NOTICE OF ACCEPTANCE (NO?
Maxim Industries, Inc.
1630 Terre Colony Court
Dallas, TX 75212
RESOURCES (RER)
MIAMI-DADE COUNTY.
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/ecoikonly
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted �as been reviewed and accepted by Miami -Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform. in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or supend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or water}}al fails to meet the requirements of the applicable building code.
This product is approved as desctibed herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Model DC* Curb Mount & DSF Self -Flashing Aluminum Skylights
APPROVAL DOCUMENTf Drawing No. MAX0003, titled "Curb Mounted and Self Flashing Skylights",
prepared by Maxim Industries, Inc, sheets 1 through 5 of 5, dated 12/03/2013, with revision B dated
07/09/2015, signed and sealed by Robert J. Amoruso, P.E., bearing the Miami -Dade County Product Control
revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County
Product Control Section. /
MISSILE IMPACT R. TING: Large and Small Missile Impact Resistant
LABELING: Each unit/shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series and follov� ng statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein. /
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur -after the expiration date or if there has been a revision or change in the
materials, use, and/or'manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or/ other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade'County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 14-0318.01 and consists of this page 1 and evidence page E-1, as well as approval
document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 15-0715.08
MIAMI•DADE COuNTY Expiration Date: February 20, 2019
Approval Date: September 10, 2015
-j %1$ Page 1
'ICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. MAX0003, titled "Curb Mounted and Self Flashing Skylights", prepared by
Maxim Industries, Inc, sheets 1 through 5 of 5, dated 12/03/2013, with revision B dated
07/09/2015, signed
gned and sealed by Robert J. Amoruso, P.E.
B. TESTS "Submitted under NOA # 14-0318.01"
1. Test reports on\l) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5)�,Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked 4ip drawings and installation of Self Flashing and Curb Mount Plastic
Glazed Unit Skylights, prepared by Architectural Testing, Inc., Test Report No. D1032.01-
801-18, dated 10/02/2013, and revision 1 dated 02/24/2014, signed and sealed by Vinu J.
Abraham, P.E.
"Submitted under NOA # 13-12I Z24"
2. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static. Air Pressure Test; Loading per FBC TAS 202-94
3) Water,,,Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation of Self Flashing and Curb Mount Plastic
Glazed Unit Skylights, prepared by Architectural Testing, Inc, Test Report No. D1032.01- .
801-18, dated 10/02/2013, signed and sealed by Vinu J. Abraham, P.E.
C.. CALCULATIONS "Submitted under NOA # 13-1217.2411
1. Anchor calculations for substrate installation prepared by PTC Product Design Group, LLC,
dated 12/03/2013, signed and sealed by Robert J. Amoruso, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of acceptance No. 12-0605.05 issued to Bayer MaterialScience LLC (MA), for their
Makrolon Polycar6onate Sheets, approved on 12/06/2012 and expiring on 08/27/2017.
2. Notice of acceptance No: 12-0110.04 issued to Palram Americas, Inc, for their Corrugated and
Flat Polycarbonate Panels, approved on'02/23/2012 and expiring on 01/22/2016.
F. STATEMENTS
1. Statement letter of code conformance to
issued by PTC Product Design Group, I
Amoruso, P.E.
E -1
51 edition (2014) FBC and of no financial interest
dated 07/0912015, signed and s aled by Robert J.
Carlos M. Utrera, P.E:
Product Control Examiner
NOA No. 15-0715.08
Expiration Date: February 20, 2019
Approval Date: September 10, 2015
MAXIM INDUSTRIES, INC.
CURB MOUNT & SELF -FLASHING SKYLIGHTS
INSTALLATION ANCHORAGE DETAILS
GENERAL NOTES:
1. THIS PRODUCT IS DESIGNED TO COMPLY WITH THE HIGH VELOCITY HURRICANE ZONE (HVHZ)
REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE (FBC). THE PRODUCT DETAILS
CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORTATID1032.01.801-18AND
ASSOCIATED LABORATORY DRAWINGS. .
2. ADEQUACY OF THE EXISTING STRUCTURAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE,
OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE STRUCTURE IS THE
RESPONSIBILITY OF THE ENGINEER ORMCHITECT OF RECORD.
3. IN AREAS WHERE WIND-BORNE DEBRIS PROTECTION REQUIREMENTS EXIST, USE OF AN APPROVED IMPACT
PROTECTIVE SYSTEM IS NOT REQUIRED.
4.MATERIALS:
4.1. SKYLIGHT FRAME MATERIAL: 6063-TS EXTRUDED ALUMINUM.
4.2. SKYLIGHT INNER AND OUTER DOME MATERIAL: BAYER MATERIALSCIENCE MAKROLON POLYCARSONATE
(NOA 12-M5.05) OR PALRAM AMERICAS POLYCARBONATE (NOA 12-0110.04)
S. DESIGNATION "O' STANDS FOR THE A FIXED PANEL
6. IN ACCORDANCE WITH THE CURRENT EDITION OF THE FBC, WOOD BUCKING SHALL HAVE BEEN
PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES.
7. DISSIMILAR METALS INCLUDING FASTENERS THAT MAY COME INTO CONTACT WITH ALUMINUM WINDOW
FRAMING SHALL HAVE BEEN PROTECTED IN MANNER TO PREVENT CORROSION. FASTENERS SHALL BE
MADE OF ACORROSION RESISTANT MATERIAL OR HAVE ACORROSION RESISTANT COATING CONSISTENT
WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE.
TABLE OF CONTENTS
SHEET
DESCRIPTION
1
GENERALAND INSTALLATION NOTES
2
DGt CURB MOUNT-_ ELEVATION
3
DOM CURB MOUNT -SECTIONS
4
DSF SELF -FLASHING -ELEVATION
5
DSF SELF -FLASHING - SECTIONS
INSTALLATION NOTES:
I. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION DETAILED.
2. THE MINIMUM NUMBER OF INSTALLATION ANCHORS ARE BASED ON THE FOLLOWING:
2.1. AS REQUIRED ON SHEET 3 (CURB MOUNT) AND SHEET 5 (SELF -FLASHING) BASED ON CORNER END DISTANCE
AND ON CENTER SPACING.
2.2. MINIMUM OF ONE FASTENER PER SIDE AND MINIMUM FOUR FASTENERS PER SKYLIGHT ARE REQUIRED BASED ON
SKYLIGHT SIZES SMALLER THAN TESTED AND SHOWN ON SHEETS 2 AND 4.
3. FORINSTALLATION OF SELF -FLASHING SKYLIGHT ONTO WOOD ROOF DECK USEN12 WOOD SCREWS OF
SUFFICIENT -LENGTH ACHIEVE 1 318INCH MINIMUM EMBEDMENT. MINIMUM EDGE DISTANCE IS 7/8 INCH.
4. FOR INSTALLATION OF CURB MOUNT SKYLIGHT ONTO WOOD CURB, USE #12 WOOD SCREWS OF SUFFICIENT
LENGTH TO ACHIEVE 1 3181NCH MINIMUMEMBEDMENT. MINIMUM EDGE DISTANCE IS 718INCH.
3. FOR INSTALLATION OF CURB MOUNT SKYLIRB ONTO WOOD ROOF DECK USE 12D (0.148"MIN. SHANK
DIAMETER) BOX OR COMMON NAILS OR fib WOOD SCREWS-OFSUFFICIENT LENGTH TO ACHIEVE 2 Ila INCH MINIMUM
EMBEDMENT. MINIMUM EDGE DISTANCE I$ SH6INCH.
6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING UTNOT LIMITSTUCCO,
FOAM, BRICKVENEERAND SIDING.
7. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON WOOD SUBSTRATE MATERIALSVNTII—
MINIMUM SPECIFIC GRAVITY OF 0.55.
8. TOE -NAILING OF CURB MOUNT SKYLIGHT CURB ONTO WOOD ROOF DECK (NOTES ABOVE) SHALL MEET THE
FOLLOWING REQUIREMENTS FROM THE 2005 NOS FOR WOOD CONSTRUCTION.
8.1. LENGTH (L)AS REQUIRED TO MEET P. Le AND Lm REQUIREMENTS.
8.2. MIN. EMBEDMENT (P) IS 2.13' FOR BOX NAILS AND 1.6W FOR COMMON NAILS WITH 0.148' DIAMETER
8.3. MIN. Le IS 1.33" FOR BOX NAILS AND 1.0"
FOR COMMON NAILS WITH 0.148" SHANK DIAMETER.
8.4. MIN. Lm IS 2.13" FOR BOX NAILS AND 1.6'
FOR COMMON NAILS WITH 0.148" SHANK DIAMETER.
DESIGN PRESSURE RATING (PSF)
IMPACTRATINO
LARGE and SMA LL
+40.0-75.0
MISSILE IMPACT
L3 r
�.p
0'
J %C
U rrrn
N el
PRONICT REVISM
as eueipl>Ilq wft the Plomids
A.MM.� S-0 IS•OB 9
Mrm" CDetre1
Robert J.Ammw, RE
Florida P.E. No. 49762
No
DCM CURB MOUNT - ELEVATION DESIGN PRESSURE _ +40psf / -75psf
Comer Detail U
(see Detail #3 & #4)
a
f— Top Frame Fastener
#12X1.5" m < z
(see BOM #5)
Top Frame FastenerEr,
m / / (see BOM 46) 0
W
Erl Cn
n
Frame Detail to 0
c O (see Detall #1 & #3) a o
o z Q
�
2 � �
d � .
j
/ Angle Detail v
oi
(see Detail #1 & #4) z � g in
¢�
DL Opening = 92.5" o a�
Glazing Detail `` 1
' (see Detail #1 & #2) l
U gFrame I a
Width = 97.5"
Bill of Materials: r raw "+m�a<10 tr'
off: 1. 6063-T5 Extruded Aluminum Frame mitered and welded at four corners. Manufacturer: AFCO Part #4950 Iram;,ec ,
1. This skylight Is designed to comply with all wind zones, including the HVHZ, of the Florida 2. 6063-T5 Extruded Aluminum Angle mitered and welded at four comers. Manufacturer: AFCO Part #4843 Am►+!=tm
Building Code. 3. Dow Corning 795 Silicone Building Sealant located between aluminum angle & glazing (glass bite)
2. This skylight meets small & large missle Impact resistance (TAS-201/TAS-203) 4. 0.125" UV Enhanced polycarbonate domes. Rise varies but is not less than 10% of the smaller M
and no other protection Is required. dimension of the length or width. Test specimen = 10" outer dome & 7" Inner dome.
3. All framing and roof deck is by others and must comply with the Florida Building Code. Manufacturer: Bayer MaterialSdence LLC (MA) or PalRam Americas
4. All sizes equal to or less than the test size total square footage are to be accepted 5. #12 x 1" Stainless Steel Tapping Screw with neoprene gasket. Fasteners located 12" from each comer,
maximum 12" on center. Minimum one fastener per side and minimum four fasteners per skylight. RobertJ.Am& UW. P.E.
under this NOA. 6. #10 X 0.375" Stainless Steel fasteners 4" from each corner, maximum 12" on center. FwMa P.E. no. 49762
5. Fasteners used to attach skylight to wood curb are to be minimum #12 stainless 7. Schnee -Morehead SM5127 0.6250" X 0.125" Sealant tape.
steel wood screws with minimum embedment of 1.375" 1
No
STATE
DCM CURB MOUNT - SECTIONS DESIGN PRESSURE = +40psf / -75psf
Detail #1:
Frame, Angle & Glazing Section Detail
0.125" UV Enhanced Polycarbonate Domes, Rise varies
but Is not less than 10% of the smaller dimension of the
length or width. Test Specimen - 10" Outer&7' Inner.
Dow Corning 795 Silicone Sealant between retaining
angle and top dome. Glazing bite = 1.75"
Schnee Morehead SM 5127 sealant tape. 0.625"
width applied continuously around the per(meter
of the dome set.
.060" Extruded Aluminum Shape
Sealant to be minimum 0.12S" tall head to create constant
seal between extruded frame and top of curb. (by others
or Included by Maxim as per note below)
Curb Buck Exterior Flnlshmg (by others)
Curb Buck: See;• Note Below
* Minimum distance = 4" from aluminum frame to
roof surface for shingles or BUR without Insulation.
For insulation and roof Ule add Insulation or roof the
thickness to 4" minimum height
** Curb buck - Nominal Southern Yellow Pine
2X 6 minimum with skylight set on buck with minimum
1/8' tall bead of building sealant. installation fasteners are
Stainless Steel #12 PH or HH Wood Screw with minimum
1.375" embedment and 0.875" Edge Distance looted 3"
from each corner and maximum 8" on center. This curb
buck Is an optional wmponentdnduded In the NON-
--Anchoring of the curb buck must be Per the Florida
Building Code, See Installation Notes on Sheet 1.
Detail #2
Glazing Detail
1112 x 1" Stainless Steel Tapping Screw.with neoprene gasket
Fasteners located 12" from each comer, maximum 12" on center.
Minimum one fastener per side and four fhsteners per skylight.
1.75" X 1.75" X.060" Extruded Aluminum Retaining Angle
010 X 0.375" stainless steel fastener. 4" from each _
come, maximum 12" on center.
Minimum Stainless Steel #12 PH or HH Wood Screw with minimum 1.375"
embedment and 0.875" Edge Distance, 3" from each comer & maximum a" on
center. Pre -punched 1/8" holes by Maxim for fasteners (by others or optional
accessory)(See installation Notes on Sheet 1.)
Minimum 12D (0.14W Shank Dia.) Common Nag or 96 Stainless Steel Wood
Screw 6" O.C. with Minimum Embeddment of 2.17 and 0.S625" Edge Distance
(by others or optional aceessory)(See Installation Notes on Sheet 1.)
Roof deck. (by others)
«R Roof deck and framing by others. All
roof details shall comply with the Florida
Building Code
0.125" UV Enhanced Polycarbonate Dome. Rise varies
but Is not less than 10% of the smaller dimension of
the length or width. Test Specimen = 10".
Schnee Morehead SM 5127 sealant tape. 0.625"
width applied continuously around the perlineter
of the dome set.
0.125" W Enhanced Polycarbonabe Dome. Rise varies
but Is not less than 10% of the smaller dimension of
the length or width. Test Specimen = 7".
Detail #3
Aluminum Shape Weld Detail
AFCO Part #AF-4950
Minimum
—.2511weep hole
Matotala Dp height- at each corner.
no "V"weld acceptable.
Location of heiiare TIG weld.
Detail #4
Aluminum Angle Corner Weld Detail
AFCO Part #AF-4843
Location of heliarc TIG weld.
o' -
j Zo
ZO
U-N < N m
og �
w rn U" BEE
Lu z ec
��a
9- • �
PROD(1cr.REvtsFD
r ooviplrt�grith theFlufda
MiaaitJa+oot
no rici J.A P.E.No.4 P.E.
FbiNa No.46752 �
,tt1111t111t/I
't SINES 4�♦i♦♦
..........
b�(`'ENS.�'0'9p♦��i
No 49752 :�O
DSF SELF -FLASHING - ELEVATION DESIGN PRESSURE _ +40psf / -75psf g a
Corner Detail
(see Detail #3 & #4)
W
-- — — Top Frame Fastener �
#12X1.5" n"
/ Z _ (see BOM #5)
Top Frame Fastener
M L (see BOM #6)
TE CM
� C O �- � I. g O
a
oFrame Detail ;
O (see Detail #1 & #3) i
o =o �a
/ () N N Q N m
/ LE
�— Angle Detail '� � N 5
(see Detail #1 & #4) N.o LE z g
DL Opening = 92.5" z W w
Glazing.Detall o h
m '5�(see Detail #1 & #2)
Frame ,II 1
Width = 97.5" 1 IN
Notes: Bill of Materials: 1 9 1ff ��
1. This skylight Is designed to comply with all wind zones, Including the HVHZ, of the Florida 1. 6063-T5 Extruded Aluminum Frame mitered and welded at four corners. Manufacturer: AFCO Part #4951
2. 6063 T5 Extruded Aluminum Angle mitered and welded at four corners. Manufacturer: AFCO Part #4843 p�CI xavu�
Building Code. . .OlyftI'm tt "M&
2, This skylight meets small & large missle Impact resistance (TAS-201frAS-203) 3. Dow Corning 795 Silicone Building Sealant located between aluminum angle & glazing (glass bite) 9d16@cm
4. 0.125" UV Enhanced polyorbonate domes. Rise varies but is not less than 10% of the smaller C
and no other protection is required. 1
3. All framing and roof deck is by others and must comply with the Florida Building Code. dimension a the length or width.cle Test specimen = 10" outer dome & 7" Inner dome.
4. All sizes equal to or less than the test size total square footage are to be accepted Manufacturer: Bayer l Tapping Screw
witLLCh
(MA) re a arialkarn Americas. cam
q q 9 p S. #12 x 1" Stainless Steel Tapping Screw with neoprene gasket. Fasteners looted 12" from each corner,
under this NOA. maximum IX'on center. Minimum one fastener per side and minimum four fasteners per skylight.
5. Fasteners used to attach skylight to the existing roof structure are to be minimum #12 stalnless 6. #10 X 0.375" Stainless Steel fasteners 4" from each corner, maximum 12" on center. RobMIA UM.P.E.
steel wood screws with minimum embedment of 1.375" 7. Schnee -Morehead SM5127 0.6250" X 0.125" Sealant tape. FbWa P.E. Nu. 49752
No 49752
6. STATE' F
DSF SELF -FLASHING - SECTIONS DESIGN PRESSURE = +40psf / -75psf
Detail #1:
Frame, Angle & Glazing Section Detail
0.125" W Enhanced Poycarbonale Domes. Rise varies
but is not less than 10% of the smaller dimension of the
length or width. Test Specimen = 10" Outer & 7" Inner.
Dow Corning 795 Slllmne Sealant between retaining
angle and top dome. Glazing blte = 1.75"
Schnee Morehead SM 5127 sealant tape. 0.625"
width applied continuously around the perimeter of
the dome set
.060" Extruded Alumimmn Shape
* Minimum distance = 4" from aluminum frame to
roof surface for shingles or BUR without Insulation.
For Insulation and roof Ole add Insulation or roof Ole
thickness to 4' minimum height
Detail #2
Glazing Detail
412 x L" Stainless Steel Tapping Screw with neoprene gasket. Fasteners located 12" from
each comer, maximum 12" on center. Minimum one fastener per side and four fasteners per
skylight.
1.75" X 1.75' X .060" Exuded Aluminum Retaining Jingle
f 010 X 0.375" staiuless steel fastener. 4" from each
corner, maximum Won center.
Detail #3
Aluminum Shape Weld Detail
AFCO Part #4951
Minimum
.25" weep hole
_
Maintain lip height- at each corner.
no IV. weld acceptable.
Stainless Steel Mlnlmum #12 PH or HH Wood Screw with minmum 1.375"
embedment and 0.875' Edge Distance, 3" from each comer & maximum 8" on Location of hellareTlG weld.
center. Pre -punched 1/6" holes by Maxim for fasteners (See Installation Notes on
Sheet 1.)
Roof deck. (by others)
+'-Roofed framing by others. All
roof details shall comply with the Florida
Building Code
Detail #4
Aluminum Angle Corner Weld Detail
AFCO Part #4843
0.125" UV Enhanced Poycarbonate Dome. Rise varies
but Is not less than 10% of the smaller dimension of the
length or width. Test Specimen = •10".
Schnee Morehead SM 5127 sealant tape. 0.625' Location of hellare TIG weld.
width applied continuously around the perimeter
of the dome set
0.125" UV Enhanced Poycarbonate Dome. Rise varies
but Is not less than 10% of the smaller dimension of the
length or width. Test Specimen = 7".
W
a
Nil
N
m
<
d
:n` II 2I 0
PR.OIDUC1' RWVISRD
tirOdlqdBROCode die F7aeida
Acceptance *�g
M�IrntUf de PmOud dwr—
Robed J. Amoroso. P.E
Fbdda P.E. No. 49752
No