HomeMy WebLinkAboutENERGY EFFICIENCY CODEq SGANNEU
FORM R405-2017 s��;
-FLORIDA ENEI�Oy80I.0 " CY CODE FOR 13UILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
Street: ` lsk<' Q �
Permit Office: ST. LUCIE COUNTY
City, State, Zip: T. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sqft.)
Insulation Area
8 5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft 2
16. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
Electric
Cap: 40 gallons.)
8. Floor Types (1445.5 sqft.)a.
Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
i
Total Proposed Modified Loads: 48.03
Glass/Floor Area: 0.098
���S
Total Baseline
Loads: 48.08
I hereby certify that the plans and specifications covered by
Review of the plans and
S7,q?�
this calculation are in compliance withhe Florida Energy
specifications covered by this
o�TgE
Code.
calculation indicates compliance
with the Florida Energy Code.
ru,,,"%
PREPAEIDY
Before construction is completed
i DATE- '-' + i
this building will be inspected for
compliance with Section 553.908
(^ ;d
*' k
11
i I hereby certify that this building, as designed, is in compliance I j
Florida Statutes.
with the Florida Energy Code.
COD WV
I
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater tian 7.00 ACH50 (R402.4.1.2).
e Copy
I
• I
4/4/2018 12:13 PM. EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FnRM R40.5-2017
PROJECT
Tit;9: WYNNE THE GRAND CARL
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units: 'T
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY
Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
I FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLdCKS
Number Name Area Volume
I .
1 Entire House 1446 11568
I
SP CES
Number Name Area
Volume Kitchen) Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM 301
I
2408 No
0
1
1 Yes
Yes
Yes
2 WIC 63
504 No
0
1 No
Yes
Yes
i
3 M.BATH 56
448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192
1536 Yes
0
1 No
Yes
Yes
I 5 BATH 45
360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204
1632 No
0
1
1 Yes
Yes
Yes
7 El' 55
440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42
336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488
3904 No
0
1 Yes
Yes
Yes
�
FLOORS
1
i # Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
I
BEDROOM 52 ft I 0
301 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
i
WIC 1 ft i 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
I
M. BATH 8 ft I 0
56 ft2
----
0 1
0
i
4Slab-On-Grade Edge Insulatio
+
KITCHEN 1 ft 0
I
192 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft I 0
45 ft2
----
0 1
0
I 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft l 0
I
203.5 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft i 0
55 ft2
----
0 1
0
1
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes I017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# Floor.Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
• 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab-Qn-Grade Edge Insulatio GREAT/DINING 46 ft
0
488 ft2
----
0
1
0
ROOF
/ Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
77
IRCC
# Type Ventilation
Vent F atio (1 in)
Area
RBS
1 Full attic Vented
i
p50
1446 ft2
N
N
CEI ING
# Ceiling Type Space
R-V,,alue
Ins Type
Area
Framing Frac Truss Type
j 1 Under Attic (Vented) BEDROOM
36
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
I 4 Under Attic (Vented) KITCHEN
i
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
3I0
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
3I0
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
3I0
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing
Solar
Belo w
Space
nrnt To 181a" Type1
NE=>SW Exterior Concrete Block - Ext InsBEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
_ 2 SW=>NE Exterior Concrete Block - Ext InsfEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext Ins8EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
_ 4 SW=>NE Exterior Concrete Block - Ext InsulM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
_ 6 NE=>SW Exterior Concrete Block - Ext Ind3fDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext In9EDROOM 2
4.1I 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext In9EDROOM 2
4.1, 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InfiEDROOM 2
i
I
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
I
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsLILAUNDRY
4) 6
0 8
0
48.0 ft2
0
0
0.6
0
-13 NE=>SW Exterior Concrete Block - Ext InsOREAT/DINI
4.11 26
0 8
0
208.0 ft2
0
0
0.6
0
_ 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1'1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
I
8
192.0 ft2
0.23
0.6
0
414/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
I
FnRAA R4n,i-2n17-
DOOIRS
# Ornt
Door Type
Space
I Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
I None .39 3 1
6 8
20.6 ftz
WINDROWS
Orientation shown is the entered oriehtation => changed to Worst Case.
Wall
v # Ornt ID Frame
Panes
NFRC
I Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.54 0.25 N 32.9 ftz 1 ft 0 in 1 ft 4 in
0.54 0.25 N 6.9 ftZ 1 ft 0 in 1 ft 4 in
0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.54 0.25 N 37.5 ftz 1 ft 0 in 1 ft 4 in
0.55 0.25 N 40.0 ftz 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed 0all Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
`
INFILTRATION
I
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
i
HEATING SYSTEM
i
# System Type
Subtype
I Efficiency Capacity
Block
Ducts
i
1 Electric Heat Pump/
Split
I HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
I Efficiency Capacity Air Flow
SHR Block
Ducts
j 1 Central Unit/
Split
I SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF I Cap Use SetPnt
Conservation
j 1 Electric
I
None
Garage
0.97 I 40 gal 60.9 gal 120 deg
None
i
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
I ftZ
i
4/4/2018 12:13 PM EnergyGauge® USA - FlaResI2017 Section R405.4.1 Compliant Software Page 4 of 5
FnRnn R4n.r,-9nl7
j
DUG�S
---- Supply
----
---- Return ----
Leakage
Air
CFM 25
CFM25
HVAC #
Location
R-Value
Area
Location
Area
Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
325 ft2
Attic
85 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPER�TURES
Programable Thermostat: Y
Ceiling Fans:
Coo' [[ Jan
jj ]] Feb
[[ Mar
[
j Apr [
] Ma
[[X]] un [[X] Jul
Aug�Xj
Se
[ j
Oct
[[ ]]Nov
Dec
Heating [X Jan
[X] Feb
[Xj Mar
[
] Apr [
]May
j ]Iun j ] Jul
[ ] Au
rj
Sep
[ ]
Oct
[X] Nov
X Dec
Ventin [[ Jan
[[ ]] Feb
[[X Mar
[X]
A r [
] Ma
[[ ]] Uun (( j Jul
[ ] Au
Se
[X]
Oct
[[X]] Nov
Dec
j Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
I
I
i
I
i
4/4/2018 12:13 PM EnergyGauge® USA - RaReJ2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARMIER .AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 4102.4.1.1
.AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name:
WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street:
Permit Office:
ST. LUCIE COUNTY
City, State, Zip::
FT. PIERCE, FL, Permit Number:
Owner:
WYNNE BUILDING CROP Jurisdiction:
ST. LUCIE COUNTY
Design Location:
FL, Fort Pierce
i COMPONENT.
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
I requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall ld with
Ceiling/attic
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shaed.
shall be aligned with the air barrier.
Lbeea
Access openings, drop down stairs or knee wall
iunconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall e sealed.
Cavities within corners and headers of frame walls
i
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
ing, and
The space between window/door jambs and framing,
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier. I
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
I
t
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints ;taped.
shall be permanently attached to the crawlspace walls.
i Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
i
exterior or unconditioned space shall be sealed.
fBatts
in narrow cavities shall be cut to fit, or narrow
i Narrow cavities
cavities shall be filled by insulation that on
I
installation readily conforms to the available cavity
a
spaces.
Garage separation
j Air sealing shall be provided between the garage and, conditioned spades.
!�
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall. I
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
I
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
i
4
extend behind pi1j= and wiring.
i Shower/tub
EEI The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
k on exterior wall
C tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box on The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building
Thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers p sealed in a manner that is recommended bylthe manufacturer.
i Caulking or other adhesive sealants shall not be used to fill voids
between fire .� i�er cover elates and walls) or ceilin's.
a. In addition, inspection of log walls shall be in accordance with the 'rovisions of ]CC-400.
4/4/2018 12:13 PM EnergyGaugeO USA - FlaRes20 7 FBC 6th Edition (2017) Compliant Software Page 1 of 1
f
r
�
FORM R405-201.7
-
ENERGY
PERFORMANCE LEVEL (EPL)
'
DISPLAY CARD
ESTIMATED ENERGY PER'PORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
I
FT. PIERCE, FL,
1.
New construction or existing
New (From Plans) 9. Wall Types Insulation
Area
2.
Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior R=4.1
1250.00 ft2
b. Frame - Wood, Adjacent R=11.0
192.00 ft2
3.
Number of units, if multiple family
1 c. NIA R=
ft2
4.
Number of Bedrooms..
2 d. N/A R=
ft2
10. Ceiling Types Insulation
Area
5.
Is this a worst case?
Yes a. Under Attic (Vented) R=30.0
1446.00 ft2
6.
Conditioned floor area (ft2)
1446 b. N/A R=
ft2
c. NIA R=
ft22
7.
Windows- Description
Area
11. Ducts
R ft
a. U-Factor: Sgl, U=0.54
101.25 ft2 a. Sup: Attic, Ret: Attic, AH: Attic
6 325
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
40.00 ft2
SHGC: SHGC=0.25
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump 34.8
HSPF:8.50
Area Weighted Average Overhang Depth:
3.832 ft.
Area Weighted Average SHGC:
0.250
8.
Floor Types Insulation
Area 14. Hot water systems
Cap:
40 gallons
a. Electric
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2EF:
0.97
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Effi
Construction through the above energy saving features which w
in this home before final inspection. Otherwise, a new EPL Disf
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Dncy Code for Building
be installed (or exceeded)
iy Card will be completed
e:
City/FL Zipr;��`,
WE
*Note: This is not a Building Energy Rating. If your Index Is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 !- Section R405.4.1 Compliant Software Page 1 of 1