 is an asphalt -saturated organic felt; meets ASTM D226, Type 11. Tarco NO 30 is an asphalt-saturatedi organic felt; meets ASTM D4869, Type II. LeakBarrier0 EasyLay is an asphalt -coated polyester fabric roof underlayment; meets physical requirements of ASTM D226, Types I and 11. I 4.3 Mechanically Fastened and/or Bonded Undelrlavments: 4.4 Fiberglass Mineral Surfaced Roll Roofing lis a glass -fiber -reinforced, asphalt -coated, granule surfaced underlayment used as a valley liner; meets ASTM D3909. ASTM Organic Mineral Surface Tile Underlayment is an asphalt -saturated organic roll roofing sheet; meets ASTM D6380, Class M. LeakBarrier EasyMop'" SBS is a polyester�einforced, SBS modified bitumen roofing underlayment; meets FRSA/TRI April 2012 (04-12). LeakBarrier EasyLay UDL 151consists of a woven -polymeric scrim with a textured fabric on the top surface; meets FBC 1507.1.1 (Exception) Within this Evaluation Report, it is used as a base sheet in multi- ply underlayment systems. See FBC File FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top surface; meets FBC 1507.1.1 (txception) J Within this Evaluation Report, it is used as a base sheet in multi- ply underlayment systems. Sele FBC File k1o. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top surface and a rubberized polymeric co ting on the back surface; meets FBC 1507.1.1 (Exception). Within this Evaluation Report, it is used as abase sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. 5. LIMITATIONS: i 5.1 This is a building code evaluation. Designer of Record for anyiproject used for permitting or design guidan 5.2 This Evaluation Report is not for use 5.3 Fire Classification is not part of tF Directory for fire ratings of this prod Exterior Research and Design, LLC. Certificate of Authorization #9503 V'either Trinity IERD nor Robert Nieminen, P.E. are, in any way, the which this Evaluation Report, or previous versions thereof, is/was e unless retained specifically for that purpose. i FBC HVHZ jurisdictions. s Evaluation Report; refer to current Approved Roofing Materials ct. 1 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Tarco Roof Ui derlayments; (254) 913-7750 Evaluation Report 10880.07.08-119 FL10450-R9 Revision 9:10/03/2017 Page 3 of 10 r-TRINITYIERD 5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on thislevaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1 �' ROOF , COVER OPTIONS Asphalt I Wood Shakes Underlayment Shingles Nail -On Tile Foam -On Tile Metal & Shingles Slate LeakBarrier MS300 . ,a Yes , No ;y b , , .,,. , , s� No _ Yes, Yes , LeakBarrier P5200"T Yes t yi °Yes = Yes Yes Yes I See S 5,2 LeakBarrier PS200mL' �s. Yes, p��10 r � � No �� Yet Yes -*Yesa LeakBarrier NR500"T 4 Yes;oNo� -� No Yes �` -= Ye5 Yes ocopperorzinc) LeakBarrierSS400 .Yes �'No _";,. �"No, _,_ ,_ �' •No Yes Yes jYes Yes LeakBarrier EasyLay Yes (asb sesheetm (asbasesheeti 'Yes Yes Yes multi ply system)'. " multi-plysystem) le LeakBarrier EasyLay UDL 15, Yes,. Yes Yes xYes a Yes Yes UDL Basic or UDL 50 ( see FL16884)X (as ase sheet in (as bale sheet m: (See FL16884) _ (See FL16884) (See FL16884) mint Pl0vstom) _ multiaplY system) Tarco 15 ,Yes ?„f(Ub�° , , �No ; Yes s Yes Yes > a Tarco 30 Yes (es base sheet in.- (as base sheet m x es Yes "Yes m tl�ti=plYsYstemi� in, ultr-ply system) Tarco NO30=Yeses ;NoNo Yes Yes ;Yes Fiberglass Mineral Surfaced g Vall y liner ` No �' N0 € ; N0 �� N0fi Roll Roofing per ASTM Organic Mineral a` ++ ` Cs *Yes Yes s Surface Tile Underlayment „No .x tt No N0 : N0 LeakBarrier EasyMop SBS �No Yesf es�� No No N0 ==a's, '.,-c Sees 5 2 - 4b' ,.-. 5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top layer underlayments. 5.5.2 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. >.. TABLE 1 ALLOWABLE TILE ADHESIVE % UNpERLAYMENT CONIBINATION51 r: . _ Florida Product Adhesive I Underlayments Approval LeakBarrier PS200"T, ASTM Organic Mineral Surface Tile ICP Adhesives Polyset® AH-160 I FL6332 Underlayment or LeakBarrier EasyMop SBS 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. I Evaluation Report 10880.07.08-R9 Certificate of Authorization#9503 a"' DITION (2017) FBC NON-HVHZ EVALUATION FL10450-R9 Tarco Roof Underlayments; (254) 913-7750 Revision 9:10/03/2017 IPage 4 of 10 I TRIM Y1ERD 5.6 Allowable Substrates: 5.6.1 Direct -bond to deck: LeakBarrier MS300, LeakBarrier PS200T, LeakBarrier PS200Mu, LeakBarrier NR500"T or LeakBarrier SS400 self -adhered to: ➢ New untreated plywood (unprimed or primed with ASTM D41 primer), ➢ Existing plywood (unprimed or pr�med with ASTM D41 primer); ➢ New or existing OSB (unprimed or primed with ASTM D41 primer); ➢ Structural concrete (unprimed of primed with ASTM D41 primer). 5.6.2 Note: Turco does not require priming of new or existing plywood or OSB sheathing. New or existing sheathing should be cleaned of all did and debris prior to application of LeakBarrier membranes. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: ➢ ASTM D41 primed structural coCrete. Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is foam -on tile roofing. LeakBarrier MS300, LeakBarrier I self -adhered to: ➢ ASTM D226, Type I or II felt; ➢ ASTM D4869 felt; ➢ LeakBarrier EasyLay, LeakB EasyLay UDL 50. ASTM Organic Mineral Surface Til ➢ ASTM D226, Type I or II felt; ➢ ASTM D4601, Type II base sl For installations under mechanic minimum codified requirements per minimum requirements of FI 5.6.4 herein, or as tested in actor 5.6.3 Bond to Other Substrate Type LeakBarrier MS300, LeakBarr self -adhered to ASTM D41 pri 5.6.4 Wind Resistance for Underla does not address wind uplift the underlayment forms part systems that are not address Maximum Design Pressure is and reflects the ultimate pa! already been applied). Refel determination of design wlnc #1 Maximum De. Deck: Primer: Base Ply: Underlayment: Exterior Research and Design, LLC. Certificate of Authorisation #9503 , LeakBarrier PS200mu, LeakBarrier NR500HT or LeakBarrier SS400 er EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: eet. 311y attached prepared roof coverings,'base layer shall be attached per For installations under foam -on tile systems, base layer shall be attached SA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section lance with FBC 1504.3.1. PS200RT, LeakBarrier PS200"u, LeakBarrier NR500RT or LeakBarrier SS400 ed metal (flashing metal, valley metal, etc.) �ment Svstems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) esistance of all underlayment systems beneath foam -on tile systems, where )f the load -path. The following wind uplift limitations apply to underlayment !d in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. :he result of testing for wind load resistance based on allowable wind loads, ;ing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for loads. Min. 15/32 inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction I (Optional) ASTM D41 (Optional) LeakBarrier PS200Mu, self -adhered. LeakBarrieriIPS200"T, self -adhered. i' i e' EDITION (2017) FBC NON-HVHZ EVALUATION Tarco Roof Underlayments; (254) 913-7750 Evaluation Report 10880.07.08-119 FL10450-R9 Revision 9: 10/03/2017 Page 5 of 10 i jl TRINITYERD #2 Maximum Design Pressure = -120.0 psf:j Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional) ASTM D41 I Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200Mu or LeakBarrier EasyBase, rolled into place to create continuous bond Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered Underlayment: LeakBarrier PS200"T, self -adhered. #3 Maximum Design Pressure = -217.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered Underlayment: LeakBarrier PS200"T, self -adhered. #4 Maximum Design Pressure -= -45.0 psf*: Deck: Min. 15/32-inch pl i ood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered Underlayment: LeakBarrier P5200"I, self -adhered. #5 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-incI4 long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps I Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered Underlayment: LeakBarrier PS200"T, self adhered. #6 Maximum Design Pressure = -60.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the flinch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered Underlayment: LeakBarrier PS200"T, self -adhered. #7 Maximum Design Pressure =' 82.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. I Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered Underlayment: LeakBarrierlPS200"T, self -adhered. i I I I Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R9 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.30450-119 Tarco Roof Underlayments; (254) 913-7750 Revision 9:10/03/2017 Page 6 of 10 #8 Maximum Design Pressure = -120.0 Deck: Min. 15/32-inch ply Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch for diameter tin caps Spacing: 4" o.c. at the 4-inch wl Base Ply: (Optional) LeakBarrier Underlayment: LeakBarrier PS200"T, s 5.6.4.1 All other direct -deck, adhered Ta Maximum Design Pressure of -45 psi 5.6.4.2 For mechanically attached Base She or exceed that required under FRSA Alternatively, the maximum desi design pressure determined in a attachment density designed by Commonly used methods are A Application Standard RAS 117. Section 2.2.10.1 of FM Loss Prev( to meet project requirements to satisfaction of Authority Having x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch side laps and 4" o.c. at four (4) equally spaced, staggered center rows. 200mu, self -adhered adhered. underlayment systems beneath foam -on tile systems carry a et, the maximum design pressure for the selected assembly shall meet /TRI April 2012 (04-12), Appendix A, Table 1A. pressure for the selected assembly shall meet or exceed the Zone 1 Irdance with FBC 1609. In this case, Zones 2 and 3 shall employ an qualified design professional to resist the elevated pressure criteria. SI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing ,semblies marked with an asterisk* carry the limitations set forth in ion Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: LeakBarrier EasyLay, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SBS shall not be left exposed for longer than 180-days after installation. LeakBarrier PS200"T shall not be left exposed for longer than 120-days after installation. LeakBarrier MS300, NR500"T, PS200""u or SS400 shall not be left exposed for longer than 30-days after installation. Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for more than 24 hours after instillation could adversely affect performance. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. • TABLE 2: TILE SLIPPAGE LIMITATIONS FOR;DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope "T LeakBarrier P5200 Flag 10-tile stack or 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 6:12 LeakBarrier EasyMop SBS Flat 6-tile stack (4 over 2) 5:12 Lugiged 6-tile stack (4 over 2) 6:12 Exterior Research and Design, I.I.C. Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION Tarco Roof Underlayments; (254) 913-7750 Evaluation Report 10880.07.08-R9 FL10450-R9 Revision 9:10/03/2017 Page 7 of 10 i i f i T,,.TR1NJTYJ.ERD i 6. INSTALLATION: i 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing published installation requirements subject to the Limitation's set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications: Cut to manageable sections and allow to relax prior to application. Membrane Application: ➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend approximately 3/8" over the eave and rake with the selvedge edge positioned upslope. ➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges ➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3" onto the deck surface. ➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the substrate from the centerline out. ➢ Seal all 6" end laps with a 1116" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Remove selvage release film, if present„and install second and subsequent courses in a similar manner. ➢ Install capped or tin -tagged nails 6" o.c. along the centerline of the laps. ➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps cement before the overlappiI g course is laid. ➢ Roll the entire surface with a weighted' roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a comiplete bond. 6.3.3 Tile Applications (PS200"' only)': Reference is made to FRSA/ IRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. For mechanically fastened the l roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set the applications, refer to Section 5.6.4 herein. Refer to Section 5.8 for tile staging limitations. If tiles are to be left in a staged condition for more than 30 days, Tarco Roofing requires tiles be staged two tiles perpendicular to slope, four tiles on top, parallel to slope, regardless of the allo i ance in Section 5.8. 6.3.4 Multi -Ply Underlayment Systems: LeakBarrier° SS400 Ice andilWater Armor followed by LeakBarrier° SS400 Ice and Water Armor (direct -to - deck per 5.6.1 or over mechanically attached base sheet per 5.6.2) is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. Exterior Research and Design, U.C. Certificate of Authorization #9503 i C" EDITION (2017) FBC NON-HVHZ EVALUATION Tarco Roof Underlayments; (254) 913-7750 i Evaluation Report 10880.07.08-R9 FL10450-R9 Revision 9: 10/03/2017 Page 8 of 10 I I T,-TRINITYIERD 6 4 ta'�co 15 and 30. 6.4.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for„ASTM D226, Type I (Tarco 15) or ASTM P q D226 Type II (Tarco 30) underlaymentlin FBC Table 1507.1.1 for the type of prepared roof covering to be installed. I 6.4.2 Tile Applications (Tarco 30 only): Tarco 30 is limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. I 6 5 Tarco N6 6.5.1 Shall be installed in compliance witk the codified requirements for ASTM D4869, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6 LeakBarner-EasyLay: , 6.6.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Non -Tile Applications: Place a full width section of EasyLay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay lines facing up, and position to the edge of the eave and rake. install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or 1" capped (plastic or metal) nails1, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to avoid walking or kneeling on ui secured sheet. Continue to the end of the substrate and fasten down. Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding laps and minimum 8" end -laps, which are staggered minimum 36" fro the preceding course. For double layer applications, follow the instructions noted above, but using a minimum 19", water - shedding side lap. Allow for minimum 6" up the vertical transitions and minimum 6" over hips and ridges. At valleys, first install a vertic�1 length of EasyLay down the center of the valley, then start at the low point and work to the high point, rolling the membrane from the center outward in each direction, ensuring no wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA recommendations. Apply a thin coat of asphalt )plastic cement to waterproof areas where any cuts or tears have occurred. Seams or joints that require, dhesive or sealant can be treated with high quality plastic cement (asbestos free). 1 I 6.6.3 Tile Applications, base layer in multi -ply system: LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual i I Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-119 Certificate ofAuthari:ation #9503 eli EDITION (2017) FBC NON-HVHZ EVALUATION FL10450-R9 Tarco Roof Underlayments; (2S4) 913-7750 Revision 9:10/03/2017 Page 9 of 10 I I ' i 6.7.1 Shall be installed in compliance with cu tile applications: ✓ ASTM Organic Mineral Surface Til alternate to "Mineral Surface Roll FRSA/TRI April 2012 (04-12) ben applied "Cap Sheet" in the "Two P fastened or adhered tile roof systel Tarco Roofing published installation requirements. For use in Underlayment and LeakBarrier'"' EasyMoD SBS are for use as an Roofing" (ASTM D6380, Class M) in the "Single Ply System" from path mechanically fastened tile roof systems or the Hot Asphalt System" from FRSA/TRI April 2012 (04-12) beneath mechanically 6_8 Tile Staging: 6.8.1 Tile shall be loaded and staged 19 a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herel In, and Tarco Roofing published requirements for tile staging. 6.8.2 Battens and/or Counter -battens, as lequired by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to preventi tile sliding and/or damage to the underlayment during the loading process. 6.8.3 Tarco Roofing specifies the minimu I cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authorii y Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted CIA agency for informatio ion product locations covered for F.A.C. 61G20-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plarit> 5oecifieatio i` r� 'Products ASTM D226 LeakBarrier EasyLay, Tarco 15, Tarco 30 ASTM D4869 Tarco NO 30 ASTM D3909 Fiberglass Mineral Surfaced Roll Roofing Greencastle, ASTM D6380 ASTM Organic Mineral Surface Tile Underlayment PA ASTM D1970 I LeakBarrier MS300 Ice and Water Armor, LeakBarrier PS200 Ice and Water Armor, LeakBarrier SS400 Ice and Water Armor ASTM D1970 & FRSA/TRI 04-2612 LeakBarrier PS200HT Ice and Water Armor FRSA/TRI 04-2012 LeakBarrier EasyMopTM SBS ASTM D226 LeakBarrier EasyLay, Tarco 15, Tarco 30 ASTM D4869 Tarco NO 30 Belton, TX ASTM D1970 I MU LeakBarrier MS300 Ice and Water Armor, LeakBarrier PS200 Ice and Water Armor, LeakBarrier SS400 Ice and Water Armor ASTM D1970 & FRSA/TRI 04-2012 LeakBarrier PS200 Ice and Water Armor Coshocton, OH ASTM D1970 HI LeakBarrier NR500 Gujarat, India FBC 1507.1.1 (Exception) LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic, LeakBarrier EasyLay UDL50 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 Exterior Research and Design, LLC. Certificate of Authorization #9503 - END OF EVALUATION REPORT - I i i 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Tarco Roof Underlayments; (254) 913-7750 Evaluation Report 10880.07.08-R9 FL10450-R9 Revision 9: 10/03/2017 Page 10 of 10