HomeMy WebLinkAboutPRODUCT APPROVALSCANNEDBY
F
BCIS Home I Log In I User Registration I Hot Topirs I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
O
ra
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Appllcatlon List > Application Detail
FL # I FL12328-118
Application Type Revision
Code Version 2017
Application Status Approved
I
I
Comments
i
Archived 0
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri_eden@tamko.com
I
I
Authorized Signature Kerri Eden
kerri_eden@tamko.com P4 EC E IV 5 0
�r t
Technical Representative i Kerri Eden APR t701j
Address/Phone/Email I PO Box 1404
1 Joplin, MO 64802
(417) 624-6644 Ext 2305 ST. Lucie County, Permitting
{ kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
it Roofing
Underlayments
Compliance Method I Evaluation Report from a Florida Registered Architect or a Licensed Florida
I Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden P.E.
L�J Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4869
2016
ASTM D6380
2003
TAS 103
1995
Equivalence of Product Standards
Certified By
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pff
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
7 No. 30 ASTM I Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ: Yes Underlayments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A / Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.8
No. 30 UL
Asphalt saturated organic felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.p�f
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.9
TAM -FELT
Alternate to ASTM D 226, Type II underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Approved for use outside HVHZ: Yes j
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Other: See evaluation report for limits of use. j
Created by Independent Third Party: Yes
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pd
j
Created by Independent Third Party: Yes
12328.10
TW Metal and Tile Underlayment
self -adhering modified bitumen underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments finalf
Approved for use outside HVHZ: Yes
Impact Resistant, N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. j
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
j
Created by Independent Third Party: Yes
12328.11
TW Underlayment
self -adhering modified bitumen underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Under ayments final.pfff
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copy right 2007-2013 State of Florida.:: Privacy Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do'not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communicatlon with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can he made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
. I.
CREEK ,
TECHNICAL SERVICES, LLC
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417) 624-6644,
htta://www.tamko.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKOO ASTM Slate ASTM D ,6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO@) ASTM Tile ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO® Master ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKO® Moisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKOO No.15 ASTM ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKO® No.15 UL ASTM D 226, Type I,underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
=Saturated
D 226, Type II underlayment constructed from a non -perforated organic felt that is
r ted with asphalt
TAMKO® No. 30 UL ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt
Organic Felt
TAMKO@ TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO®TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKO@ TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
i
APPLICATION METHOD i
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from 'any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F!except as follows:
a) The minimum application temperature! of TAMKO® TW Metal and Tile Underlayment and TAMKO®TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35°F.
347
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKO® ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO® TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof CoverinOS:
Metal Roof.
I, .Mineral
Wood
Asphalt
Panels and,
Surfaced Roll
Shingles and
State '
Clayand
Underlayment '
Shin les
Shingles-
Roofing
'Shakes .
Shi- les
concrete Tile
TAMKO® ASTM Slate
Y'
N
N
N
N
Y
Surfaced Roll Roofing
TAMKO® ASTM Tile
N
N
N
N
N
Y
Underlayment
TAMKO® Master Smooth
Y'
I N
N
N
N
N
TAMKO® Moisture Guard®
Y
N
N
N
N
N
TAM KO® No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
YZ
N
N
Felt
TAM halt
Y
Y
Y
YZ
Y
N
,SOurated Or wic Feft-�
—TMWO@) No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
TAMKOB No. 30 UL Asphalt
Y
Y
Y
N
Y
N
Saturated Organic Felt
TAMKO® TW Metal and Tile
Y
Y
N
N
N
Y
Underlayment
TAMKOB TW Underlayment
Y
Y
N
N
N
-N
TAMKOB TAM -FELT
Y
N
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only '
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKTAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described lin other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
EU&
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
TAP-192-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-193-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-214-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP-215-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
1A13-216-02-03
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-217-02-01 REV
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-218-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP-219-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP-220-02-01
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-222-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP-245-02-01
TAS 103
1995
1
ASTM D 4798
2011
PRI Construction Materials Technologies (TST6049)
TAP-311-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TA13-319-02-01.1
ACC 188
2012
PRI Construction Materials Technologies (TST6049)
TAP-387-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TA13-388-02-01
ASTM D 1970
2015a
UL LLC (TST9628)
13CA12269
ASTM D 226
2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
The products evaluated herein by Zachary R. Priest,! P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
111nuf11"
� p�Y R.
P R •
No 74021
:i'Z
STATE OF
Al
CERTIFICATION OF INDEPENDENCE
2017.10.19
12:15:58
—04r00r
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
I
END OF REPORT
TBP14001.4 FL12328-RB Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.