Loading...
HomeMy WebLinkAboutEVALUATION REPORTN 6LANNED BY� CREEK Certificate of Authorization No.inb 2gh Dr 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017) Manufacturer: ATLAS ROOFING CORPORATION Issued September30, 2017 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770)612-6267 www.atiasroofin-g.com Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 1523.1.1 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a PRODUCT DESCRIPTION Fabral All Purpose High -Temp ASTM D 1970 SBS modified, self -adhering underlayment with a fiberglass mat Underlayment reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirem,'ents. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the underlayment shall be limited to a maximum 30 days. Underlayment may be self -adhered to primed or unprimed plywood substrates in the non-HVHZ. Mechanically fastened roof coverings as prescribed in FBC Table 1507.1.1 shall be permitted. ,:5rrfzU-4D-qL ST. LUCIE COUNTY BUILDING DIISION ' REVIEWED FOR COMPLIANCFi� �>— �5 REVIE D B DATE �� PLANS AND P MIT MUST BE KEP ON JOB SITE OR NO INSPECTION(S) WILL BE MADE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ATL14001.46 FL17322-R4 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ,,ONcEAOONTRA TOR OR RECORDPAS TENERS OR HMEMJ FILE COPY ARE THE RESPONSIBILITY OF THE I [;'11�24` ATLAS ROOFING CORPORATION CREEKRoofing Underlayments H TECHNICAL, SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Roof slope limitations shall be in accordance with FBC requirements. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Products described within this report may be used as described in other current FBC product approval documents. 5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents. 6) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 6'h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 5Y fR �f/,��,,i No 74021 = yt STATE OF 4U� A,4 O Zachary R. Priest, P.E. �i�s •' R � Florida Registration No. 74021 I'll/ A. � ��� Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. i CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. i Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL14001.413 FL17322-R4 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.