EVALUATION REPORT OF
DWI,-,r
UNION CORRUGATING COMPANY
StPUP10 OBQ�rr`•y
`29 GA. MASTERRIB PANEL'
OVER WOOD SUPPORTS
FLORIDA BUILDINGCODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.4-R4
STRUCTURAL COMPONENTS
ROOF DECK
Prepared For:
Union Corrugating Company
701 S. King St.
Fayetteville, NC 28301
Telephone (910) 483-0479
Fax: - (9,10) 483-1091
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page) ,0%111o111ea®1
Load'Span Table (1 Page) goo®SpGKA���,�°�o,�
SN S '•. �ed, .
4
• No 62240 '•.�
0r :/W��
o • � • ay:
p
T6
4
20.2G %—I
Report No. C2172-4
Date: 8.20.2017
FL 9555.4-R4
C2172-4
8.20.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: MasterRib Panel
Panel Description: 36" wide coverage with 3/4" high ribs at 9" o.c.
Materials: Minimum 29 ga., 8,0 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Support Description: Nom. 2" x 2" (mini) SPF, SYP or DF lumber. (Must be designed by
others)
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Pressure: +27.1 and -36.2 psf @ support spacing of 48" o.c.
(Based on testing) (@ 3 span condition with FS = 2.0)
Panel Attachment: #9-15 or #10-14 x 1.5" long wood screws with washers
At panel ends @ 3.5"-5.5"-3.5" o.c. across panel width
At intermediate @ 9" o.c. across panel width
Sidelap Attachment: '/a"-14 x 7/8" long SIDS with washer @ 24" o.c.
Test Standards: Panel assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Test Equivalency: The test procedure - in ASTM E1592-01 comply with test procedure
prescribed in ASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
prescribed in FM 4470 (2012).
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design pressure for reduced support spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union Corrugating load span table. This product
is not approved for use in the High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FL 9555.4-R4
C2172-4
8.20.2017
Page 3 of 3
FBC 2017 Section 1505 and current approved roofing materials
directory for fire ratings of this product.
Supporting Documents: ASTM E1592 Test: Report
ENCON Technology Inc.
C1514-1 (Test #2 & 3), Reporting Date 9/8/07
FM 4470 Test Report
ENCON Technology Inc.
C1583-2, Reporting Date 7/24/08
INTERIOR SUPPORTS
NOM. 2" X 2" (MIN)
LUMBER (DESIGNED
BY OTHERS)
END SUPPORTS
NOM. 2" X 2" (MIS
LUMBER (DESIGNED
BY OTHERS)
MASTERRIB
PANEL
PANEL FASTENER SEE PANEL SIDELAP SIDELAP FASTENER
® 9' O.C. DETAIL_ ® 24" O.C.
-9" O.C. MASTERRIB
PANEL
PANEL FASTENER ® SIDELAP FASTENER
3.5 5.5"-3.5" O.C. ® 24" O.C.
i O.C. /— MASTERRIB
PANEL
TYPICAL PANEL INSTALLATION X-SECTION
PANEL FASTENER
® 9" O.C.
NOM. 2" X 2" (MIN)—/
LUMBER (DESIGNED
BY OTHERS)
SIDELAP FASTENER MASTERRIB
1/4"-14 SDS WITH PANEL
WASHER @ 24" O.C. PANEL FASTENER
#9-15 OR #10-14 x 1.5" LON
SDS WITH WASHER
NOM. 2" X 2" (MIN)
LUMBER (DESIGNED
PANEL SIDELAP BY OTHERS)
SIDELAP FASTENER PANEL FASTENER
® 24" O.C. 3.5"-5.5"-3.5" O.C.
MAX 48" O.C. v
(SEE LOAD SPAN TABLE FOR
ALLOWABLE LOADS AND SPANS)
SECTION VIEW
GENERAL NOTES:
1. ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA
G BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE 29 GA. (t = 0.013"). EFFECTIVE COVERING WIDTH
OF PANEL = 36".
3. ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS
DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE _DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE DESIGN LOADS.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
7. PANELS MAY SPAN BETWEEN EAVE TO RIDGE SUPPORTS OR RAKE TO RAKE
SUPPORTS.
d
U LO
Z ofNrn
Q' CQF7 U~l U N
a ZZM
N O YJ�
p U ui�l 0
0
Z rn
3 z oQ-
o Go
zd
a Li
v
o a
m O U m
2 LIr i
m a s m
V) o ox
4� z
U �Zm
`F to
N - m
SHEEP NO.
1 OF
F
UNION CORRUGATING COMPANY
MasterRib Roof Panel
36" wide, 29 ga. (min) Steel Panel over,Wood Supports
Span
Condition
Loading.
Type
Allowable Load (psf)
Support .Spacing (ft)
1.50
1.75
2.60
2.25
1 2:50
2.75
3.00
3.50
4.00
Two Span
Gravity
106.4
91.2
79.8
70.9
63.9
58.0.
53.2
45.6
34.7
Uplift
84.9
72:8
63.7
56.6
51.0
46.3
42.5
36.4
29.0
Three Span
Gravity
120.9
103.7
90.7
80.6
72.6
66.0
60.5
40.5
27.1
Uplift
96.5
82.7
72.4
64.4
57.9
- 52.7
483
41.4
36.2
Four or More
Gravity
116.4
99.8
87:3
77.6
69.8
63.5
58.2
43:0
28.8
Spans
Uplift
92.9
79.6
6917
61.9
55.7
50.7
46.5
39.8
33.8
Notes:
I. Allowable load for each condition is the smallest load calculated based on fastener capacity, panel strength and
and deflection limit of L/180. Allowable loads are calculated for minimum 29 ga. panel.
2. The wind load is taken as 0.7 times the "component and cladding" loads for the purpose of determining deflection limit.
3. The panel allowable properties are determined from full scale ASTM E 1592 tests at 4' 0 span
4. The panel fasteners are #9-16 or 10-.14 x 1-1/2" long wood screws. with washers. Fastener spacing across panel width
is 9.0" o.c. in the interior supports and 3.5"-5.5"-3.5" o.c. at panel ends.
5. Sidelap fasteners are 1/4"-14 x 7/8" long self drilling screws with washers at 24"o.c.
6. Wood supports are minimum 2" x 2" lumber. All supports must be designed to resist all loads imposed on the panel.
7. Minimum bearing width of support is 1.5
8. The panels may span from eave to ridge or rake to rake.
9. Panels must be installed as per Evaluation. Report FL 9555.4 and Union current installation procedure.
1216 N Lansing Ave, Suite C
Tulsa, OK 74106
918 492 5992
o4®1Ef61eB�60!
4JT,.° No 62240
q
�-o°; gTATE OF _
d
N ew
fi
$ . 2-0 . i201"7
Bala Sockalingam, Ph.D., P.E.
PE 62240