Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTI I SCANNED Business & Professional Regulation BCIS Home ! Log In ! User Registration ! Hot Topics ! Submit Surcharge ! Stats & Facts ! Florida _ .J`- Product Approval USER: Public User Product p_RMygl Menu > Product or AQpilcation Search > epplica[lon List > Application Detail 1, OFFICE OF FL # FL12328-R8 SECREURY Application Type Revision Code Version 2017 Application Status Approved Comments Archived 0 Product Manufacturer TAMKO Building, Products, Inc. Address/Phone/Email I PO Box 1404 I Joplin, MO 64802 (417) 624-6644 Ext2305 kerri__gden@tamko.com Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Kerri Eden kerrL_eden@tamko.com Kerri Eden PO Box 1404 Joplin, MO 64802 (417)624-6644 Ext2305 kerri_eden@tamko.com Roofing Underlayments Tit - O'nHOW ABOUT0600 roan Division -coWrACi'Dam RECEIVED APR 18 2018 ST. Lucie County, Permitting Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity i UL LLC Quality Assurance Contract Expiration Date 01/07/2019 Validated By Locke Bowden P.E. iValidation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pd Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4869 2016 ASTM D6380 2003 TAS 103 1995 Equivalence of Product Standards Certified By Approved for use in HVHZ: Yes I FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Approved for use outside HVHZ: Yes ; Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party, Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf i Created by Independent Third Party. Yes 123 No. 3 M I Asphalt saturated organic felt L' is of Use Installation Instructions Approved for use in HVHZ: Yes FU2328 R8 II TBP14001 4 2017 FBC Eval Report TAMKO Underayments finaLpdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of e. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Created by Independent Third Party: Yes 12328.8 No. 30 UL Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Approved for use outside HVHZ: Yes I Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Other: See evaluation report for limits of use. Created by Independent Third Party: Yes Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pd Created by Independent Third Party: Yes i 12328.9 TAM -FELT I Alternate to ASTM D 226, Type II underlayment Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.p_df I Created by Independent Third Party: Yes i 12328.10 TW Metal and Tile Underlayment self -adhering modified bitumen underlayment Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A I Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001,4 2017 FBC Eval Report TAMKO Underlayments final.odf Created by Independent Third Party: Yes I 12328.11 TW Underlayment self -adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ:IYes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO Underlayments final.pd Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO Underlayments fiinal.Rdf Created by Independent Third Party: Yes i Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coo ri�7c ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility. Statement :: Refund Statement I Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: TAMKO BUILDING PRODUCTS, INC. P.O. Box 1404 1 Joplin, MO 64802 (417) 624-6644 j hftp://www.tamko.com Quality Assurance: UL LLC (QUA9625) SCOPE ; Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE, 6T" EDITION (2017) Issued October 19, 2017 Category: Subcategory: f Roofing i Undedayments 11 Code Sections: 1507.1.1 Properties: Physical propertes PRODUCT DESCRIPTION I i i TAMKO® ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO® ASTM Tile ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO® Master Smooth TAMKO® Moisture Guard® TAMKOO No.15 ASTM Asphalt Saturated Organic Felt TAMKO® No.15 UL Asphalt Saturated Organic Felt A O® No. 30 AS As alt Saturated Organic Felt ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane with a mineral surfacing and a removable. release film on the adhesive side and removable selvedge release tape. ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ASTM; D 226, Type I underlayment constructed from a non -perforated organic felt that is saturated with asphalt. ASTM D 226, Type 11 underlayment constructed from a non -perforated organic felt that is saturated with asphalt TAMKO® No. 30 UL ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt I TAMKOO TW Metal and 361f-adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. i TAMKO® TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. TBP14001.4 FL12328-R8 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein: CREEK TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments TECHNICAL SERVICES, LLC l 1 TAMKO® TAM -FELT Alternate to ASTM D; 226, Type I and Type II underlayment constructed from a non - perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. I Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. j The minimum application temperature shall be 50°F except as follows: a) The minimum application temperature of TAMKO@ TW Metal and Tile Underlayment and TAMKO@ TW Underlayment shall be 40-F` b) The minimum application temperature of TAMKO@) Moisture Guard® shall be 35°F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKO@ ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall exposure exceed 30 days. I' Exception: TAMKO@ TW Metal and Tile Underlayment may be exposed for a maximum 90 days. Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. i All roof coverings shall be mechanic1ally fastened through the underlayment to the roof deck. Alloy ble Roof Coverinns- I Metal Roof . Mineral Wood 1 Asphalt Panels and Surfaced Roll Shingles and Slate Clay and Underlayment {` Shin les Shingles Roofing Shakes Shingles Concrete Tile TAMKO@ ASTM Slate Y' N N N N Y Surfaced Roll Roofing 1 TAMKO@ ASTM Tile N N N N N Y Underlayment TAMKO@ Master Smooth i Y' N N N N N i TAMKO@ Moisture Guard@ Y N N N N N TAMKO@ No. 15 ASTM Asphalt Saturated Organic Y Y Y Yz N N Felt TAMKO@ No. 15 UL Asphalt Y Y Y YZ Y N Saturated Organic Felt o. 0 ASTM . Asphalt Saturated Organic' Y Y Y Y Y Y Felt T O@ No. 30 UL Asphalt Y Y Y N Y N Saturated Organic Felt TAMKO@ TW Metal and Tile Y Y N N N Y Underlayment TAMKO@ TW Underlayment Y Y N N N N TAMKO@ TAM -FELT Y N N N N N Notes: 1) Open valley applications per 1507.2.9.2 2) Wood shingles only TBP14001.4 FL12328-R8 Page 2 of 4 This evaluation report, Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC LIMITATIONS TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated, the minimum Iroof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding Ispecific exposure limits for each underlayment. 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES I Enti I Report No. Standard Year PRI Construction Materials Technologies (TSTG049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 20D3(2013) PRI Construction Materials Technologies (TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (T$T6049) TAP-222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies (TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies (TST6049) TAP-387-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC (TST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FL12328-138 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any+product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I 1 I CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT I The products evaluated herein by Zachary R. Priest Code, 61h Edition (2017) as evidenced in the reference TAiVIKO BUILDING PRODCUTS, INC. TAMKO Underlayments P.E. have demonstrated compliance with the Florida Building I documents submitted by the named manufacturer. RY R. •I pR�i,� No 74021 ' 13 STATE OF CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it a evaluation. CREEK Technical Services, LLC is not owned, operated, or Zachary R. Priest, P.E. does not have, nor will acquire, a fin Zachary R. Priest, P.E. does not have, nor will acquire, a fin _ 2017.10.19 12:15:58 _04r00t Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 a financial interest in any company manufacturing or distributing products under this by any company manufacturing or distributing products under this evaluation. interest in any company manufacturing or distributing products under this evaluation. interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001 A I FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.