HomeMy WebLinkAboutREVISION 5-21-18Y OFFICE USE ONLY: C
DATE FILED: st Lu� ��lI'm� PERMIT # .? �- C L 4}REVISION FEE: RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DMSION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652 ,CO n T - CTO R COPY
(772) 462.1553 I V R/"'i
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS: _
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
To ...�v�DI C1 � a � . I I Tv yh N 51 5'irk ►� f� 0���4& cs u s n -Nv rt �y= -� i7 �%
CONTRACTOR-1 NFORMATION:
STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #:
BUSINESS NAME: N C '
QUALIFIERS NAME:- �jtl W N f=• - y 12 Vi A fA
ADDRESS: J?3 Q ' 1 T I�F C $ � T ke If taw A !9
CITY: STATE: ZIP:*_ �•i 1
PHONE (DAYTIME): I -11 FAX: fo l_,) jr q q
OWNERBUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE:
PHONE (DAYTIME:
ARCMTECT/ENGINEER INFORMATION:
FAX:
ZIP:
CONCEALED FASTENERS OR ATi ACHMENTS
ARE THE RESPONSIBILI T Y OF THE
MIA+Jwtl,CONTRACTOR OR RECORD
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
Polyglass USA, Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442 _ _•„ ... _. CONTRACTOR COPY
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Modified Bitumen Roof System Over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#15-0928.05 and consists of pages 1 through 63. THESE PLANS AND ALL PROPOSED WORK
The submitted documentation was reviewed by Alex Tigera. ARE SUBJECT FI ANY CORRECTIONS
REQUIRED BY FELD INSPECTORS THAT
L
I MAY BE NECESSARY IN ORDER TO
'(Z- ® COMPLY WITH ALL APPLICABLE CODES.
ST. LUCIE COUNTY BUILDING D VISION NOA No.: 17-0824.09
REVIEWED FOR COMPLIANC Expiration Date: 09/13/22
REVIEWED B Approval Date: 09/14/17
DATE Page 1 of 63
PLANS AND PERMIT MUST BE KEIPT ON JOB
SITE OR NO INSPECTIONS) WILL BE MADE
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Modified Bitumen
Materials SBS/APP
Deck Tyne: Wood
Maximum Design Pressure -120 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Polyglass G2 Base 108' x 36" ASTM D 4601 Asphalt -coated fiberglass reinforced base sheet
Type H
Polyflex SA Base 66' 8" x 3' 3-3/8"
ASTM D 4601 Self -adhered, fiberglass reinforced, APP modified
Type If bitumen base sheet.
Elastobase 65' 8" x 3' 3-3/8"
ASTM D 6163 SBS modified asphalt coated fiberglass reinforced base
sheet.
Elastoflex SA V 66' 8" x 3' 3 18"
ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified
Type I bitumen membrane with a self -adhering back face and
a smooth top surface.
Elastoflex SA V FR 66' 8" x 3' 33/8"
ASTM D 6163 Self -adhered, fire -rated, fiberglass reinforced, SBS
modified bitumen membrane with a self -adhering back.
face and a smooth top surface.
Elastoflex SA V 66' 8" x 3' 3 3/8"
ASTM D 6163 Self -adhered, fiberglass reinforced, SBS modified
PLUS
bitumen membrane with a self -adhering back face and
a smooth top surface.
Elastoflex SA V 66' 8" x 3' 3 3/8"
ASTM D 6163 Self -adhered, fiberglass reinforced, SBS modified
PLUS FR
bitumen membrane with a a fire retardant additive,
self -adhering back face and a smooth top surface.
Elastoflex V 32' 10" x 3' 3-3/8"
ASTM D 6163 Torch, hot asphalt or cold adhesive applied, fiberglass
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a sanded
top surface. Also available in a thicker version listed as
Elastoflex V 2.5.
Elastoflex VG 32' 10" x 3' 3-3/8"
ASTM D 6163 Torch, hot asphalt or cold adhesive applied, fiberglass
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
granule top surface.
Elastoflex VG FR 32' 10" x 3' 3-3/8"
ASTM D 6163 Torch, hot asphalt or cold adhesive applied, fire -rated,
fiberglass reinforced, SBS modified bitumen
membrane with a burn off polyethylene or sanded back
face and a granule top surface and fire retardant
chemistry.
Polyglass HT Base 65' 8" x 3' 3-3/8"
ASTM D 6163 SBS modified asphalt coated fiberglass reinforced base
650
sheet.
NOA No.: 17-0824.09
MIAMI-DAD' COUNTY
Expiration Date: 09/13/22
Approval Date: 09/14/17
Page 2 of 63
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product
Dimensions Specification Description
XtraFlex SBS Base
66' 8" x 3' 3 3/8" ASTM D 6163 Self -adhered, fiberglass reinforced, SBS modified
SA
bitumen membrane with a self -adhering back face and
a smooth top surface.
XtraFlex SBS Glass
65' 8" x 3' 3-3/8" ASTM D 6163 SBS modified asphalt coated fiberglass reinforced base
Base
sheet.
XtraFlex SBS Glass
32' 10" x 3' 3-3/8" ASTM D 6163 Torch, hot asphalt or cold adhesive applied, fiberglass
Interply
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a sanded
top surface.
XtraFlex SBS HT
65' 8" x 3' 3-3/8" ASTM D 6163 SBS modified asphalt coated fiberglass reinforced base
Base 650
sheet.
Elastobase P
65' 8" x 3' 3-3/8" ASTM D 6164 SBS modified asphalt coated polyester reinforced base
sheet.
Elastoflex S6
32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
polyethylene or sanded top surface.
Elastoflex S6 G
32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
granule top surface.
Elastoflex S6 G FR
32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, fire -rated,
polyester reinforced, SBS modified bitumen membrane
with a burn off polyethylene or sanded back face and a
granule top surface and fire retardant chemistry.
Elastoshield TSG
32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
granule top surface.
Elastoshield TSG FR 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, fire -rated,
polyester reinforced, SBS modified bitumen membrane
with a burn off polyethylene or sanded back face and a
granule top surface and fire retardant chemistry.
Polyfresko G SBS 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
granule top surface.
Polyfresko G SBS FR 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, fire -rated,
polyester reinforced, SBS modified bitumen membrane
with a burn off polyethylene or sanded back face and a
granule top surface and fire retardant chemistry.
NOA No.: 17-0824.09
MIAMI DADE COUNTY Expiration Date: 09/13/22
Approval Date: 09/14/17
Page 3 of 63
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
XtraFlex SBS Poly 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester
Base reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
polyethylene or sanded top surface.
XtraFlex SBS Poly G 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, fire -rated,
polyester reinforced, SBS modified bitumen membrane
with a burn off polyethylene or sanded back face and a
granule top surface and fire retardant chemistry.
Polybond 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
Polybond G 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a granule top surface.
Polyflex 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
Polyflex G 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a granule top surface.
Polyflex G FR 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, fire -rated, polyester reinforced, APP
modified bitumen membrane with a burn off
polyethylene back face and a granule top surface and
fire retardant chemistry.
Polyfresko G 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a granule top surface.
Polyfresko G FR 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, fire -.rated, polyester reinforced, APP
modified bitumen membrane with a burn off
polyethylene back face and a granule top surface and
fire retardant chemistry.
XtraFlex APP G 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, fire -rated, polyester reinforced, APP
modified bitumen membrane with a burn off
polyethylene back face and a granule top surface and
fire retardant chemistry.
XtraFlex APP S 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
XtraFlex Kool APP G 32' 10" x 3' 3-3/8"
ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a granule top surface.
NOA No.: 17-0824.09
Expiration Date: 09/13/22
Approval Date: 09/14/17
Page 4 of 63
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Polyglass APP Base 65' 8" x 3' 3 3/s" ASTM D 6509 APP modified asphalt coated fiberglass reinforced base
Type I sheet.
PG 100 Asphalt 1, 3, 5, 50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of
Primer tube or 17 oz. spray selected asphalts used to promote adhesion.
can
XtraFlex 10 Asphalt
Primer
PG 325 Cold Process
Adhesive
PG 350 Mod Bit
Adhesive
Polyplus 35 Premium
Mod Bit Adhesive
PG 450 Flashing
Cement
PG 500 MB Flashing
Cement
Polyplus 45 Premium
Flashing Cement
Polyplus 50 Premium
MB Flashing Cement
Polyplus 55 Premium
Modified Flashing
Cement
XtraFlex 50 Premium
Modified Wet/Dry
Cement
PG 400 Plastic Roof
Cement
PG 425 Wet/Dry
Plastic Roof Cement
1, 3, 5, 50, 55 gal,
ASTM D41
A penetrating solution of solvent and a blend of
tube or 17 oz. spray
selected asphalts used to promote adhesion.
can
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered cold process adhesive for use with roll or
tube
Type III
BUR roofing.
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered rubberized adhesive designed for use with
tube
Type III
modified bitumen membranes.
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered rubberized adhesive designed for use with
tube
Type III
modified bitumen membranes.
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement.
tube
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use
tube
with modified bitumen membranes.
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement.
tube
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use
tube
with modified bitumen membranes.
1, 3, 5, 50, 55 gal. or ASTM D4586 A mastic compound for use as a roof flashing adhesive.
tube
1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use
tube with modified bitumen membranes.
1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use in
tube ASTM D3409 dry or damp conditions.
1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use in
tube ASTM D3409 dry or damp conditions.
NOA No.: 17-0824.09
Expiration Date: 09/13/22
Approval Date: 09/14/17
Page 5 of 63
EVIDENCE SUBMITTED:
Test Agency
Factory Mutual Research
Corporation
Underwriters Laboratory
Trinity I ERD
PRI Asphalt Technologies
Test Name/Report
4470
4470
4470
4470
4470
4470
TAS 114
UL 790
TAS 114
TAS 114
TAS 114
TAS 117(B)-ASTM D6862
ASTM D 6164 / D 6222
TAS 114
ASTM D6163 / ASTM D 4601
FM 4470 & TAS 114
TAS 117 (B) & TAS 114
ASTM D6164
TAS 114
TAS 114
ASTM D6509
ASTM D6222
ASTM D6222
ASTM D6163
ASTM D6164
TAS 114 & FM 4474
ASTM D4601 / TAS 117
ASTM D4601
ASTM D6162
ASTM D6162
ASTM D6163
ASTM D6163
TAS 114 & FM 4474
TAS 114 & FM 4474
TAS 114
ASTM D6222
ASTM D6163
ASTM D6694
ASTM D6694
Report No.
2W7A7.AM
3000857
3004091
3001334
3031350
RR202591
OONK20869
R14571
11751.05.03
11758.08.03
P1738.02.07
C8500SC.11.07
P10490.10.08-R1
P13760.09.09
P33960.03.11
P33970.03.11
P39680.03.13
P37590.03.13-3A
11757.12.00-1-R1
11757.04.01-1-R1
P37590.03.13-1-R1
P37590.07.13-2
P37590.03.13-5-R1
P37590.03.13-2-R1
P37590.07.13-1
P41630.08.13
P45940.09.13
P44370.10.13
SC5170.05.15
SC5170.12.15-1
PLYG-P45440SC.03.15-2-R1
PLYG-P45440SC.03.15-1-R1
PLYG-SC8905.05.16-1
PLYG-SC8905.05.16-2
P 1734.07.06-R2
PUSA-062-02-01
PUSA-064-02-02
PUSA-134-02-01
PUSA-135-02-01
Date
08.04.94
01.12.00
01.12.00
02.15.00
09.27.07
10.22.15
06.08.00
06.30.15
05.30.03
08.11.03
02.05.07
11.30.07
10.03.08
09.10.09
03.15.11
03.15.11
03.04.13
03.06.13
04.29.13
04.30.13
06.26.13
07.01.13
07.01.13
07.01.13
07.02.13
08.06.13
09.04.13
10/04/13
05.08.15
12/29/15
12.29.15
02.19.16
05.17.16
05.17.16
08.24.16
12.04.07
02.27.08
05.16.14
05.16.14
NOA No.: 17-0824.09
Expiration Date: 09/13/22
Approval Date: 09/14/17
Page 11 of 63
Membrane Type: SBS
Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank attached to structural supports at a maximum of 24" o.c.
with #8 wood screws at 6" o.c.
System Type E(14): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply o ���b lastobase P, Polyglass HT Base 650, XtraFlex SBS Glass Base or
XtraFlex SB - ase 650 fastened to the deck as described below:
Fastening:
11 ga. Annular ring shanked nails and 1-5/8" tin -caps 6" o.c. in 4" lap and 6" o.c. in four
equally spaced staggered rows. Tin -caps are primed with PG 100 Asphalt primer or XtraFlex
10 Asphalt Primer.
Pl beet:
One or more plies of Elastobase, Elastobase P, Elastoflex S6, Elastoflex V, Elastoflex V 2.5,
( p 'oval)
Polyglass HT Base 650, XtraFlex SBS Glass Base, XtraFlex SBS Glass Interply, XtraFlex
SBS HT Base 650, XtraFlex SBS Poly Base, one or more plies of Type IV or VI ply sheet
adhered in full mopping of approved asphalt applied within the EVT range and at a rate of
20-40 lbs./sq.
Or
One ply of Elastoflex SA V*, Elastoflex SA V FR*, Elastoflex SA V PLUS*, Elastoflex SA
V PLUS FR* or XtraFlex SBS Base SA* self -adhered.
*Requires torch -applied ply or cap sheet.
Membrane:
One of Polybond, Polybond G, Eoly""flex olyflex G, Polyflex G FR, Polyfresko G,
ply
Polyfresko G FR, XtraFlex APP G, XlraFl"el APP S, XtraFlex Kool APP G torch applied.
Or
One ply of Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TSG, Elastoshield TSG FR,
Polyfresko G SBS, Polyfresko G SBS FR or XtraFlex SBS Poly G torch or hot asphalt
applied.
Surfacing:
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional)
required fire classification.
Maximum Design
Pressure:
-112.5 psf; (See General Limitation #7)
NOA No.: 17-0824.09
r IAMI•oAD COUNTY Expiration Date: 09/13/22
Approval Date: 09/14/17
Page 60 of 63
WOOD DECK SYSTEM LIMITATIONS:
A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LumaTATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-401bs./sq. or mechanically attached using the fastening pattern of the top layer.
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each
side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is
not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application
of either system shall be at a minimum rate of 121bs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lb£ insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect or Registered Roof
Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from
Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS
117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect or Registered Roof Consultant (When this limitation is specifically referred within this
NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 17-0824.09
MIAMI•DADE COUNTY Expiration Date: 09/13/22
Approval Date: 09/14/17