Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE9CANNFL 'FORM R405-201.7 S FLORIDA ENER f',MWNCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON Street: /� \ Q D"e, City, State, Zip: FT. PIERCE, FL, Owner: WYNNE BUILDING CROP Design Location: FL, Fort Pierce 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows(141.3 sqft.) Description a. U-Factor: Sgl, U=0.54 SHGC: SHGC=0.25 �.'!J-Factor: Sgl, U=0.55 SHGC: SHGC=0.25 c' U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types (1445.5 sqft.) a. Slab -On -Grade Edge Insulation b. N/A c. N/A Glass/Floor Area: 0.098 Builder Name: WYNNE BUILDING COPR. Permit Office: ST. LUCIE COUNTY Permit Number: Jurisdiction: ST. LUCIE COUNTY County:: St. Lucie (Florida Climate Zone 2 ) New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types (1446.0 sqft.) Insulation Area Yes a. Under Attic (Vented) R=30.0 1446.00 ftZ 1446 b. N/A R= ft2 c. N/A R= ft2 0 11. Ducts R ft2 Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 101.25 2 40.00 W 12. Cooling systems kBtu/hr Efficiency a. Central Unit 34.8 SEER:15.00 ft2 13. Heating systems kBtu/hr Efficiency ft2 a. Electric Heat Pump 34.8 HSPF:8.50 3.8182 ft. 0.250 14. Hot water systems a. Electric Cap: 40 gallons Insulation Area EF:0.970 R=0.0 1445.50 ft2 b. Conservation features R= 1 ft2 None R= f( ft2 15. Credits Pstat Total Proposed Modified Loads: 48.03 PASS I Total Baseline Loads: 48.08 I hereby certify that -the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. (� n� ... 9 .o I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNE DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 114E so a COD wv, - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory► -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Elie, 01 4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 • I r 1 I FORM R405-2017 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: I 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House an: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp 7/ Design'Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort'Pierce FL_VERO_BEACH_MUNI I 39 90 70 75 299 62 Low I BLOCKS Number Name Area Volume 1 Entire House 1446 I 11568 I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 301 2408 I No 0 1 1 Yes Yes Yes 2 WIC 63 504 I No 0 1 No Yes Yes 3 M:BATH 56 448 No 0 1 Yes Yes Yes i 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes # Floor Type Space I Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On=Grade Edge Insulatio I BEDROOM 52 ft 0 301 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio I M. BATH1 8 ft 0 56 ft2 ---_ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHE � 1 ft 0 192 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATHi 5 ft 0 45 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio I ENTRY 7 ft 0 55 ft2 ____ 0 1 0 I 4/4/2018 12:13 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORAA R4n5-9nl7 FL100 RS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft I 0 488 ft2 ---- 0 1 0 (ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area I Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 I I 240 ft2 Light 0.6 No 0.9 No 0 18.4 ' I ATTIC { V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented I 150 1446 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM i 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC I 30 Blown 63 ft2 0.1 Wood 3 Urider Attic (Vented) M. BATH i 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH j 30 Blown 45 ft2 0.1 Wood 6 -Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRYI 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DI i ING 30 Blown 488 ft2 0.1 Wood I WALLS Adjacent Spa ce Cavity Width Height Sheathing Framing Solar Belo w i _ 1 NE=>SW Exterior Concrete Block - Ext Insd3EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 1 2 SW=>NE Exterior Concrete Block - Ext InsdBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 1 3 NW=>SE Exterior Concrete Block - Ext Insd9EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BA I I H 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 6 NE=>SW Exterior. Concrete Block - Ext InEEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 _ 7 SE=>NW Exterior Concrete Block - Ext In9EDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 i _ 8 S=>N Exterior Concrete Block - Ext InfiED i OOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InREDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 I 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsLRAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 I 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN i 11 24 8 192.0 ft2 0.23 0.6 0 4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS IV # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the enteredl orientation => changed to Worst Case. / Wall V I Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 SW=>NE 4 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 SE=>NW 7 Metal Low-E Single Yes 0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in None None 4 NE=>SW1.3 Metal Low-E Single Yes 04 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>SE14 Metal Low-E Single Yes 0�55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 i 24ft 8ft 11 IIYI IL 1 FXr%I SWIM # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM # System Type Subtype I Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split i HSPF:8.5 34.8 kBtu/hr 1 sys#1 (COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split i SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM I System Type SubType Location EF Cap Use SetPnt Conservation I ` 1 Electric None Garage I 0.97 40 gal 60.9 gal 120 deg None i SOLAR HOT WATER SYSTEM i FSEC Cert # Company Name I Collector System Model # Collector Model # Area Storage Volume FEF None None i ft2 i I I I 4/4/2018 12:13 PM . EnergyGaugew USA - FlaRes2017 Section R405.4.1 Compliant Software i Page 4 of 5 FORM R405-2017- DUCTS ---- Supply --- --- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area i Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ftZ Attic 85 ftz ; Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES rogramable Thermostat: Y r.cpe� Ceiling Fanolin [[ Jan Feb Mar [ j A r Ma Jun [X] Jul Au Se [ ]Oct [ Nov Dec ating [X� Jan f X Feb �X� Mar [ ]Apr I May Jun [ ]Jul rj Au�Xj rj SeP [ ]Oct [X� Nov Dec Ventin [[ Jan [ Feb XMar [X] A r May Jun [ ] Jul Aug Se [X] Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 7.8 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 168 68 68 68 68 68 68 66 66 i i 4/4/2018 12:13 PM EnergyGaug6® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 I - I 2017 - AIR BARRIER AND INSULATION INSPECT19IN COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: WYNNE THE GRAND CARLTON I Builder Name: WYNNE BUILDING COPR. Street: I Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRI�IERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall } } requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sellaled. not be used as a sealing material. I The air barrier in an dropped ceiling/soffit /soffit Shall be aligned with Ceiling/attic � y pp g i g the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. ! Cavities within corners and headers of frame walls Walls f The junction of the top plate and the top of exterior walls shall be i shall be insulated by completely filling the cavity with i sealed. I j a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. I minimum. • Exterior thermal envelope insulation for framed walls I I shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists - Rim joists shall include the air barrier. I Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of I Floor framing cavity insulation shall be installed to (including insulation. i maintain permanent contact with the underside of above -garage I subfloor decking, or floor framing cavity insulation ; and cantilevered shall be permitted to be in contact with the top side fioors) ; of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. ! Crawl space walls i Exposed earth in unvented crawl spaces shall be covered with I Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. I shall be permanently attached to the crawlspace walls. fI I Shafts, Duct shafts, utility penetrations, and flue shafts opening to penetrations F exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. I i Recessed lighting Recessed light fixtures installed in the building thermal envelope I Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring I Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on I installation readily conforms to available space shall extend Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box orb The air barrier shall be installled behind electrical or communication be installed. exterior walls 4 boxes or air -sealed boxes shall I HVAC register boots HVAC register boots that penetrate building thermal envelope shall Ibe sealed to the sub -floor oe drywall. Concealed i When required to be sealed, concealed fire sprinklers shall only be Esprinklers sealed in a manner that is recommended by the manufacturer. fill Caulking or other adhesive�sealants shall not be used to voids between fire sor er plates + a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/4/2018 12:13 P9 EnergyGaugew USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I 11 i I FORM R405-2017 I ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformarice Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1446 7. Windows- Description Area a. U-Factor: Sgl, U=0.54 101.25 ft2 SHGC: SHGC=0.25 b* U-Factor: Sgl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 c. U-Factor: N/A ft2 • SHGC: d. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. N/A R= ft2 c. N/A R= ft2 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 325 12. Cooling systems kBtu/hr Efficiency a. Central Unit 34.8 SEER:15.00 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 14. Hot water systems Cap: 40 gallons a. Electric EF: 0.97 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Ene igy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. I Builder Signature: Date: Address of New Holne:2'1�ZkR__City/FL Zip:. Q�CQ WE *Note: This is not a Building Energy Rating. If youlr Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida (Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florid I Building Code, Energy Conservation, if not DEFAULT. I i 414/2018 12:13 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1