HomeMy WebLinkAboutENERGY EFFICIENCY CODE9CANNFL
'FORM R405-201.7 S
FLORIDA ENER f',MWNCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CARLTON
Street: /� \ Q D"e,
City, State, Zip: FT. PIERCE, FL,
Owner: WYNNE BUILDING CROP
Design Location: FL, Fort Pierce
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
7. Windows(141.3 sqft.) Description
a. U-Factor: Sgl, U=0.54
SHGC: SHGC=0.25
�.'!J-Factor: Sgl, U=0.55
SHGC: SHGC=0.25
c' U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types (1445.5 sqft.)
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
Glass/Floor Area: 0.098
Builder Name: WYNNE BUILDING COPR.
Permit Office: ST. LUCIE COUNTY
Permit Number:
Jurisdiction: ST. LUCIE COUNTY
County:: St. Lucie (Florida Climate Zone 2 )
New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0
192.00 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types (1446.0 sqft.)
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ftZ
1446
b. N/A
R=
ft2
c. N/A
R=
ft2
0
11. Ducts
R ft2
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
101.25 2
40.00 W
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
34.8
SEER:15.00
ft2
13. Heating systems
kBtu/hr
Efficiency
ft2
a. Electric Heat Pump
34.8
HSPF:8.50
3.8182 ft.
0.250 14. Hot water systems
a. Electric Cap: 40 gallons
Insulation Area EF:0.970
R=0.0 1445.50 ft2 b. Conservation features
R= 1 ft2 None
R= f( ft2 15. Credits Pstat
Total Proposed Modified Loads: 48.03 PASS
I Total Baseline Loads: 48.08
I hereby certify that -the plans and specifications covered by
this calculation are in compliance with the Florida
Energy
Code.
(� n�
... 9 .o
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNE
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
114E so
a
COD wv,
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory► -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
Elie, 01
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
• I r
1
I
FORM R405-2017
PROJECT
Title:
WYNNE THE GRAND CARL
Bedrooms: I 2
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1446
Lot #
Owner Name:
WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: Yes
PlatBook:
Builder Name:
WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST. LUCIE COUNTY
Whole House an: No
City, State,
Zip:
FT. PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
7/ Design'Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL,
Fort'Pierce FL_VERO_BEACH_MUNI I 39
90
70
75
299
62
Low
I BLOCKS
Number
Name
Area
Volume
1
Entire House
1446
I
11568
I
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BEDROOM
301
2408 I No
0
1
1
Yes
Yes
Yes
2
WIC
63
504 I No
0
1
No
Yes
Yes
3
M:BATH
56
448 No
0
1
Yes
Yes
Yes
i
4
KITCHEN
192
1536 Yes
0
1
No
Yes
Yes
5
BATH
45
360 No
0
1
Yes
Yes
Yes
6
BEDROOM 2
204
1632 No
0
1
1
Yes
Yes
Yes
7
ENTRY
55
440 No
0
1
Yes
Yes
Yes
8
LAUNDRY
42
336 No
0
1
Yes
Yes
Yes
9
GREAT/DINING
488
3904 No
0
1
Yes
Yes
Yes
# Floor Type
Space I
Perimeter Perimeter R-Value
Area Joist R-Value
Tile
Wood
Carpet
1 Slab-On=Grade Edge Insulatio
I
BEDROOM
52 ft
0
301 ft2 ----
0
1
0
2 Slab -On -Grade Edge Insulatio
WIC
1 ft
0
63 ft2 ----
0
1
0
3 Slab -On -Grade Edge Insulatio
I
M. BATH1
8 ft
0
56 ft2 ---_
0
1
0
4 Slab -On -Grade Edge Insulatio
KITCHE �
1 ft
0
192 ft2 ----
0
1
0
5 Slab -On -Grade Edge Insulatio
BATHi
5 ft
0
45 ft2 ----
0
1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2
32.2 ft
0
203.5 ft2 ----
0
1
0
7 Slab -On -Grade Edge Insulatio
I
ENTRY
7 ft
0
55 ft2 ____
0
1
0
I
4/4/2018 12:13 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
FORAA R4n5-9nl7
FL100 RS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft I 0
488 ft2
----
0
1
0
(ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
I Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
I
I 240 ft2
Light
0.6
No
0.9
No
0
18.4
'
I ATTIC
{ V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
I 150
1446 ft2
N
N
I
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM i
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC I
30
Blown
63 ft2
0.1
Wood
3 Urider Attic (Vented) M. BATH i
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH j
30
Blown
45 ft2
0.1
Wood
6 -Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRYI
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DI i ING
30
Blown
488 ft2
0.1
Wood
I
WALLS
Adjacent Spa ce
Cavity Width
Height
Sheathing Framing
Solar
Belo
w
i
_ 1 NE=>SW Exterior Concrete Block - Ext Insd3EDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
1
2 SW=>NE Exterior Concrete Block - Ext InsdBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
1
3 NW=>SE Exterior Concrete Block - Ext Insd9EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BA I I H
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
_
6 NE=>SW Exterior. Concrete Block - Ext InEEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
_ 7 SE=>NW Exterior Concrete Block - Ext In9EDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
i
_ 8 S=>N Exterior Concrete Block - Ext InfiED i OOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InREDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
I
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsLRAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
I
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINT
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
i
11 24
8
192.0 ft2
0.23
0.6
0
4/4/2018 12:13 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
DOORS
IV # Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>NW
Insulated
ENTRY
None
.39 3
1
6 8
20.6 ft2
WINDOWS
Orientation shown is the enteredl orientation => changed to Worst Case.
/ Wall
V
I
Overhang
# Ornt ID Frame
Panes
NFRC
U-Factor SHGC
Imp
Area Depth
Separation
Int Shade
Screening
1 NW=>SE 3 Metal
Low-E Single
Yes
0.54 0.25
N
32.9 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 SW=>NE 4 Metal
Low-E Single
Yes
0.54 0.25
N
6.9 ft2 1 ft 0 in
1 ft 4 in
None
None
3 SE=>NW 7 Metal
Low-E Single
Yes
0.54 0.25
N
24.0 ft2 6 ft 0 in
1 ft 4 in
None
None
4 NE=>SW1.3 Metal
Low-E Single
Yes
04 0.25
N
37.5 ft2 1 ft 0 in
1 ft 4 in
None
None
5 NW=>SE14 Metal
Low-E Single
Yes
0�55 0.25
N
40.0 ft2 8 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
I GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 315ft2
315ft2
i 24ft
8ft
11
IIYI IL 1 FXr%I SWIM
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7
HEATING SYSTEM
# System Type
Subtype
I Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
i HSPF:8.5 34.8 kBtu/hr
1
sys#1
(COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
i SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
I
System Type SubType
Location
EF Cap Use SetPnt
Conservation
I `
1 Electric None
Garage
I 0.97 40 gal 60.9 gal 120 deg
None
i
SOLAR HOT WATER SYSTEM
i
FSEC
Cert # Company Name
I
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
i
ft2
i
I
I
I
4/4/2018 12:13 PM . EnergyGaugew USA - FlaRes2017 Section R405.4.1 Compliant Software
i
Page 4 of 5
FORM R405-2017-
DUCTS
---- Supply ---
--- Return ----
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area
i Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 325 ftZ
Attic
85 ftz
; Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
rogramable Thermostat: Y
r.cpe�
Ceiling Fanolin
[[ Jan
Feb
Mar
[
j A r
Ma
Jun [X] Jul
Au
Se
[ ]Oct
[ Nov
Dec
ating [X� Jan
f X Feb
�X� Mar
[
]Apr I
May
Jun [ ]Jul
rj
Au�Xj
rj
SeP
[ ]Oct
[X� Nov
Dec
Ventin [[ Jan
[ Feb
XMar
[X]
A r
May
Jun [ ] Jul
Aug
Se
[X]
Oct
[X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
7.8
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
168
68 68
68
68
68
68
66
66
i
i
4/4/2018 12:13 PM EnergyGaug6® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
I
- I
2017 - AIR BARRIER AND INSULATION INSPECT19IN COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I
Project Name: WYNNE THE GRAND CARLTON I Builder Name: WYNNE BUILDING COPR.
Street: I Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRI�IERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
}
} requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sellaled.
not be used as a sealing material.
I The air barrier in an dropped ceiling/soffit /soffit Shall be aligned with
Ceiling/attic � y pp g i g
the insulation and any gaps in the air barrier shall be sealed.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
! Cavities within corners and headers of frame walls
Walls
f The junction of the top plate and the top of exterior walls shall be
i shall be insulated by completely filling the cavity with
i sealed. I
j a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
I minimum.
•
Exterior thermal envelope insulation for framed walls
I
I shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights The space between window/door jambs and framing, and
and doors skylights and framing shall be sealed.
Rim joists - Rim joists shall include the air barrier. I Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of I Floor framing cavity insulation shall be installed to
(including insulation. i maintain permanent contact with the underside of
above -garage I subfloor decking, or floor framing cavity insulation
;
and cantilevered shall be permitted to be in contact with the top side
fioors) ; of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
! Crawl space walls i Exposed earth in unvented crawl spaces shall be covered with
I Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
I shall be permanently attached to the crawlspace walls.
fI
I Shafts, Duct shafts, utility penetrations, and flue shafts opening to
penetrations
F exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
I
i Recessed lighting
Recessed light fixtures installed in the building thermal envelope
I
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
I
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
I
installation readily conforms to available space shall
extend
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box orb The air barrier shall be installled behind electrical or communication
be installed.
exterior walls 4 boxes or air -sealed boxes shall
I
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
Ibe sealed to the sub -floor oe drywall.
Concealed i When required to be sealed, concealed fire sprinklers shall only be
Esprinklers sealed in a manner that is recommended by the manufacturer.
fill
Caulking or other adhesive�sealants shall not be used to voids
between fire sor er plates
+
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/4/2018 12:13 P9 EnergyGaugew USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I
11
i
I
FORM R405-2017 I
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformarice Index, the more efficient the home.
, FT. PIERCE, FL,
1. New construction or existing
New (From Plans)
2. Single family or multiple family
Single-family
3. Number of units, if multiple family
1
4. Number of Bedrooms
2
5. Is this a worst case?
Yes
6. Conditioned floor area (ft2)
1446
7. Windows- Description
Area
a. U-Factor: Sgl, U=0.54
101.25 ft2
SHGC: SHGC=0.25
b* U-Factor: Sgl, U=0.55
40.00 ft2
SHGC: SHGC=0.25
c. U-Factor: N/A
ft2
• SHGC:
d. U-Factor: N/A
ft2
SHGC:
Area Weighted Average Overhang Depth:
3.832 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types
Insulation
Area
a. Slab -On -Grade Edge Insulation
R=0.0
1445.50 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
9. Wall Types
Insulation
Area
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0
192.00 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1446.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
34.8
SEER:15.00
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
14. Hot water systems
Cap: 40 gallons
a. Electric
EF: 0.97
b. Conservation features
None
15. Credits Pstat
I certify that this home has complied with the Florida Ene igy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. I
Builder Signature: Date:
Address of New Holne:2'1�ZkR__City/FL Zip:. Q�CQ
WE
*Note: This is not a Building Energy Rating. If youlr Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida (Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florid I Building Code, Energy Conservation, if not DEFAULT.
I
i
414/2018 12:13 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1