The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
Recommended STRONGBACK for Floor Trusses
Refer to information on truss engineering drawings.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. A
•
(2)led nails @ top& bottom of 2x4 vertical block. SEAT PLATES BY CHAMBERS TRUSS
2x6 (MIN) STRONGBACK restrained at each end,
wgelloa nails Ig seen vertical. Locate STRONGBACK as clo(;e to bottom cord as possible.
ISTRONGBACKS are recommended to MINIMIZE VIBRATION
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY. ..
6r-
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
=LIFE SAFETY WARNfNG
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
30' Sp or less A
60 degrees
or Itiss
Tag line I2 span ssiss-11111,
approx.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
Tag line 4prox V3 to
t/2 of Span.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
0 Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !!
Do not set floor trusses upside down! Refer to engineering drawings.
1-04-00
SQUARE (UT END
2X4 TOP (;HORD
WALL HEIGHT VARIES
END DETAIL: TYPICAL
SQUARE CUT END
4X2 TOP CHORD SQUARE CUT END
LEDGER HEIGHT 10'- 5" 4X2 TOP CHORD
END DETAIL: 16" FLOOR LEDGER HEIGHT 10'- 5"
TOP BEARING _ END DETAIL: 20" FLOOR
SQUARE CUT END
4X2 TOP CHORD
WALL HEIGHT 9'-4"
END DETAIL: 16" FLOOR
BOTTOM BEARING
OCONNECTIONS DESIGNED
AND SUPPLIED BY OTHERS
J16REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS
CARRYING
TRUSS
HANGER IO
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
`Please refer to Standard Engineering package for general instuction on installing hangers
1Od=0.148" x 3" 16d=0.162" x 3 1/2"
TES:
.L BEAMS BY OTHERS.
IUSS TO WALL CONNECTIONS DESIGNED & SUPPLIED BY OTHERS.
Hatch Legend
o°o°o UP -TURN BEAM @ 10'- 8"
�BRG WALL @ 20'
a aBRIG WALL @9'
�BRG WALL @ 9'- 4"
86-0+:..00
X2
W.
soEll
NO
ME
Ha
X
,It
US$IES
A
STAIRS
OPEN TO ABOVE
FGE
0
0
0
a
HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT
CORNDERJACKS
ARE NOT BEVELED.
SEE STANDARD
24 O.C. THRU
CORNERONLY JACKS
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
Y
�U
tii
tic
Z
NUo
N
FMIRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
'he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority fa
!etermining successful fabrication of the trusses. -
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
ndersgned agrees that no backcharges will be allowed. In the event such written notice is fumished Chambers Trus;
hall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option
,fter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of "BCSI" summary sheet by TPI & WTCA
5. Delivery is to job site. It is the buyers responsibility to make the job site suitable for delivery. Chambers Truss has
le sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
e responsible for dump delivery only. The buyer is responsible for additional delivery expenses 9 Chambers Truss has
I redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
rsponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour
is for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or 6 no agreement a reasonable price.
(voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
-livery 4 buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
Iasonable attorneys fee for collections in event of payment not timely made. 1-W % per month service charge will be
ided for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionalty guarantees
ayment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
tdersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the
cipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
:rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
If. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities For
instruction Using Metal Plate Connected Wood Trusses ANSI/TPIANTCA 4 - 2002"
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing arerequired and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
.11110116,
Trusses must be set plumb and square
Do not set bunks or stack of plywood , roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING TH►S
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce, Florida 34982.6423
800-551-5932
Fort Pierce 772-465.2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart 772-286.3302
Web Site: CHAMBERSTRUSS.COM
Email: MNL@CHAMBERSTRUSS.COM
+r�SL°' �t'WYIInbI
(&APPROVED L nVi iiGUCU hS NU ED
[]REVISE AND RESUBMIT REJECTED
I✓ NNcn
BY
t t t %tt"N
Fort Pierce, FL 34950
O
91
8-00-00
GRH
S
J3 �.
O
it
o
LOADING/DESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 180I.6.1
DESIGN CRITERIA
County Saint Lucie County
Building Department Saint Lucie County
Wind Design Criteria ASCE 2010
Wind Design Method MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
Loading in PSF Roof R.D.L. Floor
Top Chord Live 20 40
Top Chord Dead 7 4.2 10
Bottom Chord Live *10-Non Conccurent 0
Bottom Chord Dead 10 3 5
Total Load 47 7.2 55
Duration Factor 1.25 0
Wind Speed 170mph
Top Chord C.B. Sheathing by builder
Bottom Chord C.B. Sheathing by builder
Highest Mean Height 25'
Building Type Enclosed
Building Category It: Non Restrictive
Exposure Category C>Open Terrain with scattered obstructions
Miles from Ocean 10
Conforms to Florida Building Code 2017
R. D.L.= Restraining Dead Load C.B =Continuous Bracing
R A
_
-PLY LEDGER
10'- 1'
TOP
S
d
O
Z
C)
U
O
LU
N
N
CT
m
69 69
T
+
U)
re
Verify DESIGN CRITERIA shown above with the
Design the resent and pour onsibility 191nof the
9 p Y
Building Designer and/or Engineer of Record
°0
tL--
N
X
Chambers Truss Inc. Drawing Name: 75205
SCALE: 1/4" = 1'-0"
194 total trusses, 59 unique designs
Designer: BLW Reviewed by:
Date: 07/25/18 Revised 09/20/18
FOR
Tim Mcewen
DESCRIPTION:
TREASURE COAST PARK
Page 1 of 2 CUSTOMER INITIALS EACH PAGE
75205
20-08-00
8-00-00
I All load bearing walls, headers,
A, WARNING - g
The size of these trusses makes it necessary that they a set by a profeesional builder beams, &lintels must be i n place
familiar with and experienced in the problems and dangers of setting large span trusses. at Indicated height before trusses
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should br, at I are installed. I
the job site when trusses are erected to provide supervision and advice.
Recommended STRONGBACK for Floor Trusses • •
Refer to information on truss engineering drawings.
(2) led nails @ top & bottom of 20 vertical block. SEAT PLATES BY CHAMBERS TRU
2x6 (MIN) STRONGBACK restrained at each end.
6d nails @ each vertical. Locale STRONGBACK as cl+ to bottom cord as possible.
iTRONGBACKS are recommended to MINIMIZE VIBRATION
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY. A
1
-01
6r
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
AS
=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
:to,
or less
60 degrees
orless
Tag � in span
g approx.
REFER TO BCSI
Truss must he set this way if crane is used.
Truss is an example, your buss may not match.
Insist cram operator sets truss this way.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
Bar
�Ipprox 2/3 n. �,
Tail line 1/2 of SPaI.
REFER TO BCSI
Truss must be set this way if crane is used
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
0 Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !!
Do no� set floor trusses upside down! Refer to engineering drawings.
SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT VARIES
END DETAIL: TYPICAL
SQUARE CUT END
4X2 TOP CHORD
LEDGER HEIGHT 10'- 5"
END DETAIL: 16" FLOOR
1-04-00
SQUARE CUT END
4X2 TOP CHORD
WALL HEIGHT 9'-4"
END DETA;L: 16" FLOOR
BOTTOM BEARING
o -05-0
I
SQUARE CUT IEND
4X2 TOF CHORD
LEDGER HEIGHT 10'- 5"
END DETAIL: 0" FLOOR
0 CONNECTIONS DESIGNED
AND SUPPLIED BY OTHERS
J JREPRESENTS A HANGER
HANGER ,iCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS
CAPI+PING
TR'ISS
HANGER ID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
*Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1/2"
DOTES:
'ALL BEAMS BY OTHERS.
'TRUSS TO WALL CONNECTIONS DESIGNED & SUPPLIED BY OTHERS.
2-PLY LEDGER TOP na 10'- 51
Hatch Legend
o°o°o UP -TURN BEAM @ 10'- 811
�BRIG WALL @ 20'
a a a BRIG WALL @ 9'
�BRG WALL @ 91- 411
0■
sm
M10
C
a
LU
tit
a
io
N
x
v
C
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
STAIRS
OPEN TO ABOVE
FGE
11-04-00
0
S
HIP CARRIER LOCATED AS DIMENSIONED ON tAYOIJT
CORNDER JACKS
ARE NOT BEVELED.
SEESTANDARD
24' O.C. THRU
CORNER JACKS
ONLY 24' ' 1-1/'
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
N
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
ie undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout which is the sole authority to
dermining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by Certified mail to Chambers Truss within ten (10) days of delivery thf
.dersgned agrees that no backcharges will be allowed. In the event such written notice is famished Chambers Trus:
all have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option
ter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersgned acknowledges receipt of 'BCSI* summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyers responsibility to make the job site suitable for delivery. Chambers Truss ha:
e sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss wit
responsible for dump delivery only. The buyer is responsible for additional delivery expenses 9 Chambers Truss ha:
redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
sponsiblo to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this IayouL A $50 per hour
e for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or 9 no agreement a reasonable price
voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date e
:livery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Trus:
asonable attorney's fee for collections in event of payment not timely made. 1-112 % per month service charge will d
Ided for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantee
lyment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and thI
(dersgned agrees to pay such indebtedness including attorneys fees, 9 default in payment for material be made by thi
cipient.
10. In the event of any litigation concerning this agreement the items furnished hereunder or payments referred b
:rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida. r
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities Fc
onstruction Using Metal Plate Connected Wood Trusses ANSI/rPIM/TCA 4 - 2002'"'
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing arerequired and can save life and property
and is the responsibility of the truss erector.
..119111
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury 8r damage.
IAVI
Trusses must be sett plumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce, Florida 34982.6423
800-551-5932
Fort Pierce 772-465.2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAILACHAMBERSTRUSS.COM
DESIGN CRITERIA
APPROVED � APPROVED AS NOTED
REVISE AND RESUBMIT ❑ REJECTED --
NFORM
SUBMITTALV,1.0 REVIEWED FOR DESIGN To CONTRACT OCl
Architectonic Inc.
Fort Pierce, FL 34950
LOADING/DESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
,�
Kl3 VVHLL m a
County Saint Lucie County
Building Department Saint Lucie County
Wind Design Criteria ASCE 2010
Wind Design Method MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
Loading in PSF Roof R.D.L. Floor
ER TOP 10'- 1'
Or
F
Top Chord Live 20 40
s
Top Chord Dead 7 4.2 10
Bottom Chord Live *10-Non Conccurent 0
oo
Bottom Chord Dead 10 3 5
Total Load 47 7.2 55
oDuration
Factor 1.25 0
*GRH
Wind Speed 170mph
Top Chord C.B. Sheathing by builder
Bottom Chord C.B. Sheathing by builder
Highest Mean Height 25'
Building Type Enclosed
J--
Building Category II: Non Restrictive
Exposure Category C>Open Terrain with scattered obstructions
2
Miles from Ocean 10
Conforms to Florida Building Code 2017
R.D.L =Restraining Dead Load C.B =Continuous Bracing
V
o
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75205
SCALE: 1/4" = 1'-0"
194 total trusses, 59 unique designs
Designer: BLW Reviewed by: _
Date: 07/25/18 Revised 09/20/18
FOR
Tim Mcewen
DESCRIPTION:
TREASURE COAST PARK
Page 1 of 2 CUSTOMER INITIALS EACH PAGE
75205
WARNING
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
Recommended STRONGBACK for Floor Trusses
Refer to information on truss engineering drawings.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. n
•
•
(2) led nails @ top &bottom of 2x°vertical block.
SEAT PLATES BY CHAMBERS TRUSS
2x6 (MIN) STRONGBACK restrained at each end. Secure w/(3)16d nails @ each vertical. Locate STRONGSACK as clol;e to bottom cord ss possible.
STRONGBACKS are recommended to MINIMIZE VIBRATION
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY. ,t,
1
6r
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
=LIFE SAFETY WARNING
1 • %
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
Or less
aypox.
REFER TO BCSI
Truss must be set this way if vane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
Bar
line !r_bpmx 2J3 to ..0Tag
1/2 or Span.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
3U BY THE PEAK.
CONSULT BCSI
A Do not stand on trusses until they
are braced per
BCSI
& properly nailed to straps and hangers !!
Do not set floor
trusses upside down!
Refer to
engineering drawings.
1-04-00
0
oo6 SQUARE CUT END
SQUARE CUT END 4X2 TOP CHORD
2X4 TOP CHORD WALL HEIGHT9'-4"
WALL HEIGHT VARIES END DETAIL: 16" FLOOR
END DETAIL: TYPICAL BOTTOM BEARING
I
SQUARE CUT END
4X2 TOP CHORD
LEDGER HEIGHT 10'- 5"
END DETAIL: 16" FLOOR
TOP BEARING
CONNECTIONS DESIGNED
AND SUPPLIED BY OTHERS
sill REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS
CARRYING
TRUSS
MANGER ID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
*Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1/2"
DOTES:
'ALL BEAMS BY OTHERS.
'TRUSS TO WALL CONNECTIONS DESIGNED & SUPPLIED BY OTHERS.
SQUARE CUT END
4X2 TOP CHORD
LEDGER HEIGHT 10'- 5"
END DETAIL: 20" FLOOF
Hatch Legend
o o UP -TURN BEAM @ 101- 8"
♦ ♦ ♦ . •
WE .. • •
[S�rBIIr➢]
C
7-04-08
m
STAIRS
U
- OPEN TO ABOVE
FLD N
a W
w
w
FLD
� I „-oa-oo
Q
rn o
0
FLU VJv
U
U
io
FGE
HIP CARRIER
LOCATED AS DIMENSIONED ON LAYOUT
CORNDER JACKS
ARE NOT BEVELED.
Y
�
r'X
SEE STANDARD
ENGINEERING.
O w
C Z
.00
N
2r O.C. THRU
CORNERJACKS
ONLY 24"
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
11�►�e m
J1
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authoril)
etermining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery
undersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers T
hall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers op
%fter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job she suitable for delivery. Chambers Truss
e sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss
e responsible for dump delivery only. The buyer is responsible for additional delivery expenses 9 Chambers Truss
o redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buy(
esponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change 9 any changes are made in this layout A $50 per I
ee for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable p
nvoice will be made on delivery and paid within terns of net on delivery. Invoice may be made at scheduled dat
elive A buyer cannot accept delivery of fabricated trusses. The n ry y D ry undersigned agrees to pay Chambers Ti
easonable attorney's fee for collections in event of payment not timely made. 1-112 % per month service charge wil
dded for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guaran
ayment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and
ndersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by
ecipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments refere
Shelf, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities
onstruction Using Metal Plate Connected Wood Trusses ANSI/TPIM/TCA 4 - 2002'"'
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they ar
set, failure to do so can result in roof collapse.
Temporary and permanent bracing arerequired and can save life and propeq
and is the responsibility of the truss erector.
1.119111111.1
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be sett plumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce, Florida 34982.6423
800.551-5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart T72-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
LOADING/DESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
DESIGN CRITERIA
County
Saint Lucie County
Building Department
Saint Lucie County
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Direcbonal)/C-C hybrid Wind ASCE 7-10
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 40
Top Chord Dead
7 4.2 10
Bottom Chord Live
*10-Non Conccurent 0
Bottom Chord Dead
10 3 5
Total Load
47 7.2 55
Duration Factor
1.25 0
Wind Speed
170mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
25'
Building Type
Enclosed
Building Category
II: Non Restrictive
Exposure Category
C>Open Terrain with scattered obstructions
Miles from Ocean
10
Conforms to Florida Building Code 2017
R.D.L =Restraining Dead Load
C.B.=Continuous Bracing
U Verify DESIGN CRITERIA shown above with the
S building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75205
SCALE: 1/4" = 1'-011
194 total trusses, 59 unique designs
Designer: BLW Reviewed by:
Date: 07/25/18 Revised 09/20/18
FOR
Tim Mcewen
DESCRIPTION:
TREASURE COAST PARK
Page 1 of 2 CUSTOMER INITIALS EACH PAGE
75205
WARNING
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span tru =ses.
The builder and erector should consult with an engineer licensed in Florida specialising
in wood roof trusses about the safe erection of these trusses. The engineer should file at
the job site when trusses are erected to provide supervision and advice.
Recommended STRONGBACK for Floor Trusses
Refer to information on truss engineering drawings.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. Ai
•
•
(2) 16d nails @ top & bottom of 2x4 vertical block. SEAT PLATES BY CHAMBERS TRUSS
2x6 (MIN) STRONGBACK restrained at each end.
w/(3)16d nails @ each vertical, Locate STRONGBACK as clo�s to bottom cord as possible.
TRONGBACKS are recommended to MINIMIZE VIBRATION
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
J% TO DETERMINE IF MULTIPLE PLY.
6r—
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
30' Spin or less A
60 degrees
or less
Taff fine 1R span
aimmoll
ap,imx.
REFER TO BCSI
Truss must be set this way it crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
Tag line 1�Lpprox 2J3 to
112 of Span.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
z�NDo not stand on trusses until they
are braced per
BCSI
& properly nailed to straps and hangers !In
Do not set floor
trusses upside down!
Refer to
engineering drawings.
1-04-00
SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT VARIES
END DETAIL: TYPICAL
SQUARE CUT'END
4X2 TOP CHORD
WALL HEIGHT 9'-4"
END DETAIL: 16" FLOOR
BOTTOM BEARING
TRUSSIES
C
LUE'OI[ON
-- -
- u-n-va
m m m g g 5 3 5 g 3
—
O
0
T
1-04-0
1-01-0
oo
o
-05-0
-04 0
a
STAIRS
Z
SQUARE CUT END
a
4X2 TOP CHORD
SQUARE CUT END
LEDGER HEIGHT 10'- 5"
4X2 TOP CHORD
O
[FLD
END DETAIL: 16" FLOOR
LEDGER HEIGHT 10'- 5"
OPEN TO ABOVE
TOP BEARING
END DETAIL: 20" FLOOR
"'
w
IJ.J
-PLY LEDGER TOP 10'- 5'
w
11-04-00
0 CONNECTIONS DESIGNED
AND SUPPLIED BY OTHERS
REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS
CARRYING
TRUSS
HANGER ID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
"Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1/2"
IOTES:
ALL BEAMS BY OTHERS.
TRUSS TO WALL CONNECTIONS DESIGNED & SUPPLIED BY OTHERS.
Hatch Legend
o°o°o UP -TURN BEAM @ 10'- 8"
BRIG WALL @ 20'
la a aIBRG WALL @ 9'
BRIG WALL"' 9'- 4"
N
X
V
(D
U
FGE
0
0
0
HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT
CORNDERJACKS
ARE NOT BEVELED.
SEE STANDARD
24'O.C. THRU
CORNER JACKS ONLY 24_
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
IIlyi/_rrelME10]112111
N
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout which is the sole authority
-termining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery I
tdersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Tru
tall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers optk
fter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss h
e sole authority to determine the suitability of the job site or a portion of the jab site for delivery. Chambers Truss i
3 responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss h
redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer
xponsible to Chambers Truss for towing costs due to site condifions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout A $50 per In:
e for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable lark
voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date
-livery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Tin,
Iasonable attorney's fee for collections in event of payment not timely made. 1-112 % per month service charge will
Idled for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarante
3yment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and I
tdersgned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by I
cipient.
10. In the event of any litigation concerning this agreement the items furnished hereunder or payments referred
-rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities F
onstruction Using Metal Plate Connected Wood Trusses ANSIrrPIAVTCA 4 - 2D02'"'
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing arerequired and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
ailloill
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 can er Avenue
Fort Pierce, Florida 34982-6423
800-551.5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
DESIGN CRITERIA
LOADIN(1IDESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
'"-- --""
County Saint Lucie County
Building Department Saint Lucie County
Wind Design Criteria ASCE 2010
IN BEAM
Wind Design Method MWFRS(Directtonal)/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
ER TOP 10'- 1'
Loading in PSF Roof R.D.L. Floor
GRH
¢ems
Top Chord Live 20 40
Top Chord Dead 7 4.2 10
Bottom Chord Live `10-Non Conccurent 0
o
J3
4
Bottom Chord Dead 10 3 5
o
`
�
Total Load 47 7.2 55
n
Duration Factor 1.25 0
Wind Speed 170mph
it
Top Chord C.B. Sheathing by builder
Bottom Chord C.B. Sheathing by builder
U) P/
Highest Mean Height 25'
Building Type Enclosed
-
Building Category It Non Restrictive
Exposure Category C>Open Terrain with scattered obstructions
Miles from Ocean 10
Conforms to Florida Building Code 2017
R.D.L.=Restraining Dead Load C.B.=Continuous Bracing
V
o
Verify DESIGN CRITERIA shown above with the
g
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75205
SCALE: 1/4" = 1'-0"
194 total trusses, 59 unique designs
Designer: BLW Reviewed by: _
Date: 07/25/18 Revised 09/20/18
FOR
Tim Mcewen
DESCRIPTION:
TREASURE COAST PARK
Page 1 of 2 CUSTOMER INITIALS EACH PAGE
75205