HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance SCANNED Project Name: CIULLO SCREEN ROOM��_ Project Address: 5706 SUNSET BLVD Permit #: INSTRUCTIONS FOR USE: Occupancy Type: R Construction Type: V • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure., * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS -USED: (complete'all that apply) ' 1. DESIGN CODE: Florida in Code 2017 Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed 1 Partially Enclosed Open 3. Risk Category: _ I X II III IV Exposure Category: _ B X C D 4. Design Wind Velocity 165 mph 128 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 20. ft Roof Pitch: o.as :12 1 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 21.8 Zone 2: 21.8 Zone 3: 21.8 Zone 4: 37.9 Zone 5: 37.9 Garage: N/A -34.7 -60.3 -89.2 -41.1 -50.7 N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF Dock:. N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure?_Yes ' Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? -- Yes No't Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: 4/9/2018 Signatu ,'Date, and Seal SLCCDV form # 020-12`Revised 3/Ss/12 (JS) -�OP;� Paul Welch P.E. 29945 / 5115 Print Name Cert # & Co. Cert Auth. Paul Welch Inc. 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address File �®py