HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTBCIS Home I Log In I User Registration I Hot Topics I Submit
Florida
�a Product Approval
.� W USER: Public User
-. W.
Product ARproyal Menu > Product or Application Search >
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category I
Subcategory
Compliance Method
IME-7 7��
SCANNED
93Y
irge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I
> Application Detail
Revision
2017
Approved
TAMKO Building Products, Inc.
PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri—eden@tamko.com
Kerri Eden
kerrL_eden@tamko.com
Kern Eden
PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext2305
kerri—eden@tamko.com
Roofing
Underlayments
F
EIVED
18 2018
.uceCountY. Permitting
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
D Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date O1/07/2019
Validated By Locke Bowden P.E.
Certificate of Independence i
i
Referenced Standard and Year (of Standard)
i
O Validation Checklist - Hardcopy Received
FL12328 R8 COI TBP14001.4 2017 FBC Eval Report TAMKO
Berl yments final.Ddf
Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4869
2016
ASTM D6380
2003
TAS 103
1995
Equivalence of Product Standards,
Certified By
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments finel.pd
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva[ Report TAMKO
Underlayments final.pdf
I
Created by Independent Third Party: Yes
7
No. 30 ASTM
Asphalt saturated organic felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes I
Approved for use outside HVHZ: Yes I
Impact Resistant: N/A
12 R8 II TBP14001.4 2017 FBC Eval Report TAMKQ
Uhderlayments final.pdf
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
I
reated by Independent Third Party: Yes
er: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underiayments final.pdf
I
Created by Independent Third Party: Yes
12328.8
No. 30 UL I
Asphalt saturated organic felt
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eva[ Report TAMKO
Underlayments final.pd
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
I
Created by Independent Third Party: Yes
12328.9
TAM -FELT I
Alternate to ASTM D 226, Type II underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes j
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12378 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
i
Under ayments final.pdf
Created by Independent Third Party: Yes
12328.10
TW Metal and Tile Underlayment
self -adhering modified bitumen underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A I
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.11
TW Underiaymenf
self -adhering modified bitumen underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ: Yes
Underlayments final.pd�
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underiayments final.pdf
Created by Independent Third Party: Yes
Back Mext
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Accessibilily Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official'communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
CREEK
TECHNICAL SERVICES LLC
I
EVALUATION REPORT i
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, r EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
hftp://www.tamko.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO® ASTM Slate
ASTM D 6380, Class M, Type' II underlayment constructed from organic felt saturated
Surfaced Roll Roofing
I
with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKOV ASTM Tile
Underlayment
ASTM D 6380, Class M, Typ I II underlayment constructed from an organic felt saturated
with asphalt then coated on Troth sides with asphalt and surfaced with granules.
TAMKO@) Master
Smooth
ASTM D 6380, Class S, Typ I N underlayment constructed from an organic felt saturated
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only. i
TAMKO® Moisture
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard®
with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO® No.15 ASTM
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
I
TAMKOO No. IS UL
ASTM D 226, Type I undedayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Orga '
TA 00 No. 30 AST
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKOO No. 30 UL ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO®TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4
This evaluation report is provided for State of Florid
Technical Services, LLC of any product changes or
This evaluation report does not express nor imply v
specifically addressed herein.
FL12328-R8
1 of 4
ict approval under Rule 61G20-3. The manufacturer shall notify CREEK
assurance changes throughout the duration for which this report is valid.
r, installation, recommended use, or other product attributes that are not
IN
CREEK
TECHNICAL SERVICES, LLC
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TAMKD@ TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irn
checked for protrusion and corrected prior to underlayment
The roof deck shall be constructed of closely fitted plywood
shall be installed in accordance with FBC requirements. I
joints.
The minimum application temperature shall be 50°F except
a) The minimum application temperature of TAM
Underlayment shall be 40°F.
b) The minimum application temperature of TAM
The minimum roof slope shall be in accordance with FBC rE
a) The minimum slope of TAMKD@ ASTM Slate
and debris. All fasteners in the deck shall be
thing for new or existing construction. Plywood deck
decks shall have no more than 1/8" gap at abutting
follows:
0 TW Metal and Tile Underlayment and TAMKD@ TW
Moisture Guard® shall be 35°F.
is except as follows:
Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKD@ TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
i
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
I
Allowable Roof Coverinas:
Metal Roof
Mineral
Wood
Asphalt
Panels and jj
Surfaced Roll
Shingles and
Slate
Clay and
Underlayment
Shingles
Shingles 1.
Roofin
Shakes
Shingles
Concrete Tile
TAMKO@ ASTM Slate
Y'
N
N
N
N
Y
Surfaced Roll Roofing
TAMKO@) ASTM Tile
N
N
N
N
N
Y
Underlayment
!
TAMKO@ Master Smooth
YI
N
N
N
N
N
TAMKO@ Moisture Guard@
Y
N
N
N
N
N
TAMKO@ No. 15 ASTM
Asphalt Saturated Organic
Y
Y I
Y
YZ
N
N
Felt
TAMKO@ halt
Y
Y I
Y
YZ
Y
N
S rganic 1
,ITAMKM No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
—TAffKO@ No. 30 UL Asphalt
Y
Y
Y
N
Y
N
Saturated Organic Felt
TAMKO@ TW Metal and Tile
Y
Y
N
N
N
Y
Underlayment
TAMKO@ TW Underlayment
Y
Y
N
N
N
N
TAMKO@) TAM -FELT
Y
N
N
N
N
N
Notes: 1) Open valley applications per 1507.2.9:2
2) Wood shingles only
TBP14001.4
FL12328-R8
2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Umtwiolsis
1) Fire Classification is not within the scope of this evalu
2) Wind uplift resistance in not within scope of this evalu
3) Installation of the evaluated product shall comply with
application instructions. Where discrepancies exist
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperat�
5) Unless otherwise stated, the minimum roof slope shal
6) All underlayments shall be installed with the roll len
in successive courses installed up the deck in a ma
laps shall be staggered between courses in accordan
7) The underlayment may be used as described in othe
8) The underlayment shall not be installed over existing
9) Contact the manufacturer regarding specific exposur
10) All products listed in this report shall be manufacture
Rule 61G20-3.
REFERENCES
Enti
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (rST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (rST6049)
UL LLC (rST9628)
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
report, the FBC, and the manufacturer's published
een these sources, the more restrictive and FBC
r
d
ures below the minimum application temperature.
I be in accordance with FBC requirements.
gth parallel to the eave, starting at the eave, and lapped
nner that effectively sheds water from the deck. End
ce with the manufacturer's application instructions.
current FBC product approval documents.
roof coverings.
e limits for each underlayment.
under a quality assurance program in compliance with
ReportI No.
Standard
Year
TAP-192-02-01
ASTM D 1970
2015a
TAP-193-02-01
ASTM D 1970
2015a
TAP-214-02-01
ASTM D 4869
2016
TAP-215-02-01
ASTM D 226
2009
TAP-216-02-03
ASTM D 6380
2003(2013)
TAP-217-02-01REV
ASTM D 6380
2003(2013)
TAP-2,18-02-01
ASTM D 226
2009
TAP-219-02-01
ASTM D 226
2009
TAP-220-02-01
ASTM D 6380
2003(2013)
TAP-222-02-01
ASTM D 4869
2016
TAP-245-02-01
TAS 103
1995
j
ASTM D 4798
2011
TAP-311-02-01
ASTM D 1970
2015a
TAP-319-02-01.1
ACC 188
2012
TAP-387-02-01
ASTM D 1970
2015a
TAP-388-02-01
ASTM D 1970
2015a
13CA12269
ASTM D 226
2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty; installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
0RY 'R 111"���,i
��•`G�P, .
No 74021
STATE OF
.I
I
i
CERTIFICATION OF INDEPENDENCE j
2017.10.19
12:15:58
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation_
Zachary R. Priest, P-E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
I
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
i
TBP14001.4
i
I
END OF REPORT
I
FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida produc
Technical Services, LLC of any product changes or quality a
This evaluation report does not express nor imply warranty,
specifically addressed herein.
I under Rule 61G20-3. The manufacturer shall notify CREEK
changes throughout the duration for which this report is valid.
n, recommended use, or other product attributes that are not