HomeMy WebLinkAboutROOF UNDERLAYMENTion
BCIS Home I Log In I User Registration I Hot Topics I Submit Silr,¢�i�ge�,I, �ta�Factg I., ublications I FBC Staff I BCIS Site Map I Links I Search
Florida ���1 �Q ����� pUnlrBnVlt�
Product Approval
la USER: Public User
Product Approval Menu > Product or Apoliwtion Search > flpnliwtiomList > Application Detail
7
FL #
FL12328-118
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
' 0
Product Manufacturer /
I
TAMKO Building Products, Inc.
Address/Phone/Email
PO Box 1404
i
Joplin, MO 64802
(417) 624-6644 Ext2305
+
kerri_eden@tamko.com
Authorized Signature
Kerr! Eden
kerri_.pden@tamko.com
r
Technical Representative I
Kerri Eden
Address/Phone/Email
PO Box 1404
i
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri_eden@tamko.com
Quality Assurance Representative/
Address/Phone/Email
Category
Subcategory
Compliance Method I
Roofing
Underlayments
RECEIVED
APR 18 2018
ST. Lucie County, Permitting
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
G Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date O1/07/2019
Validated By 1 Locke Bowden P.E.
i] Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
I
Equivalence of Product Standards
Certified By
i
FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments ffnal.pdf
Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4869
2016
ASTM D6380
2003.
TAS 103
1995
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328 No. 30 ASTM
Asphalt saturated organic felt
Imits of UseJYes
Installation Instructions
Approved for use in HVHZFL12328
R8 II TBP14001.4 2017 FBC Eva) Report TAMKQ
Unde yments final.pdImpact
Approved for use outside
Resistant: N/AVerified
By: Zachary R. Priest 74021
Design Pressure: N/ACreated
by Independent Third Party: Yes
Other: See evaluation repo
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva[ Report TAMKO
Underlayments final.p—df
Created by Independent Third Party: Yes
12328.8
No. 30 UL
Asphalt saturated organic felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.p!Lf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.Ddf
Created by Independent Third Party: Yes
12328.9
TAM -FELT
Altemate to ASTM D 226, Type II underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKQ
Underlayments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva[ Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.10
TW Metal and Tile Underlayment
self -adhering modified bitumen underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKQ
LJnderlayments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.11
TW Underlayment
self -adhering modified bitumen underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pcdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
Back Pdext
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer, Copy�ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses ale public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850AB7.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
CREEK1
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Quality Assurance:
SCOPE
TAMKO BUILDING f RODUCTS, INC.
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
UL LLC
Category:
Roofing
Subcategory:
Underlay
Code Sections:
1507.1.1
Properties:
Physical,
PRODUCT DESCRIPTION
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, C EDITION (2017)
Issued October 19, 2017
TAMKO® ASTM Slate AS
jM D 6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKOS ASTM Tile ASTM D 6380, Class M, Type I I underlayment constructed from an' organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKOS Master / ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKOS Moisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKOS No.15 ASTM
Asphalt Saturated
Organic Felt /
TAMKOS No./"5 UL
Asphalt Saturated
Organic Fel:-
"'4' IKM No. 30 ASTM
Asphalt Saturated
Organic ,Felt
TAMKOS No. 30 UL
Asphalt Saturated
Organic Felt
TAMKOS TW Metal and
Tile Underlayment
TAMKOS TW
Underlayment
TBP14001.4
rns evaluation report is provided for State of Flr�d
Technical Services, LLC of any product ch
This evaluation report does not express norr im�nrr;I ty
ty
specfl"cally addressed herein. �
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
saturated with asphalt.
ASTM D 226, with asphalt. Type I underlayment
saturated with constructed from a non -perforated organic felt that,
Vti I M D 226, Type II underlayrentcohsWcted from turated with asphalt.
m a nonpeyorafed organic felt that is
ASTM D 226, Type II uerla saturated with asphi/t Ynent onstru
from a non�perfo,'aced organic felt that
Self -adhered, fiewrJAg�p at►s
with a polymer fil the suffice an and TqS 103, rubberized
anda removable release film
Self -adhered, fl , AS7 D asphalt sheet
Polymer 1970, °n the adhesivmemb�a"e
ymer film on drfa� and a remoyab eb elea fas o aft � sheet a side.
ntheadhesiveSbmne with a
I/ Ida.
FL12328-R8
uct approval under
Rule 61f;20as throu-
anstalla °Rhrecornmended � t heThe manufacturer Page 1 of4
duration for shall notify CR se, or other produrth�ch this report is E dK
are not
r
C �j l TAMKO BUILDING PRODCUTS, INC.
j� TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKOO TAM -FELT Alternate to ASTM D 226; Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below. I
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to und'erlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
,
The minimum application temperature shall be 50OF except as follows:
a) The minimum application temperature of TAMKO® TW Metal and Tile Underlayment and TAMKO® TW
Underlayment shall be 40°F. /
b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKO® ASTM Slate Surfaced Roll Roofing shall be 2:12.
Undedayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO® TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
i
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
,
Allowable Roof Coverin s:
Metal Roof.
Mineral
Wood
Asphalt
Panels and
Surfaced Roll
Shingles and
Slate
dlay and
Underlayment
I .Shin les
Shingles',Roofing
Shakes
Shingles
Concrete Tile
TAMKOO ASTM Slate
t Y1
N
N
N
N
Y
Surfaced Roll Roofing
TAMKO® ASTM Tile
N
N
N
N
N
Y
Underlayment
TAM KO® Master Smooth
Y�
N
N
N
N
N
TAMKO® Moisture Guard® i/
Y
N
N
N
N
N
TAMKO® No. 15 ASTM
Asphalt Saturated Organic,
Y
Y
Y
YZ
N
N
Felt
TAMKO® No. 15 UL Asphalt
Y
Y
Y
YZ
Y
N
Saturated Organic Felt
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
elt
TAMKO® No. 30 UL Asphalt
Y
Y
Y
N
Y
N
Saturated Organic Felt
TAMKO® TW Metal and Tile
Y
Y
N
N
N
Y
Underlayment
TAMKO® TW Underlayment
Y
Y
N
N
N
N
TAMKOO TAM -FELT
Y
N
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation, report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK ,� TAMKO BUILDING PRODCUTS, INC:
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum- roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as,described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20 3.
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies (rST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies; (TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies (TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies (TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies (fST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC (TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-R8 page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer .ram g0((fy CjEEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this repanve valid
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK / TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
0 TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
ER. pNi 415-,
IV
2017.10.19
No 741021
12:15:58
_04'00'
:'13 �. STATE OF :• J
O •. <v .
T •.�� O P,: N_�.`
Zachary R. Priest, P.E.
Registration No. 021
ni ation No A E9641Florida
Organization
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.