Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL SHUTTERSFlorida Building Code Online https://www.floridabuildin&orgfpr/pr app dtl.aspx?param=wGEVX... V .�I��.�.�,,,�,�S,�r,� urmwsati �t C .^. � ✓ &..�.�1�'S,F�-� 3rAY� 69'�'R„rr 4 �ta sy44 �S i t'j ,"y,-,i,� �'a �t�c' ♦ y: :a„ s.. �:,.k..,� -'�. �.w�....�z.�;£'�'T?.r.....�v. �i a..:��a..i.,.�....+.. ,-�c�,ni,�.m �l`9♦ ",1�� Y J Y ,x, �Yµ N �, �'S 'S t� Z �§eF9..cZTT n�tif(Aa iS J•YWA.k.-+Qrr�^a'�M 4ADKI: BCLSHome log In User Registration Hot Topics Submit Sunitarge Stats&Faits gPublications av BM Sle Map links Search dbapr a ProdutL ApprovalUSER: Pubrc user Bpquct Bporaval Meny > Product or Awtkatlm Sgprch. Aoogcadon fla> Appgmtlon Det" Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Emall Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By i i FL11968-R4 Revision 2017 Approved Eastern Metal Supply 4268 Westroads Drive West Palm Beach, FL 33407 (800)432-2204 ]rodriguez@easternmetal.com BIII Feeley Irodriguez@easternmetal.com Shutters Storm Panels RECEIVED APR 13 2018 T. Lucie County, Permitting FILE-.COP,Y- Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Walter A. Tlllit, Jr. PE-44167 National Accreditation and Management Institute 12/31/2018 John Henry Kampmann Jr. Validation Checidist - Hardeopy Received Certificate of Independence fl-11968 R4 COI EgS_rERN METAL SUPPLY, INC.- DRAWING 17-098CERTIFICATION OF INDEPE QENCE_PQE LSF 1968. R4 tr I EASTERN METAL SUPPLY. IN�DRAWING 17_pR gP_ CATION OF INDEEENQENtiE.PDE 19¢ R4 COl EASTERN_ME7AL SUppiy, INC pRAWING�j=09¢ CE�.7T CAjWU- FF Th DEPENDENCE PDF FL11968 R4 COI EASTERN M LTAL SUPPLY2�c ZyC_BAWING 17-034 CEE IE�AZTON OF ?LERNPFP&-j :R4f Referenced Standard and Year (of Standard) Wandard V— ASiM E330 2002 SSTD12-99 1999 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect �L468 RA Epuiv EASTERN MCI SUPPLY,IMC_DRAyy(NG 17-QQ$ LETTER EQUIVALENCE BEZWEEN $3L� 12-99_ANASTM E-19�6.PDF E-Ll)968 R4 Eculy EASTERN META_ UPPLY. INC_DRAWING��j�$_{ ETTER OF EQUI 7�p�ENCE SrD 12-9�ND ASTM E:U-25_WF FL11968 R4 Efy ASTERN METALS, PPLiIbLC DRgWIVG )7-096 LE77ER E�lIVVALENCE BETWEEN SSTD 1,� AND A _ E-1996.PDF E_L11968 R4 Eouiv EA9rERN METAL SUPFL INC, OgAVL 12::094 LETTER EOUIVALE�IT BETWEEN S5-D 1 2-99 AND -1996.odf I of 3 4/312018, 5:06 PM Florida Buiidmg (:one untine Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/20/2017 Date Validated 10/28/2017 Date Pending FBC Approval 10/29/2017 Date Approved 12/12/2017 Summary of Products -Descriptitm — FL # Model, Number or Name 11968.1 0.040" Bertha Aluminum Storm Panel (2.25" Corrugated aluminum storm panels retained or not by tracks provide Deep)- Non-HVHZ - Drawing Number 17-094 hurricane protection. Llmlffi of Use Ifnstatfation Irtsbvxu as i Approved for use in HVHZ: No g 1968 R4 IIi ASTERN METAL SUPPLY2c INC. DRAWING 17-094 0.040 Approved for use outside HVHZ: Yes B�RSi11iLt}p1liSU�Q ft�ALAWEL pelf Impact Resistant: Yes Verified By: American Test Lab of South Florida Inc Design Pressure: N/A Created by Independent Third Party: Yes Other: Large Missile. Max. span is 12'-0" for +25, -25 p.s.f. and 4'-0" for +125, . Evaluation Reports 130 p.s.f. for sections 1, 3, 4, 6, 7, 8, 8A, 9 and 31. See sheet 10 of installation EU�6ER4 AE EASTERN M�TA_ffl1YZc IN DRAVYIfSG 14 PRODUCT drawing for other spans and pressures. Valid only for wind zones 1,2 & 3 as EV_LLLUAT10N REP08RT pd_f defined by ASTM E 1996. Created by independent Third Party. Tres 11968.2 0.050" Bertha Aluminum Storm Panel (2.25- Corrugated aluminum storm panels retained or plat by tracks to provide Corrugated Deep)- Non-HVHZ - Drawing Number 17-096 hurricane protection. Limits of Use Installation Instructions FL11968 R4 11sEASi E$N M AL S PPLYyI dI�C_Dg�Y7i�LG 17- 96 0.050 Approved for use in HVHZ- No Approved for use outside HVHZ: Yes _ BEM A AL_UNUM STORN ANEL PDF Veriru�d Hy: American Test Lab of South Florida Inc - Impact Resistant: Yes Design Pressure: N/A Created by Independent Third Party: Yes Other: Large Missile. Max. span is IT-11" for +30, -30 p.s.f. and W-2" for+75, -80 p.s.f. for mountings without "h" header. See sheet 5 of installation drawing Evaluation Reports FLi1968 R4 _E EASTERN METAh $ PPLY• INC• DRAWL 17-096 PRODUG[ for other spans and pressures. Valid only for wind zones 1,2 & 3 as defined by OF EVALGATI _N REP�RT.PDF ASTM E 1946. Created by independent Third Party: Yes _....._ _ .....i 11968.3 24 Gage Galvanized Bertha Steel Storm Panel corrugated gatvanizr_d steel storm panels retained or not bytracks to provide (2.25" Deep)- Non-HVHZ - Drawing Number hurricane piritection. 17-095 Limits of Use Approved for use In HVHZ: No Ynstaffation Instructions FL 1 68 R4 II EASTERN�tDtAl SILPLY INC O$AWINEI7-Q95�4 Gil GE —E Approved for use outside HVHZ: Yes GVgr9 BE TH�k S7EFL S70RM PANE_L_PRF Verified By: American Test Lab of South Florida Irm Impact Resistant: Yes Design Pressure: N/A Created by Independent Third Party: Yes Other: Large Missile. Max. span is W-B" for +30, -40 p s.f. and 7`-2" for +70, 80 p.s.f. far panels mounted without "H" header. See sheet 4 of inSYdttatiorr Evaluation Reports F1968 R4 AE EASTERid h7ETAt SUP�LY,NC. DRAwtiDiG 17 =og5 PRODUf�T Edrawing for other spans and pressures.Vaiid only for wind zones 1,2 & 3 as . EVAyQ?IQi�_REPQRT.PgF i defined by ASTM E-1996. --......._........._...__......_ .....__._......._.. __..._..... _._.._...-..._.__ . Created by Independent Third Party: Yes _ ...:_...._..._ - s 11968.4 (]ear Bertha Storm Panels (21/4") - Drawingcorrugated polycarbonate storm panels retatned or rtbt by trams bD provide ' j Number 17-098 hurricane protection. Limits of Use n instructions Filii 6$ R4 I A A M AL StZPpJry, I C_I) 1LV3NC 17-098 C1=EAR Approved for use in HVHZ: No Approved for use outside HVHZ: Yes ¢_EPjHA_MRL4 PANEL 2.2&EDF Impact Resistant: Yes Verified By: American Test Lab of South Florida Inc Design Pressure: N/A Created by Independent Third Party: Yes Other: Large Missile. Max/ span is W-W for +28, -28 P.s.L A.S.D. and 4-0" for Evaluation Reports 1 -110 A.S.D de5gin load. See sheet 3 of instaoatian drawings for , FL13�68 R4 AE EA515BA11LUAL.SUPPLY. INC. DRAN7NG 17_098 P_ (f Dj1.�T +105, p.s.f. R4 �E other spans and pressures. Valid only for wind zones 1,2 & 3 as defined by ASVALUAj QN $EROR i PDE E-1996. Created by Independent Third Party: Yes �i Can=t35:: 26fl! �a5lorm Road 'f)rase t332399 9 Jasau!: 850-087-1824 ,fhe State of Fbiftla Is an;WEW emflayer Qmff R07-2013 State orFfdrida.:: RP mStatemea::AncessiM Statement:: WindStarancaR Under Fbdda law, emar addresses are Fd& remrds. If you do not wart youre-ns39 address neeased bi kespartse to a lid* -rends request. do Mt send efeamrrc na3ta ldis caddy. bZtead, mniact the of&e by Phone or by tradmnal rnal 9 you have any queswns, piamecontact$50.487.1395."PmSvant to Seccbbn455.275t1), HUMB StatrteS, effedWe Ociahe' 1. 2012, LO MMS ftWW40111W r-talpter455, FS. must pmwW_ do DeparftT nt wth an einai address FOW kwe aim The emaffi p+ovned niay ba used foraf&61 mntm:aelmMrtvdth the Ftt nw& Uaraever ema9 address are palftm=& 179aa do not wish to supply a p—nal addnm, Rye pmvdetheDepeflyiumgnab an enigad*m alfth glee tta&earaUb2q to co pADL To datervike 6you we a Wasee urtderfh.'pta4ss FS, Amse Ckk preys. PreductlippanizIAUMOtm 2 of 3 4/312018, 5:06 PA 1. STORM PANEL SHOWN ON THIS PRODUCT EVALUA77ON DOCUMENT (P.E.D.) HAS BEEN VERIFIED FOR COMPLIANCE 1N ACCORDANCE WITH THE 2017 (6th EDITION) OF THE FLORIDA BUILDING CODE. THIS STORM PANEL SYSTEM SHALL NOT BE INSTALLED AT HIGH VELOCITY HURRICANE ZONES (M/AMI—DADS / BROWARD COUN7Y). DESIGN WIND LOADS SHALL BE _DETERMINED AS PER SECTION 1609 OF THE ABOVE MEN77ONED CODE, FOR A WIND SPEED AS REQUIRED BY THE JURISDICTION WHERE THESE SHUTTERS WILL BE INSTALLED. AND FOR A DIRECTIONALITY FACTOR Kd=0.85 USING ASCE 7-10 FOR INSTALLATIONS UNDER 2017 FBC AND SHALL NOT EXCEED THE MAXIMUM (A.S D.) DESIGN PRESSURE .RATINGS INDICATED ON SHEETS 4 & 5. IN ORDER TO VERIFY THE ABOVE CONDITION, ULT7M4TE DESIGN WIND LOADS DETERMINED PER ASCE 7-10 SHALL BE FIRST REDUCED TO A.S.D. DESIGN WIND LOADS BY MULTIPLYING THEM BY 0.6 IN ORDER TO TO COMPARE THESE W/ MAX. (A.S.D) DESIGN PRESSURE RATINGS INDICATED ON SHEETS 4 & 5. STORM PANELS ADEQUACY FOR IMPACT AND WIND RESISTANCE HAS BEEN VERIFIED IN ACCORDANCE W7H SECTION 16D9.1.2 OF THE ABOVE MEN77ONED CODE AS PER ATL REPORT. #0130.01-01 AND 0703.01-07, PER IMPACT 7ES77NG EQUIVALENT To ASTM E-1996 STANDARD & ASTM E 330-02. STANDARD, UM/TED TO INSTALLATIONS WITHIN WIND ZONES 1, 2 & 3 AS DEFINED BY ASTM E-1996 STANDARD. 2. CLEAR BERTHA STORM PANEL SHALL BE EXTRUDED USING ANY OF THE FOLLOWING POLYCARBONATE SOURCES WITH THEIR CORRESPONDING MODEL NUMBER. GENERAL ELECTRIC PLASTICS LEXAN 103 DOWN CHEMICAL CAUBRE 302 V-5 CAVESTRO, LLC. MAKROLON POLYCARSONATE SHEETS MINIMUM PROPERTIES FOR ALL OF THE A60VE POLYCARBONATES ARE AS FOLLOWS. TYPICAL PROPERTIES APPLICABLE STANDARD REFERENCE RESULT PHYSICAL: SPECIFIC GRAVITY ASTM 0792 1.20 G/CC MECHANICAL:. TENSILE YIELD STRENGTH ASTM D638 8,700 p.s.i. FLEXURAL STRENGTH AT YIELD ASTM D790 12,500 p.sJ. FLEXURAL MODULUS ASTM D790 340,000 p.s.i. IMPACT NOTCHED IZOD ASTM 0256 18 FT-617n FIRE BURNING CHARACTERISTICS: SMOKE DENSITY ASTM D2843 75 (MAX) RATE OF BURNING ASTM D635 C-1 CLASS (MAX) SELF IGNITION ASTM 01929 650 'F J. ALL ALUMINUM EXTRUSIONS SHALL BE ALUMINUM ASSOCIA77ON 6063—T6 ALLOY & TEMPER. 4. ALL SCREWS TO BE STAINLESS STEEL 304 OR 316 AISI SERIES OR .CORROSION RESISTANT COATED CARBON STEEL AS PER DIN 50018 W/ 50 KS! YIELD STRENGTH AND 90 KSl TENSILE STRENGTH & SHALL COMPLY W/ FLORIDA BUILDING CODE SECTION 2411.3.3.4. 5. BOLTS TO BE ASTM A 307, GALVANIZED OR AISI 304 SERIES STAINLESS STEEL, WITH 36 KSI MIN. YIELD STRENGTH. 6. ANCHORS TO, WALL SHALL BE AS FOLLOWS.' SEE SHEET 2 OF 5 FOR APPLICATIONS (A) TO EXISTING POURED CONCRETE. MIN. F'C — 3 KSI --1/4" 0. TAPCON ANCHORS MANUFACTURED BY L.T.W. BUILDEX —114" 0 X 7/8- CALK —IN ANCHORS OR ELCO MALE & FEMALE PANELMATE" MANUFACTURED BY POWERS FASTENERS INC AND ELCO CONSTRUCTION PRODUCTS RESPECTIVELY. —1/4" 0 X 3/4" ALL POINTS _SOLID —SET ANCHORS AS DISTRIBUTED BY ALL POINTS SCREW, BOLT & SPECIALTY COMPANY. F-IL RECEIVEc NOTES: 1NI M T I POURED CONCRETE OF TAPCON ANCHORS IS 1 3/4- AND .FOR ELCO PANEUVATES IS 1 3/4- C 7 " AND 3/4' SOLID SET ANCHORS SHALL BE ENTIRELY EMBEDDED INTO THE POURED CONCRETE. EM I STUCCO SHALL BE PERMITTED. 1 2 CREW USED SHAH BE 1 1/2" LONG MINIMUM SHOULD STUCCO EXIST, AND 1 " MINIMUM FOR WALLS WITH NO STUCCO. A.3) IN CASE THAT PRECAST STONE PRECAST CONCRETE .PANELS, OR PAVERS BE FOUND ON THE EXISTING WALL OR FLOOR, ANCHORS SHALL BE LONG ENOUGH TO REACH THE MAIN STRUCTURE BEHIND SUCH PANELS, ANCHORAGE SHALL BE AS 7NDICATED ON NOTES A. 1) & A.2) ABOVE. (8) TO EXISTING CONCRETE BLOCK WALL: ASTM C-90 —114" 0 TAPCON ANCHORS MANUFACTURED BY LT.W. BUILDEX. —1/4" 0 X 7/8" CALK-/N ANCHORS OR ELCO MALE & FEMALE PANELMATE" MANUFACTURED BY POWER FASTENERS /NC. AND ELCO CONSTRUCTION' PRODUCTS, RESPECTIVELY —1/4' 0 X 3/4" ALL POINTS SOLID —SET ANCHORS AS DISTRIBUTED BY ALL POINTS SCREW, BOLT & 'SPECIALTY COMPANY. NOTES. B.1) MINIMUM EMBEDMENT OF TAPCON ANCHORS AND ELCO PAIVELMATES INTO THE CONCRETE BLOCK UNIT SHALL BE 1 1/4" 8.2) 7/8" CALK —IN ANCHORS AND 3/4" SOLID SET ANCHORS SHALL BE ENTERILY EMBEDDED INTO THE CONCRETE BLOCK UNIT. NO EMBEDMENT INTO STUCCO SHALL BE PERMITTED. 1/4" 0-20 SCREWS USED SHALL BE 1 1/2' LONG MINIMUM SHOULD STUCCO EXIST, AND 1 " MINIMUM FOR WALLS WITH NO STUCCO. B.3) IN CASE THAT PRECAST STONE OR PRECAST CONCRETE PANELS BE FOUND ON THE EXIS77NG WALL, ANCHORS SHALL BE LONG ENOUGH TO REACH THE MAIN STRUCTURE BEHIND SUCH PANELS ANCHORAGE SHALL BE AS INDICATED ON NOTES IN 8. 1) & B.2) ABOVE. (C) ANCHORS SHALL BE INSTALLED FOLLOWING ALL OF THE RECOMMENDATIONS AND SPECIFICATIONS OF THE ANCHORS MANUFACTURER. Z PANEL MAY ALSO BE INSTALLED HORIZONTALLY FOLLOWING INSTALLATION DETAILS SHOWN ON SECTIONS 1 THRU 5, SHEET 3 OF 5 8. STORM PANEL SHALL BE REMOVED AFTER THE HURRICANE AND SHALL BE STORED AND PROPERLY MAINTAINED. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE INHERE SHUTTER IS TO BE ATTACHED .TO INSURE PROPER ANCHORAGE 10. SHUTTER MANUFACTURER'S LABEL SHALL BE LOCATED ON A READILY VISIBLE LOCATION AT STORM PANEL SHUTTER • IN ACCORDANCE WITH SEC77ON 1709.9.3 OF F40RIDA BUILDING CODE. ONE LABEL SHALL BE PLACED FOR EVERY OPENING. LABELING TO COMPLY WITH SEC77ON 1709.9.2 OF THE FLORIDA BUILDING CODE 11. THE INSTALLATION CONTRACTOR IS TO SEAL/CAULK ALL SHUTTER COMPONENT EDGES WHICH REMAIN. IN CONTINUOUS CONTACT WITH THE BUILDING TO PREVENT WIND/RAIN INTRUSION_ CAULK AND SEAL SHUTTER TRACKS ALL AROUND FULL LENGTH 12. STORM PANEL INSTALLATION SHALL COMPLY WITH SPECS INDICATED IN THIS DRAWING PLUS ANY BUILDING AND ZONING REGULATIONS PROVIDED BY THE JURISDICTION INHERE PERMIT IS APPLIED T0. 13 (A) THIS P.F_D. PREPARED BY THIS ENGINEER 15 GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT- I.E. WHERE THE SITE CONDMONS DEVIATE FROM THE P.E.D. (B) CONTRACTOR TO 8E RESPONSIBLE FOR- THE SELECTION, PURCHASE AND INSTALLATION INCLUDING LIFE SAFETY OF THIS PRODUCT, BASED -ON THIS P.E.D. PROVIDED HE/SHE DOES NOT DEVIATE FROM THE CONDITIONS DETAILED ON THIS DOCUMENT CONSTRUCTION SAFETY AT SITE IS THE CONTRACTOR'S RESPONSIBILITY (C) THIS P.E.D. WILL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS- (D) SITE SPECIFIC PROJECTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER OR ARCHITECT WHICH WILL BECOME THE ENGINEER OF RECORD (EO.R.) FOR THE PROJECT AND WHO WILL BE RESPONSIBLE FOR THE PROPER USE OF THE P.E.D. ENGINEER OF RECORD, AC77NG AS A DELEGATED ENGINEER TO THE P.E.D. ENGINEER, SHALL SUBMIT TO THIS LATTER THE SITE SPECIFIC DRAWINGS FOR REVIEW. (E) THIS P.E.D. SHALL BEAR .7H.E DATE AND ORIGINAL SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER OF RECORD THAT PREPARED IT. THIS DRAWING SHALL ONLY BE USED TO OBTAIN PERMITS .IN THE' STATE OF FLORIDA •. ta. i •���j�7�o it w Yw~'• �. �14 ?• " FLORIDA BUILDING CODE ( Non High Velocity Hurricane Zone. -��Z �4• �'� * ,017 rrLrfco, INC.CLEAR BERTHA STORM PANEL ORAPIN BY 2.25" DEEP Lc. ••• 07126117 ?A61,1 ••''� ��., C ii N c . EASTERN METAL SUPPLY, INC DATE t' ••••••+•* 4268 WrSr ROADS DRNE SONG & ENGINEERING COMPANY WEST FAu} BEACH. FL .JJ407 17—Q98 5 !s �BVNA wa. St. S4-vKRWM wma% }7. -vlw yA!� MSP71-15W. Far: (30SP79-Tsai ORA WING No &9-0006719 Ary ft wr WALTER- A. 7/LUT Jr. RE r ow rs-M svlf Y FLORIDA Lic. ,$ 44167 1 s any t 1-1 SHEET i OF 5 APR 13 2018 ST. Lucie (;QQn` y� Permitting 15.120" r— 12.000' 500'� P'Fl=M500" (67) a As APPtrc�aE lrra�) —� 125" T CLEAR PANEL, t Max. ,j" ANGLE BUILD OUT BRACKET m i A+vErEO W AWLE b a 0 12' os, O .t ME tN( N DUNL ! ! i (MAX) 07 2 X57WX,,)X_,_t/8, ANGLE WITH STUD 9.120' 6.000' 00' 4.50.0"—r-1.500" AS AAFLr A%E AW f 10: TOLERANCE ; / \0. f00' t 10% TOLERANCE � F 2.125' f 3.875"----J HALF CLEAR PANEL t DOUBLE WE CLEAN? PANEL 3 " B O. "F" TRACK 4) "F" TRACK ANGLE ! - Jw- -m" 0 KEY HOLE WASHER 31OS-HlSd NUM AtLDY 3L70- R, �Op. .095• N � . LEG CDCATlDN _REVERSED "F" ANGLE RACK } COACRETE ANCHORS (SIZ SCH£DOCE) g'-{( I Orr 'WN�ib, t i if i-J, - —CONCRETE AIdOMS (SEE SCHEDULE) ! 36-1 Ara. UWA ! frn f Af lEa. STORM PANEL TYPICAL ELEVATION N.T.S. i/a` uox. cnn tla' Max.Gav h1Ew ro mai n L � 'm .fi32' 0 NJIN/ WALL 1.75 x0.632" ANGLE WIN STAID d NEN 053' Iy .a9a' f i ( .093" J a VARIES DETAIL 1: sw w/ a:E cisr me AWKEL PLATO wLYG Mo 3 8 I&RIDA BUILDING CODE ( Non High Velocity Hurricane ITMIBUILDEX TAPCONS, POWERS FASTENING CALK --INS OR £LCO TEXTRON PANELMATE -� (SEE SCHEDULE FOR SPACING). POURED CONCRE D. ETE REQUIRED 7' Min. - 5E7�ARATION 70 EXISTING GLASS 1/40-20 x 1' S. W/0000 7/8x 3/ WING UT 1 O.c POURS CONCRETE E D. OR CONCRETE BLOCK WALL REQUIRED "T (SEE SCHEDULE FOR SPACINQ -I SECTION 1 CALK -INS OR ELCO TEXINON Cont. NUT 0 SERYY3�D ® PANELMATE ®� W/ 1 4 0-20 1--NUT 12' O. C. STAGGERED SIDES'IALK BOLT 01 6� S ► I TO ANCHORS W/ 1/4 C 20TRUSSNEAD BOLT (SEE SCHEDULE FOR SPACING). s' i Max. PANEL LENGTH { (SEE SCHEDULE) ITW/BUILVEX TAPCONS OR POWERS FASTENING CALK -INS j (SEE SCHEDULE FOR SPACING). , f- 1"-4 ContQS --- 1/4"0-20 .x I" S. M, S. W/ 7/8' x 3/32' WING NUT ® 12" o.c.- 7 " MINIMUM SEPARATION TO EXISTING GLASS 1/41020 x t' S. S M. S W/ 7/8' x 3/32'.• .WING NUT 9 72' ox. LEG POURED E D. CONCRETE REQUIRED ` xl\. \ OR CONCRETE— 1 BLOCK WALL E. V. REQUIRED I I1iY/BUILDEX TAPCONS, POWERS FASTENING CALK--MOR £LCO TE E SC PDULE FOR (SEE SCHEDULE FOR 1 SPACING). + (� n u ��d CON RE4 Mat. PANEL UNGM (SEE SCHEDULE) OR CONCREiL g BLOCK WALL REQUIRED "� f l', BUILDEX TAPCONS f oCAfX-lNS OR ELCO TFXTRON � / t\ PANEZMATE ® W/ �4 0-20 / POD S FASTENING ,N SIDE MI BOLT OR ®L8: iY/ . (IZ61, W/ i/4"p 20TRUS5HEAD BOLT s (SEE SCHEDULE FOR SPACING). WALL AMOUNTING LN__SWLAT/ON (D. M.) —E D. — \\ POURED CONCRETE REQUIRED i ' 1 ' Mop PANEL L. (SEE SCh 3 f 9 POURED CONCRETE REQUIRED RW/BUILDEX TAPCONS OR POWERS FASTENING CAUL-!NS E D. a D. (SEE' SCHEDULE FOR SPACING). CEILING & FLOOR MOUNTING INSTALLATION SECTION 5 SECTION 2 -/NSOR ELCO-- TEXTRON PAWELMAlE (SEE SCHEDULE FOR SPACING)_ 1iW/BUILDEX 7APCONS OR POWERS FASTENING CALK -INS-- E D-- (SEE SCHEDULE FOR SPACING). n E POURED CONCRETE, \\1k �'d 500' ! REQUL i i 1/4 0-20 x 3/4' BOLTS W/ 7/8' x �^�y 3132' WING NUT + J` , ID ® 12' o.c. 1' MirL ' MARATION 7 E10S11NGAll GLASS J' IV= E PANEL LENGTH (SEE SCHEDULE) 1/4if-20 x 3/4= BOLTS W/ 7/8' x 3/32' WING NUT 6 12' O.C. .5D0' Cont. BUILD OUT INSTALLATION SECTION 3 SIDE WALK BOLTS. ARE 3140x31,32"MICK HERO MACHINE SCREW W/LENGTH AS PER NOTES A2 ek 8.2 (SHEET 1) TRUSS HEAD BOLTS ARE 1 2 0x1 8'THICK HEAD MACHINE" SCR&V WLfNG> AS PER NOTES A.2 & 8.2 (SHEET 1) E. D = EDGE DISTANCE (SEE SCHEDULE ON SHEET 4 OF 5) INSTALLATION. DETAILS SCALE.- 318" = 7 " 0B NOTE FOR CO,NB/NAT10N OF SECTIONS WALL/FLOOR/CEILING MOUNnNG SECTIONS CAN BE COMBINED IN ANY WAY TO SUIT ANY INSTALLATION. FOR 4 1/4 0-20 x 1" j S. S ff. S.W/' ' i i 7/8' x 3/32' WING NUT (p 12' o.c. Tt' Min, i TO EXNGGLASS i I 7,0N13- UT a EVERY STUD 0 12' O. 0. i f t ALTERNATE LEG LOCATION 1, �" { 7.ODO�r I POURED CONCRETE —? 1 E REQUIRED DNS OR E i ILK -INS FACING). FLOOR MOUNTING II SECTION 4 FLORIDA 8UILDINC CODE ( Non Mox. PANEL LENGI'If (SEE SCHMU4E) J IF. D. Hurricane Z, MAXIMUM A.S.D. DESIGN PRESSURE RATING (n s f) WITH WOOD FRAME STRUCTURES * MAXIMUM ASO' DESIGN PRESSURE RAWNG (As.t) Hox• PANEL LENGTH L 00 .� .093' CLEAR LOW SWRI! PANEL ANCHORS SPACINGS 'S' (in.) t7K SECAON 4 (BOTTOA!) /E 0"12' +28.0, -28.0 10'-O" 7'12" t28.0, -30.0 9'--8' 7' 12' 12' +30.01 -35.0 8'-11 " 7" 12' 12' +35.0, -40.0 8'-4' 7' 12' 12^ +40.0. -45.0 7- 11' 7" 12' 12- +45 0, -50.0 7" -6" 7- 12' 12' 5- C 7'-2' 7' 2 +55.0. -60 0 6'-:0" 7' 12' 12" *60.01 -65.0 67 7- 12" 12- +5aO, -70.0 7- 12" 12' +70.0, -75.0 5'-J0' 7' 12' 12" +75.0, -80.0. 5'-6" 7" 12" 12' +80.0. -85.0 5'-2" 7" 12' 12' +85.0, -90.0 4'-f1' 7- f2' 12' +90.0, -95 0 4'-8" 7' f2' 12' +95.0, -100.0 4'-5' 7' 12' 12' +100.01 -105.0 4'-2" 7" 12' 12- +105.0, -110.0 4'-0- 7' 12' 12" On. PANEL LENGTH IS 3'-O" **MAX/MUAf ANCHOR SPACINGS ARE VAUD FOR 3 1/2' EDGE DISTANCE. FOR E D LESS THAN 3 112 ;, REDUCE ANCHOR SPACING BY MULTIPLYING SPACING SHOWN ON SCHEDULE BY THE FOLLOWING FACTORS.' (NOTE : Min. E. D. FOR CALK -IN ANCHORS IS 2. 1%2:). FOR THIS OPERATION TO BE POS18L& REDUCED SPACING OBTAINED USING FACTOR SHALL NOT BE LESS THAN MINIMUM SPACING INDICATED FOR EACH ANCHOR TYPE AT ANCHORS LEGEND. FACTOR ACTUAL E. D. TAPCON/ PANELMATES CALK IN J. .86 75 2 112- .71 50 2` 1 ,50 - AMC -HORS -LEGEND ANCHOR ANCHORS MIN. TYPE SPACING TAPCON/ . 3.0" PANELW ES CALK-W Z.5" PANLI 1- Min. 2" x 4' x .125' 3105-H14 OR 6063-76 ALLOY Cont. alum. ANGLE CASE A (Plan) POURED CONCRETE OR CONCRETE BLOCK WALL REQUIRED. \ 2.500 r - Min. CONCRETE ANCHORS E 2.500" 12 oa (;j Min. Wt� 3 1.iIDo I -ALTERNATE 2" x 2' x 0.55' TO 2" x 5' x .055- Cbnt. Alum. ANGLE OR .030' 3105-H154 SHEET METAL Alum. BENT PLATE POURED CONCRETE 4 f OR CONCRETE BLOCK #{ N/ALL REQUIRED. VARIES ? �� 2 OR [ .� ►�ORR r CONCRETE ANCHORS �� OR ODOR?� (7 )OR O 12" o.c. �/ POURED. CONCRETE 'I OR CONCRETE BLOCK 1WALL REQUIRED. -A " 2s 70' ' Amin. t � y� 7 VARIES L 2' LEG LOCATION CASE C (P_ Odn ) 2' x 3' x .093' 3105 H-14 OR 6063-TS AL.LOY Con'. Alum. ANGLE ivlTF! ANCHORS 0 1z- 0. C. , 1.000" a 1/4- GAP 1.000- CASE D (Plan) i m POURED CONCRETE OR CONCRETE BUCK WALL REQUIRED 4' x 4- x .072" 3105-HT4 OR D 80LT 5063-T6 ALLOY f ® 24' O C Cont Alum. ANGLE. JY1 JACKNOT 01W CASE 8 (Plan) POURED CONCRETE" - OR CONCRETE BLOCK 1YALL REQUIRED. ;-- X = B.O. DISTANCE CASE E (Plan) SCALE- 1/4- = 1'" END CLOSURES DETAILS SCALE' 114" = 1 FLORIDA BUILDING_ CODE ( Nan High Velocity Hurricane HEADER 1 ' Afin. S SEPARA770M TO DOSfivG GLASS 1/4 0-20 ELCO male/female PANELAVATE 0 12' ox. %/ 1 7/8' Min. PENEM4770N. u Max. PANEL LENGTH (SEE' NOTES BELOW) 1/410-20 ELCO mote/female PANELWE 0 12' aC. W/ 1. 7/8' On. PENE7R4710N AT MIDWIDIN OF PLATE: WALL AMOUNTING (D. M ) . ALTERNATIVE 1 NOTE FOR COMBINATION OF SECTION: WALL MOUNTING SECTIONS CAN BE COMBINED IN ANY WAY TO SUIT ANY INSTALLATION. 1/4`0-20 ELCO mole/female PANEUMIF ® 6' ox W/ 1 7/8' Min. PENETRATION OR #14 S.S. HEX WASHER HFAD WOOD SCREWS W/ 1 1/2" Min. PENE7RA7101V & 6' ox. 7/8' x 3/32' WING NUT & EVERY STUD 12' O. C. STAGGERED TO PAA!"ATE. 1' Min. j _ SEPARATION+ TO EXIS7ING GLASS WALL MOUNLWG INSTALLATION ALTER, jVAVVE 1/4 0-20' x I* S•s. M. S W/ 7/8" x 3/32 I WING NUT ® 12' o.C. 1/4ID--20 ELCO mole/femole PANELMATE 0 6' ox W/ 1 7/8' Min. PENETRATION OR #14 S.S. HEX WASHER HEAD WOOD SCREWS W/ 1 1/2' Min. P.ENEM770H oy 6' o.C, ® /,fowmiH OF PLATE. -WALL MOUNTING IIdSTALLATIOhf ALTERNATIVE 3 NOTES I. INSTALLATION ARE ONLY VALID FOR MAX, A.S.D, DESIGN PRESSURE RATING AND PANEL'S LENGTHS AS PER SCHEDULE SHOWN ON SHEETS 4 OF 5. 2. FOR WOOD FRAME CONSTRUCTION: WOOD MEMBERS TO BE SOUTHERN PINE No. 2, W/ SPECIFIC DENSITY .OF 0.55 OR EQUAL. HEADER 114C-20 ELCO male/femole PANELMATE @ 6' ox W/ _ f 7/8' Min. PENETRATION OR f14 S.S. HEX WASHER HEAD WOOD SCREWS W/ jf14 x 1 3/4' S.S. HEX, I%ASNER 1 1/2' Min. PENE7R4710N & 6' ox, HEAD WOOD SCREWS tY/ 1 1/2' Min. PENE7R47ON ® 6' o.a. I .Soo' 1/4 0-20 x 3/4'. BOLTS W/ 7/8" x 3/32' PIING NUT 0 12' am �-- SEPARA71DN j TO EXISTING GLASS t i BUILD OUT INSTALLATION ALTERNATIVE 4 SEPARATION TO OWING GLASS 1/4 0-20 x 3/4'. BOLTS W/ 718' x 3/32" WING NUT 0 12' ox. sea" CJ 1/40-20.ELCO mote/female PANELMATE & 6' ox W/ 1 7/8' Min. PENETRATION OR 114 S.S. HEX WASHER HEAD WOOD SCREWS W/ 1 1/2' Min, PENETRATION ® 6' ox. 0 MIDWIOTH OF PLATE BUILD OUT _INSTALLATION ALTERNATIVE 5 SCALE. 1 l 1/4 II ZD x 1 BOLTS W/ 7/8' x 3/32' WING NUT 0 12' o. c. I' Min. �SEPAR477ON _ TO MS77NG GLASS 1/40-20 x 3/4' BOLTS YJ/ 7/6' x, 3/32' WING NUT a 12' ox. 2' x 6' WOOD (NO FIN SH RALLOWEDJ / OCn f _ #14 x 1 3/4 SS, HEX IVASHE HEAD WOOD SCREWS W/1 1/2' PENETRATION 0 6' o.C. 4' x 8' (Min.) EX1S77%. WOOD BEAM REQUIRED. STRUCTURAL ADEOVACY -OF EX/S77NG WOOD BEAM TO BE CL:RT/nED BY REGISTERED ENGINEER OR ARCHITECT PRIOR TO SHUTTER INSTALLATION. Mig max. PANEL `LENGTH (SEE N072:5 BELOW) 4 I t i i CEILING do FLOOR MOUNTING INSTALLATION ALTERNATIVE 6 FLORIDA BUILDING CODE ( Non High Velocity Hurricane