Loading...
HomeMy WebLinkAboutPLANREVIEW RECORD8GANNED p 2015INTERNATIONAL o RESIDENTIAL CODE® Plan Review # ��°Y 3 62 - � Date: to S�8 ' FOR ONE- AND TWO-F 1 ILY DWELLINGS valuation: PLAN REVIEW RECORD' Fee: JURISDICTION: I (c ty; County, Township, etc.) / BUILDING LOCATION: (Street address) . --,BUILDING DESCRIPTION: REVIEWED BY:°IF .Numerals indicated in parenthesis are applicable; code se s the 20151nteinafJonal Residential Code (IRCJ The plan" review accomplished as indicated,."' :. in this record is limited to those.code sections specif id fled herein. This recored references commonly applicable code sections with due regard for the amountandtype of detailed information whi i p" ly.fourid on construction documents for one- and two-family dwellings and townhouses: It doe`s, not reference -alb code provisions which may be;,apphoable to specific buildings. This record is designed to be used only by those who°are knowledgeable r and'capable;of exercising; competent judgment in evaluating construction documents for code compliance. - CORRECTIONS LIST No. (DESCRIPTION Code Section I I II I I I I I I I, i II Copyright,• ••e Council, Inc. Reproducfion by prohibited. ISBN 978-1-60983-611-5 JCC \\is the trademarkof •nal' Code Counoil,• is registered in the U.S. Patent and IIIIIIIIIIII III III III III Trademark• - • additional INTERNATIONALCODE.forms,- 9II781609II836115II INTERNATIONAL CODE COUNCIL'PHONE• - r1- m ON LIST (cont'd.) DESCRIPTION Code Section -2- 1 Please provide details showing compliance with FBC 2017 6th edition - 412.5.1 Fire separation Doors into the dwelling unit shall be equipped with self -closing devices and conform to the requirements of Section 716 with a noncombustible raised sill not less than 4 inches (102 mm) in height. Please provide details showing compliance with FBC 2017 6th edition - 412.5.1 Fire separation — for the passage door between the hangar and doweling showing compliance. Please provide details showing compliance with FBC 2017 6th edition - 412.5.2 Egress. A hangar shall provide two means of egress. One of the doors into the dwelling shall be considered as meeting only one of the two means of egress Please provide details showing compliance (with FBC 2017 6th edition - 412.5.4 Independent systems. Electrical, mechanical and plumbing drain, waste and vent (DWV) systems installed within the hangar shall be independent of the systems installed i within the dwelling. Building sewer lines shall be permitted to be connected outside the structure. FBC 2017 6th edition -107.1 General - Ple Please provide details showing compliance landings at exterior doors the slope at ex Please provide details showing compliance Draftstopping. Please provide details showing compliance access FBC 2017 6th edition -107.1 General - Ple; provide a Geotechnical report. FBC Residential 2017 6th edition-R311.3 Floors and landings of the balcony h FBC Residential 2017 6th edition - R302.12 FBC Residential 2017 6th edition - R807.1 Attic provide engineering for the hanger hydraulic door NOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (R109) of the project. BUILDI DESIGN CRITERIA [Table R301.2(1)] Floor live load (Table R301.5) x Roof live load (Table R301.6) x Ground snow load Ultimate design wind speed x Wind exposure category (R301.2.1.4) xxl High wind design criteria applicable (R301.2.1.1) x Seismic design category (SDC) [Figure R301.2(2)] SDC C&D provisions (R301.2.2) Weathering x Frost line depth Termite area x Decay area Winter design temperature Ice barrier underlayment required Flood hazards FIRE-RESISTANT CONSTRUCTION (R302) PLANNING (Chapter 3) mph Exterior walls [R302.1, Tables R302.1(1) and R302.1(2)] Townhouse separation (R302.2) Continuity and structural independence (R302.2.1, R302.2.4) ROOM PLANNING REQUIREMENTS' (R303 throuahl R305) Parapets and construction (R302.2.2, R302.2.3) Two-family dwelling separation (R302.3) Dwelling unit penetrations (R302.4) x Dwelling/garage opening/penetration protec- tion (R302.5) Dwelling/garage fire separation (R302.6) Under -stair protection (R302.7) x Wall and ceiling finishes (R302.9) x Flame spread index (R302.9.1) x Smoke -developed index (R302.9.2) Testing (R302.9.3, R302.9.4) x Insulation (R302.10) x Flame spread/smoke-developed (R302.10.1, R302.10.2) Cellulose loose -fill and exposed attic insulation (R302.10.3, R302.10.4) Testing (R302.10.5) x Fireblocking (13302.11) Draftstopping (R302.12) Fire protection of floors (R302.13) Combustible insulation clearance (R302.14) Use Area (ft2) Width Ceiling height' Natural light* Natural ventilation" Living 70 7'-0" 7'-0" 8% floor area 4% floor area Dining 70 7'-0" 7'-0" 8% floor area 4% floor area Kitchen N.A. N.A. T-0" 8% floor area 4% floor area Bedroom 70 7'-0" 7'-0" 8% floor area 4% floor area Bathroom N.A. N.A 6'-8" 3 square feet 1'/2 square feet See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation. t 6'-8" min. at plumbing fixtures and for non -habitable basement) Required heating (R303.9) SANITATION (R306 and R307) x Water closet x Lavatory x Tub or shower x Kitchen area with sink x Sanitary sewer (Chapter 30) x Private disposal (Appendix 1) GLAZING (R308) x Identification (R308.1) Louvered windows or jalousies (R308.2) Human impact loads/hazardous locations (R308.3, R308.4) Skylights and sloped glazing (R308.6) -3- BUILDING PLANNING (cont'd.) GARAGES AND CARPORTS (R309) x Floor surface noncombustible; (R309.1) Carport: open two sides; noncc floors; sloped floor (R309.2 Automatic garage door opener Fire sprinklers (R309.5) EMERGENCY ESCAPE AND RESCUE (11310) AUTOMATIC FIRE SPRINKLER SYSTEMS (R313) floor Townhouses (R313.1) One- and two-family dwellings (R313.2) e 9 NINGS Where required (R310.1) Areas, height, width, operations (R310) Window wells (R310.2.3) Under decks and porches (R310.2.4) Bars, grilles, covers and screens (R310.4) MEANS OF EGRESS (R311) x General (R311.1) x Egress door (R311.2) x Landings at exterior doors (R311.3 - R311.3.3) Vertical egress (R311.4) Construction and attachment 7311.5) Hallways (R311.6) x Stairway width, headroom, vertical rise, walk - line (R311.7.1 - R311.7.4) x Stairway treads, risers profiles) (R311.7.5 - R311.7.5.4) x Stairway landings and walking surfaces (R311.76, R311.7.7) x Handrails required (R311.7.8) x Handrail height, continuity, gn -size (R311.7.8.1 - R311.7.8.4)� x Stairway illumination (R303.7,I R311.7.9) Special stairways (R311.7.10) x Ramp slope, landings, handrails (R311.8) GUARDS AND WINDOW PROTECTION (R312) x Required for open -sided surfaces, stairs, ramps and landings > 30")above floor/ grade (R312.1.1) x Height - 36" (R312.1.2) Opening limitations (R312.1.3) x Window fall protection (R312I2) SMOKE ALARMS (R314) x Referenced standards (R314.1) Location and interconnection (R314.3, R314.4) Power source (R314.6) CARBON MONOXIDE ALARMS (13315) x New construction (R315.1, R315.2) Existing construction (R315.2.2) Referenced standard (R315.6) FOAM PLASTIC (R302.8, R316) Labeling (R316.2) Surface burning, thermal barrier, specific approval (R316.3 - R316.8) DECAY AND TERMITE PROTECTION (R317 and R318) x Protection required (Table R301.2(1), R317.1, R318.1) Quality mark (R317.2 and R318.1.1) SITE ADDRESS (R319) Address numbers (R319.1) ACCESSIBILITY (R320) x Type B dwelling units applicable (R320.1) ELEVATORS/PLATFORM LIFTS (R321) Referenced standards (R321.1 - R321.3) FLOOD -RESISTANT CONSTRUCTION (R322) General (13322.1) Hazard area and requirements (R301.2.4, R309.3, R322.2, R322.3) Design professional (R322.3.6) STORM SHELTERS (19323) General/referenced standard (R323.1) SOLAR ENERGY SYSTEMS (R324) System, installation, access (R324.2 - R324.7) MEZZANINES (R325) Area, egress, openness (R325.2 - R325.5) SWIMMING POOLS, SPAS AND HOT TUBS (R326) ISPSC (R326.1) -4- FOUN[ MATERIALS (R402) Wood foundations (R402.1) Concrete, compressive strength (R402.2, R402.3) FOOTINGS (R403) X Soil bearing value (R401.4, R403.1) X Footing width (Tables R403.1(1) - R403.1(3)] X Footing edge thickness; footing projection = 2" minimum, but <_ footing thickness (R403.1.1) Footings in SDC and D (R403.1.2 and R403.1.6.1) X Depth below (outside) grade = 12" mini um; but below frost line (R403.1.4, R403�i.4.1) Sill plate bolting in concrete/masonry ='/;2' di- ameter bolts, within 12" but not less tHan 7 bolt diameters from ends, 7" embedment (R403.1.6) Footings adjacent to slopes (R403.1.7) Frost -protected shallow foundations (R4Q3.3) Footings for precast concrete foundatii (R403.4) FOUNDATION/RETAINING WALLS (R404 - R406) Masonry foundation walls (R404.1.2) Wall height, unbalanced backfill, nominal thickness (Tables R404.1.1(1) - R404.1.1(4), R404.1.5.1] Reinforcement size and spacing (Tables R404.1.1(2) - R404.1.1(4)] Concrete foundation walls (R404.1.3) Wall height, unbalanced backfill, nominal thickness (Tables R404.1.2(1) - R404.1.2(8), R404.1.5.2] NS (Chapter 4) Horizontal and vertical reinforcement size and spacing [Tables R404.1.2(1) - R404.1.2(8), R404.1.3.2, R404.1.3.3.7] Stay -in -place forms (R404.1.3.3.6.1) SDC D provisions (R404.1.4) Height above finished grade (R404.1.6) Sill plate size (R404.3) Precast concrete foundation walls (R404.5) Drains required if habitable or usable spaces are below grade' (R405) Soil class (Table R405.1) Dampproofing if basements are below grade* (R406.1) Waterproofing if high water table` (R406.2) If uninhabitable, see Under -Floor Space (R408) COLUMNS (R407) Protection from decay or corrosion (R407.1 and R407.2) X Structural requirements (R407.3) Anchorage (R407.3) Wood columns (minimum 4" square) (R407.3) Steel columns (minimum 3" diameter, Sched- ule 40 pipe) (R407.3) UNDER -FLOOR SPACE (R408) Ventilation (R408.1 and R408.2) Unvented crawl space (R408.3) Access (R408.4) Removal of debris (R408.5) Finished grade (R408.6) Flood resistance (R408.7) 51.2 FLOORS (Chapter 5) WOOD JOISTS AND GIRDERS (11502) Species and grade (R502.1) Joists —Sleeping areas, LL = 30 psf [Table R502.3.1(1)] Joists—Nonsleeping areas, LL= 40 psf [Table R502.3.1(2)] Cantilevered joists (Tables R502.3.3(1) and R5I 2.3.3(2)] Girder and header spans (Tables R602.7(1) - R602.7(3)] Joists under bearing partitions "(13502.4) Bearing (1.5" minimum on woo ld or metal; 3" on masonry or concrete) and lapped joists (311) (13502.6, R502.6.1) Lateral restraint and bridging (R502.7, R502.71) Drilling and notching (R502.8) Fastening (R502.9) Framing of openings (13502.10) Wood trusses (13502.11) Draftstopping (R502.12) LUMBER FLOOR SHEATHING (R503.1) x ' Allowable span (Table R503.1) End joints (R503.1.1) WOOD STRUCTURAL PANEL SHEATHING (R503.2) TREATED -WOOD FLOORS (ON GROUND) (R504) Base course: 4" thick with maximum 3/4' gravel or'/2" crushed stone (R504.2.1) Moisture barrier: placed over base course (R504.2.2) Materials (R504.3) STEEL FLOOR FRAMING (R505) Cold -formed steel; applicability limits; in -line framing (R505.1) Structural framing (13505.2) Material (13505.2.1) Corrosion protection (R505.2.2) Identification (R505.2.4) Fastening (R5052.5) Floor construction (R505.3) CONCRETE FLOORS (ON GROUND) (R506) x Thickness: 31/2" minimum; Concrete strength (R506.1) Support: prepared subgrade; maximum earth fill = 8"; maximum sand or gravel fill = 24" (R506.2.1) Base course: 4" graded with 2" maximum aggregate (R506.2.2) x Vapor retarder (R506.2.3) x Reinforcement support (R506.2.4) Grade (R503.2.1) EXTERIOR DECKS (R507) Thickness (13503.2.1) Support, attachment (13507.1 - R5072.4) Allowable spans Plastic composite materials (R507.3) (Tables R503.2.1.1(1) and R503.2.1.1(2)] Decking/deck joists (R507.4, R507.5) Installation [Table 602.3(1)] I Deck beams (R507.6) PARTICLEBOARD UNDERLAYMENT (R503.3) Deck posts, connections, footings Grade (13503.3.1) (13507. Z 1, R507.8) Thickness (R503.3.2) Installation (Table R602.3(1)) N WOOD CONSTRUCTION (R602) Construction [Figures R602.3(1) and R602.3(2)] Stud grade (R602.2) Design/construction (R602.3) Stud spacing [R602.3.1, Table R602.3(5)] Interior load -bearing walls (R602.4) Interior nonbearing walls: 2" x 3" at 24" o.c. or 2" x 4" flat at 16" o.c. (R602.5) Drilling and notching —studs (R602.6) Drilling and notching —top plate (R602.6.1) Headers [Tables R602.7(1) - R602.7(3) I and Figure R602.7.2] Fireblocking (R602.8, R302.11) Cripple walls (R602.9) Wall bracing, lines, panels (R602.10.1, R602.10.2) Required length of bracing, method [R602.10.3, R602.10.4, Tables R602.10.3(1) and R602.10.3(3)] Minimum length, connections, support, joint: cripple walls (R602.10.5 - R602.10.11i) —Wall anchorage (SDC C and D) (R602.11) Simplified wall bracing (R602.12) STEEL WALL FRAMING (R603) General (R603.1) Structural framing (R603.2) WALL CONSTRUCTION (Chapter 6) Material (R603.2.1) Corrosion protection (R603.2.2) Identification (R603.2.4) Fastening (R603.2.5) Wall construction (R603.3 - R603.5) Headers (R603.6) Studs, tracks and structural sheathing (R603.7 - R603.9) SHEATHING (R604 and R605) Wood structural panels (R604) Particleboard (R605) MASONRY CONSTRUCTION (R606 - R610) x General design (R606) Seismic requirements (R606.12) Glass unit masonry (R607) x Exterior concrete wall construction (R608) x Exterior windows/doors (R609) Glass unit masonry (R610) STRUCTURAL INSULATED PANEL WALL CONSTRUCTION (R610) Applicability (R610.2) Materials (R610.3) Wall panels, construction details (R610.4 - R610.10) INTERIOR WALL COVERING (R702) Plaster material (R702.2) Plaster support (R702.2.3) x Gypsum board materials (R7C Gypsum board support, applic tening (R702.3.2 - R702.3. Ceramic tile (R702.4) Other finishes (R702.5 and R; Vapor retarders (R702.7) EXTERIOR WALL COVERING (R703) Water -resistive barrier (R703. Attachment and minimum thic [Table R703.3(1)] Wood siding (R703.5) L COVERING (Chapter 7) Wood shakes and shingles (R703.6) x Exterior plaster (R703.7) Stone & masonry veneer (R703.8 & Figure R703.8); Steel angle lintels-4" minimum 3.1) bearing each end (R703.8.3) on and fas- Veneer ties: #9 U.S. gage wire or #22 U.S. gage by corrugated metal; horizontal and vertical spacing; 2.67 square feet maximum area supported (wind > 30 psf and SDC C or D, maximum area = 2 6) square feet) (R703.8.4.1) x Flashing (R703.4 and R703.8.5) Exterior insulation and finish systems (R703.9) Fiber cement siding (R703.10) ;ss Vinyl siding (R703.11) Other sidings (R703.12 - R703.17) ROOF -CEILING CONSTRUCTION (Chapter 8) WOOD ROOF FRAMING (R802) Fire -retardant -treated wood (R802.1.5) Framing details (R802.3) Rafter ties (17802.3.1) Collar ties (4' o.c., in upper third of attic) (R802.3.1) Purlins (2" x 4" at 4' o.c. minimum) (Figure R802.5.1, R802.5.1) Bearing (R802.6) Cutting and notching (R802.7,) x Engineered wood products (R802.7.2) Lateral support and bridging I(R802.8) Framing of openings (R802.9) x Wood trusses (13802.10) Roof tie -down (R802.11) j CEILING JOISTS [Tables R802.4(1), R8 2.4(2)] Without attic storage, LL = 11 Opsf With attic storage LL = 20p If Spacing Species and grade Span Size RAFTERS [Tables R802.5.1(1) - R802.5.1(8)] Ground snow load/LL = 20 psf Controlling design (LL or snow) Ceiling not attached/ceiling attached Spacing Species and grade Span Size Hc/HR; Adjustment factor ROOF SHEATHING (R803.2) Grade x Thickness FRTW allowable stresses/grading x Allowable spans [Table R503.2.1.1(1)] Installation (R803.2.3) -8- ROOF-CEILI STEEL ROOF FRAMING (R804) General (R804.1) Structural framing (R804.2) Material (R804.2.1) Corrosion protection (R804.2.2) Identification (R804.2.3) Fastening (14804.2.5) .10Z6]A ROOF CLASSIFICATION (R902) Roof covering materials (13902.1) WEATHER PROTECTION (R903) Flashing (R903.2) Coping (R903.3). Roof drainage (R903.4) MATERIALS (R904) Compatibility; specifications; physical cha teristics; identification (R904.2 - R904. REQUIREMENTS FOR ROOF COVERINGS (R905) x Underlayment (R905.1.1, R905.1.2) x Asphalt shingles (R905.2) Clay and concrete the (R905.3) Metal roof shingles (R905.4) Mineral -surfaced roll roofing (R905.5) Slate shingles (R905.6) Wood shingles (R905.7). Wood shakes (R905.8) Built-up roofs (R905.9) CHIMNEYS AND MASONRY FIREPLACES (R1001) Construction (Figure R1001.1 and Table R1001.1) SDC D reinforcing/anchorage (R1001.3 and R1001.4) Firebox walls and dimensions, (R1001.5 and R1001.6) Steel fireplace units (R1001.5.1) Lintel (noncombustible) (R1001.7) 1 P CONSTRUCTION (cont'd.) Roof construction (R804.3) Roof tie -down (R804.3.8) ROOF VENTILATION (R806) Ventilation requirements (R806.1 - R806.5) ATTIC ACCESS (R807) Access requirements (807.1) EMBLIES (Chapter 9) Metal roof panels (R905.10) Modified bitumen roofing (R905.11) Thermoset single -ply roofing (13905.12) Thermoplastic single -ply roofing (R905.13) Sprayed polyurethane foam roofing (R905.14) Liquid -applied roofing (R905.15) Photovoltaic shingles (R905.16) ROOF INSULATION (R906) General (R906.1) ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS (R907) Materials and installation (R9071 - R907.5) REROOFING (R908)- Materials and methods (R908.1) Structural support (R908.2) Replacement/re-covering (h908.3, R908.4) ROOFTOP - MOUNTED PHOTOVOLTAIC PANEL SYSTEMS (R909) Materials and installation (R909.1 - R909.3) EPLACES (Chapter 10) Hearth extension (R1001.9, R1001.10) Fireplace clearance (R1001.11) Fireblocking (R1001.12) MASONRY CHIMNEYS (R1003) Construction (Table R1001.1, R1003.2, R1003.3, and Figure R1001.1) Corbeling (R1003.5) CHIMNEYS AND FIREPLACES (cont'd.) Changes in dimension (R1003.6) Additional load (R1003.8) Termination (R1003.9) Spark arrestors (R1003.9.2) Wall thickness; >_ 4" (R1003.10) Flue lining - material/installation (R1003.11 and R1003.12) Multiple flues (R1003.13) Flue area (appliance) (R1003.14) Flue area (masonry fireplace) (R� Inlet (R1003.16) Cleanout opening (R1003.17) Chimney clearance (R1003.18) Fireblocking (R1003.19) Chimney crickets (R1003.20) FACTORY -BUILT FIREPLACES (R1004) Listed and labeled (R1004.1) Installation (R1004.2 - R1004.5) FACTORY -BUILT CHIMNEYS (R1005) Listed and labeled (R1005.1) 003.15) Installation (R1005.3 and R1005.4) EXTERIOR AIR SUPPLY (R1006) Intake size (R1006.2, R1006.4) ENERGY EFFICIENCY (Chapter 11) Compliance; information Electrical (N1104) (N1101.5, N1101.13) Simulated performance (N1105) Climate zone (Table N1101.7) ERI compliance alternative (N1106) Building thermal envelope (NI1102) Existing buildings (N1107 - N1111) Systems (N1103) I MECHANICAL (Chapters 12-23) Appliance labeling (M1302, M1303) Chimney and vent location and terminations (Chapters 10 and 18) Appliance access (M1305, i 1401) Special equipment (Chapter 19) Appliance installation (M1307) Boilers/water heaters (Chapter20) Heating and cooling equipment; load calcula- Hydronic piping (Chapter2l) tions (Chapter 14) Exhaust systems (Chapter 15) I Specialp pipingand storage systems (Chapter) Duct systems (Chapter 16)1 Solar thermal energy systems (Chapter23) Combustion air (Chapter 17) Penetrations of fire -resistance rated assem- blies (R302.4, R302.5) Application (G2401.1) _ i General regulations (G2404) Appliance location (G2406) Air requirements (G2407)� I Installation (G2408) I FUEL GAS (Chapter 24) Clearances (G2409) Electrical and electrical bonding (G2410, G2411) Pipe sizing (G2413) Piping materials (G2414) -10- EL GAS (cont'd) Piping installation (G2415 and G241 Piping support (G2418 and G2424) Valves, controls, connections (G2420, G2421 and G2422) Venting (G2425 - G2429) Misc appliances (G2423, G2430 - G2454) PLUMBING (Chapters 25-33) Water service location and depth (P2603, P2604) Sanitary and storm sewer location (P2603, P2604) Piping support (Table P2605.1) Listed plastic materials (P2609) Plumbing fixtures (Chapter27) Water heater size and location (CI Water supply and distribution syste and calculations (Chapter29) Dwelling unit fire sprinkler systems NFPA 13D system (P2904.1) Temperature rating (P2904.2.1, P2904.2.2) ELECT Freezing protection (P2904.2.3) Sprinkler coverage (P2904.2.4) I depth Piping materials (P2904.3) Flow rates (P2904.4.1, P2904.4.2) Water supply capacity (P2904.5.2) Pipe sizing (P2904.6) gr28) Drain, waste and vent pipe sizing and riser diagram (P3004, P3005, Chapter3l) lesign Sumps and ejectors (P3007) ?904) Backwater valves (P3008) Fixture traps (P3201) Storm drainage (Chapter 33) Penetrations of fire -resistance rated assem- blies (R302.4, R302.5) Penetrations of fire -resistance rated asserr blies (E3402.2) Listed and labeled materials (E3403) Service equipment and location (E3405, E3601, E3606) Service size and load calculations (E3602) Available fault current (E3606) System grounding (E3607) Required branch circuits (E3703) Feeder requirements and load calculations (E3704) f (Chapters 34-43) Wiring methods (Chapter 38) Required lighting and receptacle outlets (E3901, E3903) Ground -fault and arc -fault circuit -interrupter protection (E3902) Devices and lighting fixtures (Chapter40) Appliance installation (Chapter4l) Swimming pools (Chapter42) Class 2 remote -control, signaling and power - limited circuits (Chapter 43) MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E) Provisions adopted (R102.5) Compliance with Appendix E verified -11- PASSIVE RADON GAS CONTROLS (Appendix F) Provisions adopted (R102.5) Compliance with Appendix F verified PATIO I COVERS (Appendix H) Provisions adopted (R102.5) Compliance with Appendix H verified PRIVATE I SEWAGE DISPOSAL (Appendix 1) Provisions adopted (R102.5) Compliance with Appendix I verified EXISTING BUILDINGS AND STRUCTURES (Appendix J) Provisions adopted (R102.5) Compliance with Appendix J verified SOUND TRANSMISSION (Appendix K) Provisions adopted (R102.5) Compliance with Appendix K verified HOME DAY CARE—R-3 OCCUPANCY (Appendix M) Provisions adopted (R102.5) Compliance with Appendix M verified AUTOMATIC VEHICULAR GATES (Appendix 0) Provisions adopted (R102.5) Compliance with Appendix O verified -12-