• FL # FL9777-R11
Application Type Revision
Code Version ' 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Represen
Address/Phone/Email
Category
Subcategory .
Compliance Method
Florida Engineer or Architect
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract
Validated By
in
Owens Coming
One Owens Coming Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg. Keeler@owenscorning.com
` !�
6 1�
tir
Roofing
Undcrlayments
Evaluation Reportfrom a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
who developed Zachary R. Priest
PE-74021 .
UL LLC
on Date 12/31/2020
Locke Bowden
I
0 . Validation Checklist - Hardcopy Received
Certificate of Independence I FL9777 R11 COI OCR14002 8a 201.7 FBC EvaluatiQn Report
Weatherlock Non-HVHZ.odf
4
Referenced Standard. and Year (of Standard) Standard Year
I
I
j
I
Equivalence of Product Standards
Certified By
I
Sections from the Code
I
I ,
' I
i
I
I
j
ASTM D 1970
2015
ASTM D 226
2009
ASTM G 155
2005
TAS 103
1995 .
UL 1897
2012
i
i
�I
j
Product Approval Method
Method 1 Option D
.Date Submitted I
10/11/2017
Date Validated
10/11/2017
Date Pending.FBC Approval I
10/17/2017
Date Approved
12/12/2017
I
Summary of Products
FL #
Model,l Number or Name
Description
9777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use I
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL9777 RII II OCRI4002 8, 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odf
Verified By: Zachary,R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 1131 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Nan-HVHZ.pdP
Created by Independent Third Party: Yes
9777.2
Weath!erLock G (High Tear)
Weatherproofing Underlayment
Limits of Use I
Approved for use In HVHZ: No
Installation Instructions
Fl 9777 R11 II 0CR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
EL9777 R11 AE OCR140028a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes
Impact Resistant: N/A I
Design Pressure: N/A
Other: See evaluation report for limits of use.
Weatherlock Non-HVHZ.odf
I
Created by Independent Third Party: Yes
9777.3 Weatiterlock MAT Waterproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZJYes FL9777 1111 II OCR14002.81J 2017 FBC Evaluation Report
Approved for use outside HVHZ: No Weatherlock HVHZ.pdf
Impact Resistant N/A I Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third,Party: Yes
Others See evaluation reportfor limits of use. Evaluation Reports
I FL9777 R11 AE OCR14002.8b 7017 FBC Evaluation Report
Weatherlock HVHZ,Ddf
Created by Independent Third Party: Yes
9777.4.
Weatherlock MAT,
Waterproofing Underlayment
Limits of Use I
Approved for use in HVHZ No
Approved for use outside lHVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation repoi for limits of use.
Installation Instructions
Fl 9777 R11 II OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Nan-HVHZ pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third. Party: Yes
Evaluation Reports
FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
-eatherlork Non-HVHZ.pdf
Created by. Independent Third Party: Yes
9777.5 WeatherLock Metal
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
i
9777.6 WeatherLock Metal
i
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: See'evaluation report for limits of use.
Weatherproofing Underlayment
Installation Instructions
FL9777 R11 II O R14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odf '
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation. Reports
FL9777 R11 AE OCRI4002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
Weatherproofing Underlayment
Installation Instructions
Fl 9777 Rll II OCR14002 8b 2017 FBC Evaluation Report
Weatherlock HVHZ.odf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 '1111 AE OCR14002 8b 20 7 FBC Evaluation Report
r
Weatherlock HVHZ.IL
Created by Independent Third'Party: Yes
9777.7 WeatherLock SpecialtyTile & Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9777 R11 II OCR14002.8a 2017 FBC Evaluation Report
Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ,pddf
Impact Resistant; N/A Verified By: Zachary R. Priest 74021
Design Pressure: +0/-142.5 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
I FL9777 1111 AE CCR14002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us ;; 2601 Blair Stone Road, Tallahassee FL 3239R Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida, :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall, If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 112012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one.. The
emalls provided may be used for ofnclal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
® a
Credit Card
Safe
i
r
�I
.G-REEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6m EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Coming Parkway
Toledo, OM 43657
(800) 438-7465 .
www.owenscoming.com
i
Manufacturing Location: Brentwood, NH
Houston, iTX
Quality Assurance:. UL LLC (gUA9625)
SCOPE
Category:
Subcategory:
Code Sections:
Properties:
REFERENCES
Roofing
1504.3.1, T507.1.1
Physical properties
Issued October 11, 2017
Ent& I
Report No.
Standard
Year
PRI Construction Materials Technologies (11ST5878)
NEI-039-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01 REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 165
2005a
PRI. Construction Materials Technologies.(TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093-02-02
ASTM D 1970
.2015
PRI Construction Materials Technologies (TST5878)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
.
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001,
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-272-02-01
TAS 103
1965
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
ICC-ES AC 188'
2012
ICC-ES AC 48
2012
PRI Construction Materials Technologies (TST5878) ,
0CF-297-02-01.1
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF�18-02-01
ASTM D 1910
2015
PRI Construction Materials Technologies (TST5878).
OCF-326-0241
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
ASTM-D 1623 -
2009
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OGF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226-09, Type I
and 11
This evaluation report is provided for
Technical Services, LLC of any prodr
This evaluation report does not expr
specifically addressed herein.
ate of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
changes or quality assurance changes throughout the duration for which this report is valid.
nor imply warranty, installation, recommended use, or other product attributes that are not
I
CREEK
TECHNICAL SERviCEB, LLC
I
i
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING -ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
WeatherLock® G
WeatherLock® G is an ASTM D 1970 self-adhesive underayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.74
I
Weatherl_ock® G is permitted to be used as prescribed in FBC Section 1607.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 36 days.
WeatherLock® Mat
Weatheri_ock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, T)Q
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof. coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof. coverings. Exposure on the roof deck shall be limited to a
maxiniuml90 days.
WeatherLock®
WeatherLock® Specialty Tile &. Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, M
WeatherLockO Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered iclay or concrete the roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BONEP Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete file installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 files per stack.
WeatherLockO G (High
Weathel Lock® G (High Tear) is a self -adhered, underlayment used as an alternative to
Tear)
ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
(Houston, 7)Q
modified bitumen underlayment_ The underlayment is composed of SBS modified
asphalt! with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
Weathl rLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
I
I
OCR14002.8a FL9777-1111 1 Page 2 of 4
This evaluation report Is provided for�State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
I
i
I
CREEK
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self-Sealingice & Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All.undedayments shall be installed in accordance with the FBC.
j
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in tihe deck shall be checked for protrusion and corrected prior to underlayment
application. I Prior to beginning installation, the undedayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
i
The underla�ment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3° side
.laps and minimum 6° end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap. I
It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, Weatherl-ock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: applicatlon temperature.
I ,
WIND RESISTANCE II
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per.FBC Section 1504.9.
Roof Deck:
Underlayment:
Maximum Design
Pressure:
OCR14002.8a
This evaluation report is provid(
Technical Services, LLC of any
This evaluation report does not
specifically addressed herein.
YY{idllltll L.Ulll� a7UOl.lO1Ly , IIG (11VIG101 v,lly_
Min. 1 32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
WeatherLock® Specialty Tile. & Metal shall be applied in accordance with
manufacturer's installation instructions -to the. fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 On caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
-142.I psf
FL9777--R11
3of4
ate of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
changes or quality assurance changes throughout the duration for which this report is valid.
nor imply warranty, installation, recommended use, or other product attributes that are not
I
I
C R K I OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl-ockO Self -Sealing Ice & Water Barriers
TECHNICAL SERviCEs, LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification. is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC; and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
'8) Design wind load pressures shall be determined for components and cladding. In accordance with FBC
1609. J
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures I for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
I '
COMPLIANCE STATEMENT I
The products evaluated herein by Zal hary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6"' Edition (2017) as evidenced iin the referenced documents submitted by the named manufacturer.
R ,%� PRY . p ��.
�'��� N sF'Fs;� 2017.10'.11
No 74021 09:06:29
-04'00'
:-�D STATE OF
C�i•,•,p P. �� Zachary R. Priest, P.E.
'�� �` •; O R I, V.••GN Florida Registration No. 74021
'tit ow
Organization No. ANE9641
CERTIFICATION OF, INDEPENDENCE
I
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor'will acquire, a financial interest in any other entity Involved In the approval process of the
product.
END OF REPORT
I
OCR14002.8a FL9777-Rl l Page 4 or 4
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein. I
2160 SW Poma Drive
Palm City, FL 34990
Compliant with Florida Building
2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: I" Nailstrip 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support. i .
Adhesive/Sealant : Bostik 91S*11 Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance; with FBC Sec.1507. ®p y
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
DESIGN PRESSURE*
-86 PSF Main field
-97.25 PSF Perimeter
FASTENER SPACING
6" O.C. 7
6" O.C.
SEAM ADHESIVE
Not required
3/16" continuous bead
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
.EQUIVALENCY. • U11897--04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safe 2;1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial ijjVmstAn My ,company manufacturing or distributing products
under this evaluation. L �gOzi,
Locke Bowden, P.E. is not owned, operated, or controll-$�.•y� ;6' {( .i� Octurer, or distributing products under this
report.
� x
• _ seal
-v •� STATE OF
r�����• F�QRlO� � a���
`ilo;" ZONAL V*--"
I
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6med..
2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufacturers installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities wfjurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017,6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 NaillStrip (26GA Steel), 16" Wide Roof Panel - Details
i
i
16"
I
—� 3/4i „
i
1 Panel Profile
I
t
+� 16" o.c.
i Deck:
15/32" or greater Plywood, or
- Wood plank
Snap Lode
For METHOD 2:
Apply 3116" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X V Min. per Table "A
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
1"
FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
I
I
Fnc4onor
15/32" or greater Plywood, or
- Wood plank
i
Isometric View
Apply 3/16" Bead Bostik 915TM Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A)