Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNE9 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CHESSER RESIDENCE Builder Name: GEM BUILDERS Street: 1317 LONE PINE LANE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: I Jurisdiction: Design Location: FL, Fort Pierce I County:: St Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) i 9. Wall Types (2788.9 sgfL) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 2678.90 ft2 b. Frame - Wood, Adjacent R=11.0 210.00 fN 3. Number of units, if multiple family 1 c. NIA R= fN 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (2390.0 sgfQ Insulation Area a. Roof Deck (Unvented) R=20.0 2390.00 ft2 6. Conditioned'floor area above grade (ft2) 2392 b. WA R= ft2 Conditioned floor area below grade (ft?) 0 c. R= ft' i 11. Ducts R ft2 7. Windows(518.1 sgft.) Description Area j a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 170 a. U-Factor: Sgl, U=0.65 518.08 ft- SHGC: SHGC=0.25 b. U-Factor: NIA ft' 12. Cooling systems kBtulhr Efficiency SHGC: a. Central Unit 41.0 SEER:16.00 c. U-Factor: NIA ft. SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: NIA ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (2392.0. sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab-OrrGrade Edge Insulation R=0.0 2392.00 ft2 b. Conservation features EF: 0.980 b. WA R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 85.17 Glass/Floor Area:: 0.217 a A �7 rMS c Total Baseline Loads: 85.19 I hereby certify that the plans and specifications covered by Review of the plans and �I1E this calculation are in compliance with the Florida Energy specifications covered by this �y�� rO� Code. I calculation indicates compliance with the Florida Energy Code. & y EP E BY: Before construction is completed DATE: i this building will be inspected for t"; compliance with Section 553.908 I hereby certify that this b ' i , as esigned, is in compliance Florida Statutes. f�, �S- Florida Energy G'Op Wt. OWNER/A BUILDING OFFICIAL: E: DATE: fittion by the air handle - Compliance requires cer unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation. Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). 312J2018 10:23 AM EnergyGsuge® USA - FlaRes2017 Section R405A.1 Compliant Software Page 1 of 6 F(�42M "Rd05-2(117 PROJECT Tltle: CHESSER,RESIDENCE Bedrooms: r 3 Address Type: Street Address 'Building Type: User Conditioned Area: 2392 Lot # Owner Name: Total Stories: i 1 Block.subdh4sion: # of Units: 1 Worst Case: No PlatBook: Builder Name: GEM' BUILDERS Rotate Angle: 0 Street: 1317 'LONE PINE LAN Permit Office: ST LUCIE COUNTY Cross Ventilati on: No County,: St. Lucia - Jurisdiction, W hole Hause Fah: No City, State,, Zip: FORT PIERCE, Family Type: Single-family FL, NewlE Asting: New (From Plans) Comment: CLIMATE _ / Deslgri Temp tnt Design Temp Heating Design Daily Temp V Design Location TMY.Site I 97.5 % , 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce ..FL VEROBEACH_MUNI I 39 90 76 75 299 62 Low BLOCKS Number- : Name Area Volume . 1 Entire.House 2392 24912 !SPACES Number, Name Area .Volume. Kitchen Occupants Bedrooms Infil ID Finished Coaled Heated 1 MASTER BEDROO. 377 4147 No 0 1. 1 Yes Yes Yes. 2 M WIC 1 72 720 'No . 0 1 Yes Yes Yes 3 M-WIC 2 42 420. INo �No 0 1 Yes Yes Yes 4 M TOILET 24 240 0 1 Yes Yes Yes 5 MASTER BATH 18.2 1820 lNo 0 1 Yes Yes, Yes 6 LIVING ROOM 271 2961 I No 0 1 Yes :Yes Yes 7 FOYER 48 480 ! No 0 1 Yes Yes Yes 8 DINING ROOM 13.8 13..80 I No 0 1: Yes Yes 'Yes 9 LAUNDRY 104 1040 I No 1 0 1 Yes Yes Yes 10 HALLWAY 77 770 No 0 1 Yes Yes Yes 11. KITCHEN 183 1830 Yes 0 1 'Yes Yes Yes 12 NOOK 128 1260 No 0 1 Yes Yes Yes 13 FAMILY ROOM 344 3784 j No 0 1 Yes . Yes Yes 14 BEDROOM 3 156 156.01 No 0 1 1 Yes Yes Yes 15 CLST 3 20 206 ! No 0 1 Yes Yes Yes 16 BATH 2 60 600 No 0 1 Yes Yes Yes 17 BEDROOM 152 1520 No 0 1 1 Yes Yes. Yes 18 CLST 2 16 160 i No 0 1 Yes Yes Yes I i i 3121201810:23 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 i I Gn1�me Ranj;.gn17 FLOORS i # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 48 ft 0 317 ft' --- 1 0 0 2 Slab -On -Grade Edge Insulation M W IC 1 12 ft 0 72 ft' _.e 1 0 .0 3 Slab -On -Grade Edge Insulation M W IC 2 1 it 0 42 ft' — 1 0 0 4 Slab -On -Grade Edge Insulation M TOILET 7 ft 0 24 ft2 1 0 0 5 SIab-On-Grade Edge Insulation MASTER BATH 38A 0 182 ft2 -_-_ 6 Slab -On -Grade Edge Insulation LIVING ROOM lift 0 271 ft' ____ 1 0 0 7 Slab -On -Grade Edge Insulation FOYER 8 ft 0 48 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation DINING ROOM 1.4.9 ft 0 138 ft2 .._. 1 0 0 9 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0 104 ft2 __ 1 0 0 10SIab-On-Grade Edge Insulation HALLWAY 1 ft I i 0 77 ft' ___ 1 0 0 11SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 183 ft2 _^ 1 0 0 12SIab-On-Grade Edge Insulation NOOK 25 it 0 126 112 — 1 0 0 13SIab-On-Grade Edge Insulation FAMILY ROOM 49 ft 0 344 ft2 1 0 0 14SIab-On-Grade:Edge Insulation BEDROOM,3 12 ft 1 0 156 ft2 .... 1 0 0 15SIab-On-Grade Edge Insulation CLST 3 2 ft 0 20 ft2 __-_ 1 0 0 16SIab-On-Grade Edge Insulation BATH 2 6 ft 0 60 ft2 _._. 1 0 0 17SIab-On-Grade Edge -Insulation BEDROOM 2 12 ft i 0 152 ft2 __ 1 0 0 18SIab-On-Grade Edge Insulation CLST 2 1 ft i 0 16 ft2 ---_ 1 0 0 ROOF Roof I Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2675 ft2 0 W Light 0.6 No 0.9 No 20 26.6 j ATTIC JType 'Vent . Ventilation Ratlo (1 in) Area RBS IRCC 1 full attic Unvented 0 2392 ft2 N N 30201810:23 AM EnergyGauge® USA- FtaRes2017 Section R405A.1 Compliant Software Page 3 of 6 FOAM R405-2017 CEILING V Ceiling Type Space. R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO i20 Blown 377 ft2 0.1 Wood 2 Under Attic (Unvented) M WIC 1 20 Blown 72 ft2 0.1 Wood 3 Under Attic (Unvented) 'M WIC 2 20 Blown 42 ft2 0.1 Wood 4 Under Attic (Unvented) M TOILET ;20 Blown 24 ft' 0.1 Wood 5 Under Attic (Unvented) MASTER BATH 20 Blown 182 ft2 0.1 Wood 6 Under Attic(Unvented) LIVING ROOM 120 Blown 271 ft' 0.1 Wood 7 Under Attic (Unvented) FOYER 20 Blown 48 ft' 0.1 Wood B Under Attic (Unvented) DINING ROOM 20 Blown 138ft2 0.1 Wood 9 UnderAttic (Unvented) LAUNDRY 20 Blown 104 ft2 0.1 Wood 10 Under Attic (Unvented) HALLWAY 20 Blown 77 ft2 0.1 Wood 11 Under Attic (Unvented) KITCHEN 20 Blown 183 ft2 0.1 Wood 12 Under Attic (Unvented) NOOK 120 Blown 126 ft2 0.1 Wood 13 Under Attic (Unvented) FAMILY ROOM 20 Blown 342 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 3 20 Blown 156 if 0.1 Wood 15 Under Attic (Unvented) CLST 3 20 Blown 20 ft2 0.1 Wood 16 Under Attic (Unvented) BATH 2 20 Blown 6b ft2 0.1 Wood 17 Under Attic (Unvented) BEDROOM 2 20 Blown 152 ftx 0.1 Wood 18 Under Attic (Unvented) CLST 2 20 Blown 16 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block - Ext InsWASTER BE 4.1 24 0 11 0 264.0 ft' 0 0 0.6 0 2 S Exterior Concrete Block - Ext InsMASTER BE 4.1 10 0 11 0 ' 110.0 ft2 0 0 0.6 0 3 SW Exterior Concrete Block - Ext InsWASTER BE 4.1 7 1 11 0 77.9 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Ext Ins MASTER BE 4.1 7 0 11 0 77.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block-Ext Insul M WIC 1 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 6 W Exterior Concrete Block - Ext Insul M WIG 2 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block - Ext InsulM TOILET 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 _ 8 S Exterior Concrete Block- Ext InsuiM TOILET 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0 _ 9 N Exterior Concrete Block - Ext InsdMASTER BA 4.1 16 0 10 0 160.0 ft' 0 0 0.6 0 _ 10 E Exterior Concrete Block - Ext InsLMASTER BA 4.1 8 0 10 0 80.0 ft2 0 0 0A 0 11 W Exterior Concrete Block - Ext InsdMASTER BA 4.1 14 0 10 0 140.0 f1:2 0 0 0.6 0 12 S Exterior Concrete Block - Ext InsBIIVING ROO 4.1 11 0 11 0 121.0 ft2 0 0 0.6 0 _ 13 N Exterior Concrete Block - Ext.lnsul FOYER 4.1 8 0 10 0 80.0 tt2 0 0 0.6 0 14 N Exterior Concrete Block - Ext InsDINING ROO ;4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 15 E Exterior Concrete.Block - Ext InsMINING ROO 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 16 E Exterior Concrete Block - Ext InsuILAUNDRY 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0 _ 17 E Exterior Concrete Block - Ext Insui NOOK 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 18 S Exterior Concrete Block- Ext Insul NOOK 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 19 E Exterior Concrete Block- Ext Ins&IAMILY ROO i4.1 12 0 11 0 132.0 ft2 0 0 0.6 0 20 S Exterior Concrete Block - Ext Ins61AMiLY ROO :4.1 19 0 11 0 209.0 ft2 0 0 0.6 0 21 W Exterior Concrete Block - Ext InsfiLAMILY ROO 4.1 18 0 1.1 0 198.0 ft2 0 0 0.6 0 22 W Exterior Concrete Block- Ext Ins6EDROOM 3 .4.1 12 0 10 0 120.0 W 0 0 0.6 0 3/212018 10:23 AM EnergyGauge@ USA -. FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FnRM R41)5-2017 WALLS I. Adjacent Cavl{ Width Height Sheathing Framing Solar Below Space 23 W Exterior Concrete Block - Ext Insul CLST 3 4A 2 0 10 0 20.0 ft2 0 0 0.6 0 24 W Exterior Concrete Block - Ext Insul BATH 2 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 25 W Exterior Concrete Block - Ext InsaEDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 26 N. Garage Frame -Wood . BEDROOM 2 11. 21 10 210.0 ft2 0 0 0.600000 0 WINDOWS Orientation shown Is the entered, Proposed orientation - V Wall I Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth _ Separation Int Shade Screening. 1 E 1 Metal Low-E Single Yes 0.65 0.25 N 16.0 ft2 2 ft 0 in 1 ft4 in None None 2 S 2 Metal Low-E Single Yes I 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 3 SW 3 Metal Low-E Single 'Yes 0.65 0:25 N 47.3 ft2 2 ft 0 in 1 ft 4 in None None 4 W 4 Metal Low-E Single Yes 0.65 0.26 N 15.0 ft2 2 ft 0 In 1 ft 4 in None None 5 E 7 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 6 N 9 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 In 1 ft 4 in None None 7 S 12 Metal Low-E Single Yes 0.65 0.25 N 72.0 ft2 2 ft 0 in 1 ft 4 in None None 8 N 13 Metal Low-E Single Yes I 0.65 0.25 N 48.0 ft2 2 ft 0 in 1 ft 4 in None None 9 N 14 Metal Low-E Single Yes i 0.65 0.25 N 24.0 ft2 2 ft 0 in 1 ft 4 in. None None 10 N 14 Metal Low-E Single Yes 0.65 0.26 N 24.0 ft2 '2 ft 0 in 1 ft 4 in None None 11 E 17 Metal Low-E Single Yes I 0.65 0.26 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 12 E 17 Metal Low-E Single Yes 0.66 0.25 N 21.3 ft2 2 ft 0 in 1 ft 4 in None None 13 S 18 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 In None None 14 S 18 Metal Low-E Single Yes 0.65 0.25 N 20.4 ft2 2 ft 0 in 1 ft 4 in None None 15 E 19 Metal Low-E Single Yes I 0.65 0.25 N 64.0 112 2 ft 0 in 1 ft 4 in None None 16 S 20 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 17 W 21 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 18 W 22 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 19 W 24 Metal Low-E Single Yes 0165 0.25 N 8.0 ft2 2 ft 0 in 1 ft4 in None None 20 W 25 Metal Low-E Single Yes 0;65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wail Insulation 1 625 ft2 625 ft2 21 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 RA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000463 2906.4 159.56 300.01 .3382 7 3/2/2018 10:23 AAA EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 Gr)PKA QAnr—,qn17 HEATING SYSTEM #' System Type Subtype Efficlency Capacity Block Ducts' 1 Electric Strip Heat/ None C0P:1 27 kBtuthr 1 sys#1 COOLING SYSTEM System Type Subtype. Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit, Split i SEER:16 41 kBtulhr 1230 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type . 'SubT.ype Location EF i Cep Use . '.. SetPnt Conservation . 1 Electric None Garage 0.98 i it... 40 gal 60.9 gal 120'deg None SOLAR HQ , WATER'SYSTEM _ .. FSEC, Collector Storage Cert # Company Name System Models# Collector Model # .Area, r Volume FEF None None . ft2 bUCTS — Supply-- — Return— Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area 1 Leakage Type Handler ° TOT"' OUT ON RLF Heat Cool 1 • Attic , 6 170 ft' Attic 17 ft= ;Default Leakage .LAUNDRY (Default) c(Default) c TENIERATURES Programable Thermostat: •N Ceiling Fans Cooling Jan Feb j j Mar Heatin: Jan [X] Feb [)C) Mar [ j Apr [ jj May n Jun Jul (],Apr. [ ]May I ]Jun Jul . nAug Piu9, n Sep [ j Se� [ 10ct Oct [ ] Nov [X] Nov H Dec Dec Ventin Jan j[ ]] Feb [X] Mar [XJ A r [) Ma [ ]Jun Jul Au Se [Jq Oct [XI Nov Dec . ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3• 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78.1 78 78 78 78 80 80 80 80 'PM 80 80 80 80 1 78 78 78 78 78 78 78 78 .Cooling (WEH) AM78 '78 78, 78 I 78 78 a 78 78 80 80 80 80 PM 80 80 80 80 78 78. 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 , 65 65 65 ' 68 68 .68 68 68 PM 68 68 68 68 68 68 68 88 68 68 68 68, Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 .68 .. 68 68 1 68 68 68 68 68 ' 68. 68 68, 312/201810:23 AM EnergyGauge@ USA - RaRes2017 Section. R405:4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA is • Project Name: CHESSER RESIDENCE Builder Name: GEM BUILDERS Street. 1317 LONE PINE LANE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number. Owner. Jurisdiction: Design Location: FL, Fart Pierce COMPONENT i AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed In the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffft shall be aligned with the insulation and any gaps in the air barrier shall bei sealed. The Insulation In any dropped celling/soffit shall be aligned with the air barrier.: Access openings,. drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shalllbe sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and ,and doors skylights and'framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of abov"arage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered. with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped: shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts 'opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities. shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage.And conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be,sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring.. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed, behind electrical or communication exterior walls boxes or airvsealed boxes shall be installed. ' HVAC register boots HVAC register boots that penetrate building thermal, envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. a. In acaition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/21261810:24 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more. efficient the home. 1317 LONE PINE LANE, FORT PIERCE, .FL, 1. New construction or erasting New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 2578.90 ft2 b. Frame -Wood, Adjacent R=11.0 210.00 ft2 3. Number of units, if multiple family 1 Q. NIA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Roof.Deck (Unvented) R=20.0 2390:00 ft2 6. Conditioned floor area (ft2) 2392 b. N/A R= ft2 7. Windows— Description Area c. N/A R= ft2 a. U=Factor. Sgl, U=0.65 518.08 ft2 11, Ducts R ft2 a. Sup: Attic, Rat Attic, AH: LAUNDRY 6 170 SHGC: SHGC=0;25 b. U-Factor: N/A ft2 SHGC: 12, Cooling systems kBtu/hr Efficiency c. U-Factor. NIA ft2 a. Central Unit 41.0 SEER:16.00 SHGC: d. U-Factor: NIA ft2 j 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 2'000 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems i Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2392.00 W a. Electric b. NIA R ft2 EF: 0.98 c. NIA R= ft2 b. Conservation features None 15. Credits None I certify th this home, has o; plied with the Florida Energy Efficiency Code for Building % stru ion through the ab v energy saving features which will be installed (o' exce ded) ,yo Fc in this me before final ins tion. Otherwise, a new EPLIDisplay Card will b com leted 58d O I CO p features. +, Builder Si ature: / Address of New Home: i� CityIFL Z' : I y" QOD We *Note: This is not a Building nergy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@enefgygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/21201810:23 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1