Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERATOR
16/20/22 kW INCLUDES: • True PowerT" Electrical Technology • Two Line LCD Multilingual Digital Evolution"°" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details SCANNEDBY GENERAC® GUARDIAN° SERIES J :� Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz ST l:W�]��lililJ.TfY • Electronic Governor P11AN1 rBU1Wj • System Status & Maintenance Interval,LED l Indicators 8 air • Sound Attenuated Enclosure ELIE • Flexible Fuel Line Connector DATE: r/1 y • Direct -To -Dirt Composite Mounting IMB:_. • Natural Gas or LP Gas Operation DATE.., • 5 Year Limited Warranty MECHI:.DATE: • Capability to be installed within 18" (457 mm) of a building* FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and ,extreme operating conditions. O TRUE POWERT' ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. QUIEf-TEST - Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides palls and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are .✓: PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENE R AC ryal7*ass ,yF�4�, '► _ !G®p� *©� Mobil ' PROMISE ,(� Link StoMEP GP `L'IppA�` � • auflt In the USA using domestic and foreign parts. 16/20/22 kW GENERAC® features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance; less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allo s for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic • NEMA 3R • Remote mounting Evolution'" Controls • Auto/Manual/Off illuminated buttons • Two-line LCD multilingual display • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Programmable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Unit • SAE weather protective enclosure • Enclosed critical grade muffler • Small, compact, attractive r i 4 1. :.;:.;u Transfers your vital electrical loads to the energized source of power. Can be installed inside or outside for maximum flexibility. Mounts near your existing distribution panel for simple, I w,cost installation. Selects the operating mode and provides easy, at=a-glance'§tatus indication in any condition. Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. Smooth, weather -resistant user interface for programming*arid operations. Constantly monitors utility voltage, setpoints 65% dropodt, •866Z pick-up, of standard voltage. Constantly monitors generator voltage to ensure the.cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Ensures engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown' setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only , hen needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation\ps close as 18" away from a building. Installation System • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connecte\to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking\of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW GENERAC specifications Generator Model G007035-0, G007036-0, G007038-0, G007039.0 G007042-1, G007043-1 G007037-0 (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,000 Watts' 19,500 i Rated Voltage 240 240 240 Rated Maximum Continuous Load Current-240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less than'5% Less than 5% Less than 5%� Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Rated AC Frequency 60 Hz 60 Hz 6011z Power Factor 1.0 1.0 1.0 Battery Requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight (Ib/kg) 406/186 448/203 466/211 Dimensions (L x W x H) in/mm 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A) at 23 it (7 m) with generator operating at normal load'" 66 _ 66 67 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Black Aluminum w/ Cast Iron Sleeve Valve Arrangement r Overhead Valve Overhead Valve Over Valve ,Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1� Starter 12 Vdc 12 Vdc 12 Vdc Oit Capacity Including Filter Approx.1.9 gl/1.8 L Approx. l.9 gt/1:8 L Approx.1.9 qV 8 L Operating rpm 3,600 3,600 3,600 Natural Gas W/hr (ma/hr) 1/2 Load 218 (6.17) 204 (5.78) 228 (6.46) Full Load 309 (8.75) 301 (8.52) 327 (9.26). (Liquid Propane ft3/hr(gal/hr) [I/hr] f 1/2 Load 91.6 (2.52) [9.531 86 (2.37) 18.991 92 (2.53) [9.57] Full Load 106.8 (2.94) [11911 129.E (3.56) [13_48] 142 (3.90) [1497] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel ihlet at all load ranges - 3.5-7° water column (7-13 mm mercury) for natural gas,10-121, water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or 0/hr x 1000 (NG). For Megajoule content, multiply ma/hr x 93.15 (LP) or ma/hr x 37.26 (NG) Controls 2-1-ine Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons -.Auto Automatic Start on Utility failure. 7 day exerciser. Manual Start with starter control, unit stays on. II utility falls, transfer to load takes place. Off Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Bating definitions -Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance With BS5514. IS03046 and DIN6271). ' Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 T) above 16 T (60 °Fl. 16/20/22 kW Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanic ily-held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pale, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum c • Main contacts are silver plated or silv0 • NEMA/UL 3R aluminum outdoor enclo mounting flexibility. • Multi listed for use with 1" standard, to Siemens, Murray, Eaton and Square D live install. Dimensions alloy to resist welding and sticking. ire allows for indoor or outdoor m, GFCI and AFCI breakers from the most flexible and cost effec- Height Width H1 H2 Wi W2 Depth in 26.75 30.1 10.5 13.5 16.91 mm 679.4 764.3 266.7 343.0 1V5.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 1 2/0-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed whe used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2-pale, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. 1 Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 GENERAC® switch options Made[ G007036-0 (16kW) No. of Pales 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120/240,19 Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80% 65% Return to Utility* approx.15 sec Exercises bi-weekly for 5 minutes*t Standard UL Listed Standard Total Circuits Available 24 Tandem Breaker Capabilities 8 tandems Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 *Function of Evolution Controller Exercise can be set to weekly or monthly DEPTH Model G007037-0 (16 kW)/6007039-0 (20 kW)/ G007043.0 (22 kW) No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80°% 65% Return to Utility* approx,13 sec Exercises bi-weekly for 5 minutes* Standard UL Listed Standard Enclosure Type NEMA/UL 311 Circuit Breaker Protected '22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly DEPTH 16/20/22 kW GENERAC available accessories Model # Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- G007005-0 Wi-Fi LP Fuel Level Monitor itoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link'" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & PCs Dimensions shown are approximate. Peter to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT SIDE VIEW 148Z IM FRONT VIEW Model UPC 0007035-0 696471070354 0007036-0 696471070361 0007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENE RAC® . Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 62017 Generac Power systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No.10000000194-F 5/3117 GENEIC° ACCESSORIES Model G006873.0 a Ous DESCRIPTION — _ �� `_ .�_ Usf Generac's Smart Power Management System is designed to optlmize the performance of a standby generator. The system can consist of up to 8Individual Small Management Modules (SMM), Unlike other load aware and operate autonomously. nag maement systems that depend on another control device, the SIAM modules are actually sell - Frequency Frequency is the true measure of generator anglne performance and does not need to factor in Increased ambient temperatures, elevation changes or generator Nei type, The modules monitor the frequency (147) of the power being produced by Generao's standby generators and It It falls below a certain threshold, the module will automatically follow generatorgenerator Is not overloaded. The modules can be set to a load priority between 1-8 or be set In a IOck out only modo for loads Mal just Simply d0 not need to run in an outage, therefore reducing the necessary size of the generator for a more cost e110b,'1 a soldtlon. 3MM SPECIFICATIONS Power Supply Source ..................... SupportedVolteges............................................................................................................................................................................................ Contaefor Coll voltage..................................................................................................... 240 VAC {Bom Line Input) CoilVA larush...........................................................................,.,....,............................_...............:........................................................................240 VAC CoilVA sealed........................:..........................................................................................................................................................................................................240 VAC poles................................................................................................................................................................... 3t1 ResISllveAmps....................................................................................................... ............................................. I...... .............w........................,..................................9.5 F/L1nd�totiveAmps ....................... ...........,.......,.................................................................................,,.......................................................... .........,......,...60 LockedRotor Amps................................................................................................................................................................................................._................................... ........................... t11.50.................................................................................................................. .................................................................,....,...24D�a 290Y EnclosureRating................................................................ ..yes ............... .................... .................................................................. NEMAsR Site Selection and Preparation A Site Selection and Preparation Site Selection O!; 5 ft (1.52 m) O 5 It (1,52 m) 1 1 r ®� 3 ft (0.91 3 � m) A 4'(o.sz m) • A 1 / 1 l�fgrt�e 3-�. Insgafa�iorl C12araFtC�s g0verheadolearance DescriptionCommenis generator I — nd end oleamanee Minimum clear distances cannot Include shrubs, bushes, or fres. learance 9s In (4S.7 r--) r, NrArnuM Gleamyca per NFAAtesGng, tabefing, and listing, unless state or wow codes dictate othelwlse. s and openings NO operable windaws, doors, or openings In the wall are permitted within 5 ti (im m) from any point of the generator. Wall One -hour fire rated walls allow closer placement of the generator set, Confirm before instalfalton, ble fence Removable fence pansis for ss,vichV cannotbe placed less Phan3 ft (0,91 m) to front efthe generator,d olearance 6 ft (7,52 m) minimum dlsfanoc-Tom any strucfure, overhang, or projections from the wall, DO NOT instal under wooden decks or si! uctures unless this distance is mainlalrteti, installation Guidelines For 60 Hz Air -Cooled Generators 11 Site Selection and Preparation generator enclosure would not poN any ignition risk to nearby combustibles or structures, with or without Tire service personnel response, ��mt'art�o` A ?Orr. & iW CiiAFL c�taa sYsr;?as, t� ►'Wre 3 2 S+UUMWest Research Instgtjts 119ar. ng Based on this testing and the requirements of NFRA 37, Sao 4.1.4, the guidelines for Installation of the generators listed above are changed to 18 in (457 mm) from the back side of the generator to a statlonary wall or building (C). For adequate maintenance and air;iow clearance, the area above the generator should be at lead 5 ft (1,52 m) with a minimum of 3 ; f (0.91 m) at the front and ends Of the enclosure. This includes trees, shrubs, and bushes. Vegetation not In compliance with These clearance parameters could obstruct air flow ad dition, ddition; exhaust fumes from the generator could in a pion, growth. See ;=r,_,�.� ��;; and the installation dra within the owner's manual for details. wing Automatic star' -up. Disconnect utilly power and render unit Inoperable before workingon unit . Failure to do so will result in death or serious injury, (0019191)' Asphyxiation, Running engines produce carbon monoxidof e, a colorless, odorless, avoideed willlUS resuls. t in death or serious injury. (c�00103) NOT6, If the generator 1s not set to OFF, It can crank and start as soon as the battery cables are connected. If the utlllty power supply is not turned off, sparking can occur at the battery posts and cause an explosion. Site Preparation ° Locate the mounting area as close as p08slble t transfer the switch and fuel supply. Leave adequate room arourid the area for service access (check local code), and place high enougl, to keep rising water from reaching the generator. ° Ghoose an open space that will provide adequate and unobstructed airflow, ° Place the unit so air ventswon't become clogged with leaves: grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air Intakes (see ° Select the type of base, such as —but not limited to —compacted soil, gravel, or concrete, as desired or as required by local laws or codes, Verlry your Iota! requirements before selecting. rtflateriaf Sufficlent for Level installation ° Prepare a rectangular area approximately 5 In (127 mm) deep (A) and approximately 6 In (152 MM) longer and wider (8) than the footprint of the generatorverify that the surface where the generator will be mounted Is compacted, leveled, and will not erode over time. A concrete pad can be Poured if desired -or required. It� Y 4�-'��w�✓ �•••�"' � ~'tea plgur6 3-3, Compacted Soil or Gravel pant NOTE: If a concrete pad Is required, follow all applicable federal, state, or local codes. lnstallafion Qulr�elines i;a 60 Ll j m r a A r-Gooiep venerators 40