Loading...
HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVIT 7-27-18GGAN NW, Planning & Dehe% rWO ices Department Building & Regulations Division Product Review Affidavit f JUL 2 7 rSl'-cie County, Pe,mitt;',,', ' Building Permit # XSQLA " COl (p \ Owners Name bLNL?_'1v1c &loa Q�Iny c.>S Applicant: Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows +32.37/-42.62 +50/-60 DP Ply Gem Series 4712 Flange FL 14039.1 Non -Impact p 10 Wood Screw with sufficient length to achieve 1-1/4"embedment Required anchors: Head(3), Jamb(3) Mullions N/A +/-75 DP Ply Gem Series 4700 Flange FL 15264.2 N/A UseY.' Tapcon with sufficient length to achieve a 1X' minimum embedment with 2 Y.' minimum edge distance. Fixed Glass +29.65/38.87 +/-55 DP Ply Gem Series 4701 Flange FL 14434.1 Non -Impact 910 Wood Screw with sufficient length to achieve 1-1/4'embedment. Required anchors: Head(3), Jamb(3) Block Glass N/A N/A --N/A- N/A N/A N/A N/A Skylights N/A N/A N/A N/A N/A N/A - N/A Sliding Glass Doors +28.74/-42.62 +/-50 DP Ply Gem Series 4780 FL 14634.2 Non -Impact 3/16' Topmn with sufficient length to achieve 1-1/4'embedment. Requimdanchom:Head/SEI(a).Jamb(5)lachwindmv. Swing Type Doors +30.64/-30.64 +67.0/-67.0 ThermaTru 39kB'0'SmoothSlarFlberglass FL5891.5 N/A WTepmn Y.',MnEmbedmeni l-tfd',Mn Clea enmbedge 2,kTm Ceamnm oediamnt entivd'; OR F1C0 Tepmn lfd'.Mn French Doors N/A N/A N/A N/A N/A N/A N/A Garage Doors +25.91/-31.39 +361-42 Clopay 16X7 Model 73W6 FL16546.4 N/A Jamb to black onveNceljamb 114'%1114'min embedded Tapmn. Max spacing of 712'and V OD steel washer required. Hurricane Protection N/A +40/-40 Eastern Metal Supply 24ga Steel Panels FL 11964.2 N/A 1/4" Tapcon Anchors, SG Tapcons or 1/4" X 314". All points Solid -set Anchors. Roof Ventilation I I I I I I N/A Roofing Material N/A N/A �Tamko� N/A �FL18355.1 N/A S palls par sbingla. Standard type roofing nag, nail shanks should be 12 gauge wire and minimum head of 3/3'. Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in this wind loads and forces specified by current code provisions. Name: JAMES JOSEPH CANTWELL Signature: Design Prof: ARCHITECT ST. LUCIE COUNTY 3UILDING DIVISION REVIEWED FOR COMPLI C HF Vrt_W EW B PLANS AND MUST BE KEPT Cert. No. AR00120 ARE SU'5JECT TO ANY CORRECTIONS REQUIRED WY FIELD IMFECTOnS T hAT WAY DE NECESSARY IN ORDER TO COMVI:( WITH I ALL APPLIC RI F CODES. nR These products provide adequate resistance to the Date: 0 6/2 6/ 18 CONCEALED FASTENERS OR ATTACHMEKI ARE -THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD , seal