EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer: ATLAS ROOFING CORPORATION Issued September30, 2017
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770)612-6267
www.atiasroofin-g.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1 1523.1.1
Properties: Physical properties
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a
PRODUCT DESCRIPTION
Fabral All Purpose High -Temp ASTM D 1970 SBS modified, self -adhering underlayment with a fiberglass mat
Underlayment reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirem,'ents. Roof decks shall have no more than 1/8" gap at abutting
joints.
Exposure of the underlayment shall be limited to a maximum 30 days.
Underlayment may be self -adhered to primed or unprimed plywood substrates in the non-HVHZ.
Mechanically fastened roof coverings as prescribed in FBC Table 1507.1.1 shall be permitted.
,:5rrfzU-4D-qL
ST. LUCIE COUNTY BUILDING DIISION '
REVIEWED FOR COMPLIANCFi� �>—
�5
REVIE D B
DATE ��
PLANS AND P MIT MUST BE KEP ON JOB
SITE OR NO INSPECTION(S) WILL BE MADE
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
ATL14001.46 FL17322-R4 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
,,ONcEAOONTRA TOR OR RECORDPAS TENERS OR HMEMJ FILE COPY
ARE THE RESPONSIBILITY OF THE
I
[;'11�24`
ATLAS ROOFING CORPORATION
CREEKRoofing Underlayments
H TECHNICAL, SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Roof slope limitations shall be in accordance with FBC requirements.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Products described within this report may be used as described in other current FBC product approval
documents.
5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other
current FBC product approval documents.
6) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code, 6'h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
5Y fR �f/,��,,i
No 74021
= yt
STATE OF 4U�
A,4 O Zachary R. Priest, P.E.
�i�s •' R � Florida Registration No. 74021
I'll/ A. � ��� Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
i
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
i
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
ATL14001.413 FL17322-R4 Page 2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.