HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 5wA ED
FLORIDA ENERGY EFFICIENCYY 'Q 1` BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
Street: `�5�,. 0 0-�`Ikq
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1 1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
1111 2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sgft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
c.
R= ft2
Conditioned floor area below grade (ft2) 0
11. Duuctct s
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250 !
14. Hot water systems
8. Floor Types (1445.5 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
EF: 0.970
! a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
b. N/A iR= ft2
None
c. NIA R= ft2
i
15. Credits
Pstat
Total Proposed Modified
Glass/Floor Area: 0.098
Loads: 48.03
PASS
SS
. Total Baseline
Loads: 48.08
f1�7
I hereby certify that the plans and specifications covered by
Review of the plans and
0 -V%E STgT�
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
�j ii�' z- vs+
�O
with the Florida Energy Code.
N un,r'' ,;:;.•`��„
'
PREPAR BY: Y
Before construction is completed
r�
DATE: �' -
this building will be inspected for
0 -I�,� F X
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5�
with the Florida Energy Code.
OWNER/
BUILDING OFFICIAL:
q
DATE:`l
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than
7.00 ACH50 (R402.4.1.2).
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
I
FIF)RhA R4nF_9nl7
PROJECT
Title:
WYNNE THE GRAND CARL
Bedrooms: 2
Address Type:
Street Address
Building Type:
User.
Conditioned Area: 1446
Lot #
Owner Name:
.WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
#of Units:
,1
Worst;Case: Yes
PlatBook:
Builder Name:
WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office:
ST. LUCIE COUNTY
Cross; Ventilation: No
County:
St. Lucie
Jurisdiction:
ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
I Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site
97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
I FL, Fort Pierce FL_VERO_BEACH_MUNI ; 39 90
i
70 75 299
62 Low
I n�nvn
Number
Name
Area Volume
1
Entire House
1446
11568
SPACES
Number
Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
1
BEDROOM
301
2408
No
0
1
1
Yes
Yes
Yes
2
WIC.
63
504
No
0
1
No
Yes
Yes
3
M:BATH
56
448
No
0
1
Yes
Yes
Yes
4
KITCHEN
192
1536
Yes
0
1
No
Yes
Yes
5
BATH
45
360
No
0
1
Yes
Yes
Yes
6
BEDROOM 2
204
1632
No
0
1
1
Yes
Yes
Yes
7
ENTRY
55
440'
No
0
1
Yes
Yes
Yes
8
LAUNDRY
42
336
No
0
1
Yes
Yes
Yes
9
GREAT/DINING
488
3904
No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM
52 ft
0
301 ft2
----
0
1
0
_
2 Slab -On -Grade Edge Insulatio
WIC
1 ft
0
63 ft2
____
0
1
0
_
3 Slab-Qn-Grade Edge Insulatio
M. BATH
8 ft
0
56 ft2
____
0
1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN
1 ft
0
192 ft2
____
0
1
0
5 Slab-Qn-Grade Edge Insulatio
BATH
5 ft
0
45 ft2
----
0
1
0
_
6 Slab -On -Grade Edge Insulatio
BEDROOM 2
32.2 ft
0
203.5 ft2
-___
0
1
0
7 Slab -On -Grade Edge Insulatio
ENTRY
7 ft
0
55 ft2
____
0
1
0
File Copy
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -:Grade Edge Insulatio
9 Slab -On -Grade Edge Insulatio
LAUNDRY 6 ft 0
GREAT/DINING 146 ft 0
42 ft2
488 ft2
----
----
0
0
1 0
1 0
1
ROOF
V # Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt
Tested
Deck Pitch
Insul. (deg)
1 Gable or Shed
I
Metal
1524 ft2 240 ft2 Light
ATTIC
0.6
No 0.9
No
0 18.4
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
150 1446 ft2
N N
I
v�Ia.uvv
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
BEDROOM
30
Blown
301 ft2
0.1
Wood
2
Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented)
M. BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented)
KITCHEN
30
Blown
192 ft2
0.1
Wood
i5
Under Attic (Vented)
BATH
30
Blown
45 ft2
0.1
Wood
6
Urider Attic (Vented)
BEDROOM 2
30
Blown
204 ft2
0.1
Wood
j 7
Under Attic (Vented)
ENTRY
30
Blown
55 ft2
0.1
Wood
j 8
Under Attic (Vented)
LAUNDRY
30
Blown
42 ft2
0.1
Wood
I 9
Under Attic (Vented)
GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
-Adjacent
Space
Cavity
R_Va, le
Width
Et In
Et
Height
In
Area
Sheathing Framing
R-NIalue Ernrtinn
Solar
Ahqnr
Belo w
Grade
1 NE=>SW Exterior
Concrete Block - Ext InSfflEDROOM
4.1
10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior
Concrete Block - Ext InsiBEDROOM
4.1
28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior
Concrete Block - Ext InsiMEDROOM
4.1
14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior
Concrete Block - Ext InsulM. BATH
4.1
8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior
Concrete Block - Ext Insul BATH
4.1
5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior
Concrete Block - Ext InfiffDROOM 2
4.1
16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior
Concrete Block - Ext InEREDROOM 2
4.1
10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior
Concrete Block - Ext InOEDROOM 2
4.1
4
3 8
0
34.0 ft2
0
0
0.6
0 f'
9 SW=>NE Exterior
Concrete Block - Ext In�REDROOM 2
4.1
2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior
Concrete Block - Ext Insul ENTRY
4.1
6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior
Concrete Block - Ext Insul ENTRY
4.1
1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior
Concrete Block - Ext InsillAUNDRY
4.1
6
0 8
0
48.0 ft2
0
0
0.6
0
_ 13 NE=>SW Exterior
Concrete Block - Ext InsGREAT/DINI
4.1
26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior
Concrete Block - Ext InsGREAT/DINI
4.1
20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage
Frame - Wood KITCHEN
11
24
8
192.0 ft2
0.23
0.6
0
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
MORM R405-2017
DOORS
# Ornt
Door Type
Space Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=NNW
Insulated
ENTRY None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation =>) changed to Worst Case.
Wall
Ornt ID Frame
Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW:7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
Yes 1 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
Yes 1 0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
I
Yes 1 0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
Yes 1 0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in
I
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
' y # Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
I
315ft2 24ft 8ft
11
I INFILTRATION
1 # Scope Method
I
SLA CFM 50 ELA EgLA ACH ACH 50
{ 1 Wholehouse Proposed ACH(50)
.000356 1349.6 74.09 139.34 .2598
7
HEATING SYSTEM
# System Type
Subtype Efficiency Capacity
Block
Ducts
I 1 Electric Heat Pump/
Split HSPF:8.5 34.8 kBtu/hr
1
sys#1
i
COOLING SYSTEM
# System Type
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
I
Split SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
i
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap Use SetPnt
Conservation
j 1 Electric
None
Garage 0.97 40 gal 60.9 gal 120 deg
None
I
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
4/4/2018 12:13 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
DORM R405-2017.
DUCTS
/
---- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
, Area
.Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
325 ftZ
Attic
:85 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan
Feb
Mar
[
] A r [
a
X Jun X Jul
X Au
f
X Se
[ ]
Oct
Nov
Dec
Heating Jan
�Xj
Feb
�X�
Xj Mar
[
]Apr [
JIM
May
Jun i Jul
Au4
Sep
[ ]
Oct
Nov
ki
X Dec
Ventin Jan
Feb
[X Mar
[X]
Apr [
May
[ Jun Jul
[ Aug
( Se
[X]
Oct
Nov
[ Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
ISchedule Type
1
2
3
4
5 6
7
8
9
10
11
12
i Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
- TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name:
WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street:
Permit Office:
ST. LUCIE COUNTY
City, State, Zip:
FT. PIERCE, FL, Permit Number:
Owner: `
WYNNE BUILDING CROP Jurisdiction:
ST. LUCIE COUNTY
Design Location:
FL, Fort Pierce
i
r COMPONENT
I
AIR BARRIEii CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
i
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling)/soffit shall be aligned with
Ceiling/attic
I
[ the insulation and any gaps in the air barrier shall be sealed.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
j
! Access openings, drop down stairs or knee wall doors to
i unconditioned attic spaces shall be sealed.
i
I The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
Walls
The junction of the top plate and the'top of exterior walls shall be
shall be insulated by completely filling the cavity with
`
sealed.
a material having a thermal resistance of R-3 per inch
`
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skyliglts
The space between window/doorjambs and framing, and
skylights and framing shall be sealed.
and doors
t Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
i
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
j Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
k
9 Shafts, penetratigns
E Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
i
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
I Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
i
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring •
e
Batt insulation shall be cut neatly to fit around wiring
{
and plumbing in exterior walls, or insulation that on
!
installation readily conforms to available space shall
l
extend ' "
k
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall s
tubs shall separate them from the showers and tubs.
I be insulated.
Electrical/phone box on' The air barrier shall be installed behind electrical or communication
exterior walls
; boxes or air -sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
d be sealed to the sub -floor or drywall.
Concealed
; When required to be sealed, concealed fire sprinklers shall only be
sprinklers j
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings
!
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
yFORM R405-2017 I
ENERGY PERF6RMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
cr
The lower the EnergyPerformance Index, the more efficient the home.
FT. PIERCE, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft2
2. Single family or multiple family
Single-family
b. Frame - Wood, Adjacent
R=11.0
192.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrobms
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ft2
6. Conditioned floor area (ft2)
1446
b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows- Description
Area
11. Ducts
R ft 2
a. U-Factor: Sgl, U=0.54
101.25 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
40.00 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
34.8 SEER:15.00
SHGC:
d. Gor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
SHGC:
a. Electric Heat Pump
34.8
HSPF:8.50
Area Weighted Average Overhang Depth:
3.832 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types
Insulation
Area
14. Hot water systems
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0
1445.50 ft2
a. Electric
EF: 0.97
b. N/A
R=
ft2
b. Conservation features
c. N/A
R=
ft2
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: ..-A CL
Address of New Hpme:)�r; _Z�` City/FL Zip:A<A-,-•'tiQ
Jnm
't8i
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. i For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commissions support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1