HomeMy WebLinkAboutEVALUATION REPORT® , f \ SCANN ED _ 66V j EXTERIOR RESEARCH & DESIGN, I.I.C. �",-,,FTRINITY' Certificate of Authorization #9503 353 Christian Street ER® Oxford, CT 06478 (203) 262-9245 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P9290.02.08-1120 150 Lyon Drive FL1654-1122 Fernley, NV 89408 Date of Issuance: 02/11/2008 (S70) 384-1230 Revision 20: 09/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) FlI orida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of t e Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 58-page Appendix. Prepared by: `,R'�ttt`tlttr„ter! Robert J.M. Nieminen, P.E. ,✓,,r11h���iq>>`�~°' The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No. 59166, Florida DCA ANE1983 F.E. on 09/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: ! 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a,Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have norjwill acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. ! 5. This is a building code evaluation. Neither Trinity[ ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, for previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: I 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance withlthe following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use iset forth herein. STANDARDS: Section 1504.3.1 1504.3.1 1504.7 1507.11.2 1507.11.2 1507.11.2 1507.11.2 1507.11.2 3. REFERENCES: Entity ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD(TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD(TST11294) Exterior Research and Design; I.I.C. Certificate of Authorization #9503 I Properties I Properties I Properties I Properties I Properties I Properties Properties Properties Properties Properties Properties Properties Properties al Properties al Properties al Properties 70/4474 al Properties al Properties Physical Properties FM 4470/4474 FM4470/4474 FM 4470/4474 FM 4470/4474 U L 1897 FM 4470/4474 FM 4470/4474/UL1897 FM 474/UL1897/TAS 114 FM �474/UL1897/TAS 114 Standard FM 4474 UL 1897 FM 4470 ASTM D6162 ASTM D6163 ASTM D6164 ASTM D6222 ASTM D6509 Reference P10490.10.08-2 P13760.09.09 P13770.09.09 P30540.11.09-R1 P30550.12.09 P33960.12.10 P33970.03.11 P37590.03.13-3A P39680.03.13 P37590.03.13-1-R1 P37590.03.13-2-R1 P37590.07.13-2 P37590.03.13-5-R1 P37590.07.13-1 P41630.08.13 P45940.09.13 P44370.10.13 P39520.09.14-2 SC6160.11.14 PLYG-P45440SC.03.15-1 SC5170.05.15 SC8085.05.15 SC5170.12.15 SC9455.15 PLYG-SC8905.05.16-1 PLYG-SC8905.05.16-2 PLYG-SC10815.07.16-R1 PLYG-SC12025.10.16 PLYG-SC11475.16 PLYG-SC13235.01.17 PLYG-SC13920.05.17 PLYG-CTL13945.05.17-1 i 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (570) 384-1230 I i I I Year 2011 2012 2012 2008 2008 2011 2011 2009 Date 10/30/2008 09/10/2009 09/10/2009 11/30/2009 12/02/2009 12/30/2010 03/15/2011 03/06/2013 03/04/2013 06/26/2013 07/01/2013 07/01/2013 07/01/2013 07/02/2013 08/06/2013 09/04/2013 10/04/2013 09/11/2014 11/10/2014 03/31/2015 05/08/2015 05/19/2015 12/29/2015 04/01/2016 05/17/2016 05/17/2016 09/23/2016 10/12/2016 11/17/2016 01/17/2017 05/30/2017 05/30/2017 Evaluation Report P9290.02.08-R20 FL1654-R22 Revision 20: 09/12/2017 Page 2 of 6 4. \\JTRINITYIERN, Entity Examination Reference Date ERD(TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL13945.05.17-3 05/30/2017 ERD(TST6049) FM 4474/UL1897 PLYG-SC13945.05.17 05/30/2017 ERD(TST6049) FM 447i4/TAS 114 PLYG-SC15760.09.17 09/11/2017 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 44;70 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals (TST1867) FM 4470/4474 3049631 04/21/2014 FM Approvals (TST1867) FM 4470/4474 3057029 02/02/2017 PRI(TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI(TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST5878) Phys ical Properties PUSA-064-02-02 02/27/2008 'PRI(TST5878) PhyslicalProperties PUSA-062-02-02 12/04/2008 PRI(TST5878) TAS 114 PUSA-188-02-01 02/08/2017 PRI(TST5878) TAS1114 PUSA-188-02-02 02/08/2017 PRI(TST5878) TAS1114 PUSA-188-02-03 02/08/2017 PRI(TST5878) TASI114 PUSA-202-02-01 05/17/2017 PRI(TST5878) TAS 114 PUSA-202-02-02 05/17/2017 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 10-0823 10/12/2010 UL LLC (QUA9625) Quality Control Service Confirmation, R14571 Exp. 10/06/2018 PRODUCT DESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. " TABLE 1 ROLLASOODS>FOR POLYGLASSMODIFIED IBITUMENROOF SYSTEMS Type ! Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A Exterior Research and Design, U.C. Evaluation Report P9290.02.08-R20 Certificate of Authorization tl9503 a EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-1122 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 3 of 6 r I i i T�RINITYJERD aJL u ,TABLE 1(CONTINUEO�, ROLL GOODS FOR POLYGLASS MODIFIED ,.. _.., BITUMEN ROOF SYSTEMS Yp Type i Product Specification Reference Grade Type SBS Membranes Polyglass HT Base 650 ASTM D6162 S III Elastob'ase ASTM D6163 S I Elastoflex V - ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 Type II ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I SBS Membranes Elasto,,'flex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS (sand or poly -film backed) ASTM D6164 G I Polyfresko G SBS FR (sand or poly -film backed) ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Palyreflect ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S I S. LIMITATIONS: 5.1 This is a building code! evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any 'way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design Iguidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unlessithe exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in ;accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. i i Exterior Research and Design, I.I.C. Evaluation Report 139290.02.08-1120 Certificate of Authorization #9503 6- EDITION (2017) FBC NON-HVHZ EVALUATION F1.1654-1122 i Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 4 of 6 I I � I TR1N111Y ER® 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29! Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-291(January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application!Standard TAS 105. 1 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or (membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and testedifor resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 1 I 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 611320-3. I 6. INSTALLATION: 6.1 Polyglass Modified Bitumeln Roof Systems shall be installed in accordance with Polyglass UISA;Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. I I I I I Exterior Research and Design, I.I.C. i Evaluation Report P9290.02.08-R20 Certificate of Authorization #9503 1 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-1122 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 5 of 6 7. 8. 9. \ ",�TRINITYJERD 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non-Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; ➢ PG700QS (Quick -Set.) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (over granule -surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; ➢ Polybrite 70QS (Quick -Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (over granule - surfaced APP or SBS only); ➢ Polybrite 90 High Slolids Silicone Roof Coating; ➢ Polybrite 95 Silicone Roof Coating. BUILDING PERMIT REQUIREMENTS: As required by the Building Offii ial or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the noted Q4 agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements QUALITY ASSURANCE ENTITY: I UL LLC—QUA9625; (314) 578-i406, k.chancellor@us.ul.com - THE 58-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - I i I I Exterior Research and Design, U.C. ' Evaluation Report P9290.02.08-R20 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-1122 Polyglass Modified Bitumen Roof Systems; (S70) 384-1230 Revision 20: 09/12/2017 Page 6 of 6 "TA'BLEIF- WOOD DECKS NEW CONSTRUCTION, t AbOPAP-0`06RRE'C`0VEA 7 A SA*((�Oitkw4kA 0QNDE"QQF�,C COVER fcALp kk� System Base Sheet --- Roof Cover (Note 25) MD Deck (Note 1) No. Type Fasten Attach Base Ply Cap (Psf) M' i�� A " "01 ­1� -"\E­"',Q A"Po""'IL4 5 ;15"a W E, 14 pt W i 4 4 -,, J"k""'v""�h � 7""i 44 A S A Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c. in two SBS-SA, APP-SA, SBS- W-136 inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows SBS-SA TA, APP-TA -52.5* W-137 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c. in two Polyflex SA Base APP-TA -S2.5* inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o:c. in 4-inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- _60.0* inch plywood (poly -film top) (2), equally spaced, staggered center rows TA, APP-TA -Min. 19/32-- Elastobase,.Elastobase-P_ _OMG-Flat-Bottom-Plates (square)-with.Roofgrip-#12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two Polyflex SA Base APP-TA I .0* inch plywood (poly -film top) (-2);-equally-spaced,-staggered center rows _ TABLE 6 Wcb4stk6cTib" 'k "6 Y", X, DECKS , 000, CONSTRUCTION TEAR� IFF '4 E YPk,�' E OF, VEW," % SYST W17 N�� ,N�Q�AT�D P System Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment,Base _Ply— � Ply Cap Ply No. ljogf I'M `SL>g"\ re v" w mr% Q A� narra a t� 1-5 S —S *AUW � T P.- W, -k W-141 Min. 15/32- (Optional) PG100 None Polyflex SA Base (Optional) APP-TA APP-TA -90.0 inch plywood W-142 Min. 15/32- PG100 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- -97.5 inch plywood TA, APP-TA TA, APP-TA Min. 15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA Plus, rolled into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 97.5 W-143 inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA - W-144 Min. 15/32- WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS- -105.0 inch plywood TA, APP-TA Min. 15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA -135.0 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional) APP-TA APP-TA 135.0 I inch plywood , place to create continuous bond. Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-1122 Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58