Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSaces Home ` Log In ;p 'Usec Regist[Etion Product Approval USER: Public User 'PrWurtAgoroyal tim a Pmduct ar FL APO cation'TYpe Code Version Application Status Comments Archiyed` Product; Manufacturer Address/Phone/Email Authorized Signature Technicai;Represepofive. Address/Phone/Email Quailty Assurance, Repeesentative Address/P. hone/Emiaii Category Subcategory Compliance;Method Florida Englneer or Architect Naine who, Evaluation Report .Florida License :Quality Assurance Entity, Quality Assurance.Contract.Ekoledtiori D Validated By Certificate rof; Independence SGANNEU Sj LueBY '011 t` I Submit SurchargQ ! Stats a Facts " ttaav Nc�� �avr Cap!+ Asi ra;agsrsks c��Ktncr rsa� :r U >:APPlkatlort Detail �C8C9 FL977Z=R11 Revision > Lke--r-(1ZP L 2017 ST. LUCIE COUNTY BUILDING DIVISION Approved REVI WED FOR COMPLIANC REVI�6E� dry, DATE PLANS AND PERMIT MUST BE _ PT ON JOB SITE OR NO INSPECTION(S) WILL BE MADE Owens CorAng One Owens,Cdfhl d Parkway Toledo; ON 43659 (740).404-7829 .greg,keeleroowenscorning.com ;Greg Keeler greg.keeler@owenseocning_.com' Roofing Underlayrnents Evaluation. Report from a. Florida Registered Architect or a, Licensed Florida Professional Engineer �w EvalUation,Report- Hardcopy Received the, Zachary Rr Priest THESE PLANS AND ALL PROPOSED WORK PE 741zi ARE SUBJECT TO ANY CORRECTIONS UL LLC, REQUIRED BY FIELD INSPECTORS THAT 12/31/2920 MAY BE NECESSARY IN ORDER TO Locke!Bowden COMPLY WITH ALL APPLICABLE CODES. ki, Validation checkllstr=:Hardcopy Received FL9777 •R11 COI OCR14002 8a 2017 FBC Evaluation 'Reoort weatherlo" k Non-HVHZ:odf. Refe.reneed'Standard.and Year (of Standald) ASTM:D 1970 ASTM D 226 ASTA' G i55 TAS 103 UL 1897 Equ valence orkoduct Standards Certified By. Year 2015 2009 2005 1995 2011 CONCEFJ.ED FAa^ T ENERS OR ATTACHMENTS ARE THE RESPONSIBILITYCIFTIE CONTRACTOR OR RECORD Sections from'the Code FILE COPY Product Approval Method Date Submitted Date Validated Date Penning FBC Approval - Date Approved Summary of Products Method 1, Option D 10/11/2Q17 1D/7:1/2.017 10/1.7/201.7 12/12/2017' ,FL # Model, Number or Name Description 9777. L Weatherlock G I Weatherproofing Underlayment Limits of Use In Instructions Approved for in HVHZ: No Approved for use outside HVHZ: Yes .Impact Resistant: N/A Design Pressure: N/A Other::See, evaluation report.for limits of use. FL9777 1111 II OCR14002 8a 2017 FBC Evaluation Report Weaffierlock Non-HVHZ,r)df Verified By: Zachary R., Priest 7,4021. Created by Independent Third Party' Yes Evaluation Reports FL9777 R11 AE OCR1anm.aa 2017 FBC Evaluation Reps I WeatherlockNon-HVHZ. odf. Created by Independent Third Party: Yes. 9777.2 Weatherlock. G (High fear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved foHV r use in.HZ: No. FL9777 Rif II OCR1400 8a 0, 7 FOC Evaluation' ReportApproved for outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other:. See evaluation reportfor limits of use. Weatherlock Non-HVHZ-odf Verified By: ZacharyR. Priest, PE-74021 Created by Independent Third Party: Yes Evaluation Reports. FL9777 1111 AE QCR14002 8a 2017 FB val'uation Report '1Aleatherlock Non-HVHZ.pdf Created byTndependentThird Party: Yes 9777.3 Weatherlock.MAT I Waterproofing Underlay ment Limits of Use Installation Instructions Approved for use lit HVHZ: Yes .171_9777 Rif II 0CR1400 8b 0 7 FBC Evaluation Report Approved, for use outside,NVH2: No Weatherlock HVHZ.pdf Impact Resistant: N/A Design Pressure: N/A. Other: See evaluation report for limits of use, Verified By:: Zachary R. Priest-74021, Created by Independent Third Party: Yes Evaluation Reports FL9777 R11` AE OCRI4002 8b 701-7 Far Evaluation Repo] Weatheriock HVHZ.pdf Created:by Independent Third Parry: Yes 9777.4 Weatherlock MAT Waterproofing Underiayment Limits of Use I Installation Instructions. Approved for use in HVHZ: No' Approved for use outside'HVHZ:;Yes FL9777 R11 II OCR1400 '_Ra �Of7 FBC Evaluation Rennrt Weatherlock Non-HVHZ:pdf Impact Resistant: N/A I Design' Pressure: N%A Other:. See evaluation report for limits of use. Verified By: Zachary R. Priest 74021 Created by Independent' Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Repo Weatherlock`Non-HVHZ. odf Created by Independent Third Party: Yes '9,777 5 Weatherlock Metal Weatherproofing,Underlayment Limits of Use Installation Instructions Approved for use In HVHZ: No .Approved for use outside HVHZ: Yes F 777-Ri II O R- ' ' 8a 017 FB valua ion Report W ath rlo k'Non-HVH ,odf Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes rlivahiatI66 Reports FL9777 1111 AE OCR14002 8a 2Q17 FBC Evaluation Report Weatherlock .Non-HVHZ: pdf - Created. by Independent Third. Party: Yes 9777.6 WeatherLockMetal Weatherproofing Underlaymerit Limits of'Use. Installation In Approved for use In HVHZ: Yes Approved,for.use.outside HVHZ: No FL9777 R11 'II OCR14002 8b 2017 FB valuation Report Weatherlo& HVHZ.Ddf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by,IndependentThird Party -'Yes •Other: See evaluation report for limits of use. Evaluation Reports 9777.7' WeatherLdck Spedalty Tile & Metal limits of Use Approved for use in HVHZ: No. Approved for use outside HVHZ Yes impact Resistant:.N/A Design Pressure: +0/w142.5 -Other: See:evaluation report for limits of use. 1i Created. by Independent Third Party: Yes Weatherproofing Uriderlayment. Installation Instructions FL9777 Rii II OCR14002 8a 2017 FBC Evaluation Renort 'Weatherlock Non-HVHZ.odf Verified By: Zachary. R. Priest 74021 Created•by Independent Third Party: Yes Evaluation Reports F0777' R11 AE 0014002. 8a 2017 MC Evaluation Reoort ;Weatherlock Non-HVHZ.odf' Created by, independent Third Party: Yes sack Naxt Contact. Us ::.2601 BiairStone Rodd Ulahassee FL 32394 Phone: 85.0-487-1824 The'State of Florida Is an.AA/EED employer. Copyright 2007-201 § State of Florida, ::'Privacy -Statement ;: Accessiblilty Statement.f c Refund Statement Under Florida law; emall addresses arie public records. If you ldo.not wantyour e-mail address released In response to a,pubiIt-records request, do not electronic mail this entity. Instead, contact the:ofBce.by phone or bytraditlonal mall. If you. -have any questions, please contact 850.487i139S. *Pursuant to Section 455:275(1),.Floiida Statutes, effective t)diobei 1, 2012, Ilcenseeslicensed under Chapter 455, F.S. must provide the Department wit4.an email address If they have one. The.emalis provided may be used for official communlcagon' with the licensee., However emall,addresses are public record. If you do not•wish to supply a personal address, please provide the Department with an email:ad-dress which.can'be made avaliable to the public To determine if you area licensee under Chapter 455, F.S.,• I please dick ham. Product Approval Accepts: i M®REE i CREEK'i TECHNICAL SERVICES; LLC EVALUATION REPORT' Manufacturer. Manufacturing Location: Quality Assurance: SCOPE OWENSCORNING 1,Qwens Coming R Toledo, OH:43657 (800) 438-7465 Brentwood, NH Houston, TX UL LLC(QUA9625) Certificate of Authorization No., 29824 17520 Edinburgh. Drive Tampa, FL 33647 (813)480.3421 FLORIDA BUILDING,CODE, e AND ASPHALT LLC Issued October If,. 2Q17 Category; Roofing Subcategory,: Undedayments Code Sections: 1604.3.1, 1507.1.1 Properties: Physical properties REFERENCES - Enti Report No. Standard Year ,PRI Construction Materials Technologies (TST5878) NEt-039-02-01 ASTM' 1976 20.15 PRI Construction -Materials' Technologies (TST5878) NEI=042-02=01.REV2, ASTM'D 1970 2015. PRI Construction;Metiadals Technologies (TST5878) NEI=045-02-01 'TAS 103 1995 PRi Constriction Materials Technologies (TST5878) NEI-045-02-01 ASTW;G:155 2005a PRI Construction Materials Technologies (TST5878) NEI-053-02-01 TAS 103 1905 PRI Construction. Materials Technologies (fST5878) NEl-053-62-01 ASTM'G 155 2005a PRI Construction Materials Technologle R 9 (TST5878) EI-093-02-02 ASTM D-1970 2015 PRI Construction Maferials.Technol Technologies (TST5878) OCF-213-02=01 ASTM D 1623 2009 PRI Construction. Materials Technologies (TST5878) OCF-237-02=01 UL 1897' 2012 PRI Construction•Materials Technologies (TST5878) QCF-252-02=01 ASTM D d798. ,2.00:1 PRI Construction Materials.Technologies (TST5878) OCF-252-02-01 ASTM D 1970 2016 PRI Construction.Materiais;Tech'nologies (TST5878) 6CF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) 6CF=2Z2 W;-01 TAS 103 1995. PRi Construction,Materials Technologies (TST5878) 'OGF-296;-02.02 ICGES AC 188'' '2012 ICC=ESAC48 2b12 PRI Construction Materials Technologies (TST5878) 0CF=297=02-01.1 ASTM D 1970 12015 PRi Construction Materials Technologies (TST5878) OCF-318-02 01 ASTM D 1970 2015, PRI Construction Materials Technologies (TST5878) OCF-320-02-0.1 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-320-02-01. ASTM GABS 2005a PRI Construction Materials Technologies (TST5878)' OGF-321-02.01 ASTM D 1623 2009 PRI Construction Materials Technologies. (TST5878). OCF-322-02-01 UL -1897 2012: PRI Construction Materials Technologies (TST5878) 0CF-355-02-0f UL 1897 2012 'Detennined to be 'equivalent to ASTM D 226-09, Type I and II 1 This evaluation report is provided for State of Florida product;approvai under Rule 6,.1G20-3. The manufacturer'shalf notify CREEK Technical SerVices, LLC of any product changes,or quality assurance changes throughoutthe-duration,for which -this report is valid. This evaluation .report doesnot express nor iinpiy, warranty; installation, recommended use, or other product attributes thatwe not specifically addressed herein. i CREEK .iG"� .," OWENS CORNING ROOFING AND ASPHALT LLC 1 � ley E 'WeatherLock® Self -Sealing Ice & Water Barriers TECHNICAL SERVICES, LL;C PRODUCT DESCRIPTION.AND'LIMITS OF USE Weathert-ock® G (Brentwood; .NH) WeatherLock® Mat (Brentwood, NH or Houston, 7X) WeatherL' ocke Metal (Brentwood, NH) WeatherLock® Specialty Tile & Metal (Brertwood, W. or' Houston, 7X) WeatherLockO G is an ASTM D 1970 self-adhesive underlayment. constructed from SBS modified .asphalt, •a 'fiberglass mat, reinforcement and surfaced with granules. The product is supplied in 2L%. rolls with nominal -dimensions of 3-ft x66.7-ft. WeatherLock® G is mechanically attachE maximum 30. days, WeatherLock® Mat is, ,SBSmodified; asphalt .sg. rolls with nominal d of'3-ftx 66.7-ft. WeatherLockO- Mat is mechanically, attached maximum.30 days. WeatherLock@), Metal SBS' modified asphal product is supplied in I to, be 'used as prescribed 'in FBC Section 1507.1.1' for coverings. Exposure on the roof`deck shall be limited to a ASTM. D 1970 self-adhesive .underlayment constructed from. a fiberglass,mat reinforcement.. The product. is supplied in I- nsions of 3-ft X-33.3-ft and 2 sq. rolls, With nominal dimensions itted ta,be used: as prescribed in FBC Section 1507..1.1 for coverings. Exposure on the, roof deck shall be iirriited to a' ASTM D 1.970 self-adhesive underlayment constructed' from a� fiberglass mat reinforcement and plastic: film surface. The I., rolls with nominal dimensions of 3-ft x 66:7-ft WeatherLock Metal is permitted to.be used as prescribed in FBC:Section 1507.1.1 for mechanically attached roof coverings; Exposure. on the:roof, deck shall be limited to a rhaximum,'90 days. i WeatherLockO.Specialty Tie & Metal is an ASTM D 1970 self-adhesive underlayment constructed from SBS mIodified asphalt and surfaced with a non -woven polyester fabric. The product is supplied in 2.14 sq. tolls with nominal dimensions of 3-ft•x 71:3-ft. WeatherLock® Specialty, Tile & Metal. is permitted to be used as prescribed in FBC. Section: 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay or concrete tiie ,roofing using either IC.P Adhesives Polyset AH-160 (ICP .Adhesives and Sealants,IInc.) or TILE BONDTAd Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof 'deck shall be limited to a. maximum 90 days. The maximum roof slope. shall: be 612 when used with clay or concrete tile installations without battens. Tile shall be .stored: on battens for, ,roof slopes: greater than 6:12. Tiles !shall,not be stacked greater 10 tiles per stack.. WeatherLock@':G (High WeatherLock -G (High Tear) is a.seWadhered', undedayment used as an alternative to Tear) ASTM D 226,. Type 1 or Type. 11 roofing; felt. and ASTM' D 197Q self -adhering polymer (Houston; TX) modified bitumen underlayment. The .underlayment is composed of SBS modified asphalt with a fiberglass mat iniemal, reinforcement and is surfaced with granules.. The, product is supplied with a nominal thickness: of 50 mils in 1.95-sq roils with. nominal dimensions of 3-4:x 654t. WeatherLock®' G (High -Tear) is permitted to be used as prescribed in FBC Section 15071-1 for mechanically attached roof coverings, Exposure on. the roof deck ;shall be, _ limited to a maximum 30 days. i This evaluation report"is provided for State of Florida product approval under:Rule 61;G20-3,, The manufacturer shall notify CREEK Technical SeNices,.LLC of any product changes or quality assurance changes throughout the,duration for'which this, report is valid. This evaluation: report does not express nor imply warranty, in4allation, recommended use, or other product attributes that are not specifically addressed herein. CREEK. TECHNICAL$ERviCEs, LLC . PRODUCT APPLICATION OWENS CORNING ROOFINGAND ASPHALT LLC WeatherLockO Self-Sealing.lce & Water Barriers Min. Roof Slope:. 2:12 in accordance with the FBC Application: All anderlayments shal/b. Installed in accordance with the-FBC. .Deck' substrates shall be II ,clean; .dry, ,and free from any irregularities and debris. All fasteners in. the deck sha/lobe checked for protrusion and corrected prior -to underiaymerif application. Prior to beginning instaliation, the underiayment shall be unrolled and allowed to relax for a,minAu* m of 3=5 minutes. The underlayment shall be installed with the release backer removed'and pressed firmly into Place to ensure complete, contact with the,deck,'The undedayment shall be installed. with the roll length parallel to the eave, starting. at the. eaves, and with minimum 3" side, laps and minimum 6° end laps staggered, min. 6-ft.from preceding course: Additionally, if applying WeatherLock® Specialty Tile &, Metal, end laps shall be primed with ASTM D 41 primer or sealed with aspjtalt roof cement a minimum of 3-4 inches across the width .of the lap. I It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with ther nail heads flush to the, top- surface of the: underlayment)..Additionally, WeatherLockO Specialty Tile &Metal Shall, be back nailed when installed on roof -slopes greater than 3:12. Min.. Application 40°F; Contact the manufacturer" when installing at temperatures below the minimum, Temperature: application temperature. i WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2`:1 margin of -safety per FBC Section 1.50.4.9. Undedayment. System No.1 WeatherLock Specialty Tile & Me" tal Only Roof Deck:. Min. 15/32-inch CDX plywood attached to wood supports spaced a; maximum 24" o.c. Underlayment: WeatherLock® Specialty, Tile I& Metal shall be, applied, in accordance with manufacturer's installation instructions to the fastened;'deck and backnalled along the selvage with, minimum 12ga.,, 1-1/4-inch galvanized ring shank roofing nails through optionally primed;. 32ga, x 1-5/8=jnch 0 tin caps spaced 12 o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design ,142.E psf Pressure: 3 of.4 This evaluation report is provided for State, -of Florida product approval under Rule'61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product,changes or quality assurance changes throughout the duration for which this report is valid.. This evaluation report does not express nor imply, warranty,,installation, recommended use, or other product attributes that -are not specifically addressed hereln.. OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLock® Self -Sealing Ice & Water Barriers TECHNICAL SERVICES,,'LLC GENERAL LIMITATIONS. 1) This evaluation report is not use in the HVHZ.: 2) Fire Classification is not within the scope of this evaluation.. 3) Installation of the evaluated product shall comply with'this report, the FBC, and •the manufacturer's published application instructions. Where discrepancies exist between these sources, the: more restrictive and FB'C' compliant installation detailshall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deckarea shall be properly ventilated. in accordance with the FBC requirements. 6) All side lap seams shall be.instailed to she uiater from the deck. 7) The underlayment may be used as: described in. other current FBC.product approval documents. 8) Design wind load pressures -shall be determined for components and cladding in accordance with FBC. 1609. 9) The roof deck shall be designed, by others, in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) ,Maximum Design Pressures for a .given .underlayment shall meet or exceed ;the design wind loads determined for the roof assembly. 11) All products listed in this reportshall be, manufactured under a quality:assurance program in compliance with Rule 61 G20=3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, .P.E. have demonstrated compliance with the. Florida, Building Code 6' Edition (2(117) as evidenced' in the referenced documents submitted by the named manufacturer.. ,``����>Y r tr"i���, No. .74021 STATE OF 0 ki �ss ONA`�\,� III l/lI[;1llititL��� , CERTIFICATION OF INDEPENDENCE. 201 T10. A 09:Ob 29 —04t0V Zachary R. Priest, P.E. Florida Registration No.74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have; nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated;, or controlled iby anycompany manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire,, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will. acquire, a financial interest In any other entity involved in the approval process of the product END OF REPORT OCR14002.8a= of 4' I his evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of anyproduct:changes or quality assurance changes throughout the duration for which this: report is valid. This evaluation report does:not express nor imply warranty, installation,, recommended use,. or other product' attributes that are not specifically addressed herein. I