HomeMy WebLinkAboutEVALUATION REPORT0
QOTRINITY
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
0Y I EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
ERD ILrU lYU1 as 353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203)262-9245
Evaluation Report 01506.01.08-1122
FL10124-R20
Date of Issuance: 01/03/2008
Revision 22: 09/20/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for. compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it inter
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or contro
3. Robert Nieminen, P.E. does not have nor will
which the evaluation reports are being issued
4. Robert Nieminen, P.E. does not have, nor will
product. 1
5. This is a building code evaluation. Neither
project on which this Evaluation Report, or p
specifically for that purpose.
I
I
i
i
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/20/2017. This does not serve as an electronically signed
document.
f to acquire or will it acquire, a financial interest in any company manufacturing or
A by any company manufacturing or distributing products it evaluates.
Icquire, a financial interest in any company manufacturing or distributing products for
acquire, a financial interest in any other entity involved in the approval process of the
inityI ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
wious versions thereof, is/was used for permitting or design guidance unless retained
OTPJNITYIERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Aspihalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the 61h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
I
2. STANDARDS:
Section
1507.2.4 / 1507.1.1,
13905.2:3 / R905.1.1
'1507.2.5, R905.2.4
1507.2.7.1, R905.2.6.1
1507.2.7.1, R905.2.6.1
1507.2.7.1, R905.2.6.1
3. REFERENCES:
Entity
GAF (PDM 1915)
PRI(TST 5878)
PRI(TST 5878)
PRI (TST 5878)
PRI(TST 5878)
PRI(TST 5878)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL(TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL(TST 1740)
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Proaerty
Standard
Physical Properties
I
ASTM D1970
Physical Properties
'ASTM'D3462
Wind Resistance
ASTM D3161
Wind Resistance
ASTM D7158
Wind Resistance
I
,I
TAS 107
Examination Reference
Letter ofjEquivalency Seal -A -Ridge Impact Resistant IR
Physical Properties GAF-025-02-01
ASTM D31462 GAF-059-02-01
ASTM
D31462
GAF-080-02-01
Physical Properties
GAF-324-02-01
Wind
Driven Rain
GAF-407-02-01
ASTM
D3462
93NK6295
ASTM
D3462
99NK43835
TAS 107 I
94NK9632
ASTM
D3462
011\11(06632
ASTM
D3161,TAS 107
OINK9226
ASTM
D3161
01NK37122
ASTM
1)3462
OINK37122
ASTM
D3161,TAS 107
02NK12980
ASTM
D31611, TAS 107
02NK30871
ASTM
D3161
03CA5367
ASTM
D3462
03NK26444
ASTM
D3462
04NK13850
ASTM
D3161
04NK13850
ASTM
1)3161�
04NK30546
ASTM
D34621
04NK22009
ASTM
1)3161�,
04NK22009
ASTM
D3462';
05NK27924
ASTM
D3161,
05NK27924
ASTM
D3161JD3462
06CA18077
ASTM
D3161, D3462
06CA18074
ASTM
D3161,D3462
06CA35251
ASTM
D3462 I
06CA31603
ASTM
D3161,D3462
06CA41095
ASTM
D3161
07NK05228
ASTM
i
D3161 i
06CA31611
ASTM
D3161
06CA61148
ASTM
D3161, 6;3462
07CA31742
ASTM
D3161, D7158, D3462
08CA06100
1
6T" EDITION (2017) FBC NON-HVHZ EVALUATION
GAF Asphalt Roof Shingles
Year
2015
2010
2016
2011
1995
Date
01/13/2012
03/27/2002
09/02/2004
05/25/2005
12/01/2011
01/21/2013
11/29/1993
01/12/2000
03/29/2000
02/02/2001
05/21/2001
12/18/2001
12/19/2001
04/10/2002
09/09/2002
03/11/2003
10/17/2003
06/07/2004
06/23/2004
03/10/2005
05/06/2005
05/09/2005
02/10/2006
02/11/2006
06/05/2006
06/16/2006
10/18/2006
12/01/2006
12/27/2006
03/13/2007
04/04/2007
04/09/2007
11/O8/2007
03/13/2008
Evaluation Report 01506.01.08-1122
F1.10124-1120
Revision 22: 09/20/2017
Page 2 of 6
Entity
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL, LLC..(TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
UL, LLC. (QUA 9625)
Examination
ASTM D3161, D3462
ASTM D3161, D3462
ASTM D3161, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, 1)715I , D3462
ASTM D3462
ASTM D3462 {
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, 1)71;58, D3462
ASTM D3161, D7 I58, D3462
ASTM D3462
ASTM D3161, D7158, D3462
ASTM D3161 i
ASTM D3161
ASTM D3161
ASTM D3161, D7258, D3462
ASTM D3161, D7158, D3462
Quality Control I
Quality Control
Quality Control
Quality Control
Quality Control I
Quality Control
Quality Control
Quality Control
Quality Control)
Quality Control)
Quality Control
Quality Control,
Quality Control
��TRINITYJERD
Reference
07CA55908
09CA10592
09CA06856
09NK06647
09CA27281
10CA35554
10CA13686
10CA07264
10CA11953
10NK11951
1ONK12070
08CA06100
10CA53934
11CA48924
11CA47919
11CA48408
11CA48725.'
12CA34891
12CA58151,
12CA38083
13CA32332
13CA37934
4786875675
4787434542
Inspection Report, R21, Mobile, AL
Inspection Report, R21, Myerstown, PA
Inspection Report, R21, Tuscaloosa, AL
Inspection Report, R21, Michigan Cty, IN
Inspection Report, R21, Shafter, CA
Inspection Report, R21, Savannah, GA
Inspection Report, R21, Minneapolis, MN
Inspection Report, R21, Mt. Vernon, IN
Inspection Report, R21, Baltimore, MD
Inspection Report, R21, Tampa, FL
Inspection Report, R21, Dallas, TX
Inspection Report, R21, Ennis, TX
Inspection Report, R21, Fontana, CA
Date
04/01/2008
03/26/2009
05/15/2009
08/01/2009
08/27/2009
03/05/2010
05/15/2010
05/27/2010
10/29/2010
10/30/2010
11/04/2010
01/30/2010
03/31/2011
10/22/2011
12/03/2011
12/08/2011
12/09/2011
10/12/2012
02/15/2013
02/26/2013
06/18/2013
08/02/2013
07/17/2015
05/17/2016
10/25/2016
10/20/2016
11/11/2016
11/01/2016
11/17/2016
11/11/2016
10/25/2016
10/25/2016
10/21/2016
11/17/2016
11/04/2016
11/03/2016
11/01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal iSovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® II, Fortitude'"', Glenwood'"", Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShield,f Monaco®, Sienna°, Timberline® American Harvest®, Timberline®
ArmorShieldT" II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra
HD® and Woodland° are fiberglass reinforced, laminated asphalt roof shingles.
4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip & Ridge Shingles:
4.2.1 Seal -A -Ridge° Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge®
ArmorShieldT" Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip
and ridge asphalt roof shingles)
i
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1122
Certificate of Authorization #9503 6T" ED�TION (2017) FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 3 of 6
I
i
��TRINITYJERD
4.3 Accessory Starter Strips:
I.
4.3.1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlocker'" Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS
modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-
inch or less.
I
4.3.3 StarterMatch'"" Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series !asphalt shingles. StarterMatch'"° are installed as the second starter for Grand
Canyon® and Grand Sequoia® series installations. '
S. LIMITATIONS:
5.1
5.2
5.3
5_4
5.4.1
5.4.2
5.4.3
5.5
This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for aIny project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
i
This Evaluation Report is 'I of for use in FBC HVHZ jurisdictions.
Fire Classification is notl part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this' product.
Wind Classification:
The GAF asphalt shinglesi noted in'Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasd = 150 mph (V„It = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
The GAF hip & ridge shine
and R905.2.6.1 to ASTM I
to Vasd = 150 mph (V„it = V
Classification 'by ASTM D7
mean roof height of 60
conditions outside these li
All products in the roof as:
6. INSTALLATION:
6.1
6.1.1
6.2
6.2.1
6.3
Underlayment:
as noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
161, Class F, indicating the shingles are acceptable for use in all wind zones up
mph). Refer to Section 6 for installation requirements to meet this wind rating.
i8 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
!et or less. Calculations by a qualified design professional are required for
itations. Contact the shingle manufacturer for data specific to each shingle.
rbly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3.
Installation of Pro -Start Eave%Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peell& Stick Starter Roll shall comply with the GAF current published instructions.
Asphalt Shingles:
6.3.1 Installation of asphalt shingle's shall comply with the GAF current published instructions, using minimum four
(4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield,
and Woodland require minimum five (5) nails per shingle.
➢ Slateline requires minimum six (6) nails per shingle.
6.3.2 Fasteners shall be in accordanlce with manufacturer's published requirements, but not less than FBC 1507.2.6
or R905.2.5. Staples are not p'I rmitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for (details.
Exterior Research and Design, I.I.C. I Evaluation Report 01506.01.08-R22
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 4 of 6
6.4 Hip & Ridge Shingles:
6.4.1 Installation of Seal -A -Ridge Ridge Q
Seal -A -Ridge ArmorShield Ridge Cap
a minimum two (2) nails, minimum
beads of Henkel "Loctite PL S30 Roof
,11.5'
;1 (292 mmy
Nail
Clavo
6.5/8".- 7'5I8° Cfoiie[
(168 -194 mm)
12'
(805 mm)
6.4.2 Installation of Timbertex Premium Ri
with a minimum two (2) nails, minim
Gun Grade Polyurethane Sealant or F
U-5'
1 (292 mm)
ii7
Molt
Moi
V I RINITY I ERD
Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and
singles shall comply with the GAF current published instructions with
8-inch head diameter, per shingle and nominal 0.25-inch diameter
Flashing Sealant".
6 Sellante,
i mm} Enduft d'etanch6it6
Cap Shingles shall comply with GAF current published instructions
3/8-inch head diameter, per shingle and beads of.Sonneborn NP1
el PL Roofing and Flashing Sealant.
1` 6ollnnl�
1ntn� Endliit rl'dfartcts�:`Esi
f
W
(305 W'rn)
12•
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
i
6T" EDITION (2017) FBC NON-HVHZ EVALUATION
GAF Asphalt Roof Shingles
Evaluation Report 01506.01.08-1122
FL10124-R20
Revision 22: 09/20/2017
Page 5 of 6
VT--R1NrryjERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the ,required classifications detailed in FBC
Table 2507.2.7.1 / R9 5.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
i
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
�I
UL LLC—QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.01.08-1122
6' EDITION (2017) FBC NON-HVHZ EVALUATION F1.10124-1120
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 6 of 6