PRODUCT REVIEW - GENERATOR
Protector® QS Series INCLUDES: SCANNED By st L,�f"IPPA W • Two Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of gene# status and breaker position.ir =t • True PowerT"' Electrical Technology;` •`4 V • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1%Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed • Capability to be installed within 18" (457) mm of a building* *Only if located away from doors, windows, and fresh a intakes, and unless otherwise directed by local codes. FEATURES GENERAL' PROTECTOR® QS SERIES Standby Generators Liquid -Cooled Gaseous Engine Standby Power Rating tMi4gtjG d ,�' _ _ = Bis )�2�2"0 IM1114, Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz 6d6l RG038 (Aluminum - Bisque) - 38 kW 60 Hz iMbdel RG048 (Aluminum - Bisque) - 48 kW 60 Hz ST.LUCIE COUNTY PLAN REVIEW BLDG:___ DATE: ELEC DATE.Ie — / PLUMB:_ DATE:___ MECH:____ DATE:,_,__ I O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O TEST CRITERIA: r �9S COOT OQUIEfiEST- Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 32 & 38 kW not for sale in CA / MA O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. 4 PROTOTYPE TESTED 4 NEMA MG1-22 EVALUATION O GENERAC TRANSFER SWITCHES. Long life and reliability are 4 SYSTEM TORSIONAL TESTED 4 MOTOR STARTING ABILITY synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. 00 9001: 200H 1 � GENERAC® 2-2 • 27 • 32 • 38 * 48 kW application & engineering data GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS27, 32 & 38 kW Type Synchronous Rotor Insulation Class H (22 i& 27 kW) or F (32, 38 & 48 kW) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System i Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ± 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) or Group 24F (481kW), 525CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather Ensures protection against mother nature. protective enclosure Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade Quiet, critical grade muffler is mounted inside the unit muffler to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271) Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41/86.5 Stroke (iNmm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turbocharged/Aftercooled (32 & 38 kW) Lifter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Generac Model V Type Cylinders 8 Displacement (Liters) 5.4 Bore (in/mm) 3.55/90.2 Stroke (iNmm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 (22, 27, 32 & 38 kW) or Crankcase Capacity (qVl) 6/5.7 (48 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven 1980 - 22 & 27 kW Fan Speed (rpm) 1500 - 32 & 38 kW 1954 - 48 kW 18.1/459.7 (22 & 27 kW) or Fan Diameter (tn/mm) 22/558.8 (32, 36 & 46 kW) Pusher (22 & 27 kW) or Fan Mode Puller (32, 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG LP Fuel Pressure 11 -14" Water Column NG Fuel Pressure 5 -14" Water Column C c GENERAC® 22 • 27 • 32 • 38 • 48 kW operating data GENERATOR OUTPUT VOLTAGEAW - 60 Hz kW LPG Amo LPG kW Nat. Gas Amp Nat. Gas CB Sae (Both) _.m---=-. �92 _-r--t--,-100 .,� f�L�G022 y 120/208 V, 30, 0.8 pf 22 76 22 76 80 120/240 V, 30, 0.8 pf 22 66 22 66 80 120/240 V. 10, 1.0 pf 27 1 113 25 104 125 RG027 120/208 V, 30, 0.8 pf 27 94 25 87 100 120/240 V, 30, 0.B pf 27 81 25 75 90 120/240 V, 10, 1.0 pf 32 I 133 32 133 150 1201208 V, 30, 0.8 pf 32 111 32 111 125 RG032 120/240 V, 30, 0.8 pf 32 96 32 96 100 277/480 V, 30, 0.8 pf 32 48 32 48 60 120/240 V,10,1.0 pf 38 158 38 158 175 120/208 V, 30. 0.8 pf 38 I 132 38 132 150 RG038 120/240 V, 30, 0.8 pf 38 j 114 38 114 125 277/480 V, 30, 0.8 pf 38 57 38 57 60 120/240 V,10,1.0 pf 48 200 48 200 200 120/208 V, 30, 0.8 pf 48 167 48 167 175 RG048 120/240 V, 30, 0.8 pf 48 144 48 144 150 277/480 V, 30, 0.8 pf 48 72 48 72 80 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @ < .4 pf Natural Gas Propane 15% 30% (ft3/hr) (m3/hr) (gaVhr) (Vhr) (ft3/hr) tRG0 -f20/240V-10 120/208 V, 30 40 92, 120/240 V. 30 35 80. RG027 120/240 V, 10 62 170 120/208 V, 30 70 120 120/240 V, 30 61 103 120/240 V, 10 75 180 120/208 V, 30 87 216 RG032 120/240 V, 30 75 182 277/480 V, 30 36 87 120/240 V, 10 75 180 120/208 V, 30 87 210 RG038 120/240 V, 30 75 182 277/480 V, 30 36 87 RG048 120/240 V. 10 85 195 120/208 V, 30 90 218 120/240 V, 30 78 189 277/480 V, 30 36 1 87 Note: Fuel pipe must be sized for full load. For Btu content, multiply ft3/hr x 2520 (LP) or W/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. Exercise cycle 34 1.0 0.4 1.4 13 25% of rated load 142 4.0 1.4 8.2 1 52.5 1&227 s50% of rated load 207 5.9 2.1 7.8 78.6 75% of rated load 274.6 7.8 2.9 10.9 104 100% of rated load 342 9.7 1 3.6 13.7 129.7 Exercise cycle 40 1.1 0.4 1.7 15 25% of rated load 155 4.4 1.6 6.2 1 58.7 RG027 50% of rated load 233 6.6 2.6 9.5 90.4 75% of rated load 314 8.9 3.3 12.7 121 100% of rated load 396 11.2 1 4.1 15.7 149 Exercise cycle 44 1.3 0.5 2 19 RG032 25% of rated load 138.8 3.9 1.5 1 5.7 53 50% of rated load 218.8 6.2 2.6 10.2 1 94.9 75% of rated load 301 8.5 3.7 14.2 132 100% of rated load 380.6 10.8 4.6 17.6 166 Exercise cycle 44 1.3 0.5 2 19 25% of rated load 156 4.4 1 1.7 6.4 60 RG038 50% of rated load 260 7.4 3 1 11.4 107.8 75% of rated load 361.7 10.2 4.2 16.2 153 100% of rated load 444 12.6 5.4 20.4 192 Exercise cycle 63 2.0 0.9 3.3 31 25% of rated load 270.6 7.7 3.1 11.7 110.9 RG048 50% of rated load 425 12.0 5.0 19 151 75% of rated load 557.7 15.8 6.8 25.8 244.5 100% of rated load 638 18.5 8.7 33 312 STANDBY RATING: Standby ratings apply to installations served by a 'reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance wit1 ISO-3046-1. Design and specifications are subject to change without notice. GENERAC® 22 • 27 • 32 • 38 a 48 kW operating data ENGINE COOLING 27 kW 32 & 38 kW 48 kW Air flow (inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2 System coolant capacity (gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 3/11.4 Heat rejection to coolant (BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 186,000/196.2 Maximum operation air temperature on radiator (°C/°F) 60/150 Maximum ambient temperature (°C/°F) 50/140 COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm) 1 68/1.9 1 68/1.9 1 106/3 1 163/4.6 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode' 1 1 61 1 61 1 58 1 63 Sound output in dB(A) at 23 It (7 m) with generator operating at normal load' 1 70 1 70 1 64 1 68 *Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) 165/4.7 1 180/5.1 1 300/8.5 414/11.7 Exhaust temperature at muffler outlet (°C/°F) 482/900 1 538/1000 1 579/1075 552/1025 ENGINE PARAMETERS Rated Synchronous rpm 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration..........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 OF above 77 °F Altitude Deration (22, 27 & 48 kW).....................................................................................1 % for every 100 m above 183 m or 3% for every 1000 ft above 600 It Altitude Deration (32 & 38 kW).......................................................................................1 % for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES 2-Line Plain Text LCD Display.................................................:......................................................................................Simple user interface for ease of operation. Mode Switch: Auto..............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser Off...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual............................................................ :............................ Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds............................................................................................................................................................ Standard Engine Start Sequence..................................................................................................................... Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration) EngineWarm-up.....................................................................................................................................................................................................................5 sec EngineCool-Down..................................................................................................................................................................................................................1 min Starter Lock-out................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger............................................................:........................................................................................................................................... Standard Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................ Standard AutomaticLow Oil Pressure Shutdown............................................................................................................................................................................... Standard OverspeedShutdown.............................................................................................................................................................................................. Standard, 72 Hz HighTemperature Shutdown............................................................................................................................................................................................... Standard OvercrankProtection..........................................................................................................................................................................................................Standard SafetyFused......................................................................................................................................................................................................................Standard Failureto Transfer Protection..............................................................................................................................................................................................Standard LowBattery Protection........................................................................................................................................................................................................ Standard 50 Event Run Log ........... ...... -... ........... ........................................................................... .............. ............... ............................................. ....... ........... ....... Standard FutureSet Capable Exerciser..............................................................................................................................................................................................Standard IncorrectWiring Protection................................................................................................................................................................................................. Standard InternalFault Protection..................................................................................................................................................................................................... Standard CommonExternal Fault Capability.........................................:............................................................................................................................................Standard GovernorFailure Protection................................................................................................................................................................................................ Standard GENERAC® 22 • 27 • 32 • 38 • 48 kW available accessories Model # Product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with G006463-4 Mobile Link'"" any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. G006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid -cooled units compatible with Mobile LinkTm G005630-1 - 22, 27, 32 & 38 kW If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit Cold Weather Kit I to maintain optimal battery temperature. Kit consists of battery warmer with G005632-1- 48 kW I thermostat built into the wrap. G005616-0 - 22, 27, 32 & 38 kW Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for G007088-0 - 48 kW Weather Kit extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit i Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to G005703-0 - Bisque Paint Kit touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G005656-0 - 22 & 27 kWSchedu ed The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware G005984-0 - 32 & 38 kW Maintenance Kit I necessary to perform complete maintenance on Generac liquid -cooled G006205-0 - 48 kW generators. G006664-0 Local Wireless Completely wireless and battery powered, Generac's wireless remote monitor Monitor provides you with instant status information without ever leaving the house. G006665-0 Wireless Remote Recommended for use with the Wireless Remote on units up to 60 kW, Extension Harness required for use on units 70 kW or greater. 1 Smart Management Modules are used in conjunction with the Automatic G006873-0 Smart Management Transfer Switch to increase its power management capabilities. It provides Module (50 Amps) additional power management flexibility not found in any other power management system. G006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. RADIATOR/EXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES) (BOTH SIDES) BATTERY 12 [''[ GRP 26 I I NEGATIVE GROUND JVL P/N:077483 REMOVE COVE FOR ACCESS TO RADIATOR FILL CAP p 108 e I 427 [16.8] EXHAUST MUFFLER — ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR 141 629.9 [24.8] [5-8] CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW I OIL DRAIN HOSE I LEFT SIDE I REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 980 [38.6] OVERALL HEIGHT 1040 48 [40.9] 11.91 FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW v 0 00 w NOTES: N .A. 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (4T) WIDE X 1885 (74.2) LONG.co REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT O APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. v 3. CONTROL PANEL CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8.11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. — — _ 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. REAR ENCLOSURE COVER PANEL SEE NOTE 4 USTOMER ACCESS .••�i •d* ASSEMBLY, CONTROL • PANEL ACCESS, -- - BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 776 [30.6]� OVERALL WIDTH REAR VIEW WEIGHT DATA ENGINEIKW ENCLOSURE WEIGHT WEIGHT ONLY WEIGHT SHIPPING SKID SHIPPING WEIGHT MATERIAL KG [MI KG [LSS] KO [LSS] 2AL 22KW AL 410.5 [9051 30 [6S1 440 [9711 24L 27KW AL 426 [9401 30 [66] 1 458 [1006] 48 - 11.9] TYP 45 - [1.8] TYP DIMENSIONS: MM [INCH] OVERALLLENOTH RIGHT SIDE VIEW VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR 45 [1.8] LEFT SIDE VIEW DIMENSIONS: MM [INCH] REAR VIEW 3.8] CD 0 co N W N O wi Automatic Transfer Switches GENERAL' Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase C @us LISTED -"1nft=ushv .Wf-IgnPb *CUL only applies to non -service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an EvolutionT" or Nexus" Controller. The 100f200, nd 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RTSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 313 enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty: * Non -service rated (RTSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. 4 GENERAC® 100-400 Amps, Single Phase Automatic Smart Transfer Switches Functions All timing and sensing functions originate in the generator controller Utilityvoltage drop-out......................................................................................................................................................................................................................<60% Timer to generator start................................................................:.................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer' Engine warm up delay............................................................... ...:................................................................ .............................................................................. 5 seconds .Standby voltage sensor.................................................................................................................................................................................................60% for 5 seconds Utilityvoltage pickup.........................................................................................................................................................................................................................>80% Re -transfer time delay.................................................................ii.............................................................................................................................................15 seconds ii Enginecool -down timer...........................................................................................................................................................................................................60 seconds Exerciser.................................................................................... 4.........................................................................................................................12 minutes every 7 days The transfer switch can be operated manually without power applied. 'When used in conjunction with units utilizing Evolution- controls Specifications Model RTSC10OA3 RTSW100A3 RTSW150A3 RTSC200A3 RTSWZOOA3 ) RTSW3O0A3 RTSC400A3 RTSW40OA3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240,16 120/240,1 a 12O/24O,1e 120/240,1 a 120/240, 1 e 120/240,1 a 120/240, 1 o 120/240, 1 e Load Transition Type (Automatic) Open Transition Open Transition Service Rated !Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 311 NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R NEMA/UL 313 NEMA/UL 311 NEMA/UL 3R NEMA/UL 313 UL Rating UUCUL UL UL UUCUL UL UL UUCUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MCM - #6 600 MCM - #4 or 1/0 - 250 MCM Dimensions Model RTSC100A3 RTSW100A3 RTSW150A3 RTSC200A3+ RTSW200A_'tiTSW300A3 RTSC400A3 RTSW400A3 Height Hl 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 (inJmm) H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 48/1219.2 Width W1 12.5/317.5 12.5/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 (inJmm) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth (in./mm) 7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.3/160.1 10.06/255.5 10.06/255.5 10.06/255.5 Weight (Ibs /Idlos) 20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 DEPTH DEPTH GENERAC® Generac Power Systems, Inc. • S45 W2929O HWY. 59, Waukesha, N 53189 • generac.com ©2015 Generac Power Systems, Inc. All rights reserved. All specifications an: subject to change without notice. Bulletin OL3205-8 Printed In U.S.A. 07/28/15 I 4 w e uY $ La I co dlq c t w a'o 0 r U r2: y / 48M SW HONEY TERRAG�E W n. o ! PALM CITY, FL 349990 4 1 pHONM0=486.2947 v 0 Q 0: a N 12��3C� =of 0ao i / s cp Mgt a f M �& It � p CV iga $ G w i► / 1 y� Q M \ 4 4 • t co .$ ,,o tog .... �n 29 CF i `/ X�' .�� JIM REISNER ELECTRIC, LLC 4886 SW HONEY TERRACE PALM CITY, FL 34990 EC-0002442 (772) 260-0732 LOAD CALCULATIONS Ried Residence 3051 sq/ft X 3VA Dishwasher Disposal Microwave Refrigerator Appliance X 2 Washer Pool Pump Garage Door Opener Dryer Water Heater GAS Range/Oven TOTAL 9153 VA 1200 VA 600 VA 800 VA 1000 VA 3000 VA 1500 VA 1200 VA 600 VA 4500 VA 0000 VA 10000 VA 33553 VA 1st 10 KVA + 40% of 23553 KVA 19421 VA HEAT 1-10 KW & 1-5 KW @ 65% 9750 VA Use SMM Load Shed Modules 0000 VA TOTAL LOAD: 19421 VA USE 22 KW GENERATOR �N ��ti`'��fa �h d• ST.LUCIE'COUNV pLAN� Ew BLDG:---- — DATEC:��e��f DATE PLUMS:--- DAle - MEWI=- DATE:--- ZA) dVt P�6�C�W 0 zap � 6onsw c + E TE - RAM pALM CITY, FL 34990 tnz) 28M R VLnI L--5r--/ALcr-W .x V6,uj 4& ioa. pGp G"-%- - �ctiv +ZlSER.. o2"Q,,� 0,9; -TO -?"gs 4,D 146 �Kl