HomeMy WebLinkAboutLETTER-ROOFING SPECIFICATIONArchitectonic InIc April 4; 2018 SCANNED Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce; FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at, 3466 Sunrise Blvd., Saint Lucie County; Florida Manufacturer: Extreme Metal Fabricators, LLC. Profiles: 26 Ga. 5iv Crimp FL. #17022.5 Code: FBC 201I ; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: Pitch: 30' Maximum 3/12 Minimum Required Design Pressure: Zone1: j38.2 Zone 2: -53.9 Zone3: -101.4 Maximum Uplift Pressure: -86 Fasteners: #10 x 1 pancake wood screw (or of sufficient length to meet 3/16" min. penetration through deck or 5/8" min. embedment into wood plank) Underl.ayment: Owen's Corning Weatherlock, FL# 9777.5 (self -adhering) Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. Of FAO tfully subrtiit ,• ��' p,ELkA( .� 1 5,6l 9gg9 K/ e-tonic-Inc. c�srEREo P�`G 806 Delaware Avenue Tel: 772 460 7751 www.architectoniciric.com