Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONIJI G SC(r�NNUJJ TAMKO BUILDING PRODCUTS, INC. �� TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO@ TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non - perforated orgai is felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below.. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to' underlayment application. The roof deck shall be constructed of closer fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have, no more than 1/8" gap at abutting joints. The minimum application temperature shall a) The minimum application tem Underlayment shall be 40°F. b) The minimum application tem The minimum roof slope shall be in accordE a) The minimum slope of TAMK Underlayments shall be exposed in accoi exposure exceed 30 days. Exception: TAMKOO TW Metal al Self -adhering underlayments may be ad All roof coverings shall be mechanically Allowable Roof Coverings. 50°F except as follows: 3ture of TAMKOO TW Metal and Tile Underlayment and TAMKOO TW of TAMKO@ Moisture Guard@ shall be 35'F. with FBC requirements except as follows: ASTM Slate Surfaced Roll Roofing shall be 2:12. with the manufacturer's recommendations, but in no case shall Tile Underlayment may be exposed for a maximum 90 days. to primed or unprimed plywood substrates in the non-HVHZ. through the underlayment to the roof deck. Metal Roof Mineral Asphalt Panels and Surfaced Rol_I` Shlrigles and ' State Clay and Underayment, ; Shin les, §hm les` Roofin _J'.'Sfiakes• : ` Shingles . :Concrete 'Tile TAMKOO ASTM Slate. Y1 N N N N Y Surfaced Roll Roofing TAM KOOASTM Tile N N N N N Y Underlayment TAMKOO Master Smooth Y1 N N N N N TAMKOO Moisture Guard@ Y N N N N N TAMKO@ No.15 ASTM Asphalt Saturated Organic Y Y Y YZ N N Felt TAMKOO No.15 UL Asphalt Y Y Y YZ Y N Saturated Organic Felt TAMKO@ No. 30 ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKO@ No. 30 UL Asphalt Y Y Y N Y N Saturated Organic Felt TAMKOO TW Metal and Tile Y Y N N N Y Underlayment TAMKOO TW Underlayment Y Y N N N N TAMKOO TAM -FELT Y N N N N N _ Notes: 1) Open valley applications per 1507.2.9.2 2} Wo-o-a shingles only I TBP14001.4 FL12328-R8 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK, TCHNICAL SERVICi EES, LLC EVALUATION REPORT Manufacturer: TAMKO BUILE P.O. Box 1404 Joplin, MO 64E (417) 624-664, Quality Assurance: UL LLC SCOPE Category: Roofing Subcategory: U nderlayments Code Sections: 1507.1.1 Properties: Physical propel PRODUCT DESCRIPTION PRODUCTS, INC. Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, 61H EDITION (2017) Issued October 19, 2017 TAMKO® ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO® ASTM Tile ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO® Master Smooth TAMKO® Moisture Guard® TAMKOB No. 15 ASTM Asphalt Saturated Organic Felt TAMKO@) No. 15 UL Asphalt Saturated Organic Felt TAMKO® No. 30 ASTM Asphalt Saturated Organic Felt TAMKO® No. 30 UL Asphalt Saturated Organic Felt ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated with.asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ASTM D 226, Type II underayment constructed from a non -perforated organic felt that is saturated with asphalt. TAMKO® TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO® TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. TBP14001.4 This evaluation report is provided for State of Technical Services, LLC of any product chant This evaluation report does not express nor ii specifically addressed herein. FL12328-R8 Page 1 of 4 rida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK or quality assurance changes throughout the duration for which this report is valid. 1 warranty, installation, recommended use, or other product attributes that are not CREEK TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the s 2) Wind uplift resistance in not within s 3) Installation of the evaluated product application instructions. Where dis compliant installation detail shall pre 4) Contact the manufacturer when insti 5) Unless otherwise stated, the minims 6) All underlayments shall be installed in successive courses installed up laps shall be staggered between cot 7) The underlayment may be used as ( 8) The underiayment shall not be instal 9) Contact the manufacturer regarding 10) All products listed in this report shall Rule 61G20-3. REFERENCES Enti PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies UL LLC (TST9628) TBP14001.4 TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments of this evaluation. of this evaluation. comply with this report, the FBC, and the manufacturer's published incies exist between these sources, the more restrictive and FBC ig attemperatures below the minimum application temperature. roof slope shall be in accordance with FBC requirements. th the roll length parallel to the eave, starting at the eave, and lapped deck in a manner that effectively sheds water from the deck. End as in accordance with the manufacturer's application instructions. scribed in other current FBC product approval documents. I over existing roof coverings. ecific exposure limits for each underiayment. i manufactured under a quality assurance program in compliance with Report No. TAP-192-02-01 TAP-193-02-01 TAP-214-02-01 TAP-215-02-01 TAP-216-02-03 TAP-217-02-01 REV TAP-218-02-01 TAP-219-02-01 TAP-220-02-01 TAP-222-02-01 TAP-245-02-01 TAP-311-02-01 TAP-319-02-01.1 TAP-387-02-01 TAP-388-02-01 13CA12269 FL12328-R8 Standard ASTM D 1970 ASTM D 1970 ASTM D 4869 ASTM D 226 ASTM D 6380 ASTM D 6380 ASTM D 226 ASTM D 226 ASTM D 6380 ASTM D 4869 TAS 103 ASTM D 4798 ASTM D 1970 ACC 188 ASTM D 1970 ASTM D 1970 ASTM D 226 Year 2015a 2015a 2016 2009 2003(2013) 2003(2013) 2009 2009 2003(2013) 2016 1995 2011 2015a 2012 2015a 2015a 2009 3of4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREAK TAMKO BUILDING PRODCUTS, INC. TAMKO Underlaymen%- ' TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary) R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. I ,,ttj1111111811�' ,•°�'P�G E N S R'Fs'% 2017.10.19 No 74021 c : ..12:15:58 -� --04'00' :13 STATE OF : W ���T'• ;A,� P: N���� Zachary R. Priest, P.E. Florid/Q N A1- E�� % Organization ation No. Registration No. 021 A E9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing,or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001.4 I FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes) or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I