HomeMy WebLinkAboutLETTER-RESPONSE TO COMMENTSE C T S June 11, 2018 Design roupinc. St. Lucie County I i Planning & Development Services I Building & Code Regulation Division County 2300 Virginia Avenue Fort Pierce, FL. 34982 Attn: Building Plan Examiner RE: Standard Pacific Homes Riverbend Lot 44 Permit No. # BLDG 180 -0451 1I Dear Sir/Madam, This letter serves as my response toi comments: Single Family Residence SCANNED 0-Y Wurip rntafi JUL 25 2018 Permitting Department St. Lucie County, FL 1. Please furnish fasteners tojbalcony handrail details for in accordance with 107.2.1 of the 2017 Florida Building Code Sixth Edition. Response: See updated Product Approval for balcony handrail fasteners attached. 2. Please show balcony handrail (bottom rail) in accordance with R312.1.3 of the 2017 Florida Building Code Sixth Edition. Response: Revised balcony handrail (bottom rail) in accordance with R312.1.3 of the Florida Building Code Sixth Edition. See delta 1 on sheet A5D. 1 3. Please provide gas riser detail as per chapter 1, section 107 of the 2014 Florida Building Code. Response: Gas riser not required for this home as this is not a gas provided community. I 4. Please show automatic garage door opener being in accordance with the 309.4 of the 2017 Florida residential Code Sixth Edition. Response: Added note showingautomatic garage door opener being in accordance with the 309.4 of�the 2017 Florida residential Code Sixth Edition. See delta 1 on sheet El. i Riverbend Lot 44 Permit No. BLDG 1805-0451 1441 N. Ronald Reagan Blvd. • Longwood, FL 32750 • Phone: (407) 774-6078 • Fax: (407) 774-4078 I AA0003325 www.abdesigngroup.com A R C H I T E C T S Design roue Inc. 5. Please add the live load for the floor and live load for the roof in accordance with Table 301.5 and table 301.5 of the 2017 Florida Residential Code Sixth Edition. Response: Please refer to the "Notes" located on sheet SDI under "Design Criteria" for roof and floor load info. 6. Please add the live load for the floor and live load for the roof in accordance with Table 301.6 and table 301.6 of the 2017 Florida Residential Code Sixth Edition. Response: Please refer to the "Notes" located on sheet SDI under "Design Criteria" for roof and floor load info. 7. Building code reference is out dated code cycle. Designs must comply to FL Building Code 6'h Edition 2017. Please review plans and make corrections. Response: Updated stair detail comply to the Florida Building Code 6" Edition 2017. See delta I on sheet D1. Zonin 1. Please indicate the finished floor elevation from Lot 43 and 45 on survey. Response: See updated survey attached. If you have any questions please contact me at (407) 774-6078. i Sincerely, I i James Cantwell Florida Architect #12079 I 2 Riverbend Lot 44 Permit No. BLDG 1805-0451 1441 N. Ronald Reagan Blvd. • Longwood, FL 32750 • Phone: (407) 774-6078 • Fax: (407) 774-4078 1 AA0003325 com