Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
INSTALLATION REQUIREMENTS
.s W z aE x< wz 0, Z� N OW !�w 00. 3w 0 U o� V)LLI ww mo z 81 0°d �w w� f� a z� ON MN o z IO a v, " U 0z 0 ww My 5w z,,, O w 0 CL U a>- �(y w N � �o U) zw wa w� IL 0 O 3 EL en Z� W J w �z �w Pir H U Z 0 to Z Z 00 ma N ow 00 �a W o� Li Fr F-3 ZOZ U 6 � a z� ww 5F: U os 0 O N r3 6 M1I�''1I V 1 tl ED �� �) � 9�eBY ARRAY AREA OUNTED) ARRAY WIRING CONTINUES, OR TRANSITIONS INTO MC CABLE OR BUILDING WIRE IN BONDED METAL RACEWAY WHERE REQUIRED PER [G90.3 I (G)l I I I �I I I I I I I I �I I L------------------------------ J 0 o BONDED MODULES, OPTIMIZERS, AND RAILS PER UL 2703 RIOR OR EXTERIOR WALL SOLAREDGE 3.8kW 240Vac 5E35OOH-US INVERTER, WITH INTEGRAL do DISCONNECT (N3R) - CKT 1 CKT 1 (+) AC CONDUCTOR AND RACEWAY SCHEDULE L1 L2 N 30A ADJACENTac DISCONNECT (OPTIONAL, UNLESS [G90. 1 51 REQUIRES) ONE PV MODULE PERSOLAPEDGE P30Q/P32O INSTALLATION REQUIREMENTS: OPTIMIZER. CONTRACTOR TO VERIFY FIELD CONDITIONS AND REPORT CIRCUIT 1: 17 MODULES DISCREPANCIES TO ENGINEER. TOTAL: 17 MODULES MANUFACTURER -PROVIDED INSTRUCTIONS AND TORQUE DC SYSTEM SIZE: 4930 WDC REQUIREMENTS TO BE FOLLOWED FOR ALL LISTED EQUIPMENT. ALL WORK TO BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 2014 AND ANY LOCAL AHJ OR UTILITY REQUIREMENTS. MAIN PANELBOARD LOCATION (NOT SUITABLE FOR ALL -IN -ONE PANELBOARD INTERCONNECTION) CONNECTIONS MADE WITH POLARIS IPL CONNECTORS, INSULATION -PIERCING CONNECTORS OR SIMILAR TIER I PV SYSTEM DISCONNECT 240Vac GOA 3R IN AC DISCONNECT FUSED AT 20A IFF SYMBOL CIRCUIT 310.15(B) TEMPERATURE ADJU5TED REQUIRED 5ET5 MATERIAL N5UTATION RACEWAY 51ZE(AWG) QTY CONDUCTOR I -WAY RUN VOLTAGE AMPACITY RACEWAY FILL AMPACITY AMPACITY DROP OPV MODULE WIRING 40A 55-C (0.7G) 30AA I& x 1.25) 1 Cu GOOV PV FREE AIR. 12 I DC+ 23 Imp@28VDC: (INTEGRATEDBYMANUFACTURED WA 12.OA<30.44 5UPPORTED I DC- 0.31% O PV OPTIMIZER DC OUTPUT CIRCUIT 40A 55°C (0.7G) 30AA (max) L_ Cu GOOV PV FREE AIR, 12 I DC+ 3, 1350VI WA I5A 3 <0T4A — __ _ 5UPPORTED I DC- 0.05% O PV DC OUTPUT CIRCUIT WRING 40A 55°C (0.7@ 30.4A" (Imax) I CU GOOV PV FREE AIR, 12 12 1 1 DC+ 3d [350VI WA I5A < 30.4A 5UPPORTED 10 1 BARE G 0.51 % O PV DC OUTPUT CIRCUIT WIRING 35A 55°C (O.G7) IE.8A (Iwo I Cu THWN 3/4' METAL 10 10 1 1 DC+ IOd [350VI (75°C) 0.8 I5A < 18.8A (BONDED) I.00% 10 1 G O INVERTER OUTPUT CIRCUIT 35A (75°C) 45°C (0.82) 29A (Imax x 1.25) I Cu THWN 3/4' 10 I N 3d [240VJ 1.0 (75°C) I GA x 1.25 < 29A 0.52% 10 1 G OELECTRIC POWER PRODUCTION 45°C (0.87) 1 Cu ThWN-2 2 A [2 SOURCE CONDUCTORS 75A 90°C) (75 C) 1230.42(B)1 (BOND D) 8 N F055 BLE 0.OE)% G GROUNDING ELECTRODE CONDUCTOR WA WC A WA WA I CuCU BARE OR NONE G, OR PER [250.GG) 1 GEC F055115LE A5 5HORT AS A WA " GO°C RATED TERMINALS, OR TERMINALS WITHOUT A LABELED RATING, MAY NOT BE USED. EXISTING 240V I P3W SERVICE N L1 I L21 EXISTING LOADS ARRAY AND STRUCTURE GROUNDING: ALL MODULES, OPTIMIZERS, AND RAILS TO BE BONDED USING UL 2703 LISTED HARDWARE. RAILS BONDED TO # 10 (MIN.) BARE COPPER GROUNDING WIRE USING BURNDY WEEB-LUG-G.7 OR OTHER MANUFACTURER -APPROVED LISTED HARDWARE. MODULE SPECIFICATIONS: HYundal HI5-5290RG Pmp 29OW; Vmp 32.OV; Imp 9. 1 A; Voc 38.8V; I5C 9.7A; Max Fuse 20A TC5: Pmp-0.42°!o/°C, Voc-0.30%/°C SIMILAR 280-295W UL LISTED MODULES MAY BE SUBSTITUTED UPON OWNER'S APPROVAL. Min. Module Operating Voltage: (Vmp @55°C) 32.0 x (I - 0.0042 x +301) = 28.OV Max. Module Voltage: (lowest temp 0°C) 38.8 x (I - 0.0030 x -250) = 4 1 .7V OPTIMIZER OPERATING RANGE: 8-48V (ok) EXISTING AC SCOPE OF WORK: GROUNDING A PV SYSTEM COMPRISED OF HYUNDAI MODULES AND A ELECTRODE SOLAREDGE SE380OH-U5 INVERTER. INTERCONNECTION TO OCCUR VIA SUPPLY-SIDE CONNECTION (E 10 1) OR =SIDE_CONNECTION (E 102), AS DETERMINED BY STALLER BASED ON SITL vE CONDITIONS. --- i a 2' INTERCONNECTION REQUIREMENTS: INVERTER INTERCONNECTION SHALL BE DONE IN A MANNER PROHIBITING THE BACKFEED OF A GENERATOR. DRAWING LIST: E 101 : THREE LINE DIAGRAM (SUPPLY SIDE) E 102: LABELING REQUIREMENTS SEAL - ;i - REV. DATE REVISION DESCRIPTION DIM CHK APP 4155 St Johns Pkwy, Ste 1100 Sanford, FL 32111 • • • 4012686455 Engineer: David K Click, PE FL COA: *31310 NABCEP PIP: 0041104-05 CLIENT NAME: Barnes Residence 00 2013-04-12 INITIAL RELEASE Dc Dc Dc ADDRESS: 1300 W Ist St, Fort Pierce, FL, 34982 IPIROJECT NAME: HYUNDAI / 5E3(500 PV 5Y5TEM PV SYSTEM SIZE: 493OWDC STC / 3800WAC CONTINLIOU6 SHEET TITLE: THREE LINE DIAIG�RAM (SUPPLY SIDE) SCALE . NT6 FORMAT II' x III DRAWI NG N° DATE 20I8-04-I2 W= 0 J 3 z 0 a� y W� Z N W Z W, I� of IZ W U o Z E N 20 �i 2 o_ o 2a W o� W� 3 c �n !i6 �W 0 05 0 O N �3 ALL LABELS TO COMPLY WITH (FFPCJ OR [2014 NEC 110.21(B)] A5 APPLICABLE, LABELS SHALL BE OF SUFFICIENT DURABILITY TO WIT115TAND THE ENVIRONMENT INVOLVED. AT EACH DC JUNCTION BOX: (690.35(F)] LABEL WARNING;,ELEGTRIC SHOCK HAZARD THE DC CON DUCTOR5:OF'ITH15 PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ALONG INDOOR/OUTDOOR EXPOSED DC WIRING A-T-(MAX:)==1`O' INTERVALS: (G90.3-1(G)]--A6D'`FFPC 11. 12.2. 1.3.21 PHOT©VOLTAIC' POWER SOURCE t_' N- AT DC' DISCONNECT: (G90.1-5]-OC-015CONNECT LABEL SOLAR DC DISCONNECT AT IN\/FRTFR: (690.531 PV POWER 5OURCE DC RATING RATED CURRENT AT MAXIMUM POWER: 14. 1 A RATED VOLTAGE AT MAXIMUM POWER: 350V MAXIMUM SYSTEM VOLTAGE; 500V MAXIMUM SYSTEM CURRENT: 1 5A **CONTRACTOR TO_ MODIFY TO MATCH FIELD CONDITIONS** RATED CURRENT = (STC ARRAY RATING) / 350V MAXIMUM SYSTEM CURRENT = 1 5A x (# DC INPUT CIRCUITS) AT AC DISCONNECTS: (G90. l 51 SOLAR AC DISCONNECT AT PV INTERCONNECTION POINT: (690.541 PV POWER SOURCE AC RATING RATED CURRENT: I GA RATED VOLTAGE: 240V AT MOST ACCESSIBLE PV SYSTEM AC DISCONNECT, AND AT UTILITY SERVICE DISCONNECT: (705. l 01 015CONNECT LOCATIONS SYSTEM SPECIFIC. COULD INCLUDE EITHER CLEAR TEXT DE5CRIPTION OR A MAP OF SITE DESCRIBING LOCATIONS OF BOTH DISCONNECTS: 1) UTILITY SERVICE DISCONNECT AND 2) PV SYSTEM DISCONNECT (TWO PLACARDS REQUIRED IF DISCONNECTS ARE NOT CO -LOCATED) AT EXTERIOR MAIN PV DISCONNECT: (20l4 090. l 21 RAPID SHUTDOWN 015CONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN (This placiue or directory shall be reflective, with all letters capitalized and having a minimum height of 3/6", in white on red background.) PHOTOVOLTAIC DISCONNECT (This plague or label shall have contrasting color with capital letters at least 3/8" in height and in a n0n5erif font) WARNING: PHOTOVOLTAIC POWER SOURCE (This plague/label shall be reflective red, with white capital letters at least 3/4" in height and in a non5erif font) PV INSTALLER INFORMATION 51GNAGE PER FFPC 1 1. 1 2.2. 1 .5 COLOR CODING: DC+: RED OR ORANGE DC-: BLACK OR BLUE GROUND: GREEN OR BARE AC LI : BLACK; 1-2: RED; N: WHITE OR GREY DRAWING LIST: E 10 1 : THREE LINE DIAGRAM (SUPPLY SIDE) E 102: LABELING REQUIREMENTS SEA Zl (4 > > �- ,y: -. FEV. DATE REVISION DESCRIPTION DRII CHK APP 4155 St Johns Pkwq, Ste 1100 SanFord, FL 32111 s • • 401.268.6455 An Engineer: David K CIIcK PE FBPE: *14642 FL GOA: 131310 FL CILB: CVC 56919 NABCEP PVIP: *041104-08 CLIENT NAME: Barnes Residence SCALE NT5 00 2018-04-12 INITIAL RELEASE DC Dc Dc ADDRESS: 1300 W Ist St, Fort Pierce, FL, 34982 FORMAT II' x 11' PROJECT NAME: HYUNDAI SE3000 PV 5Y5TEM DRAWING 9 E102 PV SYSTEM SIRE: 4930Wpc STc / 3800WAc CONTINUOUS SHEET TITLE: A I I LA5ELING REQUIREMENTS DATE 2018-04-12