Loading...
HomeMy WebLinkAboutPRE-FABRICATED GENERATOR PAD DETAILf C SEPARATE SUBMITTAL W (SEE CONCRETE PAD I M SCHEDULE FOR MINIMUM ' IN;EIGHTlEQUIRED);- I.--. N G I N 'E rR I G PAD i� THICKNESS 1 FRONT VIEW PAD LENGTH PAD, ANCHOR FG3154-4G LOCATION r- - --` r---}-----I r--� ( T_�1.063" F=3---o-C-=-== 1 N I n 1 1 I17:625� ' NCD - L l WIND LOAD I I I F RESULTANT { _ N z Lu FF 95' SIDE VIEW PAD PAD WIDTH THICKNESS HURRICANE CONCRETE PAD FOR GENERATORS •ALLOWABLE DESIGN PRESSURE: SEE TABLE (GENE RAC AND H O N EY W E L L U N ITS) REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN (ON -GRADE APPLICATIONS, ONLY) ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE: WITH THE APPLICABLE BUILDING CODE SHALL BE LESS ,o• ,;''? THAN OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN h s PRESSURE'ASD' CAPACITY VALUES LISTED HEREIN FOR GE ERAL NOTES ANY ASSEMBLY AS SHOWN. �THIS.SYSTEM '� .HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE f \ \ 1pry �-;)I r REQUIREMENTS OF THE FLORIDA BUILDING CODE 6TH EDITION (2017) FBC. (�\ \ 2 POSITIVE AND NEGATIVE DESIGN PRESSURES CALLULAI ED I-UR use WII H I HIS SYSTEM SHALL BE --..,,,,, �. _ .�DETERMINED'BY OTHERS ON AJOB-SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. ' 3 Y -MAXIMUM DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS _�. I \ l 4. THE AREA UNDER CONCRETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, Lu Y _ g STALLATION ON COMPACTED SOIL d : S L pTI{ERSIETHESE=GONCRETE PADS HAVE BEEN DES VERIFI ; GNED OR A MINIMUM SOIL COEFFICIENT OFED BY dt'� Y'j,C:: FRICTION] 0.25 AND MINIMUM BEARING CAPACITY OF 2,000 PSF AND MINIMUM SUBGRADE 14. MODULUS z \ \ Gji .✓` f �' _ - 100 PCI. SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE "I� ITjy ENGINEER \� ,� OF RECORD SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH THE WORK. I - \ 5. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 6. \ '- •4-... \ ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS.SHOWN ONLY USE OF THIS ,� �: '� SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL $ COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL.yr ' N' �ENGSN FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR Pp0 BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN 15" j fr ISOMETRIC VIEW 7. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE#THE FULL RESPONiSIBILITY.;OF�THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED:OR AL•TERED.,WATERPR00FING t MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION;OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPR60FIffd OpR LEAKAGE , ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE;FH.E FULLRESPONSIBILi7Y�0KTHE ---=a INSTALLING CONTRACTOR. "- 8. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE I ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE w ¢^'"L +'.,', („ p @ ("'' RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN. WHICH SHALL a 4 ✓ ,) -" � ] BE COORDINATED BY THE PERMITTING CONTRACTOR•) �` j L,� ) ) a? = i . 'i'°°'-6 a ) t^^^ -•a - °^"'I 1 9. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE j �-"''�/; 3ya„ { INFORMATION CONTAINED HEREIN IS BASED ON CONTRgCTORhS(JPPI:IEDEDATAy`ANO;t",,,, I! MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO I ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS I PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION :HORIAGE:w OF MATERIf{I5. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND (PART# 165003 & TEST REPORT 95329 BY ELEMENT MATERIALS TECHNOLOGY) W/ 3/8" DIA. BOLT ASTM A307, 3" MIN. EDGE DISTANCE, 1-3/8" EMBED. INTO CONCRETE (BASE PAN MIN. THICKNESS = 0.69" AND MIN. BEARING STRENGTH = 6 KSI) PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE ;CONCRE?E PAD SCHEDULE UNIT DIMENSION$`(IN) 1 b ! < � � •''1 PAD DIMENSIONS (IN) WIND LOADS _ MINIMUM (UNIYr PAD ALLOWABLE ALLOWABLE ITEM -GENERATOR UNIT WEIGHT CONCRETE PAD MODEL # WEIGHT WIDTH,•LENGTH •HEIGFT � S) a ). WIDTH LENGTH THICKNESS (LBS) PRESSURE RESULTANT (PSF) (LBS) 1 8KW 25.00 4eQ r29r00 dr "�360 n }FCti3154-M1G 30.56 53.56 4.00 240 30.72 296.93 2 10KW 25.00 48.00 29.00 407 FG3154-4G 30.56 53.56 4.00 240 33.13 320.25 3 14KW i 25.00 48.00 29.00 435 FG3154-4G 30.56 53.56 4.00 240 34.57 334.21 4 16KW i 25.00 f48.00 29.00 448 FG3154-4G 30.5G 53.56 4.00 240K,; 35.26- 340.85 S 16KW ! 25.0 48.00 29.00 513 FG3154-4G 30.56 53.56 4 DO 240 �38 53� rr32.44 6 17KW 25.00 48.00 29.00 471 FG3154-4G 30.56 53.56 4 00 ! - r240_ f-Ti6 0 �l '351.88 7 17KW 25.00 48.00 29.00 431 FG3154-4G 30.56 53.56 4 Ot0 240' 347 c 332.20 8 20KW 25.00 48.00 29.00 451 FG3154-4G 30.56 53.56 4 00 240 35 39f� 342.12 . - t. 9 20KW 25.00 48'00 29.00 516 FG3154-4G 30.56 53.56 4.66 d 240 ^.; rI .�• 38 70 374.09 10 22KW 25.00 88.00 29.00 526 FG3154-4G 30.56 53.56 1 4.00 240 '' 39.20 378.93 1- CONCRETE PADS WEIGHT PROVIDED BY MANUFACTURER, VERIFIED BY OTHERS. :, -•� . - ^ i.,'�'' - 2- FULL THICKNESS OF PADS SHALL BE CONSTRUCTED WITH SOLID PRECAST CONCRETE, MINIMUM COMPRESSIVE STRENGTH Pcy 4,000•PST-AT 28 DAYS 3- ALL OTHER UNITS NOT SHOWN SHALL BE DESIGNED ON A CASE BY CASE BASIS. LARGER CONCRETE PADS MAY BE DESIGNED"PER DIFFERENT EGAD COMBINATIONS. 4- CONTRACTOR SHALT. PROVIDE 5/8' DIA. (0.675- O.D.) GALV. TUBE ASTM A53B SCH 40 MIN. OR 1/2- DIA. SOLID COPPER BAR SPIKE, 4' MIN. EMBED. (ALSO SEE MIN. EMBED. AS PER CURRENT ELECTRICAL CODE, BY OTHERS) INTO GROUND THROUGH CONCRETE PAD FOR SLIDING RESISTANCE PURPOSE, 12 DIAMETERS EDGE DISTANCE FROM ANY CONCRETE FACE (NOT SHOWN) . 1 PRE -FABRICATED GENERATOR PAD DETAIL NO SCALE LANK L BENNARDO, P.E. :✓F 0046549 0. 'r' '�NtavtuwGae[tva r r�'' Fi•WERIAIJI�P.E. .60974 rl I %LID FOR I PZWIT ONL.`ILN.C;'. LID C7;_YWI1H GOdNALLOGAIEER SFIJ ' 4 7I �,�. ,o , • Gm' vJ Lu_ P'I ,.0 W SIi 2:) U Zh l� 1 � V.I IIVI _(Nia ' ~> KLu M. W Q a W owl7� WN ClI%wLu WU U 0 vi Wx Z. 11� o w w to 0r-i F z O = I --I ww-• o U) o w > 0 aI�3 � O F ^0 a 3 p3m� z g UQ6 a ce o a ='LHW w (n u~i o f a N W LUO H l� u Z 's auk co ci In Ud'N W - Z c'') m wF-LL9 m WQ Qm WTw co ipv~i .I I.- a.2 1° W U -I Jo VJ m m Ice Ho S. O v ID o 0 z V�H W = mw0 a ¢ o wWILL] 2z 00 o uz Oai" j V FHF , yy 3333 Z 8. $ b�g O _j Noloz 0LLI 40 w0°o' W N I- kx B HUT m N Q. o W^w Z COPYRIGHT ENGINEERING EXPRESS 14-1669A SCALE: N.T.S. E3 :,-04/09/2018 30F3