EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
'26 GA. SV-CRIMP PANEL'
I
FLORIDA BUILIDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.4-R3
ROOFING
(METAL ROOFING
I
I
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville. KY 40202
Telephone: (502) 855-4300
Fax: (502)855-4290
I
i
IPrepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (918) 493-3568
This report consists of
Evaluation Report (3 Pages including cover) 0till Mire,
Installation Details (1 Page) 640: ° SOCKAk/�°�,,6
Load Span Table (1 Page) F o
No 62240
pro. �OF '�'• STATE e
Report No. C2182-4 o O ••. ,� P : \=�a
Date: 9.9.17 �`s��' O R
..c. 2ot-7
FL 14645.4-R3
C2182-4
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name:
5V-Crimp
Panel Description:
24" wide coverage with (5) 1/2" high ribs
I
Materials:
Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description:
Min. 7/16" thick IOSB or min. 15/32" thick plywood or min. V thick
wood plank (min SG of 0.42) for new and existing constructions.
Designed by others and installed as per FBC 2017.
Deck Attachment:
8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum)
in the plywood field and edges. Designed as per FBC 2017.
Underlayment:
Minimum underpayment as per FBC 2017 Section 1507.4.5.1.
Slope:
1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure:
30.0 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2)
172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & U1,1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 11507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. e design pr(,-mare-for-reduced-fastener-spacing-may-be - --
direct(; � `v ASTM E108/UL790 report from an;dited laboratory,
for fir&i, I. ngs of this product.
Supporting Documents: UL580 & 1897 Test Reports
PRI Construction Materials Technologies
MSMC-0 17-02-0 1, Reporting Date 9/20/13
FL 14645.4 R3
C2182-4
9.9.17
Page 3 of 3
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This evaluation
report is not applicable in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
5V-CRIMP
SEE DETAIL 2
PANEL
-7(</--SEE DETAIL 1
FASTENER AT PANEL FLAT
REQUIRED FOR PANEL
ENDS ONLY.
v
MINIMUM ATTACHMENT:
j 8d x 2.5" LONG RING SHANK NAIL
I UNDERLAYMENT SHALL BE INSTALLED OR #8 x 2" LONG WOOD SCREWS
AS PER MANUFACTURERS INSTALLATION SPACED ® 6" O.C. IN THE FIELD
GUIDELINES & AT EDGES
MIN. 2X- WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" D.C.
TYPICAL PANEL INSTALLATION X—SECTION
09-16 OR P10-14 WOODSCREWS
WITH -SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
UNDERLAYMENT J
DETAIL 1
#9-16 OR J10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
UNDERLAYMENT
IM
DETAIL 2
5V-CRIMP
MIN 26 GA.
OSB 7/16" THICK (MIN.) OR
PLYWOOD 15/32' THICK (MIN.)
5V-CRIMP
MIN 26 GA.
OSB 7/16" THICK (MIN.) OR
PLYWOOD 15/32 THICK (MIN.)
PANEL FASTENER PER UPLIFT
LOAD TABLE
N e NOT
1 ARCHITECTURAL ROOF
CODEPANEL (FBHAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA 2. ROOF PANELS SHALL BE MIN, 26 GA. (t = 0.019"). EFFECTIVE COVERING
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. T
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOA
ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWII
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CDDE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.