Loading...
HomeMy WebLinkAboutTRUSSESCD its 0 in M 1' CJ3 CJ1 4' 0" 7' Koh Vol 8' 8" 16' 8"/ LO ih 5' 2" 38' 8" 161611 11' 4" o � r = 19' 8" 3, 0 fV 0" l 2' 0" r V05 0 iaa VO4 - V03 ih ifl "v ih r 03' 8" 111811 4' 0" 8' 0" 14' 0" 22' 0" 031811 a AHU 2' 4" 10'-0" CLNG 2' 4" E01 VA 4' 0" 13' 6" ®_-ffJ-7 o o uo Hatch Legend j10'-0" ,4. F. F TRUSS END DETAIL SQUARE CUT OVERHANG 12 w/2x4 LEVEL RETURNS 6 4-3/16" HEEL HEIGHT 3'-1 /2" 1l2' / 2 0 / J7 -- ----------- —--- -------------- -- J7 0 M_ a V02 a N N T S 25' 0" C09 ATTIC 03 0 STORAGEGE N V-4" OVERHANG CAUTION!!! DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-131 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (ie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE. 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders FirstSource. NO EXCEPTIONS. The General Contractor Is Responsible �p�� 0341i For All Connections Other Than Truss ST. LUCI OUNTY BUIL ING DIVISION to Truss, Gable Shear Wall, And REVIEWED FOR COMPL CE Connections. Temporary and REVIEDATE WED v Permanent Bracing, And Ceiling And PLANS A D PERMIT VST BE KEPT ON JC 3 Roof Diaphragm Connections. SITE OR NO INSPECTION(S) WILL BE MAIII E 'ONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CO •lTRAC T OR OF RECORD. SCi/�n( srtroPo�(,, HANGER LEGEND * ALL 2x HANGERS SHOWN ARE HTU26 UNLESS NOTED OTHERWISE * • ALL 4x2 FLOOR HANGERS SHOWN ARE HHUS46 U'vLESS NOTED OTHERWISE I MAIN WIND FORCE RESISTING SYSTEMIC-C HYBRID IMPORTANT WIND ASCE7-10 ENCLOSED This Drawing Must Be Approved And EXPOSURE CATEGORY C Returned Before Fabrication Will OCCUPANCY CATEGORY II Begin. For Your Protection Check All WIND LOAD 170 MPH Dimensions And Conditions Prior To *TRUSSES HAVE BEEN DESIGNED FORA 10.0 PSF Approval Of Plan. BOTTOM CHORD LIVE LOAD NONCONCURRENT WITH ANY OTHER LIVE LOADS SIGNATURE BELOW INDICATES ALL NOTES AND DIMENSIONS HAVE ROOF LOADING FLOOR LOADING BEEN ACCEPTED. TCLL: 20 PSF TOLL: PSF TCDL: 07 PSF TCDL: PSF BCDL: 10 PSF BCDL: PSF By Date TOTAL: 37 PSF TOTAL: PSF DURATION: 1.25 DURATION: BUILDER: GEM BLDRS RES: CHESSER MODEL: N/A ADDRESS: 1317 LONE PINE DRIVE LOT / BLOCK: -- CITY: FORT PIECE COUNTY ST LUCIE CO DRAWN BY: JL JOB # : 1377009 DATE: 03/24/18 SCALE: NTS REVISIONS: 1. 2. 3. 4. 701 S. KINGS HIGHWAY FORT PIECE, FL 34945 Ph. (772) - 461 5475