HomeMy WebLinkAboutPROJECT DESCRIPTIONPROJECT DESCRIPTION:
17X(280W-295W) HYUNDAI (HIS-S280RG-HIS-S295RG)
MODULES
ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES
ARRAY AREA #1: 299.54 SQ FT.
EQUIPMENT SUMMARY
17 (280W-295W) HYUNDAI (HIS-S280RG-HIS-S295RG) MODULES
SHEETINDEX
A-00 PLOT PLAN & VICINITY MAP
S-01 ROOF PLAN & MODULES
8-02 STRUCTURAL ATTACHMENT DETAILS
DS-01- 03 DATA SHEET
RECEIVED
APR 13 2018
Permitting DepartM4111t
St. Lucie'CoudV
N
GOVERNING CODES:
FLORIDA ELECTRIC CODE, 6TH EDITION 2017 EDITION (FEC) $
FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 (FRC) w
FLORIDA PLUMBING CODE, 6TH EDITION 2017 (FPC) 5
FLORIDA BUILDING CODE, 6TH EDITION 2017 EDITION (FBC) '
FLORIDA MECHANICAL CODE, 6TH EDITION 2017 (FMC) s P
ARTICLE 690, NEC 2014 CODE BOOK '
SGANN99
� ,
240'-51' —
_- i
FILE- COPY
IN
1
242'-1"
�— ROOF #1
(17) (280W 295W) HYUNDAI
(HIS-S28ORG-HIS-S295RG) MODULES
W 15T 5T,
HOUSE PHOTO SCALE: NTS
2
pp 00
PROJECT SITE
Kr
1014
ppTE
DESCSjV,1
PRO
N�T`� Mp,P _ SCALE. NTS
p�0
LU
U
$ a
Ll
0
CD
SNE� 512E
NUMBER
SRE� O
A0
MODULE TYPE, DIMENSIONS &WEIGHT
NUMBER OF MODULES =17 MODULES
MODULE TYPE = (280W 295W) HYUNDAI
(HIS-S280RG-HIS-S295RG) MODULES
MODULE WEIGHT = 41.2 LBS 118.7 KG.
MODULE DIMENSIONS = 64.57" x 39.29" = 17.62 SF
UNIT WEIGHT OF ARRAY = 2.34 PSF
(E) BACK YARD
N
w a
s
GENERAL INSTALLATION PLAN NOTES:
1) DRAWINGS SHOWN MAY NOT REFLECT FIELD CONDITIONS.
CONTRACTOR TO FIELD VERIFY CONDITIONS PRIOR TO
INSTALLATION.
2) CONTRACTOR MAY LOCATE PV MODULES TO DIFFERENT
LOCATION THAN SHOWN, BUT SHALL NOT PLACE PV MODULES IN
WIND ZONE 3. UNLESS NOTED OTHERWISE IN NOTE 3 BELOW.
3) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED
AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND
ZONE:
WIND ZONE 1: 48" O.C.
WIND ZONE 2: 32" O.C.
WIND ZONE 3: 16" O.C.
SEE SHEET S-02 FOR SUPPORTING CALCULATIONS.
4) EXISTING RESIDENTIAL BUILDING IS ASSUMED TO BE METAL
ROOF WITH MEAN ROOF HEIGHT LESS THAN 30 FT AND SYP 2X4
WOOD ROOF TRUSSES SPACED 24" O.C. EXISTING ROOF SLOPE
FOR SOLAR SYSTEM RETROFIT IS ASSUMED TO BE BETWEEN 7
TO 27 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL eel
REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST ee
BETWEEN PLANS AND IN FIELD CONDITIONS.
1ti :
WIND ZONE 2 (TYP.)
WIND ZONE 1 (TYP.) 39.29
i'o
ti
Lo
4
co
_WIND ZONE 3 (TYP.)
HYUNDAI
(HIS-S280RG-HIS-S295RG)
MODULES
LEGEND
VIND ZONE 3 (TYP.)
JB
- JUNCTION BOX
INV
-INVERTER
Dc
- INTEGRATED DC DISCONNECT
ROOF #1.
TILT -18A
sLD
- SOLAR LOAD CENTER
AZIM. -180"
PM
- PRODUCTION METER
_
MSP
-MAIN SERVICE PANEL
O ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION)
I C O - ROOF ATTACHMENT
-RAFTERS
.HIS-S295RG) ----- - CONDUIT
CB - COMBINER BOX
CASTILLO ENGINEERING
SERVICES, LLC
COAK28345
2381 CREST RIDGE COURT
SANFORD, FL 32777
TEL 407.474-8751ERMOCRATES E.
CASTiuO. FL PE 52590
REVISIONS
DESCRIPTION
DATE
REV
PROJECT DEVELOPER
0 9-1018
etttoAPR
gBd
S(1L. _
0
Wm-Seald i
5
0
OF m
ea
F � .•�� eea
°
� �i��
ttttee
PROJECT NAME
U 00
Z 0)
It
Lu F— c
0 (1)
_j
F—
w TCo
oa
w
Z F-
O
m
SHEET NAME
ROOF PLAN &
MODULES
SHEET SIZE
ANSI 6
11" X 17"
SHEETNUMBER
S-01
NOTES: 13`
- 5/16" LAG BOLTS MUST EMBED 2.5" INTO ROOF STRUCTURAL
MEMBERS/RAFTERS l�e
- TORQUE ALL 5/16" HARDWARE TO THE FOLLOWING: Ise
-SILVER S.S. 10-16 FT-LBS
- BLACK S.S. 7-9 FT -BLS
- RAILS MOUNT TO DOWN SLOPE SIDE OF L FOOT
115
130
15e
v
�
.i
150
140
3/8-24 X .8" ROUND POINT SETSCREW
a
-_.-
totes:
150 -
1. Values are uNmate design 3-second cast
f
170
wind speeds in miles per hour (ads) at 13
ft (20a) above ground for Exposure C cat-
i}
egory.
MODULE 2. Linear interpolation between contours
160 _1 0d I�
MID CLAMP S-5-N BRACKET is p1mitted.
' 3. Islands and coastal areas outside the
an,
----•'�
:-
last contour shall use tde lest wind speed
170
contour of the coastal
4. Mountainous terrain, gorges, ocean
�_ .
wind regions
ies, and spefor
—•-
_ 180
'hall be unusual
e � shall be etadned for unnsaal wind condf-
--�
SNAP AND RAI
RI
EZ L FOOT CAN P'
MOUNTED IN AP
ORIENTATIC
3/8-24 X .8" ROUND POINT SETSCREW
1 ATTACHMENT DETAIL (ENLARGED VIEW)
S-02 SCALE:NTS
LOCK SEAM
AND 18" O/C
_ BOLT 3/8 -16x 3/4" RAIL
BOLT SUPPLIED BY
RAIL MANUFACTURER
S-5-N BRACKET
FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF
SURFACES WITH LOW TO MODERATE TILT.
RAILS CAN BE LEVELED UP TO 3" USING UP TO TWO LEVELING
SPACERS AS SHOWN IN "SERIES 100 RAIL LEVELING".
USE GEOCEL 3300 PROFESSIONAL GRADE POLYURETHANE SEALANT
OR APPROVED SIMILAR FOR WATER TIGHT SEAL AS REQUIRED
ti«r . t
5. Wind speeds correspond to approximtely ISO
a 7: probability of excellence in 50 years ( �,
(Annual Exceedance Probability a 0.00143,
NRI = 700 years). `
0
FIGURE 1609A ULTIMATE DESIGN WIND SPEEDS, VOLT, FOR RISK CATEGORY II BUILDINGS AO
OTHER STRUCTURES
Wind Speed Ult (mph)
60
Risk Category
11
Wind Speed ASD (mph)
0
Exposure Category
B
Mean Roof Height (ft)
15
Roof Slope (degrees)
0
Module Area (sq ft)
ZO
Kzt
1
Height Adjustment Factor, A
1
Roof Zone
Pnet (30)
1
16
-27
2
16
-44.6
3
16
-67
P_net=KAKI ztP_(net(30))
`Roof Zone
' Pnet
1
16
-27
2
16
-44.6
3
16
-67III
Roof Slope Calculator
Rise
Run
I Slope (e)
1r2
18.4
Maximum Uplift per
*fastener Wind Zone 1
2970
Allowable Up Load of S-
N Bracket per S-5 test
362
report
* Roof attachments at 48" O/C w 2 rails
Maximum Uplift per
*fastener Wind Zone 2
327.5
Allowable Up Load ofS-
N Bracket per S-5 test
362
report
* Roof attachments at 32" O/C w 2 rails
Maximum Uplift per
*fastener Wind Zone 3
245.1
Allowable Up Load of S
N Bracket perS-Stest
362
report
CASTILLO ENGINEERING
SERVICES, LLC
COA • 28345
2381 CREST RIDGE COURT
SANFORD,FL32771
TEL• 407-474.8181ERMOCRATES E.
CASTILLO- FL PE RE2
REVISIONS
DESCRIPTION
DATE
REV
PROJECT DEVELOPER
°°9 a 9 4,�Be:.
e s-(1LL0
O ign ..
re with Sea
•z::
P
F L •O %
ES •
fill yr
PR CT NAME
U 000
Z 0)
It
W M
a C7
LJL
55 i—
W Co U
Uj o
Uj a.
Z r H
Q 0
m
SHEET NAME
STRUCTURAL
ATTACHMENT
DETAILS
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
*Roof attachments at 16" O/C w 2 rai Is c—U2
HYUNDAI SOLAR MODULE
RGMulti -Crystalline Type
HiS-1142501313 HiS-M255RG
Mono -Crystalline Type
SERIES HIS-S275RG HiS-S280RG
HiS-S295RG HiS-S300RG
1
o--R
PERL Technology
PERL technology provides ultra -high
efficiency with better performance in low
irradiation. Maximizes installation capacity
in limited space.
Reliable Warranty_
11YUNDAi
Global brand with powerful financial
strength provide reliable 25-year
warranty.
Hyundai's Warranty Provisions
10
• 10-Year Product Warranty
vEARs
• On materials and workmanship
25
• 25-Year Performance Warranty
YEARS
Initial year: 97%
Linear warranty after second year:
with 0.7% annual degradation,
80.2% is guaranteed up to 25 years
Certification
BYE C �L BS (1 'VIZ.
C E 11STEII \11.11.,
www.hhigreen.com
HiS-M260RG HiS-M265RG
HiS-S285RG HiS-S290RG
MADE IN
KOREA
♦Ii
Low LID / PID
Both LID(Light Induced Degradation) and
PID(PotentialInduced Degradation) are
strictly eliminated to ensure higher actual
yield during lifetime.
NH,
Natl
. - - - - - Corrosion Resistant
Various tests under harsh environmental
conditions such as ammonia and salt -mist
passed.
About Hyundai Solar
1
5.
t t t Mechanical Strength
Tempered glass and reinforced frame
design withstand rigorous weather
conditions such as heavy snow and strong
wind.
00--al'
VDE Test Labs
Hyundai s R&D center is an accredited test
laboratory of both UL and VDE.
Established in 1972. Hyundai Heavy Industries (HHI) is one of the most trusted names in the heavy
industries sector with 48,000 employees and more than 40 Billion USD in annual sales (2015). As
a global leader and innovator, Hyundai Heavy Industries is committed to building a future growth
engine by developing and investing heavily in the field of renewable energy.
Started as a core business division of HHI, Hyundai Solar (Hyundai Heavy Industries Green Energy)
now stands as an independent company and an affiliate of HHI as from December 2016. It is the
largest and the longest standing PV cell and module manufacturer in South Korea with 800 MW of
module production capacity. We have strong pride in providing high -quality solar PV products to
more than 3,000 customers worldwide.
A HYUNDAI
GREEN ENERGY
Printed Date : 0512017
Electrical Characteristics
250 255
37.4 37.6
I i 8.7 8.8
r' 30.9 31.0
---
260
371 -
8.9
31.1
265
37.9
9.1
31.3
275 ----
38A
9.3
280
38.5
9.4
�285f
38.7
9.5
-
290
3B.8
9.7
~ 295 -
39.0
9.8
300
39.1
9.9
31.6 31.7 31.8 32.0 _ - 32.1 -
-32.3
;?
1 8.1
8.2
8.4
8.5
8.7
8.8
8.9
9.1
9.2
9.3
i=s
j 15.3
15.6
15.9
16.2
16.8
17.1
17.4
17.7
18.0
18.3
!i
6", multi -crystalline silicon
6", mono -crystalline
silicon
1,000
1,000
-0.41
_
-0.40
-0.31
_.
-0.29
-
- -
0.0'39
0.039
Mechanical Characteristics
t 998 mm (39.29')(W) x 1,640 mm (64.57)(L) x 35 mm (1.38')(H)
Weight Approx.18.7kg (41.2 Ibs)
Solar Cells60 cells in series (6 x10 matrix) (Hyundai cell, Made in Korea)
1utputGables 4 MM2 (12AWG) cables with polarized weatherproof connectors,
IEC certified (UL listed), Length 1.0 in (39.4')
I168, weatherproof, IEC certified (UL listed)
Bypass Diodes 3 bypass diodes to prevent power decrease by partial shade
Construction Front: Ant -reflection coated glass, 3.2 mm (0.126")
Encapsulant: EVA I Back Sheet: Weatherproof film
Frame Clear anodized aluminum alloy type 6063
'A9 data at STC (Standard Test Conditions). Above data may be changed without prier notice.
Installation Safety Guide
• Only qualified personnel should install or
perform maintenance.
• Be aware of dangerous high DC voltage.
• Do not damage or scratch the rear surface
of the module.
• Do not handle or install modules when they
are wet.
Nominal Operating
46°C t 2
Cell Temperature
Operating Temperature
-40 - 85°C
Maximum System Voltage
DC 1,000 V (IEC)
DC 1,000 V (UL)_
Maximum Reverse Current
15 A
Module Diagram (unit:mm)
I-V Curves
Mono -Crystalline
Multi-Cryslalline
Current[A]
Si Type -Front Side View
Si Type -Front Side View
10
I• 9Wdlpil "1ri1p16
r
2=nNe
-- �1
5
I I
I: RcaEs
+
s
Ii
1
I Ao3-
Hl xIXE
4 b.- hod = l.000wle
3 - Opening fe0 Tom. 5 C
I
CY.Mo1
GatE"�
0@dff w
2-Owatrq re0 Temp-25C
3
,•I,o
Opammg CeOTemp= 45 C
opomum UOTemp= as
Il
coum OAPo(
0 0 10 20 30 40 50
T . a2
GFVDNO�
1
IVI
�uEs
Current [A]
Itan
i
(Ro"
HRE�i �
� -hrA hasvl.�d4y/m' cataTo
=
4-mdd.vral=somwm�
a.m
s Storm'
r-
i��
... ,
}. -,
i
is
3
Z-hma.ead=20MW
j�--
30
n
5)5 ®
00 5 10 15 20 25 30 35 10 45 50
DETAIL DETAILB
SECTION CC
SECTION D-D DETAILE
wWivi
Sales & Marketing
�tzmwn��d 55. Bundang-ro. Bundang-gu, Seongnam-si. Gyeonggi-do, 13591. Korea
FsC Tel: +82-31-8006-6910.6930, 6906 1 Fax: +82-2-746-7675
AHYUNDAI
GREEN ENERGY
Printed Date. 05/2017
1
L
CASTILLO ENGINEERING
SERVICES, LLC
COA428345
2381 CREST RIDGE COURT
SANFORD, FL 32771
TER• 407474-9181ERMOCRATES E.
CASTILLO - FL PE 52590
REVISIONS
DESCRIPTION
DATE
REV
PROJECT DEVELOPER
APR 0 9 2018
t,eeeeeee6s�-
1LLO
S ES n✓ttw vvi0t S �®
•�
g0 0
. � o
s
O :ZO
Ui o
0
e
♦
04
U 000
Z
W M
(j)
H LL
LV U
W O p•
O
m
SHEET NAME
DATA SHEET
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-01
The SnapNrack line of solar mounting
systems is designed to reduce total
installation costs. The system features
technical innovations proven on more
than 10OMW of solar projects to simplify
installation and reduce costs.
Pitched Roof Arrays Simplified
The SnapNrack Series 100 Roof Mount System is an
efficient, visually appealing, photovoltaic (PV) module
installation system. Series 100 was developed in the
field by a team of veteran solar engineers and installers.
Their goal was to ensure a quick, efficient installation.
Series 100 has been tested on megawatts of real -world
residential and commercial installations. Industry
leading installation times are achieved with unique
Snap -in fasteners and fully adjustable components that
make installation of roof mounted solar arrays easy
while achieving lower installation costs.
• Up to 3" of height adjustability at roof connection
• Waterproof full -metal flashing at each roof penetration
• Works on virtually all composition and tile roofs
• Single wrench size for all system hardware
• Configures easily as low profile or tilt (0-60 Degrees)
• Rail channels provide excellent wire management
Patent Pending
Roof System in. 4 Simple Steps:
1) Identify Site Conditions (Array Tilt, Building
Height, Roof Type, Wind and Snow Loads)
2) Determine Footing Spari from Engineering
Tables (download at www.snapnrack.com)
3) Choose color (Clear or Black) and roof
attachment type
4) Place Order with your distributor. Purchase
material fora single project or order in bulk
for additional savings
Rail & Module Clamps
Roof Attachments
- Array Accessories
SnapNrack-
PV Mounting Systems
on the rail
• Rail channels provide improved wire management
• Vertical and horizontal adjustments ensure superior fit
Innovative Universal End Clamps
SnapNrack•• Technical Data Patent Pending
Materials
• 6000 Series aluminum
• Stainless steel
• Galvanized steel
Material Finish
-Clear and black anodized aluminum
Installation
• (wick and efficient mounting
-Adjustable hardware to ensure clean and level finish
• Worry -free waterproof flashing
Calcs. & Certifications
• Wind speeds up to 150 MPH and snow loads to 120 PSF
Grounding
• Washer, Electrical Equipment Bond (WEEB) or lay -In lugs
Warranty
• 10 Year material and worksmanship (download full details at snapnrack.com)
SnapNrack-
PV Mounting Systems
(877) 732-2860 www.SnapNrack.com
O Printed on recycled paper using soy based inks.
W 2012 by SnapNrack PV Mounting System, All rights reserved.
CASTILLO ENGINEERING
SERVICES, LLC
COA 0 28345
2381 CREST RIDGE COURT
SANFORD,FL32771
TEL: 407-474.9181ERMOCRATES E.
CASTILLO - FL PE 52590
REVISIONS
DESCRIPTION DATE REV
PROJECT DEVELOPER
APR 0 9 '.1010
`�474tGA0y;,;
C)lILLO J°"�e-
a•,a
gpature al �.
0 r
d®
O •L T
•z@
L • �� �0s
U 00
Z a)
W M
(n J
(0
ILL
in
W rU
U) O W
W M a
Z
m LL
SHEET NAME
DATA SHEET
SHEET SIZE
ANSI B
11" X 17"
SHEET NUMBER
DS-02
The S-S-N and S-S-N Mini clamps are each furnished
with the hardware shown to the right. Each box also
includes a bit tip for tightening setscrews using an electric
screw gun. A structural aluminum attachment clamp, the
S-5-N is compatible with most common metal roofing
materials excluding copper. All included hardware is
300 series stainless steel. Please visit www.S-5.com for
more information including CAD details, metallurgical
compatibilities, and specifications.
The S-5-N clamp has been tested for load -to -failure results
on most major brands of 1" nail strip profiles of standing
seam roofing.The independent lab test data found at
www.S-5.com can be used for load -critical designs and
applications. S-5!e holding strength is unmatched in the
industry.
Example Profiles
S-511 Warning! Please use this product responsibly)
Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for
complete information on patents and trademarks. For maximum holding strength, setscrews should
be tens
loned and re -tensioned as the seam material compresses. Clamp setscrew tension should be
verified using a calibrated torque wrench between 160 and 1801nch pounds when used on 22ga steel,
and between 130 and 1501nch pounds for all other metals and thin nergauges ofsteel. Consult the S-5!
website at www.S-S.com for published data regarding holding strength.
Copyright2013, Metal Itoof Innovations, Ltd.S-51 products are patent protected.
S-5! aggressively pmtectsitspatents, trademarks,ardcopyrights. Version072213.
N C is r ri
Vilollparts
wo M10 holes located
/2" (13mm) from edge
2.00" r
(51.00 mm)
0.49"
(12.00 mm)
1.69"
(43.00 mm) D -�
1.09i, I 0.71"
(28.00 m 1.02" (18.00 mm)
(26.00 m )
D i
0.56" a- 2 setscrews
(14.00 mm)
1.57" '-_
-- ----- (40.00 mm) ---- -- -- --
Sa5-N Mini Cllannp
-� M8hole _centered
on part
1.18"
(30.00 m I
t _ 0.49"
(12.00 mm)
1ss"
1.09" 1.02" (18.00 mm)
(28.00 m (26.00 m ),
1 �-
1 Setscrew
0.56"
(14.00 mm)
1.57" r
(40.00 mm)
Please note: All measurements
are rounded to the second decimal place.
Distributed by
art
CASTILLO ENGINEERING
SERVICES, LLC
COA 028345
2381 CREST RIDGE COURT
SANFORD, FL 32771
TEL•407-4748181ERMOCRATES I-
CASTILLO - FL PE 52580
REVISIONS
DESCRIPTION
DATE
REV
PROJECT DEVELOPER
APR 0 9. 201k
®```�t19iYt9SJ6:e�
ao
G ign with Seal
5 W
• LIJ
:2
F �. � eeb
to 51
PROJECT NAME
U N ao
Z a'
W cY)
/� LL
VJ
W >� U
Ill n-
NZ
N..
O
m LL
SHEET NAME
DATA SHEET
SHEET SIZE
ANSI B
11tt X 17"
SHEET NUMBER
DS-03