HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNE9
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CHESSER RESIDENCE
Builder Name: GEM BUILDERS
Street: 1317 LONE PINE LANE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
I
Jurisdiction:
Design Location: FL, Fort Pierce I
County:: St Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans) i
9. Wall Types (2788.9 sgfL)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Ext Insul, Exterior
R=4.1 2678.90 ft2
b. Frame - Wood, Adjacent
R=11.0 210.00 fN
3. Number of units, if multiple family 1
c. NIA
R= fN
4. Number of Bedrooms 3
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (2390.0 sgfQ
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2390.00 ft2
6. Conditioned'floor area above grade (ft2) 2392
b. WA
R= ft2
Conditioned floor area below grade (ft?) 0
c.
R= ft'
i
11. Ducts
R ft2
7. Windows(518.1 sgft.) Description Area j
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 170
a. U-Factor: Sgl, U=0.65 518.08 ft-
SHGC: SHGC=0.25
b. U-Factor: NIA ft'
12. Cooling systems
kBtulhr Efficiency
SHGC:
a. Central Unit
41.0 SEER:16.00
c. U-Factor: NIA ft.
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor: NIA ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (2392.0. sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab-OrrGrade Edge Insulation R=0.0 2392.00 ft2
b. Conservation features
EF: 0.980
b. WA R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 85.17
Glass/Floor Area:: 0.217
a A �7
rMS c
Total Baseline Loads: 85.19
I hereby certify that the plans and specifications covered by
Review of the plans and
�I1E
this calculation are in compliance with the Florida Energy
specifications covered by this
�y�� rO�
Code. I
calculation indicates compliance
with the Florida Energy Code.
& y
EP E BY:
Before construction is completed
DATE: i
this building will be inspected for
t";
compliance with Section 553.908
I hereby certify that this b ' i , as esigned, is in compliance
Florida Statutes.
f�, �S-
Florida Energy
G'Op Wt.
OWNER/A
BUILDING OFFICIAL:
E:
DATE:
fittion by the air handle - Compliance requires cer unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation. Inspection Checklist In accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
312J2018 10:23 AM EnergyGsuge® USA - FlaRes2017 Section R405A.1 Compliant Software Page 1 of 6
F(�42M "Rd05-2(117
PROJECT
Tltle:
CHESSER,RESIDENCE
Bedrooms: r
3
Address Type:
Street Address
'Building Type:
User
Conditioned Area:
2392
Lot #
Owner Name:
Total Stories: i
1
Block.subdh4sion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
GEM' BUILDERS
Rotate Angle:
0
Street:
1317 'LONE PINE LAN
Permit Office:
ST LUCIE COUNTY
Cross Ventilati on:
No
County,:
St. Lucia -
Jurisdiction,
W hole Hause Fah:
No
City, State,, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
NewlE Asting:
New (From Plans)
Comment:
CLIMATE
_
/
Deslgri Temp
tnt Design Temp
Heating
Design Daily Temp
V Design Location
TMY.Site
I
97.5 % ,
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce ..FL VEROBEACH_MUNI I
39
90
76
75
299
62
Low
BLOCKS
Number- :
Name
Area
Volume .
1
Entire.House
2392
24912
!SPACES
Number,
Name
Area .Volume. Kitchen
Occupants
Bedrooms
Infil ID
Finished Coaled
Heated
1
MASTER BEDROO.
377
4147 No
0
1.
1
Yes
Yes
Yes.
2
M WIC 1
72
720 'No .
0
1
Yes
Yes
Yes
3
M-WIC 2
42
420. INo
�No
0
1
Yes
Yes
Yes
4
M TOILET
24
240
0
1
Yes
Yes
Yes
5
MASTER BATH
18.2
1820 lNo
0
1
Yes
Yes,
Yes
6
LIVING ROOM
271
2961 I No
0
1
Yes
:Yes
Yes
7
FOYER
48
480 ! No
0
1
Yes
Yes
Yes
8
DINING ROOM
13.8
13..80 I No
0
1:
Yes
Yes
'Yes
9
LAUNDRY
104
1040 I No
1
0
1
Yes
Yes
Yes
10
HALLWAY
77
770 No
0
1
Yes
Yes
Yes
11.
KITCHEN
183
1830 Yes
0
1
'Yes
Yes
Yes
12
NOOK
128
1260 No
0
1
Yes
Yes
Yes
13
FAMILY ROOM
344
3784 j No
0
1
Yes .
Yes
Yes
14
BEDROOM 3
156
156.01 No
0
1
1
Yes
Yes
Yes
15
CLST 3
20
206 ! No
0
1
Yes
Yes
Yes
16
BATH 2
60
600 No
0
1
Yes
Yes
Yes
17
BEDROOM
152
1520 No
0
1
1
Yes
Yes.
Yes
18
CLST 2
16
160 i No
0
1
Yes
Yes
Yes
I
i
i
3121201810:23 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
i
I
Gn1�me Ranj;.gn17
FLOORS
i
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO 48 ft
0
317 ft'
---
1
0
0
2 Slab -On -Grade Edge Insulation
M W IC 1
12 ft
0
72 ft'
_.e
1
0
.0
3 Slab -On -Grade Edge Insulation
M W IC 2
1 it
0
42 ft'
—
1
0
0
4 Slab -On -Grade Edge Insulation
M TOILET
7 ft
0
24 ft2
1
0
0
5 SIab-On-Grade Edge Insulation
MASTER BATH
38A
0
182 ft2
-_-_
6 Slab -On -Grade Edge Insulation
LIVING ROOM
lift
0
271 ft'
____
1
0
0
7 Slab -On -Grade Edge Insulation
FOYER
8 ft
0
48 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation
DINING ROOM
1.4.9 ft
0
138 ft2
.._.
1
0
0
9 Slab -On -Grade Edge Insulation
LAUNDRY
1 ft
0
104 ft2
__
1
0
0
10SIab-On-Grade Edge Insulation
HALLWAY
1 ft I
i
0
77 ft'
___
1
0
0
11SIab-On-Grade Edge Insulation
KITCHEN
1 ft
0
183 ft2
_^
1
0
0
12SIab-On-Grade Edge Insulation
NOOK
25 it
0
126 112
—
1
0
0
13SIab-On-Grade Edge Insulation
FAMILY ROOM
49 ft
0
344 ft2
1
0
0
14SIab-On-Grade:Edge Insulation
BEDROOM,3
12 ft 1
0
156 ft2
....
1
0
0
15SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
20 ft2
__-_
1
0
0
16SIab-On-Grade Edge Insulation
BATH 2
6 ft
0
60 ft2
_._.
1
0
0
17SIab-On-Grade Edge -Insulation
BEDROOM 2
12 ft i
0
152 ft2
__
1
0
0
18SIab-On-Grade Edge Insulation
CLST 2
1 ft
i
0
16 ft2
---_
1
0
0
ROOF
Roof I Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
# Type Materials
Area Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Metal 2675 ft2 0 W
Light
0.6
No 0.9
No
20
26.6
j ATTIC
JType
'Vent
.
Ventilation
Ratlo (1
in)
Area
RBS IRCC
1 full attic
Unvented
0
2392 ft2
N N
30201810:23 AM EnergyGauge® USA- FtaRes2017 Section R405A.1 Compliant Software Page 3 of 6
FOAM R405-2017
CEILING
V
Ceiling Type Space.
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) MASTER BEDRO
i20
Blown
377 ft2
0.1
Wood
2
Under Attic (Unvented) M WIC 1
20
Blown
72 ft2
0.1
Wood
3
Under Attic (Unvented) 'M WIC 2
20
Blown
42 ft2
0.1
Wood
4
Under Attic (Unvented) M TOILET
;20
Blown
24 ft'
0.1
Wood
5
Under Attic (Unvented) MASTER BATH
20
Blown
182 ft2
0.1
Wood
6
Under Attic(Unvented) LIVING ROOM
120
Blown
271 ft'
0.1
Wood
7
Under Attic (Unvented) FOYER
20
Blown
48 ft'
0.1
Wood
B
Under Attic (Unvented) DINING ROOM
20
Blown
138ft2
0.1
Wood
9
UnderAttic (Unvented) LAUNDRY
20
Blown
104 ft2
0.1
Wood
10
Under Attic (Unvented) HALLWAY
20
Blown
77 ft2
0.1
Wood
11
Under Attic (Unvented) KITCHEN
20
Blown
183 ft2
0.1
Wood
12
Under Attic (Unvented) NOOK
120
Blown
126 ft2
0.1
Wood
13
Under Attic (Unvented) FAMILY ROOM
20
Blown
342 ft2
0.1
Wood
14
Under Attic (Unvented) BEDROOM 3
20
Blown
156 if
0.1
Wood
15
Under Attic (Unvented) CLST 3
20
Blown
20 ft2
0.1
Wood
16
Under Attic (Unvented) BATH 2
20
Blown
6b ft2
0.1
Wood
17
Under Attic (Unvented) BEDROOM 2
20
Blown
152 ftx
0.1
Wood
18
Under Attic (Unvented) CLST 2
20
Blown
16 ft2
0.1
Wood
WALLS
Adjacent Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
1
E
Exterior Concrete Block - Ext InsWASTER BE
4.1
24
0 11
0
264.0 ft'
0
0
0.6
0
2
S
Exterior Concrete Block - Ext InsMASTER BE
4.1
10
0 11
0
' 110.0 ft2
0
0
0.6
0
3
SW
Exterior Concrete Block - Ext InsWASTER BE
4.1
7
1 11
0
77.9 ft2
0
0
0.6
0
4
W
Exterior Concrete Block - Ext Ins MASTER BE
4.1
7
0 11
0
77.0 ft2
0
0
0.6
0
5
E
Exterior Concrete Block-Ext Insul M WIC 1
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
6
W
Exterior Concrete Block - Ext Insul M WIG 2
4.1
1
0 10
0
10.0 ft2
0
0
0.6
0
7
E
Exterior Concrete Block - Ext InsulM TOILET
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
_ 8
S
Exterior Concrete Block- Ext InsuiM TOILET
4.1
1
0 10
0
10.0 ft2
0
0
0.6
0
_ 9
N
Exterior Concrete Block - Ext InsdMASTER BA
4.1
16
0 10
0
160.0 ft'
0
0
0.6
0
_ 10
E
Exterior Concrete Block - Ext InsLMASTER BA
4.1
8
0 10
0
80.0 ft2
0
0
0A
0
11
W
Exterior Concrete Block - Ext InsdMASTER BA
4.1
14
0 10
0
140.0 f1:2
0
0
0.6
0
12
S
Exterior Concrete Block - Ext InsBIIVING ROO
4.1
11
0 11
0
121.0 ft2
0
0
0.6
0
_ 13
N
Exterior Concrete Block - Ext.lnsul FOYER
4.1
8
0 10
0
80.0 tt2
0
0
0.6
0
14
N
Exterior Concrete Block - Ext InsDINING ROO
;4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
15
E
Exterior Concrete.Block - Ext InsMINING ROO
4.1
2
0 10
0
20.0 ft2
0
0
0.6
0
16
E
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
1
0 10
0
10.0 ft2
0
0
0.6
0
_ 17
E
Exterior Concrete Block - Ext Insui NOOK
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
18
S
Exterior Concrete Block- Ext Insul NOOK
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
_ 19
E
Exterior Concrete Block- Ext Ins&IAMILY ROO
i4.1
12
0 11
0
132.0 ft2
0
0
0.6
0
20
S
Exterior Concrete Block - Ext Ins61AMiLY ROO
:4.1
19
0 11
0
209.0 ft2
0
0
0.6
0
21
W
Exterior Concrete Block - Ext InsfiLAMILY ROO
4.1
18
0 1.1
0
198.0 ft2
0
0
0.6
0
22
W
Exterior Concrete Block- Ext Ins6EDROOM 3
.4.1
12
0 10
0
120.0 W
0
0
0.6
0
3/212018 10:23 AM EnergyGauge@ USA -. FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
FnRM R41)5-2017
WALLS
I.
Adjacent
Cavl{ Width
Height
Sheathing Framing Solar
Below
Space
23 W
Exterior
Concrete Block - Ext Insul CLST 3
4A 2
0
10 0
20.0 ft2
0
0 0.6
0
24 W
Exterior
Concrete Block - Ext Insul BATH 2
4.1 6
0
10 0
60.0 ft2
0
0 0.6
0
25 W
Exterior
Concrete Block - Ext InsaEDROOM 2 4.1 12
0
10 0
120.0 ft2
0
0 0.6
0
26 N.
Garage
Frame -Wood
. BEDROOM 2 11. 21
10
210.0 ft2
0
0 0.600000 0
WINDOWS
Orientation shown Is the entered, Proposed
orientation -
V
Wall
I
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth _
Separation
Int Shade
Screening.
1
E
1
Metal
Low-E Single
Yes
0.65 0.25
N
16.0 ft2
2 ft 0 in
1 ft4 in
None
None
2
S
2
Metal
Low-E Single
Yes
I
0.65 0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
SW
3
Metal
Low-E Single
'Yes
0.65 0:25
N
47.3 ft2
2 ft 0 in
1 ft 4 in
None
None
4
W
4
Metal
Low-E Single
Yes
0.65 0.26
N
15.0 ft2
2 ft 0 In
1 ft 4 in
None
None
5
E
7
Metal
Low-E Single
Yes
0.65 0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
N
9
Metal
Low-E Single
Yes
0.65 0.25
N
20.0 ft2
2 ft 0 In
1 ft 4 in
None
None
7
S
12
Metal
Low-E Single
Yes
0.65 0.25
N
72.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
N
13
Metal
Low-E Single
Yes
I
0.65 0.25
N
48.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
N
14
Metal
Low-E Single
Yes
i
0.65 0.25
N
24.0 ft2
2 ft 0 in
1 ft 4 in.
None
None
10
N
14
Metal
Low-E Single
Yes
0.65 0.26
N
24.0 ft2
'2 ft 0 in
1 ft 4 in
None
None
11
E
17
Metal
Low-E Single
Yes
I
0.65 0.26
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
E
17
Metal
Low-E Single
Yes
0.66 0.25
N
21.3 ft2
2 ft 0 in
1 ft 4 in
None
None
13
S
18
Metal
Low-E Single
Yes
0.65 0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 In
None
None
14
S
18
Metal
Low-E Single
Yes
0.65 0.25
N
20.4 ft2
2 ft 0 in
1 ft 4 in
None
None
15
E
19
Metal
Low-E Single
Yes
I
0.65 0.25
N
64.0 112
2 ft 0 in
1 ft 4 in
None
None
16
S
20
Metal
Low-E Single
Yes
0.65 0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
17
W
21
Metal
Low-E Single
Yes
0.65 0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
18
W
22
Metal
Low-E Single
Yes
0.65 0.25
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
19
W
24
Metal
Low-E Single
Yes
0165 0.25
N
8.0 ft2
2 ft 0 in
1 ft4 in
None
None
20
W
25
Metal
Low-E Single
Yes
0;65 0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
I GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wail Insulation
1
625 ft2
625 ft2
21 ft
loft
11
INFILTRATION
# Scope
Method
SLA CFM 50 RA
EgLA
ACH
ACH 50
1 Wholehouse
ProposedACH(50)
.000463
2906.4 159.56
300.01
.3382
7
3/2/2018 10:23 AAA EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
Gr)PKA QAnr—,qn17
HEATING
SYSTEM
#' System Type
Subtype
Efficlency
Capacity
Block
Ducts'
1 Electric Strip Heat/
None C0P:1
27 kBtuthr
1
sys#1
COOLING SYSTEM
System Type
Subtype. Efficiency
Capacity
Air Flow SHR
Block
Ducts
1 Central Unit,
Split i SEER:16
41 kBtulhr
1230 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type . 'SubT.ype
Location EF i
Cep
Use . '..
SetPnt
Conservation
.
1 Electric None
Garage 0.98 i
it...
40 gal 60.9 gal
120'deg
None
SOLAR HQ ,
WATER'SYSTEM
_
..
FSEC,
Collector
Storage
Cert # Company Name
System Models# Collector Model # .Area,
r
Volume
FEF
None None .
ft2
bUCTS
— Supply--
— Return—
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location Area 1 Leakage Type
Handler
° TOT"' OUT
ON
RLF
Heat Cool
1 • Attic , 6 170 ft'
Attic 17 ft= ;Default Leakage
.LAUNDRY (Default) c(Default) c
TENIERATURES
Programable Thermostat: •N
Ceiling Fans
Cooling Jan Feb j j Mar
Heatin: Jan [X] Feb [)C) Mar
[ j Apr [ jj May n Jun Jul
(],Apr. [ ]May I ]Jun Jul .
nAug
Piu9,
n Sep [ j
Se� [ 10ct
Oct
[ ] Nov
[X] Nov
H Dec
Dec
Ventin Jan j[ ]] Feb [X] Mar
[XJ A r [) Ma [ ]Jun Jul
Au
Se [Jq
Oct
[XI Nov
Dec .
ThermostatSchedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3• 4 5 6
7
8 9
10
11
12
Cooling (WD) AM 78
78 78 78.1 78 78
78
78 80
80
80
80
'PM 80
80 80 80 1 78 78
78
78 78
78
78
78
.Cooling (WEH) AM78
'78 78, 78 I 78 78
a
78
78 80
80
80
80
PM 80
80 80 80 78 78.
78
78 78
78
78
78
Heating(WD) AM 65
65 65 65 , 65 65
65 '
68 68
.68
68
68
PM 68
68 68 68 68 68
68
88 68
68
68
68,
Heating(WEH) AM 65
65 65 65 65 65
65
68 68
68
68
68
PM 68 .68
.. 68 68 1 68 68
68
68 68 '
68.
68
68,
312/201810:23 AM EnergyGauge@ USA - RaRes2017 Section. R405:4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
is •
Project Name: CHESSER RESIDENCE Builder Name: GEM BUILDERS
Street. 1317 LONE PINE LANE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number.
Owner. Jurisdiction:
Design Location: FL, Fart Pierce
COMPONENT
i
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed In the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffft shall be aligned with the
insulation and any gaps in the air barrier shall bei sealed.
The Insulation In any dropped celling/soffit
shall be aligned with the air barrier.:
Access openings,. drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shalllbe sealed.
Cavities within corners and headers of frame walls shall
The junction of the top plate and the top of exterior walls shall be sealed.
be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
,and doors
skylights and'framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
abov"arage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered. with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped:
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts 'opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities. shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on Installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage.And conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be,sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring..
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed, behind electrical or communication
exterior walls
boxes or airvsealed boxes shall be installed. '
HVAC register boots
HVAC register boots that penetrate building thermal, envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Plates and walls or ceilings.
a. In acaition, inspection of log walls shall be in accordance with the provisions of ICC-400.
3/21261810:24 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more. efficient the home.
1317 LONE PINE LANE, FORT PIERCE, .FL,
1. New construction or erasting New (From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 2578.90 ft2
b. Frame -Wood, Adjacent R=11.0 210.00 ft2
3. Number of units, if multiple family 1 Q. NIA R= ft2
4. Number of Bedrooms 3 d. N/A R= ft2
5. Is this a worst case? No 10. Ceiling Types Insulation Area
a. Roof.Deck (Unvented) R=20.0 2390:00 ft2
6. Conditioned floor area (ft2) 2392 b. N/A R= ft2
7. Windows— Description Area c. N/A R= ft2
a. U=Factor. Sgl, U=0.65 518.08 ft2 11, Ducts R ft2
a. Sup: Attic, Rat Attic, AH: LAUNDRY 6 170
SHGC: SHGC=0;25
b. U-Factor: N/A ft2
SHGC: 12, Cooling systems kBtu/hr Efficiency
c. U-Factor. NIA ft2 a. Central Unit 41.0 SEER:16.00
SHGC:
d. U-Factor: NIA ft2 j 13. Heating systems kBtu/hr Efficiency
SHGC: a. Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 2'000 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14. Hot water systems
i Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2392.00 W a. Electric
b. NIA R ft2 EF: 0.98
c. NIA R= ft2 b. Conservation features
None
15. Credits None
I certify th this home, has o; plied with the Florida Energy Efficiency Code for Building %
stru ion through the ab v energy saving features which will be installed (o' exce ded) ,yo Fc
in this me before final ins tion. Otherwise, a new EPLIDisplay Card will b com leted
58d O I CO p features.
+,
Builder Si ature: /
Address of New Home: i� CityIFL Z' : I y"
QOD We
*Note: This is not a Building nergy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@enefgygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/21201810:23 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1