HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEM' iiY��AiC1�11PG�R7M,lr1V7' �F+x is a � . • � .� . ._ � � '� � �' ` / ...... � ,� t^�� I r � � ,
t �
r�u�si wss} & Prafess�onal Regulation '-
�1f` j. '� a y_.-. t� v 06P8HrWE A80U1"DBPA. �D9FRd'1VIDIOPI9 GOgiACTDSpR
,
Florida
rd Jo�
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
L#
Application Type
Code Version
Application Status
Comments
Archived
ProS1s"tcCAN nufac erg
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
-atego
u Sates=. ,1
Compliance Method
@,K-f 02,r-R2D
Revision
2017
Approved
RECEIVED
APR 17 2018
ST. Lucle 99wnty, mi-mitting
LI CUFY
dlTird_Built�Materials:Gc ,_LL_�
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.ruiz@tribuiltmg.com
David Ruiz
david.ruiz@tribuiltmg.com
David Ruiz
250 Route 17 North
East Rutherford, NJ,07073
(201) 842-2449
david.ruiz@tribuiltmaterialsgroup.com
C Richard Schurman
9050 Louisiana Street
Merrillville, IN 46410
rich.schurman@alliedbuilding.com
Rii�Mg
Moaified:Bi� tumen-Roof-System
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W. Knezevich, PE
1�3' Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
EL16027 R2 COI 2017 01 COI Nieminen.pdf
Standard
ASTM D6163
ASTM D6164
ASTM D6222
FM 4470
FM 4474
Year
2008
2011
2011
2012
2011
Equivalence of Product Standards
i
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/25/2017
09/30/2017
10/08/2017
12/12/2017
FL #
Model, Number or Name
Description
16027.1
TRI-BUILT Modified Bitumen Roof
SBS and APP modified bitumen roof systems
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16027 R2 II 2017 09 FINAL Al ER TRI-
Approved for use outside HVHZ: Yes
BUILT MODBIT FL16027-R2.pdf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The Design Pressure noted in this application refers
Evaluation Reports
to one system. Refer to ER Appendix for all systems and max.
FL16027 R2 AE 2017 09 FINAL ER TRI-
design pressures. 2.) Refer to ER Section 5 for Limits of Use.
BUILT MODBIT FL16027-R2.pdf
Created by Independent Third Party: Yes
Back Ne:rt
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: B50-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which an be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
aI ® e
Credit Card
Safe
��TRRINITYJ ERD
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
Page
1A-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
3A-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
113
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
6
lE-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
7
1E-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
8
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
9
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
10
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
11-14
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
14
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
15-16
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
16
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
17-19
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
20
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
21
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
SD
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
22
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
22
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
23
6B
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
24
6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
24
6D
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
24
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
25-26
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
26
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-Inch penetration.
Having Jurisdiction.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation Instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polylsocyan u rate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.10.12-112 for FL16027-RZ
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26
��TRINITYJERD
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE 1: TRI-BUILT ROOF COVERS
Reference
Layer
Material
Application
BP -AA
Base Ply
FBC Approved ASTM D4601, Type I I
HA at 20-40 Ibs/square
Ply
FBC Approved ASTM D2178,Type IV or VI
(Base and Ply. sheets, Asphalt -Applied)
SBS AA
Cap Ply
TriBullt SBS Granular
HA at 20-40 Ibs/square
(SBS, Asphalt -Applied)
SBS-TA
(SBS, Torch -Applied)
Cap Ply
TriBuiltSBS Granular
Torch Applied
5BS-SA
Base Ply
TrIBUIItSASB5 Base
Self -Adhering
Cap Ply
TrlBullt SA SB5 Cap
(5B5, Self -Adhering)
APP-TA
Base Ply or Ply
TriBullt APP Smooth
Torch -Applied
Cap Ply
TriBuilt APP Smooth, TriBuilt APP Granular
(APP, Torch -Applied)
APP-SA
Cap Ply
TriBuIItSAAPPCap
Self -Adhering
(APP, Self -Adhering)
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MCP listings below vs. those in Table 3A
applies:
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A
Option #
Primer
Barrier
Insulation Adhesive
_
MDP (psf)
TypeVapor
Attach
VB-1.
ASTM D41
TrlBuilt SA SBS Base
Self -Adhering
Inta-Stik or CR-20, 12-Inch o.c.
-60.0
VB-2.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Insta-Stik, 12-Inch o.c.
-75.0
VB-3.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Millennium One Step Foamable Adhesive, 12-Inch o.c.
-157.5
VB-4.
ASTM D41
TriBullt SA SBS Cap
Self -Adhering
CR-20, 12-Inch o.c.
-270.0
VB-5.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-Inch o.c.
-290.0
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. "MDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26
-.i TRINITY I ERD
TABLE 1E-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Base Sheet
Roof Cover (Note 15)
MDP
No.
Deck (Note 1)
Base
Fasteners
Attach
Base Ply
Cap Ply
(Psf)
Min. 19/32-Inch
Polyglass Elastobase, Polyglass Elastobase
OMG Flat Bottom Plates (square) with
12-inch o.c. In 4-inch lap and 12-Inch
(Optional) One or
W-1
plywood at max.
Poly, Polyglass G2 Base, CertalnTeed
Roofgrip #14, Dekfast Hex with Dekfast #14
o.c. In two, equally spaced, staggered
more BP -AA or
SBS-AA, SBS-
-52.5
24-Inch spans
Glasbase, Firestone MB Base, JM Perma-
or TruFast MP-3 with TruFast HD
center rows
APP TA
TA, APP-TA
ply 28, Tamko Glass Base or GAFGLAS #75
Min. 19/32-Inch
Polyglass Elastobase or Polyglass
Dekfast Hex with Dekfast #14 or TruFast MP-
12-inch o.c. In 4 Inch lap and 12-Inch
One or more SBS-
SBS-SA, APP-
W-2
plywood at max.
Elastobase Poly with poly top surface
3 with TruFast HD
o.c. in two, equally spaced, staggered
SA
SA, SBS TA or
-52.5
24-inch spans
center rows
APP-TA
Min.19/32-inch
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-inch
(Optional) One or
SBS-AA, SBS-
W-3
plywood at max.
Elastobase Poly
Roofgrip #12
o.c. in two, equally spaced, staggered
more BP -AA or
TA, APP-TA
-60.0
24-inch spans
center rows
APP-TA
Min. 19/32-inch
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
. 12-inch o.cin 4-inch lap and 12-Inch
One or more SBS-
SBS-SA, APP-
W-4
plywood at max.
Elastobase Poly with poly tap surface
Roofgrip #12
o.c. in two, equally spaced, staggered
5A
SA, SBS TA or
-60.0*
24-inch spans
center rows
APP-TA
TABLE 1F: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER
System
Roof Cover (Note 15)
MDP
No.
Deck
Primer
(Psf)
Joint Treatment
Base_ Ply
Ply
Cap Ply _
W-5
Min. 15/32-inch plywood
(Optional) ASTM D41
None
SBS SA
(Optional) SB5-5A or
SB5-5A, APP-SA, 5BS-TA
90.0
at max. 24-inch spans
APp TA
or APP-TA
W 6
Min. 15/32-Inch plywood
(Optional) ASTM D41
Plywood joints are covered with 4-Inch wide strips of TriBuilt SA
TriBuilt SA SBS Base
(Optional) SBS-SA or
SBS-SA, APP-SA, SBS-TA
-97 5
at max. 24-Inch spans
5B5 Base, rolled Into place to create continuous bond.
APP-TA
or APP-TA
Exterior Research and Design, LLC. d/b/a Trinity ERD Evaluation Report A42970.10.12-R2 for FL16027-112
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26