HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCElltltlNE
Planning & Development Services Department
o " Building & Code Regulations Division
.iR NP9 N300 Virginia Avenue, Fort Pierce, FL 34982 - (772).462-1553
Certification for Design Load Compliance, .
Project Name: JOHNSON DECK REPAIR
Project Address: 6003 BAMBOO DR. FORT PIERCE
Permit#: Occupancy,' Type: R Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
1. DESIGN CODE: Florida Building Code 2017 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): .—Enclosed _ Partially'Enclosed X Open
3. Risk Category: _ I X II 111 IV Exposure Category: _ B X C D
4. Design Wind Velocity 165 mph' 128 ASD N/A LRFD End Zone Width: 5 ft
S. Mean Roof Height: 20 ft Roof Pitch: 6.2s :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used:!(PSF, based on 10sgft @ 15'MRH, clearly label on all,plan openings):
16.0 16.0 16$ 32.1 32.1 N/A
Zone 1: -28.9 Zone 2: _54.5 Zone 3: -83.4 tone 4: -35.3 Zone 5: -44.9 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: N/A PSF Roof/.Live: N/A Balcony:.. N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: � N/A, PLF /.CONCENTRATED
8. Were Shear Walls Considered For Structure? _X. -
Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? _,Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
QESIGN PROFESSIONAL CERTIFICATION STATEMENT:.
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Signature, Date, and Seal
SLCCDV Form # 020-12 Revised 3j15112:(.IS)
Paul Welch P.E. 29945 / 5115
Print Name Cert.# & Co. Cert Auth.
Paul Welch Inc.
1984 S.W. Biltmore St. Suite#114 Port St. Lucie, FL
Company Name & Address