Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORT�-` ! �398 East Dania Beach Blvd. BUILDING DROPS Suite 338 A Perfect Solution in Every Drop Dania Beach, FL 33004 • �;r 954.399.8478 PH Certificate of Authorization: 29578 S6t �N 954.744.4738 FX contact@buiIdingdrops.com Product Eva lmr-anion Report Of JELD-WEN, inc. Premium Vinyl V-4500 Sliding Patio Door for Florida Product Approval Report No. 4820 Current Florida Building Code Method: Category: Sub — Category: Product: Material: Product Dimensions: 1— A (Certificate) Exterior Doors Sliding Exterior Door Assemblies Premium Vinyl V-4500 Slitting Patio Door PVC 280 7116" x 1201116" Prepared For: ,1E1_ -AVEN, ion, 3737 Lakeport Blvd. Mani,ath Falls, OR 97601 Prepared by: Hermes F • Norero, P.E. Florida Professional Engineer # 73778 Date: 05/08/2017 Contents: Evaluation Report Pages 1 - 3 ``,��tttF. trrrriitti ...ell O �'0,�.� �<o'RiU� i �` ••'••......•''� G\ 10NA1- E�`��`�♦ Hermes d!WWo, P.E. Florida No. 73778 I NOTI(7" ' OF PRODUCT CERT�9CATION CIER77 �q -' �R�FIEDRR�dJG�� CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: N1013706.01-121 05/08/2017 Structural JELD-WEN 1822-1 05/17/2017 To verify that the "Notice oi'Product Certification" is valid, please visit tvww.NAM ICertif ication.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN Premium Vinyl (V4500) 3737 Lakeport Boulevard Multi -Slide Sliding Patio Door Klamath Falls, OR 97601 Configuration: XXXXXX Glazing: IG-3/16" Tempered Glass/3/16" Annealed Glass/0.090" SGP Interlayer/3/16" Annealed Glass Frame: W-7130mm(250.44") 1I-3050mm(120.06") Panel: W-1290mm(50.81") 1-1-2978iiiin(117.25") DLO: W-1034mm(41.44") 1-1-2770nun(109,06") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: �2873 Pa (60 psf) Water Penetration Resistance Test Pressure: 470 Pa (9.82 psi) Large Missile Impact Rated Product Tested By: Architectural Testing, Inc. Report No: G6556.02-301-44/G6556.04-301-44 Expiration Date: January 31, 2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fat: (804) 684-5122 BUILDING DROPS. Date: Oo: 42017 Report No: 820 r t, r A Perfect Solution in Every Drop -'' Certificate of Authorization:29578 Manufacturer: JELD-WEN, inc. Product Category: Exterior Doors Product Sub -Category: Sliding Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Vinyl V-4500 Sliding Patio Door (Impact) 280 7/16" x 120 1/16" Scope: This is a Product Evaluation Report issued by Hermes Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions G6556.02, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing G6556.02 require further engineering analysis by a licensed engineer or registered architect. S. See Installation Instructions G6556.02 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 3 n Date: 0o: 42017 BUILDING DROPS 3 Report No: 820 } A Perfect Solution in Every Drop Certificate of Authorization: 29578 Certification Agency: The manufacturer has demonstrated compliance of window products in Accordance with the Florida Building Code and State Rules for manufacturing under a Certification Agency through National Accreditation & Management Institute (FBC Organization #CER1773) Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by Architectural Testing, Inc. (FBC Organization # TST2609) Report #: G6556.02-301-44, Report Date: 04/11/2017 Installation: 2. Certification Agency National Accreditation & Management Institute (FBC Organization #: CER1773) 3. Material Certification Miami -Dade RER — Product Control Section NOA Kuraray America, Inc.: SentryGlas Plus Interlayer 4. Material Certification Miami -Dade RER — Product Control Section NOA Quanex Building Products, Inc.: PVC Extrusions Refer to Installation Instructions (G6556.02) for anchor spacing and more details of the installation requirements. Design Pressure: _ Design Pressure Positive 60 PSF LNegative 60 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 3