Loading...
HomeMy WebLinkAboutPRODUCT APPROVALSCANNED t3 � � L49 0 r v yy o �s n a .�� JI., i . BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Florida `TO ') Product Approval .USER: Public User v?yc�i<tNNrr,,��rC2 Cpr�:>x�Prqusm Product Approval Menu > Product or Application Search > Application List > Application Detail E? g"o-moo; FL I S R27 Application Type Code Version Application Status Comments Archived N& �Manufact- u Address/Phone/Email Authorized Signature %Wk9- Revision 2017 Approved &—OUY,GL:ASSiUSAR i' 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext 242 alender@polyglass.com Ariel Lender a lender@polyglass -corn 7RECEIVED APR 17 2018 ST. Lucie County, Permitting Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center D Deerfield Beach, FL 33442 (912) 429-8610 COP) MAlpert@polyg lass.com FILE Quality Assurance Representative Ariel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@ polyg lass.co m �Catego1-rmMin Subcategof-y nde a rse Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/05/2018 Validated By John W. Knezevich, PE D Validation Checklist - Hardcopy Received Certificate of Independence FL5259 R27 COI 2017 01 COI Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products i TAS 110 UL 1897 I i I i i I I I Method 1 Option D 09/14/2017 09/15/2017 09/18/2017 i 12/12/2017 01/24/2018 2000 2012 FL * Model, Number or Name bescription 5259.1 Polyglass Roof Roofing underlayments Underlayments 1 Limits of Use Approved for use in HVHZ:No 'Installation Instructions IFL5259 R27 II 2017.09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R27. cp if Approved for use outside HVHZ: Yes Impact Resistant: N/A 'Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular FL5259 R27 AE 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R27.pift underlayment system (over concrete deck) for use under foam -on tile systems (where the Created by Independent Third Party: Yes underlayment forms part of the load -path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. I Back Wext Contact Us :: 2601'Blair Stone Road, Tallahassee FL 32399 Phone: 850-497-1824 1 The State of Florida is an AA/EEO employer. a yright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Rerund Statement Under Florida law, email addresses are public records. If you Ido not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emaits provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe i `.!TRINITY (ERD EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 98408 (570) 384-1230 EXTERIOR RESEARCH &,DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report P12060.02.09-1123 FL5259-R27 Date of Issuance: 02/24/2009 Revision 23: 09/14/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and• the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6`h"Edition (2017) Florida Building Code sections noted herein. DESCRIF!TION7 POIygIOss Roof'Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded] by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/14/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity) ERD nor, Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. .Entity ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ICC-ES (EVIL 2396) Miami -Dade (CER 1592) Polyglass USA Polyglass USA Polyglass USA UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: Examination Physical Properties Physical Properties; Physical Propertiesi Wind Uplift Physical Propertiesi Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physical Properties Physical Properties IBC Compliance i HVHZ Compliance Manufacturing Affidavit PA Affidavit Materials Affidavit Quality Control Reference P40390.08.12-1 P40390.08.12-2 C41420.09.12-3 P39680.03.13 P45370.04.13 P1738.02.07-R2 11757.04.01-1-R1 P41630.08.13 P11751.05.03-R1 P11781.11.03-R1 P45270.05.14 6020.07.14-1 6020.09.14-2 6020.09.14-3 6020.09.14-4 6020.09.14-5 6020.09.14-6 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC7550.03.15 P40390.04.15 PLYG-SC8080.05.15-1 PLYG-SC8905.05.16-1 PLYG-SC8080.07.16 PLYG-SC12025.10.16 PLYG-SC13040.12.16 PLYG-SC11900.03.17 PLYG-SC12115.08.17 ESR-1697 NOA 14-0717.08 Products Current Mule -Hide Cross Ltg Polystick SA Compound Service Confirmation 4.1. Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 1 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. Date 08/06/2012 08/07/2012 09/11/2012 03/04/2013 04/26/2013 04/29/2013 04/30/2013 08/06/2013 11/26/2013 11/26/2013 05/12/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 10/03/2014 10/07/2014 10/17/2014 03/24/2015 04/03/2015 05/20/2015 05/17/2016 07/16/2016 10/12/2016 12/27/2016 03/10/2017 08/08/2017 11/01/2014 01/22/2015 02/18/2009 03/01/2008 08/18/2011 Exp. 10/05/2018 4.2= • Self -Adhering Underlayments: 4.2:1 Polystick NITS Is a nominal , 60 mll-thick rubberiied asphalt waterproofing membrane, glass"fiber relnforcetl,: surfaced withpolyolefinicfilmsurface;meetsTAS103. , 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 3 of 14 I — I y TRINITY 1 ERD 5.5 Allowable Roof Covers: TABLE!: ROOF COVER OPTIONS ' Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes Shingles State& Elastobase Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Elastobase P Yes Yes I (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Polyglass G2 Base No Yes (Base Sheet in 2-ply system) I Yes (Base Sheet in 2-ply system) No No No Polyglass APP Base No Yes IYes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) No No No Polystick-MTS Yes Yes.` No • Yes 'Yet Yes ' Polystick I R-Xe Yes No No No Yes Yes Polystick TU P Yes Yes Yes (See 5.5-1) No Yes Yes PolystickTU Plus Yes Yes Yes (See 5-5.1) Yes Yes Yes PolystickTU Max No Yes Yes (See 5.5-1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex 56 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Underlayments Approval DAP Foam Touch 'n Seal StormBond Roof FL14506 Polystick TU Plus, Polystick TU Max Tile Adhesive DowTileBond- FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polyglass Polyl-ok Roof Tile Adhesive FL17855 ! Polystick TU Plus or Polystick TU Max I 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23 Certificate ofAuthorization s9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017 Page 5 of 14 5.6 5.6.1 5.6.2 5.6.3 Allowable Substrates: Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyfle (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed nE .plywood; New or existing, unprimed OSB; A� Southern Yellow Pine; ASTM D41 primed st% (designed and installed to meet wind loads for T�k',NITYJERD SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet untreated plywood; Existing plywood; ASTM D41 primed existing FM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed ctural concrete; Huber Engineered Woods "ZIP System" Panels roj ect). Note: Polyglass does not require priming of new lor existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and depris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G IIFR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, I ule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: I ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval: For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: j ➢ ASTM D226, Type I or II felt; Elastobase; ElastoI base P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule=Hide Nail Base,l Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under ifoam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. 1 Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23 Certificate of Authorization#950.3 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27 Polyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017 I Page 6 of 14 I\ F)o TRII I-ff I ERD 5.9 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment i� direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK'TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged j 8-tile stack (6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Flat or Lugged Prohibited without battens N/A Polystick Tile Pro Flat or Lugged I 6-tile stack (4 over 2) 7:12 PolystickTU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 PolystickTU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 PolystickTU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR t7777Flit or Lugged ! 6-tile stack (4 over 2) 4:12 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 . Elastobase, Elastobase P or Mule -Hide Nail Base:_ 6.3.1 Non -Tile Applications: Shall be installed in compliance with the codifiel requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APPI Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23 Certificate ofAuthorization#9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 11 of 14 6.4.1 6.4.2 6.4.3 6.4.4 rQ_ \.f TRINITYIERD Shall be installed in compliance with the codified (requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FIR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide Back Nailing Guide. Nails shall be corrosion 'resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). of Ovelao Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened the roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set the applications, refer to Section 5.6.4 herein. For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile. Two (2) Ply Underlayment Systems: Polystick MTS followed by Polystick MTS, TU P1 TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2'ply underlayment system is desired. Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION F1.5259-1127 Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017 Page 12 of 14 r - � BCIS Home Log In User Registration I Hot Topics Submit Surcharge I Stats & Facts Publications FBC Staff BCIS Site Map Links I Search a dbpr s c Product Approval ,USER: Public User Pt� kv _.._ .. Product Approval Menu > Product or Application Search > Application List > Application Detail 511 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived 0 rgduct,'Manufacturer—r reme le al "Eabricators , RC--j Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com 'Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 rchard@emfab.net Quality Assurance Representative Address/Phone/Email W ory.:Roging�" �ubcate"goLy etalFRoofing�*~ Compliance Method I Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. 9 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.Qdf Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 Sections from the Code i Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 FL Model, Number or Name 17022.1 1 - "5V Crimp" (R6) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A j Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Description 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pd Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf Created by Independent Third Party: Yes 17022.2 2 - "5V Crimp" (116) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions.Install the assembly in compliance with the installation method listed in FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 3 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24aa ssr.odf Impact Resistant:.No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A j Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL installation method listed in this report and applicable code seam 24ga ssr.pdf sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.4 4 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.p_df Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM installation method listed in this report and applicable code ALUMINUM ssr.pdf sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 17022.5 5 - "1 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports i -.. _. i 2160 SW Poma Drive Palm City, FL 34990 _ _ . '(772)872-8034 Compliant with Florida Building Code 2017 (6' ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications ro u : 5 Ycrimp,215153X-steermootane ec. .. v: Yield strength: 150, ksl rriln:• Attached" to min.15/32"plywood or Wood Deck w/ min '0A2 specific gravity with screws. �24" Coverage, Rib Heght.3%8,,. G on ec. Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.15'07. See Fastener attachment specifications above Install Details:' Table A, Allowable Loads ' ' "METHOD 1 `° '� METHOD 2 METHOD 3 METHOD 4 , ,DESIGN PRESSURE* -86, PSF -93.5 PSF -101 PSF -228 PSF ROW 'SPACING. ; 16" o-c. ' , ; 16" ox. 8" O.C. 6" o.c. FASTENER'SPACING`(ALONG.Panel'width) 22" M ;" ° ; 12".o.c. 12" o.c. 12" ox. FASTENER SIZE',.. , . #9 , �, 7 _#20 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 2527 UL 580-06 & 1897-041 Test Report ISS93.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to teststandard UL 1897-12 *Design pressure margin ofsafety 2.1 'nfnFlo Locke Bowden, P.E. does not have, not will acquire a financial in ,-_� io •s •'�,,r��►m,�%ifacturin or distributing products under this evaluation. = °� � � g •. �.r g g Locke Bowden, P.E. is not owned, operated, or controlled by air coaiparloommlafahuret, or distributing products under this report. .`. , ; ,? i � XT �4 Y ��./ 1 _ PL17022.1 6V 6`hMp (26GA Steel), 24" Wide Roof Pall - Details Lirriitations 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 15132 or greater Plywood, or Wood plank 24- 1� 318" PFMONALSTRIAMONS Panel Profi,14 _ �f:. Nominal 12" Nominal 12' O.C. O.C. Fasten f9 x 1-1/2" Min. or #10 x 1-1/2" Min. per ?Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Width Panel RePanel g Refer toTab a 'A' for Spacing Along Panel Overlap (Length I Deck15/32" or greater Plywood, or - Wood plank