Loading...
HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & FINAL APPROVALI I SCANNED STATE OF FLORID LMI(�V ,ilY b DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL •ry�oWV. APPLICANT: stands AGENT: The MIIcor G PROPERTY ADDRESS: LOT: 44 SUBDIVISION: 'acific Of Florida, GP J, Inc. 3027 NW Radcliffe VI Riverbend I City, JFL 34990 J BLOCK: ID#:1 4425-70370049-000-0 APPLICATION #:AP1312383 PERMIT #:56-SF-1797849 DOCUMENT #: F11307962 DATE PAID:02/15/2018 FEE PAID:55.00 RECEIPT #:.56-PID-3483280 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH. STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION ( ] [01] TANK SIZE [1] 1090.00 [21 483.00 [ ] [02] TANK MATERIAL Polypropylene [ ] (031 OUTLET DEVICE [ ] [041 MULTI -CHAMBERED [ Y N ] I [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [061 LEGEND 1, 70-143-11SC4 2. 70-143-548C, [ ] [071 WATERTIGHT ] [081 LEVEL [ ] (09] DEPTH TO LID DRAINFIELD INSTALLATION ( ] (101 AREA [1] 656.56 [21 SOFT [ ] [111 DISTRIBUTION BOX HEADER X [ ] [121 NUMBER OF DRAINLINES 1. 4.00 2. [ ] (13] DRAINLINE SEPARATION [ ] [14] DRAINLINE SLOPE [ } [151 DEPTH OF COVER [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 14.00 [ ] [171 SYSTEM LOCATION [ ] [181. DOSING PUMPS 1.00 [ ] [19] AGGREGATE SIZE [ ] [20] AGGREGATE EXCESSIVE FINES [ ] (21] AGGREGATE DEPTH FILL / EXCAVATION MATERIAL L ] [22] FILL AMOUNT [ ] [231 FILL TEXTURE I [ ] (241 EXCAVATION DEPTH [ ] [25]' AREA REPLACED [ ] [26] REPLACEMENT MATERIAL I Comments: Comments are on page 2. 1 CONSTRUCTION [ APPROVED / DISAPPROVED )' FINAL SYSTEM [ APpROVED / DISAPPROVED ], I (Explanation of. Violations on following page) I I DH 4016, 08/09 (Obsoletes all previous ec Incorporated: 64E-6..003, FAC EH Database v 1.0.1 I SETBACKS [ ] [271 SURFACE WATER 100 FT [ ] [281 DITCHES FT. [ ] [291 PRIVATE WELLS FT [ ] 1301 PUBLIC WELLS FT [ 1 [311 IRRIGATION WELLS FT [ ] ['321 POTABLE WATER 14 FT [ ] [331 BUILDING FOUNDATIONS 6 FT [ ] [341 PROPERTY LINES 10 FT [ ] [351 OTHER FT FILLED / MOUND SYSTEM [ ] [361 DRAINFIELD COVER [ ] . [37] SHOULDERS [ ] [38] SLOPES [ ] [39] STABILIZATION 06/26/2019 ADDITIONAL INFORMATION [ ] [40] UNOBSTRUCTED AREA [ ] [411 STORMWATER RUNOFF [ l [421 ALARMS [ ] [431 MAINTENANCE AGREEMENT [ ] [441 BUILDING AREA [ ] [4.5] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING [ ] [47] CONTRACTOR Brian Davis (Brian Davis Sept [ ] 148 ] OTHER INFILTRATOR Quick4 Plus EQ36 LP ABANDONMENT [ ] [4'9] TANK PUMPED [ ] [50] TANK CRUSHED S FILLED ==21!2. St. Lucie CHD DATE; 04/25/2019 (ENVIRONMENTAL HEALTH) ---. St. Lucie CHD DATE: 06./26/2019 (ENVIRONMENTAL HEALTH) tions which may not be used) AP1312383 EID1797849 Page 2 of 3 :. STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM �c CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment. Comments The system is sized for 5 bedrooms with a maximum occupan gpd• New 1090+483gal STs installed in series. New outlet filter, 483 DF installed. No violations, system ok to cover. Contractor noti site grading. Final system aDDroved. Contractor and building department emi APPLICATION #.AP131.2383 PERMIT #:56-SF-1797849 DocumENT #:FI"1307962 DATE PAID:02/15/2018 FEE PAID.:55.00 RECEIPT #:56-PID-3483280 of 10 persons (2 per bedroom), for a total estimated flow of 520 I DT(70-143-54S-C4), liberty 113 hp pump, and 2x!4+2x15 long. i by phone. Needs final inspection for mound system and final d final approval. DH 4016, 08/09 (Dbsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1,0.1 I AN312383 EID1797849 Page 2 of 3