HomeMy WebLinkAboutFLOOR REPAIR CERTIFICATIONSCANNED
FROM: STEVENS. WOOD, P.E. MARCH 3, 2018
St? Q 9P.lP rN L PROFESSIONAL ENGINEER No.34398
950 SULTAN DR
PORT ST LUCIE, FL 34953
(772-878-7324)
TO: ST LUCIE COUNTY BUILDING DEP -
%y
c
SUBJECT: FLOOR REPAIR CERTIFICATION E
REFERENCE: MANUFACTURED HOME LOCATION/SPECS:
■ MANUFACTURED HOME (DOUBLE WIDE) LOCATED Cam:
• 256 CAMINO DEL RIO
• SPANISH LAKES RIVERFRONT MHP
• PORT ST LUCIE, FL
■ DATE OF MANUFACTURE: 8/23/1977
■ MOBILE S/N's: FLFL2A73333-0599A $ FLFL2A73333-0599B
■ WIND ZONE: II
BACKGROUND:
THE PURPOSE OF THIS LETTER IS TO CERTIFY THE'AS BUILT FLOOR REPAIR AT THE
MANUFACTURED HOME LOCATED AT THE ABOVE REFERENCED ADDRESS.
AN ON SITE VISUAL INSPECTION OF THE REFERENCED MANUFACTURED HOME WAS
CONDUCTED BY THIS ENGINEER ON 3/3/2018.
INSPECTION FINDINGS:
DUE TO THE ORIGINAL FLOOR EXHIBITING'SOFT SPOTS' THROUGH OUT THE MOBILE,
ALL FLOOR COVERING (CARPET/TILE/ETC) WAS REMOVED AND 5/8" CDX PLYWOOD WAS
INSTALLED OVER THE ORIGINAL PARTICLE BOARD FLOORING.
AT THE TIME OF THE INSPECTION, APPROX 90% OF THE FLOOR AREA HAD BEEN
'REPAIRED'.
THE PLYWOOD WAS ATTACHED TO EXISTING FLOOR USING 2" WOOD SCREWS AT 12
INCHES ON CENTER.
BASED ON THE INSPECTION, PHOTOS, AND DISCUSSIONS WITH THE WYNNE BLDG
REPRESENTATIVE, THE FOLLOWING FINDINGS WERE MADE FOR THIS SITE
SPECIFIC CIRCUMSTANCE:
• THE FLOOR REPAIR AS DESCRIBED ABOVE WAS FOUND TO BE
CONSTRUCTED IN A MANNER THAT WILL NOT ADVERSELY AFFECT THE
MOBILE HOME FRAME/STRUCTURE AND WILL IMPROVE THE -SAFETY OF
THE HOME AND IS THEREFORE ACCEPTABLE AS IS.