HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & FINAL APPROVALI
I
SCANNED
STATE OF FLORID LMI(�V ,ilY
b DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
•ry�oWV.
APPLICANT: stands
AGENT: The MIIcor G
PROPERTY ADDRESS:
LOT: 44
SUBDIVISION:
'acific Of Florida, GP
J, Inc.
3027 NW Radcliffe VI
Riverbend
I
City, JFL 34990
J
BLOCK:
ID#:1 4425-70370049-000-0
APPLICATION #:AP1312383
PERMIT #:56-SF-1797849
DOCUMENT #: F11307962
DATE PAID:02/15/2018
FEE PAID:55.00
RECEIPT #:.56-PID-3483280
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH. STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
( ]
[01]
TANK SIZE [1] 1090.00 [21 483.00
[ ]
[02]
TANK MATERIAL Polypropylene
[ ]
(031
OUTLET DEVICE
[ ]
[041
MULTI -CHAMBERED [ Y N ] I
[ ]
[05]
OUTLET FILTER Polylok PL-68
[ ]
[061
LEGEND 1, 70-143-11SC4 2. 70-143-548C,
[ ]
[071
WATERTIGHT
]
[081
LEVEL
[ ]
(09]
DEPTH TO LID
DRAINFIELD INSTALLATION
( ]
(101
AREA [1] 656.56 [21 SOFT
[ ]
[111
DISTRIBUTION BOX HEADER X
[ ]
[121
NUMBER OF DRAINLINES 1. 4.00 2.
[ ]
(13]
DRAINLINE SEPARATION
[ ]
[14]
DRAINLINE SLOPE
[ }
[151
DEPTH OF COVER
[ ]
[161
ELEVATION [ ABOVE / BELOW ]BM 14.00
[ ]
[171
SYSTEM LOCATION
[ ]
[181.
DOSING PUMPS 1.00
[ ]
[19]
AGGREGATE SIZE
[ ]
[20]
AGGREGATE EXCESSIVE FINES
[ ]
(21]
AGGREGATE DEPTH
FILL / EXCAVATION MATERIAL
L ]
[22]
FILL AMOUNT
[ ]
[231
FILL TEXTURE I
[ ]
(241
EXCAVATION DEPTH
[ ]
[25]'
AREA REPLACED
[ ]
[26]
REPLACEMENT MATERIAL I
Comments:
Comments are on page 2. 1
CONSTRUCTION [ APPROVED / DISAPPROVED )'
FINAL SYSTEM [ APpROVED / DISAPPROVED ],
I
(Explanation of. Violations on following page) I
I
DH 4016, 08/09 (Obsoletes all previous ec
Incorporated: 64E-6..003, FAC
EH Database v 1.0.1 I
SETBACKS
[ ]
[271
SURFACE WATER 100
FT
[ ]
[281
DITCHES
FT.
[ ]
[291
PRIVATE WELLS
FT
[ ]
1301
PUBLIC WELLS
FT
[ 1
[311
IRRIGATION WELLS
FT
[ ]
['321
POTABLE WATER 14
FT
[ ]
[331
BUILDING FOUNDATIONS 6
FT
[ ]
[341
PROPERTY LINES 10
FT
[ ]
[351
OTHER
FT
FILLED / MOUND SYSTEM
[ ]
[361
DRAINFIELD COVER
[ ]
. [37]
SHOULDERS
[ ]
[38]
SLOPES
[ ]
[39]
STABILIZATION 06/26/2019
ADDITIONAL INFORMATION
[ ]
[40]
UNOBSTRUCTED AREA
[ ]
[411
STORMWATER RUNOFF
[ l
[421
ALARMS
[ ]
[431
MAINTENANCE AGREEMENT
[ ]
[441
BUILDING AREA
[ ]
[4.5]
LOCATION CONFORMS WITH SITE PLAN
[ ]
[46]
FINAL SITE GRADING
[ ]
[47]
CONTRACTOR Brian Davis (Brian Davis Sept
[ ]
148 ]
OTHER INFILTRATOR Quick4 Plus EQ36
LP
ABANDONMENT
[ ]
[4'9]
TANK PUMPED
[ ]
[50]
TANK CRUSHED S FILLED
==21!2. St. Lucie CHD DATE; 04/25/2019
(ENVIRONMENTAL HEALTH)
---. St. Lucie CHD DATE: 06./26/2019
(ENVIRONMENTAL HEALTH)
tions which may not be used)
AP1312383 EID1797849
Page 2 of 3
:. STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
�c CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment.
Comments
The system is sized for 5 bedrooms with a maximum occupan
gpd•
New 1090+483gal STs installed in series. New outlet filter, 483
DF installed. No violations, system ok to cover. Contractor noti
site grading.
Final system aDDroved. Contractor and building department emi
APPLICATION #.AP131.2383
PERMIT #:56-SF-1797849
DocumENT #:FI"1307962
DATE PAID:02/15/2018
FEE PAID.:55.00
RECEIPT #:56-PID-3483280
of 10 persons (2 per bedroom), for a total estimated flow of 520
I DT(70-143-54S-C4), liberty 113 hp pump, and 2x!4+2x15 long.
i by phone. Needs final inspection for mound system and final
d final approval.
DH 4016, 08/09 (Dbsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v 1,0.1 I AN312383 EID1797849
Page 2 of 3