Loading...
HomeMy WebLinkAboutEVALUATION REPORT0 QOTRINITY EVALUATION REPORT GAF 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 0Y I EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 ERD ILrU lYU1 as 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203)262-9245 Evaluation Report 01506.01.08-1122 FL10124-R20 Date of Issuance: 01/03/2008 Revision 22: 09/20/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for. compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it inter distributing products it evaluates. 2. Trinity I ERD is not owned, operated or contro 3. Robert Nieminen, P.E. does not have nor will which the evaluation reports are being issued 4. Robert Nieminen, P.E. does not have, nor will product. 1 5. This is a building code evaluation. Neither project on which this Evaluation Report, or p specifically for that purpose. I I i i The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/20/2017. This does not serve as an electronically signed document. f to acquire or will it acquire, a financial interest in any company manufacturing or A by any company manufacturing or distributing products it evaluates. Icquire, a financial interest in any company manufacturing or distributing products for acquire, a financial interest in any other entity involved in the approval process of the inityI ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any wious versions thereof, is/was used for permitting or design guidance unless retained OTPJNITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Aspihalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. I 2. STANDARDS: Section 1507.2.4 / 1507.1.1, 13905.2:3 / R905.1.1 '1507.2.5, R905.2.4 1507.2.7.1, R905.2.6.1 1507.2.7.1, R905.2.6.1 1507.2.7.1, R905.2.6.1 3. REFERENCES: Entity GAF (PDM 1915) PRI(TST 5878) PRI(TST 5878) PRI (TST 5878) PRI(TST 5878) PRI(TST 5878) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL(TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL(TST 1740) Exterior Research and Design, LLC. Certificate of Authorization #9503 Proaerty Standard Physical Properties I ASTM D1970 Physical Properties 'ASTM'D3462 Wind Resistance ASTM D3161 Wind Resistance ASTM D7158 Wind Resistance I ,I TAS 107 Examination Reference Letter ofjEquivalency Seal -A -Ridge Impact Resistant IR Physical Properties GAF-025-02-01 ASTM D31462 GAF-059-02-01 ASTM D31462 GAF-080-02-01 Physical Properties GAF-324-02-01 Wind Driven Rain GAF-407-02-01 ASTM D3462 93NK6295 ASTM D3462 99NK43835 TAS 107 I 94NK9632 ASTM D3462 011\11(06632 ASTM D3161,TAS 107 OINK9226 ASTM D3161 01NK37122 ASTM 1)3462 OINK37122 ASTM D3161,TAS 107 02NK12980 ASTM D31611, TAS 107 02NK30871 ASTM D3161 03CA5367 ASTM D3462 03NK26444 ASTM D3462 04NK13850 ASTM D3161 04NK13850 ASTM 1)3161� 04NK30546 ASTM D34621 04NK22009 ASTM 1)3161�, 04NK22009 ASTM D3462'; 05NK27924 ASTM D3161, 05NK27924 ASTM D3161JD3462 06CA18077 ASTM D3161, D3462 06CA18074 ASTM D3161,D3462 06CA35251 ASTM D3462 I 06CA31603 ASTM D3161,D3462 06CA41095 ASTM D3161 07NK05228 ASTM i D3161 i 06CA31611 ASTM D3161 06CA61148 ASTM D3161, 6;3462 07CA31742 ASTM D3161, D7158, D3462 08CA06100 1 6T" EDITION (2017) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Year 2015 2010 2016 2011 1995 Date 01/13/2012 03/27/2002 09/02/2004 05/25/2005 12/01/2011 01/21/2013 11/29/1993 01/12/2000 03/29/2000 02/02/2001 05/21/2001 12/18/2001 12/19/2001 04/10/2002 09/09/2002 03/11/2003 10/17/2003 06/07/2004 06/23/2004 03/10/2005 05/06/2005 05/09/2005 02/10/2006 02/11/2006 06/05/2006 06/16/2006 10/18/2006 12/01/2006 12/27/2006 03/13/2007 04/04/2007 04/09/2007 11/O8/2007 03/13/2008 Evaluation Report 01506.01.08-1122 F1.10124-1120 Revision 22: 09/20/2017 Page 2 of 6 Entity UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL (TST 1740) UL, LLC..(TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (TST 9628) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) UL, LLC. (QUA 9625) Examination ASTM D3161, D3462 ASTM D3161, D3462 ASTM D3161, D3462 ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, 1)715I , D3462 ASTM D3462 ASTM D3462 { ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, D7158, D3462 ASTM D3161, 1)71;58, D3462 ASTM D3161, D7 I58, D3462 ASTM D3462 ASTM D3161, D7158, D3462 ASTM D3161 i ASTM D3161 ASTM D3161 ASTM D3161, D7258, D3462 ASTM D3161, D7158, D3462 Quality Control I Quality Control Quality Control Quality Control Quality Control I Quality Control Quality Control Quality Control Quality Control) Quality Control) Quality Control Quality Control, Quality Control ��TRINITYJERD Reference 07CA55908 09CA10592 09CA06856 09NK06647 09CA27281 10CA35554 10CA13686 10CA07264 10CA11953 10NK11951 1ONK12070 08CA06100 10CA53934 11CA48924 11CA47919 11CA48408 11CA48725.' 12CA34891 12CA58151, 12CA38083 13CA32332 13CA37934 4786875675 4787434542 Inspection Report, R21, Mobile, AL Inspection Report, R21, Myerstown, PA Inspection Report, R21, Tuscaloosa, AL Inspection Report, R21, Michigan Cty, IN Inspection Report, R21, Shafter, CA Inspection Report, R21, Savannah, GA Inspection Report, R21, Minneapolis, MN Inspection Report, R21, Mt. Vernon, IN Inspection Report, R21, Baltimore, MD Inspection Report, R21, Tampa, FL Inspection Report, R21, Dallas, TX Inspection Report, R21, Ennis, TX Inspection Report, R21, Fontana, CA Date 04/01/2008 03/26/2009 05/15/2009 08/01/2009 08/27/2009 03/05/2010 05/15/2010 05/27/2010 10/29/2010 10/30/2010 11/04/2010 01/30/2010 03/31/2011 10/22/2011 12/03/2011 12/08/2011 12/09/2011 10/12/2012 02/15/2013 02/26/2013 06/18/2013 08/02/2013 07/17/2015 05/17/2016 10/25/2016 10/20/2016 11/11/2016 11/01/2016 11/17/2016 11/11/2016 10/25/2016 10/25/2016 10/21/2016 11/17/2016 11/04/2016 11/03/2016 11/01/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal iSovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, Fortitude'"', Glenwood'"", Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield,f Monaco®, Sienna°, Timberline® American Harvest®, Timberline® ArmorShieldT" II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra HD® and Woodland° are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge Shingles: 4.2.1 Seal -A -Ridge° Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShieldT" Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles) i Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1122 Certificate of Authorization #9503 6T" ED�TION (2017) FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 3 of 6 I i ��TRINITYJERD 4.3 Accessory Starter Strips: I. 4.3.1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlocker'" Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- inch or less. I 4.3.3 StarterMatch'"" Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series !asphalt shingles. StarterMatch'"° are installed as the second starter for Grand Canyon® and Grand Sequoia® series installations. ' S. LIMITATIONS: 5.1 5.2 5.3 5_4 5.4.1 5.4.2 5.4.3 5.5 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for aIny project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. i This Evaluation Report is 'I of for use in FBC HVHZ jurisdictions. Fire Classification is notl part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this' product. Wind Classification: The GAF asphalt shinglesi noted in'Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V„It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. The GAF hip & ridge shine and R905.2.6.1 to ASTM I to Vasd = 150 mph (V„it = V Classification 'by ASTM D7 mean roof height of 60 conditions outside these li All products in the roof as: 6. INSTALLATION: 6.1 6.1.1 6.2 6.2.1 6.3 Underlayment: as noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 161, Class F, indicating the shingles are acceptable for use in all wind zones up mph). Refer to Section 6 for installation requirements to meet this wind rating. i8 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a !et or less. Calculations by a qualified design professional are required for itations. Contact the shingle manufacturer for data specific to each shingle. rbly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. Installation of Pro -Start Eave%Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peell& Stick Starter Roll shall comply with the GAF current published instructions. Asphalt Shingles: 6.3.1 Installation of asphalt shingle's shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordanlce with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not p'I rmitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for (details. Exterior Research and Design, I.I.C. I Evaluation Report 01506.01.08-R22 Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 4 of 6 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge Ridge Q Seal -A -Ridge ArmorShield Ridge Cap a minimum two (2) nails, minimum beads of Henkel "Loctite PL S30 Roof ,11.5' ;1 (292 mmy Nail Clavo 6.5/8".- 7'5I8° Cfoiie[ (168 -194 mm) 12' (805 mm) 6.4.2 Installation of Timbertex Premium Ri with a minimum two (2) nails, minim Gun Grade Polyurethane Sealant or F U-5' 1 (292 mm) ii7 Molt Moi V I RINITY I ERD Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and singles shall comply with the GAF current published instructions with 8-inch head diameter, per shingle and nominal 0.25-inch diameter Flashing Sealant". 6 Sellante, i mm} Enduft d'etanch6it6 Cap Shingles shall comply with GAF current published instructions 3/8-inch head diameter, per shingle and beads of.Sonneborn NP1 el PL Roofing and Flashing Sealant. 1` 6ollnnl� 1ntn� Endliit rl'dfartcts�:`Esi f W (305 W'rn) 12• 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, I.I.C. Certificate of Authorization #9503 i 6T" EDITION (2017) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Evaluation Report 01506.01.08-1122 FL10124-R20 Revision 22: 09/20/2017 Page 5 of 6 VT--R1NrryjERD 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the ,required classifications detailed in FBC Table 2507.2.7.1 / R9 5.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: i As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: �I UL LLC—QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.01.08-1122 6' EDITION (2017) FBC NON-HVHZ EVALUATION F1.10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 6 of 6