Loading...
HomeMy WebLinkAboutINVERTERS PRODUCT DESCRIPTIONA � _ solar -.. Single Phase Inverters for North America RECEIVED APR 13 2018 SCfl �Xr�t V Department 6't �;� le Countv BY St 1(IP'IPCIIJ1MI, SE3000H-US / SE380OH-US / SE5000H-US / oiar ••_ �® Solari � � - , 2 0000 Y. vr- 1 �`" ' ��,rt.o=...:-_..,-��+�. 9 , ♦ !fit Optimized installation''�th HD-Wave,technology ; Specifically designed to work,wth povier optimizers - - Record -breaking efficiency Fixed voltage inverter for longer strings; ' v 'Integrated arc fault protection and rapid shutdown for NEC2,014-and 2017, per article 690.11 and 690.12 UL1741 SA certified,, for CRUC Rule 21 grid compliance USA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE>BELGIUM•TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY-SWEDEN- www.5olaredge.u5 SOUTH AFRICA-POLAND-CZECH REPUBLIC Single Phase Inverters for North America solar=@@ SE3000H-US,SE3800H-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US SE3000H-US SE38001-1-US I SE5000H-US I SE6000WU5 I SE760OH-US I SE30000H-US OUTPUT I Rated AC Power Output 3000 3800 . 5000 6000 7600 10000 VA .... ...................... Max: AC Power Output 3000 3500 5000 6000 7600 10000 VA AC Output Voltage Min.-Nom.- ✓ ✓ ✓ ✓ ✓ . ✓ Vac.... .Manf211-240': 264).............. AC Frequency (Nominal) 59.3 - 60 - 60.51t1 Hz..... Maximum Continuous Output ......... .............. ............. . .. 12.5 16 21 25 32 42 A ............................................................................................................................ GFDI Threshold 1 A ........................................................:.............................................................................................. Utility Monitoring, Islanding ........... Protection, Country Configurable Yes Thresholds 1 INPUT i Maximum r .................. ........................ 4650...... ...... I...... 5900....... I,...... 7750.......I.....9300 ....... I ...... 11800...... I...... ...... .DC..Powe Transformer -less, Un rounded Yes ....... Maximum Input Voltage ............................................................................ 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum InputCurrent@240V ....... . $ 5..........10:5..............13:5..............16:5....... ........?........�.................. ... Adc.... Max: Input Short Circuit Current 45 Adc ............. Reverse:Polarity Protection ..................................................................... Yes ............................................................................................................................................... Ground -Fault Isolation Detection 600ko Sensitivity ... ............................................... Maximum Inverter Efficiency ...... .. .................................................. ................ . .. 99 99.2 ..... ................................. CEC Weighted Efficiency ................................................................. 99............................................................. ..... ......................... Nighttime Power Consumption . ....................... < 2.5 W 'ADDITIONAL FEATURES Supported Communication RS485, Ethernet, ZigBee (optional), Cellular (optional) Interfaces .......... ............... ............ ...................... ....... ...... ....... ... . . . . Revenue Grade Data, ANSI C12.20.....................................................Optionall2i......................................................................................... ........... Rapid Shutdown -NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 'STANDARD COMPLIANCE Safety UL1741. UL1741 SA, UL1699Br CSA C22.2f Canadian AFCI according to T.I.L.M-07 ................................... Grid Connection Standards IEEE1547: Rule 21, Rule 14 (HI) ....... ................ Emissions FCC Part 15 Class B AC Output Conduit Size / AWG 3/4" minimum / 20-4 AWG Ran.Be.................................................................................................................................. ................... DC Input Conduit Size / # of Strings 3/4" minimum / 1-2 strings / 14-6 AWG 3/4" minimum / 1-3 strings / / AWG Range ............................................................................................................................................... 1..4-.6 ...A...WG ................ Dimensions with Safety Switch 17.7x14.6x6.8 /450x370x174 21.3 x 14.6 x 7.3/540x370 in/mm n (HxWx 185 Weight with Safety ......................................tch 22 / 10 ....� . 25.../.........I_.__..._.._._...26 .. / 11:9.............. 38:8 / 17..._..:lb/ . kg Noise i <25 <50. dBA ............................... Coolln g.................................................... ..................... ..................... Natural Convection .... Natural convection ..................................... .... Operating Temperature Range .................. .13 to +140 / .25 to +60iai -40%F / -40°C option)i4I .... .... ..... .................................................................. °F / °C Protection Rating NEMA 3R (Inverter with Safe Switch) ..............ty........................................................... irl For other regional settings please contact SolarEdge support i'I Revenue grade inverter P/N: SEx)oaH-US000NNC2 (l) For power de -rating Information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (4) -40 version P/N: SExxxxH-US000NN1.14