HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMENT ROOF SYSTEMBCIS Home � Log In j User Registration Ho[Topia i Submit Surcharge Stats &Fads
I '
Publications FBC staff ? BQS Site Map , Links ` Search i
�oliea
SroR uct Approval
j Vic:^act Aooroval Menu > Product or Application Sea7,--.
eta���,.f/�/FL # �1((ApplicatlonType ST. LUCIE COUNTY BUILDING DIVISION
CodeversionREVIEWED FOR COMPLIANCE
Application status REVIEWEYDATEPLANS AN PERMIT MUST BE PT ON JOB
commentsSITEORNOINSPECTIONS)WILLBEMADE
Archived
Year
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1378 Ext242
alender@polyglass.com
Authorized Signature Ariel Lender
alender@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAlpert@polygiass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1230
ALender@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report'
Florida License
Quality Assurance Entity
Quality Assurance Contract Ex
Validated By J
piration Date
,
Certificate of Independence
i
I
Referenced Standard and Yea
i
I
i
r
i-
I
1 '
r (of Standard)
PE-59166 THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
UL LLC
REQUIRED BY FIELD INSPECTORS THAT
SO/06/2018 MAY BE NECESSARY IN ORDER TO
John W. Knezevich, PE COMPLY WITH ALL APPLICABLE CODES.
Validation Checklist - Hardcopy Received
FL1654 R22 COI
2017 01 COI Nieminen.odf
Standard
ASTM D6162
ASTM D6163
ASTM D6164
ASTM D6222
ASTM D6509
FM 4470
FM 4474
UL 1897
2008
2008
2011
2011
2009
2012
2011
2012
FILE COPS'
1' C®(yC�11„ED PAailtitvERS 6R AT'TACHME�ITS
ARE THE RESPONSIBILITY OF THE
� cIf1NTRACTOR OR RECORD
N
M
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summaryof Products
Method i Option D
09/14/2017
09/15/2017
09/22/2017
12/12/2017
FL #
Model, Num�er or Name
Description
1654.1
Polyglass SBS and APP
Modified Bit6men Roof
SBS and APP modified bitumen roof systems
Systems
Limits of Use
Approved for use in HVHZ: No
installation Instructions
FL1 i-4 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
R22.adf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL1654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL1654-
Approped for use outside HVHZ: Yes
Impact Resistant: N/A j
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure in this
application relates to one particular assembly
over concrete deck. Refer/to the ER Appendix for
R22.odf
other systems and deck types. 2.) Refer to ER,
Created by Independent Third Party: Yes
Section15 for other Limits of Use.
back tie#
Contact Us •• 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/E'0 employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be/used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the T
rtment with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S.,-please
,- dick her .
Product Approval Accepts:
= WN tgri
-19
Credit Card ,
Safe
'w \t le
f
Y �
- J TRINITY; ER®.
4. Minimum 200 psi, minimum 2-Inch thick lightweight insulating concrete may be substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square.
➢ Dow INSTA STIK Ctuik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.
D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-Inch o.c.
Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 Is referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,12-Inch o.c.
> Note: When multiple layers(s) of Insulation and/or coverboard are Installed In ribbon -applied adhesive, board /oints shall be staggered.
D Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all Insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
r Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf (Min. 0.5-inch thick)
D OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-Inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (08500): MDP -187.5 psf (Min. 0.5-Inch thick ISO 95+ GL)
D OMG OlyBond 0 (OB500): MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3)
Y. OMG OlyBond 500-(08500): MDP -487.5 psf (Min. 0.5-Inch thick ACFoam 11)
➢ ICP Adhesives & Sealants CR-20 ` MDP -117.5 psf (Min.1,0-Inch thick)
88. Bonded poiylsocyanurate Insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure -for -the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to -resist -the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies m ra ked-with,an -asterisk* carrythe limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16-, and -no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to -the-_
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing In accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, I.I.C. d/b/a Trinity) ERD
Certificate of Authorization #9503
Prepared by: RobertNieminen, PE-59166
6TM EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Evaluation Report P9290.02.08-R20 for F1.3654-1122
Revision 20: 09/12/2017
Appendix 1, Page 2 of 58
ER®
TRINI1i� ..
APPENDIX 1 ATTACHMENT REQUIREMENTS'FDR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
Page
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
18-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
113-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
1C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
11
1D
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
1F-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
117-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
19-21
1G
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
21
22-24
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
_ 40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
58 ---CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
47
5C
CWF �_
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
48
qg
SD
CWF New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
SE
CWF
New, ReroofjTear-Off)-or_Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
qg
6A
Gypsum
Reroof (Tear -Off)-- _A-1
Bonded Insulatio B d An f C
qg
n, one o0 over 50-52
6B Gypsum Reroof (Tear -Off) or Recover A-2 `Mech.-Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52
6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation; Bonded Roof Cover 53
6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet,-Bonded_Roof Cover 53
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 54-58
78 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover - —� 58
The following notes apply to the systems outlined herein-
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
D Wood: Minimum 0.75-inch penetration.
D Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
Y Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturers published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-R20 for FL3654-R22
Certificate of Authorization #i9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prgpared by: Robert Nleminen, PE-59166 Polygiass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58
Li
ERt�
J TRINITY
TABLE IF-:1: WOOD DECKS= NEW CONSTRUCTION oR REROOF.(TEAR-OFF )
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET(NAILS), BONDED ROOF COVER
System
Deck (Note 1)
Base Sheet
Roof Cover (Note 15)
MDP
Type
Fasten
Attach
Base Ply
Cap Ply
No.
W-88
19/32
EI tobase, Elastobase P
-5/8•irtch dl meter ti_ caps with 1 ga nnula
-Inch in -It i lap nd 6 inc o. in fou
one
5+1SA 5B A; ,
.� i
-122�5
inch plywood
rings ank ails' }
(4), equally spaced, stapgeryd,center rowsmilillIllill,
ETA
W-89
Min.19/32-
Elastobase, Elastobase P (poly -film
32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular
ring shank nails. Note: Tin caps are to be primed with
6-Inch o.c. In 4-inch lap and 6-Inch o.c. in four
None
SB SA, PP -SA
-112.5
Inch plywood
top)
PG100 orASTM D41 primer.
(4), equally spaced, staggered center rows
t ASP.HAIT A466 OR TORCH -A_ P uc BASE f
W-90
Min. 15/32-
Elastobase, Elastobase P
Simplex MAXX Cap
9-Inch o.c, at 2-Inch lap and 18-Inch o.c. In two
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
-45.0'
inch plywood
(2), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP-TA
W-91
Min. 15/32-
Elastobase, Elastobase P
Simplex MAXX Cap
9-Inch o.c. at 2-inch lap and 12-inch o.c. in two
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
-52.5
Inch plywood
(2), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP-TA
W-92
Min. 15/32-
Elastobase, Elastobase P
Original Simplex Cap Nails (1-inch metal head diameter,
6-Inch o.c, at 3-inch lap and 6-Inch o.c. in four
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
-52.5
Inch plywood
31 gouge x min. 1.25-Inch long annular grooved shank)
(4), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP-TA
W-93
Min. 15/32-
Polyglass APP Base
Original Simplex Cap Nails (1-Inch metal head diameter,
6-Inch o.c. at 3-Inch lap and 6-Inch o.c. In four
APP-TA
APP-TA
-52.5
Inch plywood
11 gauge x min. 1.25-inch long annular grooved shank)
(4), equally spaced, staggered center rows
Elastobase, Elastobase P, Polyglass
MIn.19/32-
G2 Base, CertalnTeed Glasbase,
Firestone MB Base, IM Perma-Ply
32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular
8-Inch o.c. in 4-Inch lap and 8-inch o.c. in three
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
Inch plywood
P
28, Tamko Glass Base or GAFGLAS
ringshank nails
(3), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP-TA'
60.0
#175
W-95—
Min. 15/32-
Polyglass G2 Base, Elastobase,
32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular
B-inch o.c. in 4-Inch lap and 8-inch o.c. In four
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
Inch -ply -Wood-
_Elastobase P
ring shank nails
(4), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP•TA
67.5
W-96
Min. 15/32-
Polyglass APP Base
32 ga., 1-5/8-Inch diameter tin caps with 11 ga. annular
8-Inch o.c. In 4-Inch lap and 8-Inch o.c. in four
APP-TA
APP-TA
67.5
Inch plywood
ring shank nails
(4), equally spaced, staggered center rows
W-97
Min.15/32-
Polyglass G2 Base, Elastobase,
Simplex MAXX Cap
30-Inch o.c, in 4-inch lap and 10=Inch o.c, In
-three (3), equally spaced, staggered center
BP -pip SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
-75.0
Inch plywood
Elastobase P
TA, APP-TA
AA, SBS-TA, APP-TA
rows
Min. 15/32-
10-Inch o.c. in 4-inch lap and 10-inch o.c. in_-
W-98
Inch ri+�
p I ood
Polyglass APP Base
Simplex MAXX Cap
three (3), equally spaced, staggered center
APP TA -' -
APP-TA___
-75.0
rows
-
l--
W-99
Min. 15/32-
Polyglass G2 Base, Elastobase,
Simplex MAXX Cap
9-inch o.c. in 4-Inch lap and 9-inch o.c, in four
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
-90.0
Inch plywood
Elastobase P
(4), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP-TA
W-100
Min. 15/32-
Polyglass APP Base
Simplex MAXX Cap
9-inch o.c. in 4-inch lap and 9-Inch o.c. in four
APP-TA
APP-TA
-90.0 '
Inch plywood
(4), equally spaced, staggered center rows
W-101
Min. 15/32-
Elastobase, Elastobase P
Simplex MAXX Cap
6-Inch o.c, at 2-Inch lap and 6-Inch o.c. in two
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
90.0
Inch plywood
(2), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP TA
W-102
Min. 15/32-
Elastobase, Elastobase P
Simplex MAXX Cap
6-inch o.c. at 2-inch lap and 6-inch o.c. in three
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
-105.0
Inch plywood
(3), equally spaced, staggered center rows
TA, APP-TA
AA, SBS-TA, APP-TA
W-103
Min. 19/32-
Elastobase, Elastobase P
32 ga., 1-5/8-Inch diameter tin caps with 31 ga: annular
6-inch o.c, in 4-inch lap and 6-Inch o.c, in four
BP -AA, SBS-AA, SBS-
SBS-SA, APP-SA, SBS-
.112.5
Inch plywood
ring shank nails
(3), equally spaced, staggered center rows
TA, APP-TA
AA, SBS TA, APP-TA
Exterior Research and Design, U.C. d/b/a Trinity) ERD•
Certificate of Authorization i#9503
Prepared by: Robert Nieminen, PE-59166
e EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Evaluation Report P9290.02.08-R20 for FL3654-R22
Revision 20: 09/12/2017
Appendix 1, Page 17 of 58
in