Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 I F,ILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: MORAN RESIDENCE Builder Name: Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce I County: St. Lucie (Florida Climate Zone 2) ` 1. New construction or existing New (From Plans) 9. Wall Types (1941.8 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1941.80 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst crise? No 10. Ceiling Types (845.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 845.00 ft2 6. Conditioned floor area above grade (ft2) 1309 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(351.7 sgft.) Description Area a. U-Factor. Dbl, U=0.65 275.67 ft2- SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 64.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 22.0 SEER:20.00 c. U-Factor. Dbl, U=0.60 12.00 ft2 b. Central Unit 22.0 SEER:20.00 SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a: Electric Heat. Pump 22.0 'HSPF:9.80 SHGC: b. Electric HeatPump 22:0 HSPF:9.80 Area Weighted Average Overhang Depth: 2.074 ft. Area Weighted Average SHGC: 0.259 I 14. Hot water systems 8. Floor Types (1309.2 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 813.00 ft2 b. Conservation features EF: 0.950 b. Floor Over Other Space R=0.0 496.20 ft2 None c. NIA R= fit2 15. Credits Pstat Total Proposed. Modified Loads: 45.27 Glass/Floor Area: 0.269 �g PASS Total Baseline Loads: 57.62 I:. i I .hereby certify that the plans and specifications covered by Review of the plans and - SE ST,g7, this calculation are in compliance with the Florlda' Energ� specifications. covered by this Code. calculation calculation indicates compliance El ���• with the Florida Energy'Code. ti rnu,Q. =: -� PREP A D Y': , Before construction is completed (31 DATE. i this building will be inspected for compliance with Section 553.908oly h 1 hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida EnergyA A de. Q�.Y,^! CCiIi�t OWN N'T. I BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification by the air. handler unit manufacturer that the air handler enclosure qualifies; .as certified factoiysealed in accordance with R4031 3.2.1. - Compliance 'requires an Air Barrier and Insulation Checklist in accordance.with R402.4.1.1 and this project requires an envelope leakage test report with envelope. leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/1/2018 1:03 PM EnergyGauge® USA Section R405.4.1 Compliant Software I Page 1 of 6 FORM R405-20 T 7Nt'U.1 M1U1V11VJ#kMT tfl'IG�rt\LIJ 1. r[�i-.vR � PROJECT Title: MORAN RESIDENCE Bedrooms: I 2 Address Type: Street Address Building Type: User Conditioned Area: 1309 .Lot # Owner Name: Total Stories:1 2 Block/SubdMsion: # of Units: 1 Worst Case: I No PlatBook: Builder Name: Rotate Angl9: 0 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp `int Design Temp Heating Design Daily Temp Design Location TKY.Site I 97.5 % 2.5 % Winter .Summer Degree Days Moisture Range FL, Fort Pierce FL VERO 13EACH_MUNI I 39 90 70 75 299 62 Low BLOCKS Number Name Arrea Volume 1 UNIT #2 496 l 4662.4 2 UNIT#1 813 1327L SPACES Number Name Area Volume 1 Kitchen Occupants Bedrooms ' •. Infil ID Finished Cooled Heated 1 BATH 72 676.8 I No 0 1 Yes Yes Yes 2 WIC 48 451.2 I No 0 1 Yes Yes Yes 3 BEDROOM 214, 2011.6 I No 0 1 1 Yes Yes Yes 4 HALL 32 300.8 No 0 1 No Yes Yes 5 MTCHEN/LIVING 447' i 9834 Yes 4 1 Yes Yes Yes 6 OFFICE 17g 1682.6 No 0 1 Yes Yes Yes 7 WIC 3 35 329 No 0 1 Yes Yes Yes 8 LAUNDRY 35 329 No 0 1 Yes Yes Yes 9 13EDROOM 2 122 1146.8 No 2 1 1 Yes Yes Yes 10 WIC 2 40 376 No 0 1 Yes Yes Yes 11 BATH 2 40 376 No 0 1 Yes Yes Yes 12 HALLWAY 45 423 No 0 1 Yes Yes Yes FLpOR$ # Floor Type Space Perimeter Perimeter'R-Value Area Joist R-Value Tile Wood .Carpet 1 Slab -On -Grade Edge Insulatio BATH E ft 0 72 ft2 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 16 ft 0 48 ft2 0 1 0 i 3 Slab -On -Grade Edge Insulatio BEDROOM 27 ft 0 I 214 ft2 __ 0 1 0 4 Slab -On -Grade Edge Insulatio i HALL i ft 0 I 32 ft2 M 0 1 0 1 10/1/2018 1:03 PM EnergyGauge� USA Section R405.4.1 Compliant Software Page 2 of 6 �nann ann�_�n�7 INIDI IT All IMMARY G FP.KI IST, RFPORT FLOORS Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio KITCHEN/LIVING 30 ft l 0 447 ft2 0 1 0 6 Floor Over Other Space OFFICE ­ I — 32 ft2 0 0 0 1 7 Floor Over Other Space OFFICE ____ _� 147 ft2 0 0 1 0 8 Floor Over Other Space WIC 3 _M _� 31.8 ft2 0 0 1 0 9 Floor Over Other Space WIC 3 __ ____ 3.3 ft2 0 0 1 0 1017Ioor Over Other Space LAUNDRY ___ — 35 ft2 0 0 1 0 11Floor Over Other Space BEDROOM 2 111 ft2 0 0 1 0 12FI00r Over Other Space BEDROOM 2 _7 _ 11 ft2 • 0 0 1 0 13FIoor Over Other Space WIC 2 _ I �_ 8 ft2 0 0 1 0 1417I00r Over Other Space WIC 2 I _� 24 ft2 0 0 1 0 15FIoor Over Other Space WIC 2 �+ — 8 ft2 0 0 1 0 16Floor Over Other Space BATH 2 __ ____ 40 ft2 0 0 1 0 17FIoor Over Other Space HALLWAY i 6.3 ft2 0 0 1 0 18FIoor Over Other Space HALLWAY 24.8 ft2 0 0 1 0 19FIooc Over Other Space HALLWAY i ____ 12 ft2 0 0 1 0 20Floor Over Other Space HALLWAY i~ 2 ft2 0 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Eniitt :Deck Pitch # Type Mat6rials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip gomposition.shingles 891 ft2 C, ft2 Medium 0.85 No 0.9 No 0 18.4 ATTIC I RBS' IRCC, V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Vented 150 845 ft2 N N 10/1/2018 1:03 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 6 t • I r^nRA MA^r nn4-7 Iklr2l vr---I mill R.FP[)RT rVI\IVI I%"%Jv-LV 1J .... V . - -- - - --- ---- . CEILING I # Ceiling Type Space R-Wilue Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BATH 30 Blown 22 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown, 13 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 30 Blown 83 ft2 0.1 Wood 4 Under Attic (Vented) HALL 30 Blown 4 ftz 0.1 Wood 5 Under Attic (Vented) KITCHEN/LIVING 30 Blown 227 ft2 0.1 Wood 6 Under Attic (Vented) OFFICE 30 Blown 179 ftz 0.1 Wood 7 Under Attic (Vented) WIC 3 30 Blown cis ftz 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 35 ft2 0.1 Wood 9 Under Attic (Vented) BEDROOM 2 30 Blown 1.22 ft2 0.1 Wood 10 Under Attic (Vented) WIC 2 30 Blown 40 ftz 0.1 Wood 11 Under Attic (Vented) BATH 2 30 Blown djo ft2. 0.1 Wood 12 Under Attic (Vented) HALLWAY 30, Blown 45 ft2 0.9 Wood WALLS Ad'acent (Cavity Width Height Sheathing Framing Solar Below Space To Type R_v�n�A Et In Ft 1n -A<Aa B Value F�C+�� 1 SW Exterior Concrete Block,- Ext Insul BATH 1 4.1 6 0 9 5 56.5 ft2 0 0 0.6 0 _ 2 SW Exterior Concrete Block - Ext Insul WIC 4.1 6 0 9 5 56.5 ft2 0 0 0.6 0 _ 3 SW Exterior Concrete,Block - Ext Ins�EDROOM1 4.1 13 0 9 5 122.4 ftz 0 0 0.6 0 _ 4 NW Exterior Concrete Block •- Ext InMBEDROOM I 4.1 14 0 9 5 '131.8 ft2 0 0 0.6 0 _ 5 NE Exterior Concrete Block •- Ext InbUTCHEN/LI I 4.1 9 6 22 0 209.0 ft2 0 0 :0.6 0 _ 6 NW Exterior Concrete Block,- Ext ImbUTCHENILIV 4.1 24 10 22 0 646.3 ft2 0 0 0.6 0 _ 7 NE Exterior Concrete Block - Ext InsulOFFICE I 4.1 17 0 9 5 160.1 ftz 0 0 0.6 0 - 8 SE Exterior Concrete Block - Ext InsuIOFFICE 4.1 7 0 9 5 .65.9 ftz 0 0 0.6 0 _ 9 SW Exterior Concrete'Block - Ext InsuIOFFI.CE I 4.1 4 0 9 5 37.7 ft2 0 0 0.6 0 10 NW Exterior Concrete Black - Ext InsulOFFICE I 4.1 3 0 9 5 28.3 ft2 0 0 0.6 0 11 SE Exterior Concrete Block - Ext Insul WIC 3 4.1 6 0, 9 5 56.5 ftz . 0 0. 0.6 0 12 SE Exterior Concrete Block - Ext Insd1. AUNDRY 4.1 5 0 9 5 47.1 ftz 0 0 0.6 0 _ 13 SW Exterior Concrete Block - Ext lnREDROOM 2 4.1 11 0 9 5 103.E ft2 0 0 0.6 0 _ 14 NW Exterior Concrete Block- Ext InQtDROOM 2 4.1 12 0 9 6 113:0 ft2 0 0 0.6 0 `15 SW Exterior Concrete Block - Ext Insul WIC 2 4.1 5 0 9 5 47.1 ftz 0 0 0.6 0 _ 16 SE Exterior Concrete Block - Ext Insul BATH 2 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0 _ 17 SW Exterior Concrete Block - Ext Insul BATH'2 I 4.1 4 0 9 5 37.7 ft2 0 0 0.6 0 _ 18 SE Exterior Concrete Block - Ext IOsdIIALLWAY 4.1 3 0 9 5 .28.3 ft2 0 0 0:6 0 DOORS # Ornt Door, Type Space I Stor Storm U-Value Wdth FHeightln Area Ft In 1 NE Insulated KITCHEN/LIV None :35 3 8 24 ft2 10/1/2018 1:03 PM EnergyGauge� USA Section R405.4.1 Compliant Software Page 4 of 6 Fr1RM Rd111;_7r117 IMP.1 IT.SI:IMMORY nkpm I IRT REPORT, WINDOWS Orientation. shown is the.entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Fal or SHGC Imp Area Depth Separation Int Shade Screening 1 S%A1 1 Metal Low-E Double Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 2 SN! 3 Metal Low-E Double 'Yes 0.65 0.25 N 25.0 ft2 2 ft 0 in 1 ft 4 in None None 3 NV'1 4 Metal Low-E Double 'Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 4 NE: 5 Metal Low-E Double Yes 0.65 0.25 N 8.7 ft2 5 ft 0 in 1 ft 4 in None None 5 NVV 6 Metal Low-E Double Yes 0.65 0.25 N. 9.0 ft2 2 ft 0 in 1 ft 4 in None None 6 NVV 5 Metal Low-E Double Yes Oj65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 7 NVV 6 Metal Low-E Double Yes 0!65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 8 NVV 6 Metal Low-E Double Yes 0.65 0.25 N 60.0 ft2 2 ft 0 in 1 ft 4 in None None 9 NE 7 Metal Low-E Double Yes Q,65 0.25 N 60.0 ft2 2 ft 0 in 1 ft 4 in None None 10 NE 7 Metal Low-E Double Yes .0.65 0.3 N 64.0 12 2 ft 0 in 1 ft4 in None None 11 SVV 9 Metal Low-E Double Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in Nome None 12 NW 10 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 13 SVV 13 Metal Low-E Double Yes I0.6 0.25 N 12.0 ft2 , 2 ft 0 in 1 ft 4 in None None 14 NVV 14 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 15 SW 17 Metal Low-E Double Yes 0.65 0.25 1. N 12.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area C:ellmg Area Exposed (Nall Perimeter Avg.. WaII Height Exposed Wall Insulation 1 .4200 420 ft= I 20 ft 9.4 ft 4.1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ' ACH ACH 50 1 Wholehouse ProposedACH(50) .000609 ,2092:6 114.88 216.05 .6389, 7 HEATINr SYSTEM System Type Subtype ' Efficiency Capacity Block. Ducts 1 Dlectric Heat Pump/ Splif + HSPF:9.8 22 kBtulhr. 2 Ductless 2 Electric Heat Pump/. Split II HSPF:9.8 22 kBtu/hr 1 Ductless QOOLING SYSTEM # S5 Otem Type Subtype. Efficiency Capacity AVRow . SHR.. Block . Ducts 1 Central Unit/ Split, SEER: 20 22 kBtulhr cfrn 0.7' `2 Ductless 2 Central Unit/ Split i i SEER: 20 22 kBtulhr cf n 0.7 1 Ductless 10/1/2018 1:03 PM EnergyGauge® USA Secticn R405.4.1 Compliant Software Page 5 of 6 FORM R405 2017 INPUT SUMMARY CHEPKl IRT REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 i 50 gal 60.9 gal i 120 deg None SOLAR HOST WATER SYSTEM FFEC Collector Storage rt # Company Name Systerr' Model # Collector Model # Area Volume FEF None None I ft2 TEMPEF:ATURES i Programable Thermostat: Y Ce'ifing Fa s: Cooling Jan [[]Feb Heating [X7 Jan Feb ([��] Mar Lx] Mar [ C ] Apr ] Apr Jul f May I ] Jun Jul May [X] Jun ri (Xj Aug ] Aug) (Xj Sep Sepp f Oct Oct Nov Nov X Dec Dec EX] Ventin [[ ll Jan [ ]] Feb [[�X]] Mar [X] Apr [ Ma [ ] Jun Jul JJ Aug ] Se [ Oct LX Nov [ ]]] Dec Thermostat Schedule: HERS 2006 Reference I Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66. 68. 66 .68 66 66 68 68 68 68 68 68 68 68, 68 68 68 68 . 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BATH Defauft(8lbs/sq.ft. ft2 ft 0.3 WIC Default(81t)s/sq.ft. ft2 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8lbs/sq.ft. ft2 ft 0.3 KITCHENILIWNG Default(81t)s/sq.fL ft2 ft 0.3 OFFICE Default(8 lbs/sq.ft. ft2 ft 0.3 WIC 3 Default(81bs/sq.ft. ft2 ft 0.3 LAUNDRY' Default(8 Ibs/sq.ft. ft2 'ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft I ft 0.3 WIC 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Name: Rating Compant: 10/1/2018 1:03 PM EnergyGaugev USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECT IIOPJ COMPONENT CRITERIA TABLE 402.4.1..1 AIR BARRIER AND INSULATION INSPECTION COMPOIENT CRITERIA Project Name: MORAN RESIDENCE I Builder Name: Street: Permit Office: ST. L.UCIE COUNTY City,'State, Znp: ST. LUCIE COUNTY, FL, Permit Number. Y U Owner: Jurisdiction: w_ Design Location: FL, Fort Pierce v COMPONENT A.IR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air penmaeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic i The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier, shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic.spaces shall be sealed. Walls The junction of the foundation and sill plateshall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermalenvelope insulation for framed Walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between.window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the.airbamer. I Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall. be installed to (including insulation maintain permanent contact with the underside of above -garage, subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact medth the top side floors) of sheathing, or continuous insulation installed on the underside of.floor framing and. extends from the bottom. to: the top of all perimeter'floor framing members. Crawl space walls Exposed earth in unvenied crawl spaces shall be covered with Where provided instead of floor insulation, insulation a. Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility petnetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall'be filled, by 'insulation 'that`on I installation readily conforms to the aivailable cavity space;.. Garage separation Air sealing shall be provided between the garage and conditioned spa . Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermail envelope shall be air tight and IC rated. Plumbing and %miring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms toavailable space shall Shower/tub The -air barrier installed at exterior walls. adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from'the: showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed .behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope. shall be sealed to the sub -floor ordrywall.. j Concealed When required to be sealed, concealed+fire sprinklers shall only be sprinklers sealed in a rnanneri.hat is. recommended by the manufacturer. 'fill Caulking or other, adl esive.sealants shall not be used to voids tween fire 1 cover elates and walls or ciffinds- a. In aaaRlon, InSpection of log wails Shalf.oe In accoraance wan the provisions or 1W-4Uo., 10/1/20181:03 PM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE :INDEX* = 79 The lower the Energy Performance 1lndex, the more efficient the home. 1. New home or, addition 2. Single-family or multiple -family 3. No. of units (if multiple -family) 4. Number of bedrooms 5. Is this ai worst case? (yes/no) 6. Conditioned floor area (sq. ft.) 7. Windows, type and area a) U-factor.(weighted average) b) Solar Heat,Gain Coefficient (SZHGC) c) Area 8. Skylights a) U-factor.(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised {R-value) 10. Wall type and insulation: A. Exterior:. I. Wood frame (Insulation R value) 2. Ma:sonry (Insulation R-value) B. Adjacent: 1. Wood frame (insulation R-value) 2. Masonry (lnsulatiori R-value) 11. Ceiling type and insulation level a) Under.attio b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 12. Ducts, location & insulation level a) Supply ducts R b) Return ducts R_ c) AHU location 13. Cooling system: Capacity_ 44.6 a) Split system SEER_ 20.0 b) Single package SEER_ . c) Ground/water source SEER/COP_ d) Room unit/PTAC EER_ e) Other 14. Heating system: Capacity_ 44.0 ,a) Split system; heat pump HSPF_ 9.8 b) Single package heat pump HSPF_ c) Electric tesistance GOP d) Gas furnace; natural gas AFUE� e) Gas:fumace; LPG AFUE_ - f) Other 15, Water heating system a): Electric resistance EF 0.95 b) Gas fired; natural: gas EF_ c) Gas fired:, LPG EF_ d) Solar system with tank EF_ e).Dedicated heat pump with tank EF f) Heat recovery'unit , HeatRec%_ g) Other 16. HVAC.credits claimed. (Performance Method) a) Ceiling fans _ b) Cross ventilation _ No c) Whole house fan No d) Multizone cooling credit _ e) Multizone heating credit 0 Programmable thermostat _ Yes "Label required by Section R303A.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1, certify that this home has compiled, with the Florida Building. Code, Energy' Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspectlon.'Otherwise, a new EPL display card will be completed based on installed code compliiant features. 9b. gc: I 10A1. i _ 10A2. 14.1 16131,. 10B2. I i 11 a. 30.0 11b. I 11c. 11d. I No Builder Signature: Date: Address of New Home:. City/FL Zip:_ST. LUCIE COUNTY, FL 10/1/2018 1:03:06 PM Energygauge® USA 6.0.02 - Fla.Ftes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1