Florida
`TO
') Product Approval
.USER: Public User
v?yc�i<tNNrr,,��rC2
Cpr�:>x�Prqusm
Product Approval Menu > Product or Application Search > Application List > Application Detail
E? g"o-moo; FL I S R27
Application Type
Code Version
Application Status
Comments
Archived
N& �Manufact- u
Address/Phone/Email
Authorized Signature
%Wk9-
Revision
2017
Approved
&—OUY,GL:ASSiUSAR i' 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1378 Ext 242
alender@polyglass.com
Ariel Lender
a lender@polyglass -corn
7RECEIVED
APR 17 2018
ST. Lucie County, Permitting
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center D
Deerfield Beach, FL 33442
(912) 429-8610 COP)
MAlpert@polyg lass.com
FILE Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1230
ALender@ polyg lass.co m
�Catego1-rmMin
Subcategof-y nde a rse
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/05/2018
Validated By John W. Knezevich, PE
D Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R27 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D6164
2011
ASTM D6222
2011
FM 4474
2011
FRSA/TRI April 2012
2012
TAS 103
1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
i
TAS 110
UL 1897
I
i
I
i
i
I
I
I
Method 1 Option D
09/14/2017
09/15/2017
09/18/2017
i
12/12/2017
01/24/2018
2000
2012
FL *
Model, Number or Name
bescription
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
1
Limits of Use
Approved for use in HVHZ:No
'Installation Instructions
IFL5259 R27 II 2017.09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R27. cp if
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
'Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular
FL5259 R27 AE 2017 09 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R27.pift
underlayment system (over concrete deck) for
use under foam -on tile systems (where the
Created by Independent Third Party: Yes
underlayment forms part of the load -path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
I
Back Wext
Contact Us :: 2601'Blair Stone Road, Tallahassee FL 32399 Phone: 850-497-1824
1
The State of Florida is an AA/EEO employer. a yright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Rerund Statement
Under Florida law, email addresses are public records. If you Ido not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have
one. The emaits provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Credit Card
Safe
i
`.!TRINITY (ERD
EVALUATION REPORT
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 98408
(570) 384-1230
EXTERIOR RESEARCH &,DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report P12060.02.09-1123
FL5259-R27
Date of Issuance: 02/24/2009
Revision 23: 09/14/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and• the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6`h"Edition (2017) Florida Building Code sections noted
herein.
DESCRIF!TION7 POIygIOss Roof'Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded] by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/14/2017. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor, Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
.Entity
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ICC-ES (EVIL 2396)
Miami -Dade (CER 1592)
Polyglass USA
Polyglass USA
Polyglass USA
UL, LLC. (QUA9625)
4. PRODUCT DESCRIPTION:
Examination
Physical Properties
Physical Properties;
Physical Propertiesi
Wind Uplift
Physical Propertiesi
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
IBC Compliance i
HVHZ Compliance
Manufacturing Affidavit
PA Affidavit
Materials Affidavit
Quality Control
Reference
P40390.08.12-1
P40390.08.12-2
C41420.09.12-3
P39680.03.13
P45370.04.13
P1738.02.07-R2
11757.04.01-1-R1
P41630.08.13
P11751.05.03-R1
P11781.11.03-R1
P45270.05.14
6020.07.14-1
6020.09.14-2
6020.09.14-3
6020.09.14-4
6020.09.14-5
6020.09.14-6
P46520.10.14
P44360.10.14
P43290.10.14
PLYG-SC7550.03.15
P40390.04.15
PLYG-SC8080.05.15-1
PLYG-SC8905.05.16-1
PLYG-SC8080.07.16
PLYG-SC12025.10.16
PLYG-SC13040.12.16
PLYG-SC11900.03.17
PLYG-SC12115.08.17
ESR-1697
NOA 14-0717.08
Products Current
Mule -Hide Cross Ltg
Polystick SA Compound
Service Confirmation
4.1. Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
1
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
Date
08/06/2012
08/07/2012
09/11/2012
03/04/2013
04/26/2013
04/29/2013
04/30/2013
08/06/2013
11/26/2013
11/26/2013
05/12/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
10/03/2014
10/07/2014
10/17/2014
03/24/2015
04/03/2015
05/20/2015
05/17/2016
07/16/2016
10/12/2016
12/27/2016
03/10/2017
08/08/2017
11/01/2014
01/22/2015
02/18/2009
03/01/2008
08/18/2011
Exp. 10/05/2018
4.2= • Self -Adhering Underlayments:
4.2:1 Polystick NITS Is a nominal , 60 mll-thick rubberiied asphalt waterproofing membrane, glass"fiber relnforcetl,: surfaced
withpolyolefinicfilmsurface;meetsTAS103. ,
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 3 of 14
I —
I y
TRINITY 1 ERD
5.5 Allowable Roof Covers:
TABLE!: ROOF COVER OPTIONS '
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Shingles
State&
Elastobase
Yes
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes I
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes
(Base Sheet in 2-ply system)
I
Yes
(Base Sheet in 2-ply system)
No
No
No
Polyglass APP Base
No
Yes IYes
(Base Sheet in 2-ply system)
(Base Sheet in 2-ply system)
No
No
No
Polystick-MTS
Yes
Yes.`
No •
Yes
'Yet
Yes '
Polystick I R-Xe
Yes
No
No
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes (See 5.5-1)
No
Yes
Yes
PolystickTU Plus
Yes
Yes
Yes (See 5-5.1)
Yes
Yes
Yes
PolystickTU Max
No
Yes
Yes (See 5.5-1)
Yes
No
No
Polystick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex 56 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE
IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS)
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch 'n Seal StormBond Roof
FL14506
Polystick TU Plus, Polystick TU Max
Tile Adhesive
DowTileBond-
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass Polyl-ok Roof Tile Adhesive
FL17855 !
Polystick TU Plus or Polystick TU Max
I
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificate ofAuthorization s9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017
Page 5 of 14
5.6
5.6.1
5.6.2
5.6.3
Allowable Substrates:
Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyfle
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed nE
.plywood; New or existing, unprimed OSB; A�
Southern Yellow Pine; ASTM D41 primed st%
(designed and installed to meet wind loads for
T�k',NITYJERD
SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
untreated plywood; Existing plywood; ASTM D41 primed existing
FM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
ctural concrete; Huber Engineered Woods "ZIP System" Panels
roj ect).
Note: Polyglass does not require priming of new lor existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and depris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G IIFR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, I ule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
I
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval: For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to: j
➢ ASTM D226, Type I or II felt; Elastobase; ElastoI base P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule=Hide Nail Base,l Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under ifoam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1. 1
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#950.3 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments, (570) 384-1230 Revision 23: 09/14/2017
I Page 6 of 14
I\
F)o
TRII I-ff I ERD
5.9 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment i� direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS
FOR DIRECT-DECK'TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
j
8-tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS
Flat or Lugged
Prohibited without battens
N/A
Polystick Tile Pro
Flat or Lugged I
6-tile stack (4 over 2)
7:12
PolystickTU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
PolystickTU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
PolystickTU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
t7777Flit or Lugged !
6-tile stack (4 over 2)
4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 . Elastobase, Elastobase P or Mule -Hide Nail Base:_
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codifiel requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APPI Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certificate ofAuthorization#9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ7
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 11 of 14
6.4.1
6.4.2
6.4.3
6.4.4
rQ_
\.f TRINITYIERD
Shall be installed in compliance with the codified (requirements for ASTM D1970 underlayment in FBC Table 1507.1.1
for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FIR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion 'resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
of Ovelao Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened the roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set the applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
Two (2) Ply Underlayment Systems:
Polystick MTS followed by Polystick MTS, TU P1 TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2'ply underlayment system is desired.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION F1.5259-1127
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 12 of 14
r
-
�
BCIS Home Log In User Registration I Hot Topics Submit Surcharge I Stats & Facts Publications FBC Staff BCIS Site Map Links I Search
a
dbpr
s c Product Approval
,USER: Public User
Pt� kv
_.._ ..
Product Approval Menu > Product or Application Search
> Application List > Application Detail
511
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
08/18/2017v. date reapply 08/21/17
Archived
0
rgduct,'Manufacturer—r
reme le al "Eabricators , RC--j
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
'Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
W
ory.:Roging�"
�ubcate"goLy etalFRoofing�*~
Compliance Method I Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
9 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.Qdf
Standard
Year
TAS 125
2003
UL1897
2012
UL 580
2006
Sections from the Code
i
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
FL Model, Number or Name
17022.1 1 - "5V Crimp" (R6)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A j
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
Description
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Installation Instructions
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pd
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
Created by Independent Third Party: Yes
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions.Install the
assembly in compliance with the installation method listed in
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 3 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes seam 24aa ssr.odf
Impact Resistant:.No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A j Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and Evaluation Reports
limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
installation method listed in this report and applicable code seam 24ga ssr.pdf
sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.p_df
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code
ALUMINUM ssr.pdf
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.5 5 - "1 in. Nail Strip" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
i
-.. _.
i
2160 SW Poma Drive
Palm City, FL 34990
_ _ . '(772)872-8034
Compliant with Florida Building Code 2017 (6' ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
ro u : 5 Ycrimp,215153X-steermootane ec. ..
v:
Yield strength: 150, ksl rriln:• Attached" to min.15/32"plywood or Wood
Deck w/ min '0A2 specific gravity with screws. �24" Coverage,
Rib Heght.3%8,,. G
on
ec.
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.15'07.
See Fastener attachment specifications above
Install Details:' Table A, Allowable Loads '
' "METHOD 1 `°
'� METHOD 2
METHOD 3
METHOD 4 ,
,DESIGN PRESSURE*
-86, PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW 'SPACING. ;
16" o-c. ' , ;
16" ox.
8" O.C.
6" o.c.
FASTENER'SPACING`(ALONG.Panel'width)
22" M ;"
° ; 12".o.c.
12" o.c.
12" ox.
FASTENER SIZE',.. , .
#9 , �,
7 _#20
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 2527
UL 580-06 & 1897-041 Test Report ISS93.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to teststandard UL 1897-12 *Design pressure margin ofsafety 2.1
'nfnFlo
Locke Bowden, P.E. does not have, not will acquire a financial in ,-_� io •s •'�,,r��►m,�%ifacturin or distributing products
under this evaluation. = °� � � g •. �.r g g
Locke Bowden, P.E. is not owned, operated, or controlled by air coaiparloommlafahuret, or distributing products under this
report. .`. , ; ,?
i
� XT �4 Y ��./
1
_ PL17022.1 6V 6`hMp (26GA Steel), 24" Wide Roof Pall - Details
Lirriitations
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
15132 or greater Plywood, or
Wood plank
24-
1�
318"
PFMONALSTRIAMONS
Panel Profi,14
_ �f:.
Nominal 12" Nominal 12'
O.C. O.C.
Fasten
f9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
?Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the
Width
Panel RePanel g Refer toTab a 'A' for Spacing Along Panel
Overlap (Length
I
Deck15/32" or greater
Plywood, or