HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance SCANNED
Project Name: CIULLO SCREEN ROOM��_
Project Address: 5706 SUNSET BLVD
Permit #:
INSTRUCTIONS FOR USE:
Occupancy Type: R Construction Type: V
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.,
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS -USED: (complete'all that apply) '
1. DESIGN CODE: Florida in Code 2017 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed 1 Partially Enclosed Open
3. Risk Category: _ I X II III IV Exposure Category: _ B X C D
4. Design Wind Velocity 165 mph 128 ASD N/A LRFD End Zone Width: 5 ft
S. Mean Roof Height: 20. ft Roof Pitch: o.as :12 1 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 21.8 Zone 2: 21.8 Zone 3: 21.8 Zone 4: 37.9 Zone 5: 37.9 Garage: N/A
-34.7 -60.3 -89.2 -41.1 -50.7 N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF
Dock:. N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED
8. Were Shear Walls Considered For Structure?_Yes ' Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? -- Yes No't Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
4/9/2018
Signatu ,'Date, and Seal
SLCCDV form # 020-12`Revised 3/Ss/12 (JS)
-�OP;�
Paul Welch P.E. 29945 / 5115
Print Name Cert # & Co. Cert Auth.
Paul Welch Inc.
1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL
Company Name & Address
File �®py